Plan Review Details - Permit 21100386
Plan Review Stops For Permit 21100386
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-12-07 Cont ID  
Sent By pvalenti Date 2021-12-07 Time 14:33 Rev Time 0.00
Received By pvalenti Date 2021-12-07 Time 13:18 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-11-19 Cont ID  
Sent By pvalenti Date 2021-11-19 Time 12:23 Rev Time 0.00
Received By pvalenti Date 2021-11-19 Time 11:44 Sent To  
Notes
2021-11-19 12:27:40PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 ASBESTOS REVIEW DENIED, AN ACKNOWLEDGEMENT LETTER IS
 ALL THAT'S REQUIRED. PLEASE SEE THE COMMENT BELOW.
  
 FAILED PLAN REVIEW, COMMERCIAL:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-12-07 Cont ID  
Sent By pvalenti Date 2021-12-07 Time 14:33 Rev Time 0.00
Received By pvalenti Date 2021-12-07 Time 13:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-11-19 Cont ID  
Sent By pvalenti Date 2021-11-19 Time 12:09 Rev Time 0.00
Received By pvalenti Date 2021-11-19 Time 11:45 Sent To  
Notes
2021-11-19 12:16:23PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 1.) THE SUBMITTED FLOORING UNDERLAYMENT TEST REPORTS
 ARE FOR UNITS THAT HAVE SUSPENDED CEILINGS. THAT IS
 TYPICALLY NOT THE CASE IN WEST PALM BEACH. WE WILL NEED
 THE TEST REPORTS FOR UNITS WITH OUT SUSPENDED CEILING
 AND PLEASE SELECT THE (ONE ONLY) SELECTED UNDERLAYMENT
 OPTION THAT YOU WILL BE USING UNLESS YOU WILL BE USING
 DIFFERENT UNDERLAYMENTS FOR DIFFERENT AREAS.
 2.) THE GENERAL CONTRACTOR NEEDS TO SIGN THE PLANS THAT
 FALL UNDER THE CONTRACTOR'S SCOPE OF WORK.
  
 NOTE: THE INFORMATION AS TO THIS BEING A PRIVATE
 PROVIDER JOB FOR EITHER INSPECTIONS, PLAN REVIEW, OR
 BOTH IS NOT CLEAR. PLEASE CLARIFY THIS INFORMITION
 WITHIN THE PRIVATE PROVIDER REVIEW STOP AS PER PRIVATE
 PROVIDER REVIEW STOP RESULTS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-09 Cont ID  
Sent By jleahy Date 2021-12-09 Time 08:46 Rev Time 0.00
Received By jleahy Date 2021-12-09 Time 08:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-11-17 Cont ID  
Sent By jleahy Date 2021-11-17 Time 12:53 Rev Time 0.00
Received By jleahy Date 2021-11-17 Time 12:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-12-10 Cont ID  
Sent By   Date 2021-12-10 Time   Rev Time 0.00
Received By bdolan Date 2021-12-10 Time 10:06 Sent To  
Notes
2021-12-10 10:07:28REVISION PASS FIRE
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-11-01 Cont ID  
Sent By   Date 2021-11-01 Time   Rev Time 0.00
Received By bdolan Date 2021-11-01 Time 12:46 Sent To  
Notes
2021-11-01 12:50:09FIRE DEPARTMENT HAS NO OBJECTIONS TO THE PROJECT.
  
 ALL WORK IS SUBJECT TO FIELD INSPECTION.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-13 Cont ID  
Sent By lmarchan Date 2021-12-13 Time 09:58 Rev Time 0.00
Received By lmarchan Date 2021-12-07 Time 09:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-19 Cont ID  
Sent By pvalenti Date 2021-11-19 Time 12:38 Rev Time 0.00
Received By pvalenti Date 2021-10-29 Time 06:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-11-05 Cont ID  
Sent By medwards Date 2021-11-05 Time 14:15 Rev Time 0.00
Received By medwards Date 2021-11-05 Time 14:15 Sent To  
Notes
2021-11-05 14:16:41NO MECHANICAL WORK SHOWN FOR THIS PROJECT. ME

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-12-08 Cont ID  
Sent By ccole Date 2021-12-08 Time 13:42 Rev Time 0.00
Received By ccole Date 2021-12-08 Time 11:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By ccole Date 2021-11-10 Time 15:13 Rev Time 0.00
Received By ccole Date 2021-11-10 Time 13:29 Sent To  
Notes
2021-11-10 15:13:481ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21100386
 11/10/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) P101: PROVIDE AN EQUIPMENT SCHEDULE FOR THE WATER
 HEATER AND SUBMIT MANUFACTURER?S SPECIFICATIONS AND THE
 INSTALLATION MANUAL. THE SCHEDULE SHALL INDICATE THE
 TYPE OF WATER HEATER- GAS OR ELECTRIC, TANK OR
 TANKLESS, GALLON SIZE FOR TANK, AND THE EFFICIENCY
 RATING BASED ON TABLE C404.2 FBC EC.
  
 2) P101: PLEASE PLACE A NOTE ON THE PLAN INDICATING THE
 PLUMBING STACK REPLACEMENTS WILL BE DONE UNDER SEPARATE
 PERMIT- SECTION 105.1 & 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2021-12-02 Cont ID  
Sent By dbattles Date 2021-12-02 Time 16:18 Rev Time 0.00
Received By dbattles Date 2021-12-02 Time 16:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-12-07 Cont ID  
Sent By pvalenti Date 2021-12-07 Time 14:34 Rev Time 0.00
Received By pvalenti Date 2021-12-07 Time 13:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-11-19 Cont ID  
Sent By pvalenti Date 2021-11-19 Time 12:34 Rev Time 0.00
Received By pvalenti Date 2021-11-19 Time 11:45 Sent To  
Notes
2021-11-17 12:53:58ELECTRICAL PLAN IS OK JL