Plan Review Details - Permit 21101110
Plan Review Stops For Permit 21101110
Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-05 Cont ID  
Sent By ccarvaja Date 2021-11-05 Time 16:32 Rev Time 0.00
Received By ccarvaja Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-04 Cont ID  
Sent By lcrespo Date 2021-11-04 Time 10:00 Rev Time 0.00
Received By lcrespo Date 2021-11-03 Time 09:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By lcrespo Date 2021-11-05 Time 14:44 Rev Time 0.00
Received By lcrespo Date 2021-11-05 Time 14:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-11-04 Cont ID  
Sent By lcrespo Date 2021-11-04 Time 09:54 Rev Time  
Received By lcrespo Date 2021-11-04 Time 07:59 Sent To  
Notes
2021-11-04 09:57:2711/04/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. WOULD YOU PLEASE PROVIDE MANUFACTURER?S
 SPECIFICATIONS FOR THE BACKFLOW PREVENTER. THE MAKE,
 MODEL, AND SIZE OF THE DEVICE SHALL BE LISTED IN THE
 DESCRIPTION OF THE WORK SECTION ON THE PERMIT
 APPLICATION.
  
 2. DOCUMENTATION THAT THE PROPOSED DEVICE IS LEAD-FREE
 WHICH CONTAINS NOT MORE THAN 0.25-PERCENT LEAD.
  
 3. PIPE, PIPE FITTINGS, JOINTS, VALVES, FAUCETS AND
 FIXTURE FITTINGS UTILIZED TO SUPPLY WATER FOR DRINKING
 OR COOKING PURPOSES SHALL COMPLY WITH NSF 372 AND SHALL
 HAVE A WEIGHTED AVERAGE LEAD CONTENT OF 0.25 PERCENT OR
 LESS PER THE 2017 FBC SEC. P 605.2.1 LEAD CONTENT OF
 DRINKING WATER PIPE AND FITTINGS.
  
 4. DOCUMENTATION THAT THE PROPOSED BACKFLOW DEVICE IS
 ON THE APPROVED DEVICE LIST PUBLISHED BY THE UNIVERSITY
 OF SOUTHERN CALIFORNIA (USC). PLEASE CONTACT THE
 DEPARTMENT OF PUBLIC UTILITY FIELD CUSTOMER SERVICE AT
 561-822-2240 FOR DOCUMENTED CONFIRMATION THAT THE
 PROPOSED BACKFLOW PREVENTION DEVICE COMPLIES WITH CITY
 REQUIREMENTS
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop PU PUBLIC UTILITIES
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By ccarvaja Date 2021-11-05 Time 16:32 Rev Time 0.00
Received By ccarvaja Date   Time   Sent To  
Notes
***NONE***

Review Stop PU PUBLIC UTILITIES
Rev No 1 Status F Date 2021-11-04 Cont ID  
Sent By lcrespo Date 2021-11-04 Time 10:00 Rev Time 0.00
Received By lcrespo Date 2021-11-04 Time 10:00 Sent To  
Notes
***NONE***