| Plan Review Stops For Permit 21100899 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-10-28 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-28 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2021-10-28 15:15:31 | WORK IS BEING DONE ON THE FRONT MAIN PROPERTY. THE REAR | | | HALF ADDRESS READDRESSED AS 735 NEW YORK ST |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-10-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-10-20 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-20 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2021-10-20 16:02:16 | WHICH BUILDING IS THE WORK TO BE DONE, NORTH OR SOUTH? | | | THE NORTH BUILDING HAS A HALF ADDRESS WHICH WILL NEED | | | TO BE READDRESSED. PLEASE HAVE THE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 TO READDRESS THE | | | HALF ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-11-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-13 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-13 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-11-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-02 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-02 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2021-11-02 17:15:12 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. REF. THE WALL LEGEND ON PLAN PAGES A-1 AND A-2 FOR | | | THE FOLLOWING COMMENT: | | | THE WALL LEGEND SHOWS THE EXTERIOR LOAD BEARING WALLS | | | TO BE REMOVED. | | | PLEASE CLARIFY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. WINDOW TYPE ON PAGE A-2 STATES SINGLE HUNG WINDOWS. | | | NOA 20-0519.09 IS FOR FIXED WINDOWS. | | | PROVIDE PRODUCT APPROVALS FOR SINGLE HUNG WINDOWS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 3. NOTE ON PAGE A-2 STATES PROVIDE NEW HURRICANE | | | SHUTTER. | | | SUBMIT A SCHEDULE FOR OPENING PROTECTIVE DEVICES OR | | | ASSEMBLIES. | | | SUBMIT PRODUCT APPROVALS FOR SHUTTERS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | | NEW FIREPLACE. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 5. PROVIDE AN EXTERIOR WALL ELEVATION AND DETAIL. SHOW | | | INTERIOR FINISH, WALL INSULATIUON AND EXTERIOR | | | CLADDING. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 6. REF. PLAN PAGE A-2 FOR THE FOLLOWING COMMENT: | | | GROUND FLOOR PLAN HAS A CUT DETAIL 3&4/S-1. THERE IS NO | | | S-1 PLAN TO REVIEW. | | | PLEASE CLARIFY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-10-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-27 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-27 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2021-10-27 13:09:04 | NO ELECTRICAL WORK TO BE DONE. JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-25 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-25 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2021-10-25 08:35:14 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NO ELECTRICAL WORK SHOWN, PLEASE INDICATE ANY | | | ELECTRICAL WORK TO BE DONE. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-10-26 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2021-10-26 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2021-10-26 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-11-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-13 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-09 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-03 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-20 |
Time |
11:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-10 |
Time |
06:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-10 |
Time |
06:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-25 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-25 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2021-10-25 07:49:44 | SHEET A-2 REFERENCES MECHANICAL SHOP DRAWINGS, THESE | | | WERE NOT SUBMITTED WITH THIS SUBMITTAL. PLEASE UPLOAD | | | THE MECHANICAL DRAWINGS INDICATING THE ALL NEW | | | MECHANICAL WORK FOR THIS PROJECT. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-22 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-22 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2021-10-22 14:46:14 | 10/22/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-11-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-13 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-13 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-10-20 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-20 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-20 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2021-10-20 12:35:24 | REVIEW OF SIGNATURE AND SEAL ON PAPER PLANS APPROVED | | | AND PLANS ROUTED TO STORAGE |
|
|