Plan Review Details - Permit 21101068
Plan Review Stops For Permit 21101068
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-28 Cont ID  
Sent By cthroop Date 2021-10-28 Time 12:58 Rev Time 0.00
Received By cthroop Date 2021-10-27 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-22 Cont ID  
Sent By cthroop Date 2021-10-22 Time 15:06 Rev Time 0.00
Received By cthroop Date 2021-10-22 Time 15:03 Sent To  
Notes
2021-10-22 15:08:57BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE STATEMENT OF EVENT FUNCTION.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. DOES THE TENT HAVE SIDES. LIFE SAFETY PLAN MAY BE
 REQUIRED.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. **ADDITIONAL REQUIREMENTS
 FOR TEMPORARY MEMBRANE STRUCTURES (TENTS) WITH A SPAN
 OF 40 FEET OR GREATER IN ANY DIRECTION:
  
 A. PROVIDE DETAILS OF STRUCTURAL CONNECTIONS. INCLUDE
 BASEPLATE/TIEDOWN DETAILS.
 B. PROVIDE STRUCTURAL EVALUATION OF STRUCTURE.
  
 THESE DOCUMENTS SHALL BE REVIEWED, SIGNED AND SEALED BY
 A DESIGN PROFESSIONAL.
  
 NO EXCEPTIONS BY ORDER OF THE BUILDING OFFICIAL
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-27 Cont ID  
Sent By pleduc Date 2021-10-27 Time   Rev Time 0.00
Received By pleduc Date 2021-10-27 Time 14:26 Sent To  
Notes
2021-10-27 14:28:00FIRE COMMENT:
  
 APPLICANT PROVIDED DOCUMENT STATING OPEN ALL SIDES.
  
 PROVIDE 2 - 10LB ABC MOUNTED FIRE EXTINGUISHERS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-10-22 Cont ID  
Sent By pleduc Date 2021-10-22 Time   Rev Time 0.00
Received By pleduc Date 2021-10-22 Time 16:18 Sent To  
Notes
2021-10-22 16:25:43THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS NO INDICATIONS OF OPEN/SIDE WALLS AND
 PROPOSED EXITS IF APPLICABLE.
  
 FOR THE OFFICIAL RECORD, PLEASE INDICATE IF THE WALLS
 WILL BE OPEN OR PROPOSED EXITS IF APPLICABLE.
  
  
  
 2) PLEASE PROVIDE FOR A MINIMUM OF 2 MOUNTED 10LB ABC
 FIRE EXTINQUISHERS
  
  
  
 3) PLEASE PROVIDE THE PROPOSED TIE-DOWN/STAKE/BARREL
 ENGINEERING SYSTEM.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-28 Cont ID  
Sent By cthroop Date 2021-10-28 Time 13:00 Rev Time 0.00
Received By cthroop Date 2021-10-26 Time 10:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-23 Cont ID  
Sent By lmarchan Date 2021-10-23 Time 09:03 Rev Time 0.00
Received By lmarchan Date 2021-10-22 Time 13:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-11-05 Cont ID  
Sent By dbattles Date 2021-11-05 Time 09:02 Rev Time 0.00
Received By dbattles Date 2021-11-05 Time 08:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-10-28 Cont ID  
Sent By cthroop Date 2021-10-28 Time 12:58 Rev Time 0.00
Received By cthroop Date 2021-10-28 Time 12:56 Sent To  
Notes
2021-10-28 12:59:58SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 1ST REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: TENT CONNECTION DETAIL AND DESIGN WIND LOAD
 CALCULATIONS.
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  
  