Plan Review Details - Permit 21100604
Plan Review Stops For Permit 21100604
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-12-03 Cont ID  
Sent By shill Date 2021-12-03 Time 10:51 Rev Time 0.00
Received By shill Date 2021-12-03 Time 10:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-26 Cont ID  
Sent By shill Date 2021-10-26 Time 14:51 Rev Time 0.00
Received By shill Date 2021-10-26 Time 14:50 Sent To  
Notes
2021-10-26 14:56:42****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 311, 314, 315, REVISE PLAN TO SHOW ROOM
 DESIGNATION. IT APPEARS THAT THIS CANNOT BE A SLEEPING
 ROOM BECAUSE THE WINDOWS DO NOT APPEAR TO MEET
 EMERGENCY ESCAPE AND RESCUE OPENING REQUIREMENTS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-11 Cont ID  
Sent By jleahy Date 2021-12-11 Time 12:49 Rev Time 0.00
Received By jleahy Date 2021-12-11 Time 12:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-11-03 Cont ID  
Sent By jleahy Date 2021-11-03 Time 14:13 Rev Time 0.00
Received By jleahy Date 2021-11-03 Time 14:11 Sent To  
Notes
2021-11-03 14:17:50ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) FBC R314 SMOKE ALARM IS REQUIRED PER FBC.
  
 PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER
 CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE
 EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC
 R314.3, FBC 107.2.1
  
 2) LIGHTING OUTLET IS REQUIRED BY 210.70 OF THE NEC
  
 210.70(A)(1) HABITABLE ROOMS. AT LEAST ONE WALL
 SWITCH?CONTROLLED
 LIGHTING OUTLET SHALL BE INSTALLED IN EVERY HABITABLE
 ROOM,
 KITCHEN, AND BATHROOM.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-11 Cont ID  
Sent By jleahy Date 2021-12-11 Time 12:49 Rev Time 0.00
Received By jleahy Date 2021-11-30 Time 16:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-03 Cont ID  
Sent By jleahy Date 2021-11-03 Time 14:18 Rev Time 0.00
Received By jleahy Date 2021-10-27 Time 06:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-12-06 Cont ID  
Sent By medwards Date 2021-12-06 Time 06:12 Rev Time 0.00
Received By medwards Date 2021-12-06 Time 06:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-12-03 Cont ID  
Sent By shill Date 2021-12-03 Time 10:58 Rev Time 0.00
Received By shill Date 2021-12-03 Time 10:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-11-03 Cont ID  
Sent By jleahy Date 2021-11-03 Time 14:18 Rev Time 0.00
Received By jleahy Date 2021-11-03 Time 14:18 Sent To  
Notes
2021-11-03 14:19:10PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE DESIGN
 PROFESSIONAL RESPONSIBLE FOR THE DESIGN. FBC 107.2.1,
 FS 471, 481