Plan Review Details - Permit 21100583
| Plan Review Stops For Permit 21100583 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-02-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-02 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-02 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-26 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-26 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2022-01-26 15:54:39 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE THE FOLLOWING INFORMATION | | | RELATED TO THE PRODUCT APPROVALS: | | | | | | 1.) THE INSTALLATION INSTRUCTIONS ARE MISSING FOR THE | | | HORIZONTAL SLIDING WINDOW (PRODUCT APPROVAL #20359 R3) | | | 2.) THE EVALUATION REPORTS ARE MISSING FOR ALL THREE | | | PRODUCT APPROVALS: THE HORIZONTAL SLIDING WINDOWS | | | (PRODUCT APPROVAL #20359 R3), THE SINGLE HUNG WINDOW | | | (PRODUCT APPROVAL #20352.1), & THE SWINGING DOORS | | | (PRODUCT APPROVAL #26942). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-04 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-04 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2021-12-04 11:45:29 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, PROVIDE THE COMPLETE FLORIDA PRODUCT | | | APPROVAL COVER SHEET FOR EACH PRODUCT. A COMPLETE | | | PRODUCT APPROVAL SHOULD INCLUDE: | | | | | | THE COVER SHEET WHICH SHOWS THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS | | | EVALUATION REPORT | | | INSTALLATION INSTRUCTIONS | | | | | | FOR SOME PRODUCT APPROVALS, THE EVALUATION REPORT AND | | | INSTALLATION INSTRUCTIONS ARE ONE DOCUMENT. | | | | | | ***IT IS PREFERABLE THAT YOU UPLOAD THE COVER PAGE, | | | EVALUATION REPORT, AND INSTALLATION INSTRUCTIONS AS ONE | | | PDF. *** | | | | | | THESE DOCUMENTS ARE AVAILABLE AT FLORIDABUILDING.ORG. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-26 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-07 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-04 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-11-16 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-04 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-04 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
|