| Plan Review Stops For Permit 21100714 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-09 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-09 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2021-11-09 16:24:49 | ADDRESS CORRECT FOR PROJECT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-30 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-30 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-06-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-18 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-18 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2022-06-18 10:08:51 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. MANDATORY: PROVIDE A COPY OF YOUR MOST RECENT | | | BOUNDARY LINE SURVEY. | | | | | | REF: SEE COMMENT FROM 2ND REVIEW | | | 1. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-04 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-03 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2022-04-04 13:20:49 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1ST REVIEW COMMENTS: SEE BELOW. | | | | | | 1. CORRECTED | | | | | | 2. CORRECTED | | | | | | 3. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 (NOT | | | PROVIDED) | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | (SEE NEW COMMENTS BELOW) | | | | | | 5. CORRECTED | | | | | | | | | 6. PROVIDE ENERGY CALC'S. (NOT PROVIDED) | | | | | | 7. CORRECTED | | | | | | NEW COMMENTS: | | | | | | 8. SEE ITEM #4 ABOVE: | | | FL13459, NOA 20-0722, NOA 200519 AND NOA 20-0729 ARE | | | MISSING THE INSTALLATION INSTRUCTIONS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 9. PROVIDE PRODUCT APPROVALS FOR CASEMENT WINDOWS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 10. PROVIDE AN EXISTING FLOOR PLAN. IDENTIFY AREAS OF | | | DEMOLITION. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 11. PROVIDE DESIGN PRESSURES FOR NEW ROOFING PER FBC R | | | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 12. PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER DESIGN | | | PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-18 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-17 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2021-12-18 08:36:22 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: A COMPREHENSIVE REVIEW COULD NOT BE PERFORMED | | | AT THIS TIME: ONLY STRUCTURAL PLANS SUBMITTED FOR | | | REVIEW. | | | | | | 1. PROVIDE ARCHITECTURAL PLANS. INCLUDE THE FOLLOWING | | | INFORMATION: | | | PROVIDE PROJECT DATA/DESIGN PARAMETERS: | | | PROJECT DATA: 1&2 FAMILY DWELLING UNIT | | | OCCUPANCY CLASSIFICATION R3 SFR | | | SCOPE OF WORK | | | DESIGN PARAMETERS: 2020 FBC EXISTING BUILDING | | | 2020 FBC RESIDENTIAL | | | 2017 NEC | | | CLASSIFICATION OF WORK: ADDITION | | | BUILDING CLASSIFICATION: VB | | | EXPOSURE CLASSIFICATION: (B/C/D)? | | | RISK CATEGORY: II | | | MEAN ROOF HEIGHT: | | | EXISTING UNDER AIR: /SF | | | EXISTING COVERED: /SF | | | NEW UNDER AIR: /SF | | | NEW COVERED: /SF | | | TOTALS: UNDER AIR /SF | | | COVERED /SF | | | | | | | | | 2. PROVIDE A SITE PLAN W/BOUNDRY LINE SURVEY. IDENTIFY | | | LOCATION OF WORK. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE | | | SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN | | | ACCURATE AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | | | | 3. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 5. PROVIDE A WINDOW AND DOOR SCHEDULE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 6. PROVIDE ENERGY CALC'S. | | | R401.2COMPLIANCE. | | | PROJECTS SHALL COMPLY WITH ONE OF THE FOLLOWING: | | | 1.SECTIONS R401 THROUGH R404. | | | 2.SECTION R405 AND THE PROVISIONS OF SECTIONS R401 | | | THROUGH R404 LABELED ?MANDATORY.? | | | 3. AN ENERGY RATING INDEX (ERI) APPROACH IN SECTION | | | R406. *MUST BE PREPARED BY A 3RD PARTY* | | | R401.3ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | | | | 7. IDENTIFY CEILING AND WALL R-VALUE ON PLANS. | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | FBC EC-R101.5.1.1.2 BUILDING THERMAL ENVELOPE | | | ALTERNATIVE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-04-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-01 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-01 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-12-09 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-09 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-09 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2021-12-09 14:38:00 | NO ELECTRICAL PLANS ARE INCLUDED IN THE SUBMITTAL. | | | FLORIDA BUILDING CODE 107.2 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-02 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-02 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2022-06-02 11:54:56 | THE GAS PIPING AND APPLIANCES WILL BE INSTALLED UNDER A | | | SEPARATE PERMIT. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-05 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-05 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2022-04-05 14:35:03 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 21100714 | | | 4/5/22 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A1: CLARIFY IF THE GAS WATER HEATER IS NEW, | | | EXISTING, OR A REPLACEMENT IN THE SAME LOCATION. PLEASE | | | PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN INDICATING | | | THE MAKE AND MODEL, BTUH LOAD, AND EFFICIENCY RATING- | | | TABLE C404.2 FBC EC. COMMENT LISTED BELOW WILL APPLY TO | | | NEW INSTALLATIONS: | | | A) PROVIDE A DETAIL SHOWING THE INSTALLATION LOCATION | | | AND REQUIRED CLEARANCES AS RECOMMENDED BY THE | | | MANUFACTURER- SECTIONS G2406.1 & G2448.1 FBC RES. | | | B) PROVIDE A GAS RISER DRAWING- SEC. 107.3.5.3 WPB. | | | C) PROVIDE COMBUSTION AIR CALCULATIONS AND INDICATE HOW | | | THE AIR WILL BE PROVIDED- SEC. G2407.1 FBC RES. | | | D) PROVIDE A VENTING PLAN- SEC. G2426.2, G2426.7 FBC | | | RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-04-29 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-04-29 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-04-29 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2021-11-16 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2021-11-16 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-11-16 11:22:33 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | CASE IS GOING BEFORE HISTORIC PRESERVATION BOARD IN | | | DECEMBER, NO PERMIT CAN BE ISSUED BEFORE CASE IS HEARD | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | 561.822.1428 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-08-24 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-08-23 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-22 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-12 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-30 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-06-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-18 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-01 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-05-02 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-03-28 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-12-22 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-08 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-11-21 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-11-15 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2022-11-21 15:04:34 | RECEIPT MU-2022-052151 - $546.52 PAID | | 2022-11-15 09:28:38 | 11/15/2022 EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-12-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-18 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-18 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2021-12-18 08:02:20 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-02 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-02 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-05 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-05 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-09 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-09 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2021-11-09 15:45:03 | PLEASE SUBMIT THE ENERGY CALCULATIONS, MECHANICAL | | | EQUIPMENT SIZING AND A CODE COMPLIANT MECHANICAL | | | DRAWING WITH THE SCOPE OF WORK FOR THE MECHANICAL ON | | | THIS PROJECT. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-02 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-02 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-03-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-30 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-30 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-18 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-18 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2021-11-18 16:56:30 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21100714 | | | 11/18/21 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE PLUMBING PLANS INCLUDING A SANITARY | | | DRAINAGE ISOMETRIC DRAWING- SECTION 107.3.5.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-04 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-03 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-12-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-18 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-17 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2021-12-18 08:21:47 | ROOFING PROVISO ON PLAN PAGE S1.3. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-22 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-22 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-06-01 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-06-01 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-28 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-28 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2022-03-28 15:49:23 | REVIEW OF SIGNATURE AND SEAL ON PAPER PLANS AND | | | DOCUMENTS APPROVED AND PLANS ROUTED TO STORAGE. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-11-10 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-11-10 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2022-08-24 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2022-08-24 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2022-08-24 10:20:59 | ALL LANDSCAPING SHALL BE INSTALLED AND PASS INSPECTION | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY / | | | COMPLETION. SEE PERMIT #22081135. | | | | | | SEPARATE PERMITS REQUIRED FOR THE POOL/EQUIPMENT. | | | | | | IF ANY MODIFICATIONS ARE MADE TO THE EXISTING DRIVEWAY, | | | A SEPARATE PERMIT SHALL BE REQUIRED. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2022-08-19 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2022-08-19 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2022-07-20 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2022-07-20 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2022-07-20 10:26:55 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 06.17.2022 | | | PERMIT NO.: 21100714 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - CURRENT AND ACCURATE SURVEY SHALL BE | | | PROVIDED. | | | | | | 2. [ SATISFIED ] - A SITE PLAN SHALL BE PROVIDED. SITE | | | PLAN SHALL INCLUDE: | | | 2.1. DATE, NORTH ARROW, AND A GRAPHIC SCALE. | | | 2.2. VICINITY MAP SHOWING THE PROPERTY IN RELATION TO | | | THE SURROUNDING AREA. | | | 2.3. LOCATION OF THE PROPERTY LINE, RIGHT-OF-WAY, | | | PROPOSED/EXISTING EASEMENTS, WATER COURSES AND OTHER | | | ESSENTIAL FEATURES. | | | 2.4. STREETS, DRIVEWAYS, INTERSECTIONS, CURBS CUTS AND | | | TURNING LANES ADJACENT TO OR ACROSS FROM THE SUBJECT | | | PROPERTY. | | | 2.5. THE OUTLINES OF ALL BUILDINGS WITH USES, | | | SETBACKS, DIMENSIONS, FLOOR AREA, NUMBER OF STORIES, | | | HEIGHT AND POINTS OF ACCESS. | | | 2.6. LOCATION AND DIMENSIONS OF ALL PERIMETER | | | TREATMENT (SIDEWALKS, FENCES, WALLS, OR BERMS). | | | 2.7. MEANS OF VEHICULAR AND PEDESTRIAN ACCESS TO AND | | | FROM THE SITE. | | | 2.8. LAYOUT AND LOCATION OF ALL OFF-STREET PARKING, | | | LOADING AND OTHER VEHICULAR USE AREAS, INCLUDING WHERE | | | APPLICABLE, THE DISTANCE FROM THE PRINCIPLE USES. | | | | | | 3. [ NOT SATISFIED ] - PURSUANT TO SECTION 94-441 OF | | | THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS | | | (ZLDRS), BECAUSE THE PROPOSED SCOPE OF WORK EXCEEDS 50 | | | PERCENT OF THE VALUE OF THE EXISTING STRUCTURE, THE | | | SITE SHALL BE BROUGHT INTO COMPLIANCE WITH ARTICLE XIV | | | (LANDSCAPING) OF THE ZLDRS. PLANS SHALL BE SUBMITTED | | | INDICATING SUCH. IF EXISTING MATERIAL IS SHOWN ON THE | | | PLANS AND ALL PROVISIONS OF ARTICLE XIV HAVE BEEN MET, | | | THEN NO ADDITIONAL PERMIT/INSTALLATION IS REQUIRED. IF | | | THE EXISTING MATERIAL ON SITE DOES NOT CONFORM TO ALL | | | OF THE REQUIREMENTS OF ARTICLE XIV, THEN ADDITIONAL | | | MATERIAL WILL NEED TO BE SHOWN ON THE PLANS AND | | | PERMITTED UNDER A LANDSCAPE PERMIT. PLEASE NOTE THAT | | | PLANS SHOULD INCLUDE, BUT NOT BE LIMITED TO, THE | | | FOLLOWING: | | | 3.1. THE LOCATION OF ALL EXISTING AND PROPOSED | | | STRUCTURES, IMPROVEMENTS, ETC. | | | 3.2. THE LOCATION OF ALL EXISTING AND PROPOSED TREES, | | | SHRUBS, GROUND COVERS, ETC. | | | 3.3. THE LOCATION OF UTILITY AND DRAINAGE EASEMENTS, | | | OVERHEAD LINES, WATER METERS, TRANSFORMERS, CHECK | | | VALVES, CLEAN OUTS, FIRE HYDRANTS, LIGHT POLES, ETC. | | | THAT MAY IMPACT LANDSCAPING. | | | 3.4. TABULATION TABLE INDICATING HOW THE EXISTING AND | | | PROPOSED PLANT MATERIAL COMPLIES WITH ARTICLE XIV. | | | 3.5. SPECIES, QUANTITY, HEIGHT, SPREAD, SPACING, AND | | | LOCATION OF THE EXISTING AND PROPOSED PLANT MATERIAL. | | | 3.6. STATEMENT THAT ALL LANDSCAPE AREAS WILL BE | | | PROVIDED WITH A PERMANENT AUTOMATIC IRRIGATION SYSTEM, | | | INCLUDING THE ADJACENT RIGHT-OF-WAY (PLEASE NOTE THAT | | | ANY NEW IRRIGATION SHALL BE DONE UNDER A SEPARATE | | | PERMIT). | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-06-17 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2022-06-17 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2022-06-17 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2022-06-17 15:43:03 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 06.17.2022 | | | PERMIT NO.: 21100714 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. [ NOT SATISFIED ] - CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. | | | | | | 2. [ SATISFIED ] - A SITE PLAN SHALL BE PROVIDED. SITE | | | PLAN SHALL INCLUDE: | | | 2.1. DATE, NORTH ARROW, AND A GRAPHIC SCALE. | | | 2.2. VICINITY MAP SHOWING THE PROPERTY IN RELATION TO | | | THE SURROUNDING AREA. | | | 2.3. LOCATION OF THE PROPERTY LINE, RIGHT-OF-WAY, | | | PROPOSED/EXISTING EASEMENTS, WATER COURSES AND OTHER | | | ESSENTIAL FEATURES. | | | 2.4. STREETS, DRIVEWAYS, INTERSECTIONS, CURBS CUTS AND | | | TURNING LANES ADJACENT TO OR ACROSS FROM THE SUBJECT | | | PROPERTY. | | | 2.5. THE OUTLINES OF ALL BUILDINGS WITH USES, | | | SETBACKS, DIMENSIONS, FLOOR AREA, NUMBER OF STORIES, | | | HEIGHT AND POINTS OF ACCESS. | | | 2.6. LOCATION AND DIMENSIONS OF ALL PERIMETER | | | TREATMENT (SIDEWALKS, FENCES, WALLS, OR BERMS). | | | 2.7. MEANS OF VEHICULAR AND PEDESTRIAN ACCESS TO AND | | | FROM THE SITE. | | | 2.8. LAYOUT AND LOCATION OF ALL OFF-STREET PARKING, | | | LOADING AND OTHER VEHICULAR USE AREAS, INCLUDING WHERE | | | APPLICABLE, THE DISTANCE FROM THE PRINCIPLE USES. | | | | | | 3. [ NOT SATISFIED ] - PURSUANT TO SECTION 94-441 OF | | | THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS | | | (ZLDRS), BECAUSE THE PROPOSED SCOPE OF WORK EXCEEDS 50 | | | PERCENT OF THE VALUE OF THE EXISTING STRUCTURE, THE | | | SITE SHALL BE BROUGHT INTO COMPLIANCE WITH ARTICLE XIV | | | (LANDSCAPING) OF THE ZLDRS. PLANS SHALL BE SUBMITTED | | | INDICATING SUCH. IF EXISTING MATERIAL IS SHOWN ON THE | | | PLANS AND ALL PROVISIONS OF ARTICLE XIV HAVE BEEN MET, | | | THEN NO ADDITIONAL PERMIT/INSTALLATION IS REQUIRED. IF | | | THE EXISTING MATERIAL ON SITE DOES NOT CONFORM TO ALL | | | OF THE REQUIREMENTS OF ARTICLE XIV, THEN ADDITIONAL | | | MATERIAL WILL NEED TO BE SHOWN ON THE PLANS AND | | | PERMITTED UNDER A LANDSCAPE PERMIT. PLEASE NOTE THAT | | | PLANS SHOULD INCLUDE, BUT NOT BE LIMITED TO, THE | | | FOLLOWING: | | | 3.1. THE LOCATION OF ALL EXISTING AND PROPOSED | | | STRUCTURES, IMPROVEMENTS, ETC. | | | 3.2. THE LOCATION OF ALL EXISTING AND PROPOSED TREES, | | | SHRUBS, GROUND COVERS, ETC. | | | 3.3. THE LOCATION OF UTILITY AND DRAINAGE EASEMENTS, | | | OVERHEAD LINES, WATER METERS, TRANSFORMERS, CHECK | | | VALVES, CLEAN OUTS, FIRE HYDRANTS, LIGHT POLES, ETC. | | | THAT MAY IMPACT LANDSCAPING. | | | 3.4. TABULATION TABLE INDICATING HOW THE EXISTING AND | | | PROPOSED PLANT MATERIAL COMPLIES WITH ARTICLE XIV. | | | 3.5. SPECIES, QUANTITY, HEIGHT, SPREAD, SPACING, AND | | | LOCATION OF THE EXISTING AND PROPOSED PLANT MATERIAL. | | | 3.6. STATEMENT THAT ALL LANDSCAPE AREAS WILL BE | | | PROVIDED WITH A PERMANENT AUTOMATIC IRRIGATION SYSTEM, | | | INCLUDING THE ADJACENT RIGHT-OF-WAY (PLEASE NOTE THAT | | | ANY NEW IRRIGATION SHALL BE DONE UNDER A SEPARATE | | | PERMIT). | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-04-29 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-04-29 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-04-29 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2022-04-29 14:46:34 | PLEASE ADDRESS LANDSCAPE COMMENTS, REQUIRES SEPERATE | | | LANDSCAPE PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-12-22 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-12-22 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-12-22 11:29:03 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 12.22.2021 | | | PERMIT NO.: 21100714 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. CURRENT AND ACCURATE SURVEY SHALL BE PROVIDED. | | | | | | 2. A SITE PLAN SHALL BE PROVIDED. SITE PLAN SHALL | | | INCLUDE: | | | 2.1. DATE, NORTH ARROW, AND A GRAPHIC SCALE. | | | 2.2. VICINITY MAP SHOWING THE PROPERTY IN RELATION TO | | | THE SURROUNDING AREA. | | | 2.3. LOCATION OF THE PROPERTY LINE, RIGHT-OF-WAY, | | | PROPOSED/EXISTING EASEMENTS, WATER COURSES AND OTHER | | | ESSENTIAL FEATURES. | | | 2.4. STREETS, DRIVEWAYS, INTERSECTIONS, CURBS CUTS AND | | | TURNING LANES ADJACENT TO OR ACROSS FROM THE SUBJECT | | | PROPERTY. | | | 2.5. THE OUTLINES OF ALL BUILDINGS WITH USES, SETBACKS, | | | DIMENSIONS, FLOOR AREA, NUMBER OF STORIES, HEIGHT AND | | | POINTS OF ACCESS. | | | 2.6. LOCATION AND DIMENSIONS OF ALL PERIMETER TREATMENT | | | (SIDEWALKS, FENCES, WALLS, OR BERMS). | | | 2.7. MEANS OF VEHICULAR AND PEDESTRIAN ACCESS TO AND | | | FROM THE SITE. | | | 2.8. LAYOUT AND LOCATION OF ALL OFF-STREET PARKING, | | | LOADING AND OTHER VEHICULAR USE AREAS, INCLUDING WHERE | | | APPLICABLE, THE DISTANCE FROM THE PRINCIPLE USES. | | | | | | 3. PURSUANT TO SECTION 94-441 OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS), BECAUSE THE | | | PROPOSED SCOPE OF WORK EXCEEDS 50 PERCENT OF THE VALUE | | | OF THE EXISTING STRUCTURE, THE SITE SHALL BE BROUGHT | | | INTO COMPLIANCE WITH ARTICLE XIV (LANDSCAPING) OF THE | | | ZLDRS. PLANS SHALL BE SUBMITTED INDICATING SUCH. IF | | | EXISTING MATERIAL IS SHOWN ON THE PLANS AND ALL | | | PROVISIONS OF ARTICLE XIV HAVE BEEN MET, THEN NO | | | ADDITIONAL PERMIT/INSTALLATION IS REQUIRED. IF THE | | | EXISTING MATERIAL ON SITE DOES NOT CONFORM TO ALL OF | | | THE REQUIREMENTS OF ARTICLE XIV, THEN ADDITIONAL | | | MATERIAL WILL NEED TO BE SHOWN ON THE PLANS AND | | | PERMITTED UNDER A LANDSCAPE PERMIT. PLEASE NOTE THAT | | | PLANS SHOULD INCLUDE, BUT NOT BE LIMITED TO, THE | | | FOLLOWING: | | | 3.1. THE LOCATION OF ALL EXISTING AND PROPOSED | | | STRUCTURES, IMPROVEMENTS, ETC. | | | 3.2. THE LOCATION OF ALL EXISTING AND PROPOSED TREES, | | | SHRUBS, GROUND COVERS, ETC. | | | 3.3. THE LOCATION OF UTILITY AND DRAINAGE EASEMENTS, | | | OVERHEAD LINES, WATER METERS, TRANSFORMERS, CHECK | | | VALVES, CLEAN OUTS, FIRE HYDRANTS, LIGHT POLES, ETC. | | | THAT MAY IMPACT LANDSCAPING. | | | 3.4. TABULATION TABLE INDICATING HOW THE EXISTING AND | | | PROPOSED PLANT MATERIAL COMPLIES WITH ARTICLE XIV. | | | 3.5. SPECIES, QUANTITY, HEIGHT, SPREAD, SPACING, AND | | | LOCATION OF THE EXISTING AND PROPOSED PLANT MATERIAL. | | | 3.6. STATEMENT THAT ALL LANDSCAPE AREAS WILL BE | | | PROVIDED WITH A PERMANENT AUTOMATIC IRRIGATION SYSTEM, | | | INCLUDING THE ADJACENT RIGHT-OF-WAY (PLEASE NOTE THAT | | | ANY NEW IRRIGATION SHALL BE DONE UNDER A SEPARATE | | | PERMIT). | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|