| Plan Review Stops For Permit 21100724 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
5 |
Status |
P |
Date |
2021-12-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-01 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-01 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2021-12-01 14:08:55 | WEST HALF ADDRESS UNIT READDRESSED TO 5002 PARKR AVE. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
F |
Date |
2021-12-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-01 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-01 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2021-12-01 11:14:34 | THE WEST UNIT HAS A HALF ADDRESS WHICH WILL NEED TO BE | | | READDRESSED. PLEASE HAVE THE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 TO READDRESS THE | | | HALF ADDRESS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-19 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-19 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2021-11-19 12:02:45 | PRIMARY ADDRESS FOR THE PROJECT IS APPROPRIATE HOWEVER | | | SECOND UNIT HAS A HALF ADDRESS WHICH WILL NEED TO BE | | | READDRESSED. PLEASE HAVE THE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 TO READDRESS THE | | | HALF ADDRESS |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-15 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-15 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2021-11-15 16:43:33 | PRIMARY ADDRESS OF FOR THE PROJECT HOWEVER SECOND UNIT | | | HAS A HALF ADDRESS WHICH WILL NEED TO BE READDRESSED. | | | PLEASE HAVE THE OWNER CONTACT [email protected] OR CALL | | | 561-805-6659 TO READDRESS THE HALF ADDRESS |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-10-21 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-21 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-10-21 11:22:35 | PRIMARY ADDRESS OF FOR THE PROJECT HOWEVER SECOND UNIT | | | HAS A HALF ADDRESS WHICH WILL NEED TO BE READDRESSED. | | | PLEASE HAVE THE OWNER CONTACT [email protected] OR CALL | | | 561-805-6659 TO READDRESS THE HALF ADDRESS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2021-12-01 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-12-01 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-12-01 |
Time |
07:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-11-29 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-11-29 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2021-11-29 12:15:51 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL11560.5-R4 COVERS MULTIPLE FASTENER SPACING | | | TO MEET DESIGN UPLIFT PRESSURES. PLEASE SELECT CORRECT | | | FASTENER PATTERN & SPACING FROM DESIGN UPLIFT PRESSURE | | | PAGE #2 OF THE EVALUATION REPORT THAT MEET OR EXCEED | | | THE MINIMUM DESIGN PRESSURE REQUIREMENT FOR ZONE 3 | | | EXPOSURE CATEGORY C AREAS. (-108.17). ALL APPLICABLE | | | DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON | | | THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS | | | NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | | SITE-SPECIFIC ENGINEERING | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-11-19 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-11-19 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2021-11-19 12:59:46 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL11560.4-R4 DOES NOT MEET THE MINIMUM ZONE 3 | | | DESIGN PRESSURE REQUIREMENT OF -108.17 FOR EXPOSURE | | | CATEGORY C AREAS. PROVIDE SYSTEM THAT MEETS OR EXCEEDS | | | ALL DESIGN PRESSURE REQUIREMENTS FOR EXPOSURE CATEGORY | | | C/PROVIDE SIGNED AND SEALED ENGINEERED NAILING | | | CALCULATIONS WITH AN APPROVED SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-11-16 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-11-16 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2021-11-16 14:42:35 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW | | | ROOFING CLEARLY IDENTIFIED ON DRAWING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-24 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-24 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2021-10-24 11:01:11 | ROOFING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A ROOF PLAN OR SKETCH. PROVIDE MRH AND ROOF | | | PITCH. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE COVER SHEETS FOR PRODUCT APPROVAL FL | | | 11560-R4. | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2021-12-01 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2021-12-01 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-12-01 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-12-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-01 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-30 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2021-11-29 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-11-24 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-11-19 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-11-18 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-11-16 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-11-15 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-24 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-21 |
Time |
08:03 |
Sent To |
|
|
| Notes |
|
|