Plan Review Details - Permit 21100379
Plan Review Stops For Permit 21100379
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2023-04-04 Cont ID  
Sent By jgomez Date 2023-04-04 Time 09:43 Rev Time 0.00
Received By jgomez Date 2023-04-03 Time 18:38 Sent To  
Notes
2023-04-04 09:44:01BUILDING REVIEW APPROVED WITH PROVISO:
 1- REVISE "CONSTRUCTION DRAWINGS" ELEVATION
 CERTIFICATE: A) THE LATITUDE SPECIFIED ON ITEM A5 NEED
 TO PROVIDE AT LEAST 5 DECIMAL PLACES OR BETTER AS
 REQUIRED BY THEE FEMA ELEVATION CERTIFICATE PUBLISHED
 INSTRUCTIONS. B)GARAGE SQUARE FOOTAGE DOESN'T MATCH
 PLANS. C)REVISE TOTAL NET AREA OF FLOOD OPENINGS TO
 MATCH PLANS AND PRODUCT APPROVAL. D)THE BASE FLOOD
 ELEVATION SPECIFIED ON ITEM B9 IS INCORRECT. E)ATTACHED
 GARAGE ELEVATION SPECIFIED ON ITEM C2(D) TO MATCH PLANS
 ENGINEER OF RECORD PLANS. F)LOWEST ADJACENT (FINISHED)
 GRADE AND HIGHEST ADJACENT (FINISHED) GRADE ARE NO
 SHOWN ON SURVEY WITH PROPOSED STRUCTURE. UNABLE TO
 VERIFY. G)SURVEYOR NEEDS TO DATE ELEVATION CERTIFICATE
 WITH CURRENT DATE. ELEVATION CERTIFICATE WAS REVISED
 BUT SAME DATE WAS SHOWN.
  
 2- PRODUCT APPROVAL DEFERRAL: A)INSWING ENTRY DOORS.
 B)INSWING SIDE DOOR #4. C)SLIDING GLASS DOORS.
 D)OVERHEAD GARAGE DOOR. E)CASEMENT WINDOWS. F)SINGLE
 HUNG WINDOWS. G)FIXED WINDOWS. H)HORIZONTAL ROLLER
 WINDOWS. I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY
 MULLION SIZE. J)HURRICANE SHUTTERS IF DOORS AND WINDOWS
 DON'T HAVE IMPACT GLAZING. AND, PROVIDE COMPLETE
 INSTALLATION SCHEDULE. K)SHINGLES. L)PEEL & STICK
 SHINGLES UNDERLAYMENT SPECIFIED ON PLANS.
 M)RIDGE VENTS AS SPECIFIED ON PLANS. N)FLOOD VENTS AS
 SPECIFIED ON PLANS.
  
 3- ENGINEER OF RECORD TO SPECIFY PROPOSED FINISH FLOOR
 ELEVATION OF GARAGE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2023-03-31 Cont ID  
Sent By jgomez Date 2023-03-31 Time 14:07 Rev Time 0.00
Received By jgomez Date 2023-03-31 Time 13:41 Sent To  
Notes
2023-03-31 14:07:16RESIDENTIAL(R3) ADDITION, ALTERATION 5TH BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21100379
 102 GREGORY RD
  
 PROVISO NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY (EXCEPT FOR
 PRODUCT APPROVALS DEFERRED SUBMITTAL).
  
 ***IMPORTANT
 ****CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED
 AT THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION
 BEFORE PERMIT ISSUANCE.
  
  
 1(B)- ELEVATION CERTIFICATE SUBMITTED:
 PREVIOUS COMMENT:
 (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS
 INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL
 AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 UNABLE TO VERIFY INFORMATION. FLOOD VENT PRODUCT
 APPROVAL WAS NOT SUBMITTED.
  
 PREVIOUS COMMENT:
 (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS
 INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND
 REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT REVISED.
  
 PREVIOUS COMMENT:
 (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS
 INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 UNABLE TO VERIFY INFORMATION. ENGINEER OF RECORD ERASED
 PROPOSED GARAGE ELEVATION.
  
 (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST
 ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED
 SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED.
 RESPONSE:
 UNABLE TO CONFIRM INFORMATION WITH SURVEY WITH PROPOSED
 STRUCTURE SUBMITTED. SURVEY DOESN'T SHOW THE EXTERIOR
 GRADE ELEVATIONS SHOWN ON ELEVATION CERTIFICATE.
 NOTE: COORDINATE WITH DRAINAGE PLAN. TO AVOID
 CONFITS/DELAYS.
 SEC.107.2.1 CITY AMENDMENTS.
  
 15- PRODUCT APPROVALS WILL BE A DEFFERRED SUBMITTAL
 AFTER THE PERMIT IS ISSUED.
  A)INSWING ENTRY DOORS A SHOWN ON PLANS.
  B)INSWING SIDE DOOR #4 AS SHOWN ON PLANS.
  C)SLIDING GLASS DOORS (NOTE: NEED FOR LARGE MISSILE
 IMPACT)
  D)OVERHEAD GARAGE DOOR.
  E)CASEMENT WINDOWS.
  F)SINGLE HUNG WINDOWS.
  G)FIXED WINDOWS.
  H)HORIZONTAL ROLLER
  WINDOWS.
  I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY
  MULLION SIZE TO AVOID DELAYS/CONFLICTS).
  J)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT
  GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE.
  K)SHINGLES.
  L)PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON
 PLANS.
  M)RIDGE VENTS AS SPECIFIED ON PLANS.
  N)FLOOD VENTS AS SPECIFIED ON PLANS.
  
 NEW COMMENTS BASED ON REVISED PLANS:
 16- ENGINEER OF RECORD TO SPECIFY PROPOSED FINISH FLOOR
 ELEVATION OF GARAGE. NOTE: INFORMATION WAS SUBMITTED
 BEFORE, BUT IT GOT ERASED ON RESUBMITTED PLANS. NEED
 INFORMATION TO CHECK/VERIFY CONSTRUCTION DRAWINGS
 ELEVATION CERTIFICATE SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
 *****************************
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-10-26 Cont ID  
Sent By jgomez Date 2022-10-26 Time 18:19 Rev Time 0.00
Received By jgomez Date 2022-10-26 Time 13:59 Sent To  
Notes
2022-10-26 18:19:50RESIDENTIAL (R3) ADDITION, ALTERATION 4TH BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21100379
 102 GREGORY RD
  
 PREVIOUS COMMENT:
 1- REPEAT COMMENT. THREE TIMES. NOT ADDRESSED AT ALL.
 NEED TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE AND SURVEY FOR REVIEW.
  
 RESPONSE:
 A) SURVEY SUBMITTED IS FOR THE OLD HOUSE AND GARAGE.
 NEED SURVEY WITH PROPOSED CONSTRUCTION IN ORDER TO
 REVIEW ELEVATION CERTIFICATE SUBMITTED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 B)ELEVATION CERTIFICATE SUBMITTED:
 (1) BUILDING OWNER'S NAME IS INCORRECT. REVISE AS
 REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (2)PROPERTY LEGAL DESCRIPTION DOESN'T MATCH INFORMATION
 SHOWN ON THE SURVEY SUBMITTED. REVISE AS REQUIRED TO
 MATCH.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (3)BUILDING DIAGRAM NUMBER ON ITEM A7 IS INCORRECT.
 REVISE AS REQUIRED. SEE FEMA ELEVATION CERTIFICATE
 INSTRUCTIONS AND REVISE AS REQUIRED. IT LOOKS LIKE THIS
 IS DIAGRAM NUMBER 1B NOT 7.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS
 INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL
 AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS
 INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND
 REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (6)TOP OF BOTTOM FLOOR ELEVATION SPECIFIED ON ITEM
 C2(A) IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS
 INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (8)LOWEST ELEVATION OF AIR CONDITIONING UNIT SPECIFIED
 ON ITEM C2(E) DOESN'T COMPLY WITH CITY ORDINANCE
 4729-17.ELEVATION OF EQUIPMENT NEEDS TO BE 2 FEET ABOVE
 THE BASE FLOOD ELEVATION (9'-0" MIN.). COORDINATE WITH
 ENGINEER OF RECORD AND REVISE AS REQUIRED.
  
 (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST
 ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED
 SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED.
  
  
 PREVIOUS COMMENT:
 2- DRAINAGE PLAN SUBMITTED IS FOR THE EXISTING
 STRUCTURES. NEED TO PROVIDE DRAINAGE PLAN WITH PROPOSED
 STRUCTURES.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 PREVIOUS COMMENT:
 15- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. CONTRACTOR TO ADVISE IF SUBMITTING NOW OR
 LATER AS A DEFERRED SUBMITTAL).
  
  A)INSWING ENTRY DOORS A SHOWN ON PLANS.
  B)INSWING SIDE DOOR #4 AS SHOWN ON PLANS.
  C)SLIDING GLASS DOORS (NOTE: NEED FOR LARGE MISSILE
 IMPACT)
  D)OVERHEAD GARAGE DOOR.
  E)CASEMENT WINDOWS.
  F)SINGLE HUNG WINDOWS.
  G)FIXED WINDOWS.
  H)HORIZONTAL ROLLER
  WINDOWS.
  I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY
  MULLION SIZE TO AVOID DELAYS/CONFLICTS).
  J)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT
  GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE.
  K)SHINGLES.
  L)PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON
 PLANS.
  M)RIDGE VENTS AS SPECIFIED ON PLANS.
  N)FLOOD VENTS AS SPECIFIED ON PLANS.
  
 RESPONSE:
 ACCORDING TO ENGINEER OF RECORD RESPONSE LETTER ALL
 PRODUCT APPROVALS WILL BE APPROVED AND WILL BE
 SUBMITTED LATER AS DEFERRED SUBMITTALS.
 ONLY SOME PRODUCT APPROVALS WERE SUBMITTED AT THIS TIME
 AND THEY WERE NOT REVIEWED/APPROVED BY THE DESIGNER OF
 RECORD. ALSO, THE FLOOD VENT PRODUCT APPROVAL SUBMITTED
 IS INCOMPLETE. IT NEEDS THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND INSTALLATION INSTRUCTIONS. TO SAVE TIME,
 ALL PRODUCT APPROVALS SUBMITTED THIS TIME WILL BE
 BLOCKED AND WILL NOT BE REVIEWED AT THIS TIME.
 CONTRACTOR TO ADVISE IF SUBMITTING ALL THE PRODUCT
 APPROVALS (COMPLETE REPORTS) LATER AS A DEFERRED
 SUBMITTAL ONCE THEY ARE APPROVED BY THE DESIGNER OF
 RECORD OR IF SUBMITTING THEM ON NEXT RESUBMITTAL.
  
 NEW COMMENT BASED ON REVISED PLANS:
 16- SHEET A-2: ENGINEER REVISED THE BASE FLOOD
 ELEVATION UNDER FLOOD ZONE. THE REVISED INFORMATION IS
 INCORRECT. ACCORDING TO FLOOD INSURANCE RATE MAP (FIRM)
 DATED 10-05-2017 THE BASE FLOOD ELEVATION IS 7'-0" NOT
 6'-0". REVISE AS REQUIRED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-07-19 Cont ID  
Sent By jgomez Date 2022-07-19 Time 13:00 Rev Time 0.00
Received By jgomez Date 2022-07-18 Time 17:23 Sent To  
Notes
2022-07-19 13:00:32RESIDENTIAL (R3) ADDITION, ALTERATION THIRD BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21100379
  
 PREVIOUS COMMENT:
 1- NFIP COMMENTS WILL RESOLVE THIS COMMENT.
  NOTE: DURING THE PERMITTING OF THIS STRUCTURE THREE
 DIFFERENT
  FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
  A) CONSTRUCTION DRAWINGS.
  B) BUILDING UNDER CONSTRUCTION.
  C) FINISHED CONSTRUCTION.
  
 RESPONSE:
 REPEAT COMMENT. THREE TIMES. NOT ADDRESSED AT ALL. NEED
 TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION CERTIFICATE
 AND SURVEY FOR REVIEW.
  
 PREVIOUS COMMENT:
 2- LOT DRAINAGE
 2ND REVIEW NO DRAINAGE PLAN WAS ADDED. PLEASE ADD
 DRAWING OR NOTES TO SATISFY DRAINAGE
  PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
  FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY
  AMENDMENTS. SEC. 110.9 CITY AMENDMENTS. NOTE:
 DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED GRADE
 ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
  ADJACENT PROPERTIES.
  
 RESPONSE:
 DRAINAGE PLAN SUBMITTED IS FOR THE EXISTING STRUCTURES.
 NEED TO PROVIDE DRAINAGE PLAN WITH PROPOSED STRUCTURES.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 PREVIOUS COMMENT:
 15- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001
  FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
  SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
  PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
  PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
  DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  A)INSWING ENTRY DOORS A SHOWN ON PLANS.
  B)INSWING SIDE DOOR #4 AS SHOWN ON PLANS.
  C)SLIDING GLASS DOORS (NOTE: NEED FOR LARGE MISSILE
 IMPACT)
  D)OVERHEAD GARAGE DOOR.
  E)CASEMENT WINDOWS.
  F)SINGLE HUNG WINDOWS.
  G)FIXED WINDOWS.
  H)HORIZONTAL ROLLER
  WINDOWS.
  I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY
  MULLION SIZE TO AVOID DELAYS/CONFLICTS).
  J)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT
  GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE.
  K)SHINGLES.
  L)PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON
 PLANS.
  M)RIDGE VENTS AS SPECIFIED ON PLANS.
  N)FLOOD VENTS AS SPECIFIED ON PLANS.
  
 RESPONSE:
 ACCORDING TO ENGINEER OF RECORD RESPONSE LETTER ALL
 PRODUCT APPROVALS WILL BE APPROVED AND WILL BE
 SUBMITTED LATER AS DEFERRED SUBMITTALS.
  
  WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
  ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
  THE REVISION MADE, IDENTIFYING THE SHEET OR
  SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
  HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
  ANTICIPATED COOPERATION.
  
  PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
  QUESTIONS REGARDING THESE COMMENTS,
  JULIO GOMEZ
  COMMERCIAL COMBINATION PLANS EXAMINER
  DEVELOPMENT SERVICES DEPARTMENT
  BUILDING DIVISION
  (561)805-6712
  [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-05-09 Cont ID  
Sent By dbattles Date 2022-05-09 Time 08:49 Rev Time 0.00
Received By dbattles Date 2022-05-06 Time 09:50 Sent To  
Notes
2022-05-09 09:04:15 
 2ND REVIEW COMPLETED 5/9/22
 DYLAN BATTLES
 [email protected]
 561-805-6718
 BUILDING PLANS EXAMINER - LICENSE PX4191
  
 RESIDENTIAL (R3) ADDITION, ALTERATION BUILDING REVIEW
  COMMENTS
  CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
  PERMIT #21100379
  
  NOTE:
  SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
  FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
  COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
  REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
  1- NFIP COMMENTS WILL RESOLVE THIS COMMENT.
  
  NOTE: DURING THE PERMITTING OF THIS STRUCTURE THREE
 DIFFERENT
  FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
  A) CONSTRUCTION DRAWINGS.
  B) BUILDING UNDER CONSTRUCTION.
  C) FINISHED CONSTRUCTION.
  
  2- LOT DRAINAGE
 2ND REVIEW NO DRAINAGE PLAN WAS ADDED. PLEASE ADD
 DRAWING OR NOTES TO SATISFY DRAINAGE
  PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
  FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY
  AMENDMENTS.
  SEC. 110.9 CITY AMENDMENTS.
  NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
  GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
  ADJACENT PROPERTIES.
  
  
  
  
  
  13- ENGINEER TO CLARIFY REQUIRED SOIL BEARING
 CAPACITY.
  SOME NOTES SPECIFY 2,000PSF, WHILE SOME OTHER NOTES ON
  SAME PLANS SUBMITTED SPECIFY 2,500PSF. REVISE AS
  REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
  
  15- PRODUCT APPROVALS
 2ND REVIEW VERIFY WHAT PRODUCT APPROVALS ARE TO BE
 DEFERRED. WE STILL NEED GARAGE DOOR, CASEMENET WINDOW,
 FIXED WINDOW, SWING DOOR AND FRENCH DOOR.
  PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001
  FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
  SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
  PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
  PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
  DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  A)INSWING ENTRY DOORS A SHOWN ON PLANS. B)INSWING SIDE
  DOOR #4 AS SHOWN ON PLANS. C)SLIDING GLASS DOORS.
  D)OVERHEAD GARAGE DOOR. E)CASEMENT WINDOWS. F)SINGLE
  HUNG WINDOWS. G)FIXED WINDOWS. H)HORIZONTAL ROLLER
  WINDOWS. I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY
  MULLION SIZE TO AVOID DELAYS/CONFLICTS). J)HURRICANE
  SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT
  GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE.
  SEE CITY SAMPLE. K)SHINGLES. L)PEEL & STICK SHINGLES
  UNDERLAYMENT SPECIFIED ON PLANS. M)RIDGE VENTS AS
  SPECIFIED ON PLANS. N)FLOOD VENTS AS SPECIFIED ON
  PLANS.
  
  16- ENGINEER OF RECORD TO REVIEW AND APPROVE IN
 WRITING
  (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
  REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
  
  
  20) NEED SEPARATE DEMOLITION PERMIT FOR DETACHED
 GARAGE
  AND EXISTING HOUSE PARTIAL DEMOLITION. SEC. 105.1 CITY
  AMENDMENTS.
 2ND REVIEW. NO APPLICATION IN SYSTEM FOR DEMO PERMIT
  
  WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
  ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
  THE REVISION MADE, IDENTIFYING THE SHEET OR
  SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
  HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
  ANTICIPATED COOPERATION.
  
  PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
  QUESTIONS REGARDING THESE COMMENTS,
  JULIO GOMEZ
  COMMERCIAL COMBINATION PLANS EXAMINER
  DEVELOPMENT SERVICES DEPARTMENT
  BUILDING DIVISION
  (561)805-6712
  [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By jgomez Date 2021-12-03 Time 13:40 Rev Time 0.00
Received By jgomez Date 2021-12-03 Time 10:00 Sent To  
Notes
2021-12-03 13:41:57RESIDENTIAL (R3) ADDITION, ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21100379
  
 NOTE:
 SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 1- THE PROPOSED ADDITION IS GOING TO BE BUILT IN A AE
 FLOOD ZONE WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET
 BASED ON NAVD 88.
 THE PROPOSED ADDITION AND ALTERATION IS CONSIDERED A
 SUBSTANTIAL IMPROVEMENT. THE ADDITION AND THE EXISTING
 HOUSE SHALL HAVE THE LOWEST FLOOR FINISHED ELEVATION
 ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION PLUS TWO
 FEET.
 THEREFORE, THE MIN. REQUIRED FINISHED FLOOR ELEVATION
 IS 9 FEET.
 NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR
 ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS
 ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH
 FLOOR ELEVATIONS FOR REVIEW.
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT
 FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 2- LOT DRAINAGE
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY
 AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 3-PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. 1101.1
 FBC-EXISTING BUILDING AND SEC. R401.4 FBC-RESIDENTIAL.
  
 4-ACCORDING TO SEC. R301.2.1.4.3 FBC-RESIDENTIAL THIS
 BUILDING IS LOCATED IN EXPOSURE "D" NOT "C". REVISE
 BUILDING EXPOSURE AND ALL ROOF AND WALLS DESIGN WIND
 PRESSURES INFORMATION. REVISE BUILDING EXPOSURE ON
 SHEET A-2, A-3 AND ANY OTHER DRAWING SPECIFYING
 EXPOSURE "C".
 NOTE: PRODUCT APPROVALS WILL BE REVIEWED WHEN DESIGN
 PRESSURES ARE REVISED.
  
 5- DESIGNER OF RECORD TO SPECIFY ALL LIVE AND DEAD
 LOADS. CLEARLY SPECIFY ROOF LIVE AND DEAD LOADS (TOP
 AND BOTTOM CHORDS), INCLUDING THE ATTIC LIVE LOAD AS
 REQUIRED BY TABLE R301.5 FBC-RESIDENTIAL. SEE FOOTNOTES
 "B" AND "G".
 NOTE: ENGINEER TO CLARIFY WHY STATING N.A. FOR FLOOR
 LIVE LOAD ON THE DESIGN LOADS ON SHEET A-2.
  
 6-BEDROOM #2 EGRESS WINDOW DOESN'T COMPLY WITH SEC.
 R310.2.1 FBC-RESIDENTIAL. REVISE AS REQUIRED OR PROVIDE
 MANUFACTURER'S CUT SHEETS SHOWING THAT 26"X63" CASEMENT
 WINDOW MEETS THE EGRESS REQUIREMENTS.
  
 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION. SEC. R807.1
 FBC-RESIDENTIAL.
  
 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF HANDRAILS AND GUARDRAILS SHOWING
 COMPLIANCE WITH TABLE R301.5, SEC. R311.7.8 AND SEC.
 R312.1 FBC-RESIDENTIAL.
 NOTE: IF THIS IS A DEFERRED SUBMITTAL, THEN SPECIFY THE
 DESIGN GUIDELINES REQUIRED BY TABLE R301.5, SEC.
 R311.7.8 AND SEC. R312.1 AND CLEARLY SPECIFY ON PLANS
 THAT SHOP DRAWINGS NEED TO BE SUBMITTED FOR REVIEW
 PRIOR TO CONSTRUCTION. ALL SHOP DRAWINGS TO BE REVIEWED
 BY THE DESIGN PROFESSIONAL OF RECORD PRIOR TO SUBMITTAL
 TO THIS OFFICE.
  
 9- REVISE PLYWOOD ROOF SHEATHING NAILING SPACING. ROOF
 SHEATHING NEEDS TO BE NAILED WITH RING SHANK NAILS AT 4
 INCHES O.C. IN THE FIELD AND EDGES AS REQUIRED BY SEC.
 R803.2.3.1 AND TABLE R803.2.3.1 FBC-RESIDENTIAL.
 NOTE: REVISE ALL DRAWINGS NOTES REFERENCING THE ROOF
 SHEATHING THICKNESS AND NAIL SIZE AND SPACING TO AVOID
 CONFLICTS/DELAYS.
  
 10- REVISE WIND ZONE ROOF PLAN ON SHEET A-11 TO COMPLY
 WITH CURRENT CODE ROOF ZONES FIGURE R301.2(7) AND
 REVISE WIND PRESSURES ACCORDINGLY.
 NOTE: BUILDING IS LOCATE IN EXPOSURE "D" NOT "C".
  
 11-PROVIDE SWING DOOR STRUCTURAL BUCK DETAIL SHOWING
 COMPLIANCE WITH SEC. R609.7.2.1 FBC-RESIDENTIAL.
 SPECIFY STRUCTURAL BUCK SIZE AND FASTENING.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 12- ATTIC VENTILATION:
 ATTIC VENT CALCULATIONS ON SHEET A-4 SHOW 20 LINEAR
 FEET OF RIDGE VENTILATION. EXTERIOR ELEVATIONS ONLY
 SHOW 10'-0" OF RIDGE VENTILATION. REVISE AS REQUIRED.
 SEC. R806 FBC-RESIDENTIAL.
  
 13- ENGINEER TO CLARIFY REQUIRED SOIL BEARING CAPACITY.
 SOME NOTES SPECIFY 2,000PSF, WHILE SOME OTHER NOTES ON
 SAME PLANS SUBMITTED SPECIFY 2,500PSF. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 14- ENERGY CALCULATIONS SUBMITTED:
 A)THE ENERGY FORM R405-2020 IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER, ARCHITECT OR OWNER?S LEGALLY
 DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION.
  
 B) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM, INCLUDING OWNER'S NAME, BUILDER'S NAME, CORRECT
 PERMIT OFFICE (CITY OF WEST PALM BEACH NOT PALM BEACH
 COUNTY, CORRECT JURISDICTION NUMBER (JURISDICTION
 NUMBER IS 604700) SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 C)PROVIDE THE NAME (NOT SIGNATURE) OF PERSON PERFORMING
 THE ANALYSIS AND GENERATING THE REPORT AS REQUIRED BY
 SEC. R405.4.2.1 FBC- ENERGY CONSERVATION.
  
 D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 E)CLARIFY WHY THERE ARE NO OCCUPANTS SPECIFIED IN THE
 "SPACES" AREA ON PAGE 2 OF 7. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 15- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
 A)INSWING ENTRY DOORS A SHOWN ON PLANS. B)INSWING SIDE
 DOOR #4 AS SHOWN ON PLANS. C)SLIDING GLASS DOORS.
 D)OVERHEAD GARAGE DOOR. E)CASEMENT WINDOWS. F)SINGLE
 HUNG WINDOWS. G)FIXED WINDOWS. H)HORIZONTAL ROLLER
 WINDOWS. I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY
 MULLION SIZE TO AVOID DELAYS/CONFLICTS). J)HURRICANE
 SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT
 GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE.
 SEE CITY SAMPLE. K)SHINGLES. L)PEEL & STICK SHINGLES
 UNDERLAYMENT SPECIFIED ON PLANS. M)RIDGE VENTS AS
 SPECIFIED ON PLANS. N)FLOOD VENTS AS SPECIFIED ON
 PLANS.
  
 16- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 17- PROVIDE FIRE RATING SPECIFICATIONS OR SPECIFY TYPE
 OF SOLID DOOR FOR GARAGE DOOR LEADING TO THE INTERIOR
 OF THE HOUSE SHOWING COMPLIANCE WITH SEC. R302.5.1
 FBC-RESIDENTIAL.
  
 18- FOUNDATION PLAN AND SECTION DETAILS DON'T SPECIFY
 SIZE OF FOOTINGS FOR ALL NEW STAIRS. PROVIDE COMPLETE
 DETAIL AND SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL.
  
 19- SHEET A-12:
 A)CLEARLY SPECIFY THE TRUSS CONNECTOR AT EACH END OF
 EACH TRUSS GIRDER. SOME TRUSS GIRDERS DON'T HAVE THIS
 INFORMATION. SEC. R301.2.1 FBC-RESIDENTIAL.
  
 B)CONNECTOR SCHEDULE SAYS "SEE DETAIL 1" FOR CONNECTOR
 "B". WHERE IS DETAIL 1?
 SEC. 107.2.1 CITY AMENDMENTS.
  
 20) NEED SEPARATE DEMOLITION PERMIT FOR DETACHED GARAGE
 AND EXISTING HOUSE PARTIAL DEMOLITION. SEC. 105.1 CITY
 AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-10-11 Cont ID  
Sent By fgiaquin Date 2022-10-11 Time 22:37 Rev Time 0.00
Received By fgiaquin Date 2022-10-06 Time 22:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-11-04 Cont ID  
Sent By fgiaquin Date 2021-11-04 Time 22:44 Rev Time 0.00
Received By fgiaquin Date 2021-11-04 Time 21:50 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2022-06-27 Cont ID  
Sent By rrossano Date 2022-06-27 Time   Rev Time 0.00
Received By rrossano Date 2022-06-27 Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2021-10-22 Cont ID  
Sent By lcrespo Date 2021-10-22 Time 16:11 Rev Time 0.00
Received By lcrespo Date 2021-10-22 Time 16:11 Sent To  
Notes
2021-10-22 16:13:05GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT
 BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND
 PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-05-01 Cont ID  
Sent By jgomez Date 2023-05-01 Time 11:16 Rev Time 0.00
Received By jgomez Date 2023-04-03 Time 10:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-03-31 Cont ID  
Sent By jgomez Date 2023-03-31 Time 14:13 Rev Time 0.00
Received By jgomez Date 2023-03-22 Time 16:57 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-11-17 Cont ID  
Sent By vbroglia Date 2022-11-17 Time 14:08 Rev Time 0.00
Received By vbroglia Date 2022-10-05 Time 09:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-07-19 Cont ID  
Sent By jgomez Date 2022-07-19 Time 13:34 Rev Time 0.00
Received By jgomez Date 2022-06-22 Time 07:45 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-09 Cont ID  
Sent By dbattles Date 2022-05-09 Time 09:15 Rev Time 0.00
Received By dbattles Date 2022-04-18 Time 16:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-03 Cont ID  
Sent By jgomez Date 2021-12-03 Time 14:09 Rev Time 0.00
Received By jgomez Date 2021-10-12 Time 07:33 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 5 Status P Date 2023-05-10 Cont ID  
Sent By lmarchan Date 2023-05-10 Time 14:41 Rev Time 0.00
Received By lmarchan Date 2023-04-04 Time 10:40 Sent To  
Notes
2023-05-10 14:41:41RECEIPT MU-2023-016166 - $2491.56 PAID
2023-05-01 13:10:245/1/23 FOLLOW UP EMAIL SENT. EMAILED IMPACT FOR
 REVIEW-AO
2023-04-04 10:40:474/4/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2023-03-31 Cont ID  
Sent By jgomez Date 2023-03-31 Time 14:12 Rev Time 0.00
Received By jgomez Date 2023-03-31 Time 14:12 Sent To  
Notes
2023-03-31 14:12:34IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2022-10-26 Cont ID  
Sent By jgomez Date 2022-10-26 Time 18:32 Rev Time 0.00
Received By jgomez Date 2022-10-26 Time 18:32 Sent To  
Notes
2022-10-26 18:33:07IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2022-05-09 Cont ID  
Sent By dbattles Date 2022-05-09 Time 09:07 Rev Time 0.00
Received By dbattles Date 2022-05-09 Time 09:07 Sent To  
Notes
2022-05-09 09:09:50PLEASE ADD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE TO
 SUPPORTING DOCUMENT FOLDER SO THIS CAN GET PBC IMPACT
 REVIEW.
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
2022-05-06 16:54:545/6/22 PER DB EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By jgomez Date 2021-12-03 Time 13:45 Rev Time 0.00
Received By jgomez Date 2021-12-03 Time 13:44 Sent To  
Notes
2021-12-03 13:45:22IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-10-17 Cont ID  
Sent By medwards Date 2022-10-17 Time 16:34 Rev Time 0.00
Received By medwards Date 2022-10-17 Time 16:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-05-03 Cont ID  
Sent By medwards Date 2022-05-03 Time 11:05 Rev Time 0.00
Received By medwards Date 2022-05-03 Time 11:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-10-14 Cont ID  
Sent By medwards Date 2021-10-14 Time 11:22 Rev Time 0.00
Received By medwards Date 2021-10-14 Time 11:22 Sent To  
Notes
2021-10-14 11:22:231ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21100379
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) PLEASE PROVIDE THE CONDENSATE PIPE AND TERMINATION
 LOCATION ON THE DRAWING. FBC RES M1411.3
  
 2) PLEASE SHOW THE BATH EXHAUST FANS AND THE
 TERMINATION LOCATION ON THE DRAWINGS AND INCLUDE THE
 SCREEN ON THE DETAIL DRAWING. FBC RES M1507.4
  
 3) PLEASE SHOW THE DRYER DUCT AND THE TERMINATION
 LOCATION ON THE DRAWING. FBC RES M1502
  
 4) IS THERE GOING TO BE A HOOD OVER THE RANGE? IF SO
 PLEASE SHOW IT ON THE DRAWING AND PROVIDE THE CFM OF
 EXHAUST. FBC RES M1503.3, M1503.4
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 6 Status P Date 2023-05-01 Cont ID  
Sent By jgomez Date 2023-05-01 Time 11:12 Rev Time 0.00
Received By jgomez Date 2023-05-01 Time 11:12 Sent To  
Notes
2023-05-01 11:12:35NFIP REVIEW APPROVED WITH PROVISO:
 1- REVISE "CONSTRUCTION DRAWINGS" ELEVATION
 CERTIFICATE:
 A) THE LATITUDE SPECIFIED ON ITEM A5 NEED TO PROVIDE AT
 LEAST 5 DECIMAL PLACES OR BETTER AS REQUIRED BY THEE
 FEMA ELEVATION CERTIFICATE PUBLISHED INSTRUCTIONS.
 B)GARAGE SQUARE FOOTAGE DOESN'T MATCH PLANS.
 C)REVISE TOTAL NET AREA OF FLOOD OPENINGS TO MATCH
 PLANS AND PRODUCT APPROVAL.
 D)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS
 INCORRECT.
 E)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) TO
 MATCH PLANS ENGINEER OF RECORD PLANS.
 F)LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST ADJACENT
 (FINISHED) GRADE ARE NO SHOWN ON SURVEY WITH PROPOSED
 STRUCTURE. UNABLE TO VERIFY.
 G)SURVEYOR NEEDS TO DATE ELEVATION CERTIFICATE WITH
 CURRENT DATE. ELEVATION CERTIFICATE WAS REVISED BUT
 SAME DATE WAS SHOWN.
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 5 Status F Date 2023-03-31 Cont ID  
Sent By jgomez Date 2023-03-31 Time 14:10 Rev Time 0.00
Received By jgomez Date 2023-03-31 Time 14:10 Sent To  
Notes
2023-03-31 14:11:151(B)- ELEVATION CERTIFICATE SUBMITTED:
 PREVIOUS COMMENT:
 (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS
 INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL
 AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 UNABLE TO VERIFY INFORMATION. FLOOD VENT PRODUCT
 APPROVAL WAS NOT SUBMITTED.
  
 PREVIOUS COMMENT:
 (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS
 INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND
 REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT REVISED.
  
 PREVIOUS COMMENT:
 (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS
 INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 UNABLE TO VERIFY INFORMATION. ENGINEER OF RECORD ERASED
 PROPOSED GARAGE ELEVATION.
  
 (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST
 ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED
 SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED.
 RESPONSE:
 UNABLE TO CONFIRM INFORMATION WITH SURVEY WITH PROPOSED
 STRUCTURE SUBMITTED. SURVEY DOESN'T SHOW THE EXTERIOR
 GRADE ELEVATIONS SHOWN ON ELEVATION CERTIFICATE.
 NOTE: COORDINATE WITH DRAINAGE PLAN. TO AVOID
 CONFITS/DELAYS.
 SEC.107.2.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 4 Status F Date 2022-10-26 Cont ID  
Sent By jgomez Date 2022-10-26 Time 18:26 Rev Time 0.00
Received By jgomez Date 2022-10-26 Time 18:23 Sent To  
Notes
2022-10-26 18:25:45NFIP REVIEW COMMENTS:
  
 PREVIOUS COMMENT:
 THIRD REVIEW:
 NEED TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE AND SURVEY FOR REVIEW.
  
 RESPONSE:
 A) SURVEY SUBMITTED IS FOR THE OLD HOUSE AND GARAGE.
 NEED SURVEY WITH PROPOSED CONSTRUCTION IN ORDER TO
 REVIEW ELEVATION CERTIFICATE SUBMITTED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 B)ELEVATION CERTIFICATE SUBMITTED:
 (1) BUILDING OWNER'S NAME IS INCORRECT. REVISE AS
 REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (2)PROPERTY LEGAL DESCRIPTION DOESN'T MATCH INFORMATION
 SHOWN ON THE SURVEY SUBMITTED. REVISE AS REQUIRED TO
 MATCH.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (3)BUILDING DIAGRAM NUMBER ON ITEM A7 IS INCORRECT.
 REVISE AS REQUIRED. SEE FEMA ELEVATION CERTIFICATE
 INSTRUCTIONS AND REVISE AS REQUIRED. IT LOOKS LIKE THIS
 IS DIAGRAM NUMBER 1B NOT 7.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS
 INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL
 AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS
 INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND
 REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (6)TOP OF BOTTOM FLOOR ELEVATION SPECIFIED ON ITEM
 C2(A) IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS
 INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (8)LOWEST ELEVATION OF AIR CONDITIONING UNIT SPECIFIED
 ON ITEM C2(E) DOESN'T COMPLY WITH CITY ORDINANCE
 4729-17.ELEVATION OF EQUIPMENT NEEDS TO BE 2 FEET ABOVE
 THE BASE FLOOD ELEVATION (9'-0" MIN.). COORDINATE WITH
 ENGINEER OF RECORD AND REVISE AS REQUIRED.
  
 (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST
 ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED
 SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED.
  
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT
 FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status F Date 2022-07-19 Cont ID  
Sent By jgomez Date 2022-07-19 Time 13:00 Rev Time 0.00
Received By jgomez Date 2022-07-19 Time 11:24 Sent To  
Notes
2022-07-19 11:27:03THIRD REVIEW:
 NEED TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE AND SURVEY FOR REVIEW. SEE COMMENTS BELOW.
  
  
  
 NFIP REVIEW COMMENTS:
 PERMIT #21100379
  
 1) SPECIFY THAT THE FLOOD ELEVATIONS ARE USING NAVD 88
 ON THE PLANS. FBC-R322
  
 2) SPECIFY THE ELEVATION OF THE ATTACHED GARAGE ON THE
 PLANS. FBC-R322
  
 3) SPECIFY WHETHER THE FLOOD OPENINGS IN THE GARAGE
 WALLS ARE ENGINEERED OR NON-ENGINEERED OPENINGS.
 PROVIDE CALCULATIONS ON THE PLANS TO SHOW THAT THE
 FLOOD OPENINGS IN THE GARAGE COMPLY WITH FBC-R 322.2.2.
 IF ENGINEERED FLOOD VENTS, SUCH AS "SMART VENTS", ARE
 USED SUBMIT THE EVALUATION REPORT FOR THEM.
  
 4) SUBMIT A SIGNED AND SEALED PRE-CONSTRUCTION
 ELEVATION CERTIFICATE BASED ON THE CONSTRUCTION
 DRAWINGS. CITY ORDINANCE 4729-17
  
 NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR
 ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS
 ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH
 FLOOR ELEVATIONS FOR REVIEW.
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT
 FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2022-05-02 Cont ID  
Sent By rmcdouga Date 2022-05-02 Time 17:23 Rev Time 0.00
Received By rmcdouga Date 2022-05-02 Time 17:23 Sent To  
Notes
2022-05-02 17:22:54NFIP REVIEW COMMENTS:
 PERMIT #21100379
  
 NOTE:
 SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 1) SPECIFY THAT THE FLOOD ELEVATIONS ARE USING NAVD 88
 ON THE PLANS. FBC-R322
  
 2) SPECIFY THE ELEVATION OF THE ATTACHED GARAGE ON THE
 PLANS. FBC-R322
  
 3) SPECIFY WHETHER THE FLOOD OPENINGS IN THE GARAGE
 WALLS ARE ENGINEERED OR NON-ENGINEERED OPENINGS.
 PROVIDE CALCULATIONS ON THE PLANS TO SHOW THAT THE
 FLOOD OPENINGS IN THE GARAGE COMPLY WITH FBC-R 322.2.2.
 IF ENGINEERED FLOOD VENTS, SUCH AS "SMART VENTS", ARE
 USED SUBMIT THE EVALUATION REPORT FOR THEM.
  
 4) SUBMIT A SIGNED AND SEALED PRE-CONSTRUCTION
 ELEVATION CERTIFICATE BASED ON THE CONSTRUCTION
 DRAWINGS. CITY ORDINANCE 4729-17
  
 NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR
 ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS
 ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH
 FLOOR ELEVATIONS FOR REVIEW.
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT
 FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By jgomez Date 2021-12-03 Time 14:07 Rev Time 0.00
Received By jgomez Date 2021-12-03 Time 14:07 Sent To  
Notes
2021-12-03 14:09:00NFIP REVIEW COMMENTS:
 PERMIT #21100379
  
 NOTE:
 SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 1- THE PROPOSED ADDITION IS GOING TO BE BUILT IN A AE
 FLOOD ZONE WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET
 BASED ON NAVD 88.
 THE PROPOSED ADDITION AND ALTERATION IS CONSIDERED A
 SUBSTANTIAL IMPROVEMENT. THE ADDITION AND THE EXISTING
 HOUSE SHALL HAVE THE LOWEST FLOOR FINISHED ELEVATION
 ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION PLUS TWO
 FEET.
 THEREFORE, THE MIN. REQUIRED FINISHED FLOOR ELEVATION
 IS 9 FEET.
 NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR
 ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS
 ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH
 FLOOR ELEVATIONS FOR REVIEW.
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT
 FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED:
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-10-07 Cont ID  
Sent By rwbrown Date 2022-10-07 Time 11:19 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-10-22 Cont ID  
Sent By lcrespo Date 2021-10-22 Time 16:10 Rev Time 0.00
Received By lcrespo Date 2021-10-22 Time 16:10 Sent To  
Notes
2021-10-22 16:11:0010/22/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status N Date 2023-03-31 Cont ID  
Sent By jgomez Date 2023-03-31 Time 14:08 Rev Time 0.00
Received By jgomez Date 2023-03-31 Time 14:07 Sent To  
Notes
2023-03-31 14:09:42 
 SUBMIT ALL ROOFING PRODUCT APPROVAL FOR REVIEW UNDER
 ROOFING SUB-PERMIT. JG
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2022-10-26 Cont ID  
Sent By jgomez Date 2022-10-26 Time 18:21 Rev Time 0.00
Received By jgomez Date 2022-10-26 Time 18:19 Sent To  
Notes
2022-10-26 18:20:41ROOFING REVIEW:
  
 PREVIOUS COMMENT:
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. CONTRACTOR TO ADVISE IF SUBMITTING NOW OR
 LATER AS A DEFERRED SUBMITTAL).
  
 A) PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON
 PLANS.
  
 B) RIDGE VENTS AS SPECIFIED ON PLANS. (NOA 11-0928.01
 IS EXPIRED).
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
  
 RESPONSE:
 ACCORDING TO ENGINEER OF RECORD RESPONSE LETTER ALL
 PRODUCT APPROVALS WILL BE APPROVED AND WILL BE
 SUBMITTED LATER AS DEFERRED SUBMITTALS.
 ONLY SOME PRODUCT APPROVALS WERE SUBMITTED AT THIS TIME
 AND THEY WERE NOT REVIEWED/APPROVED BY THE DESIGNER OF
 RECORD. ALSO, THE FLOOD VENT PRODUCT APPROVAL SUBMITTED
 IS INCOMPLETE. IT NEEDS THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND INSTALLATION INSTRUCTIONS. TO SAVE TIME,
 ALL PRODUCT APPROVALS SUBMITTED THIS TIME WILL BE
 BLOCKED AND WILL NOT BE REVIEWED AT THIS TIME.
 CONTRACTOR TO ADVISE IF SUBMITTING ALL THE PRODUCT
 APPROVALS (COMPLETE REPORTS) LATER AS A DEFERRED
 SUBMITTAL ONCE THEY ARE APPROVED BY THE DESIGNER OF
 RECORD OR IF SUBMITTING THEM ON NEXT RESUBMITTAL.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2022-07-19 Cont ID  
Sent By jgomez Date 2022-07-19 Time 13:05 Rev Time 0.00
Received By jgomez Date 2022-07-19 Time 13:05 Sent To  
Notes
2022-07-19 13:07:34ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A) PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON
 PLANS.
  
 B) RIDGE VENTS AS SPECIFIED ON PLANS. (NOA 11-0928.01
 IS EXPIRED).
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 NOTE;
 SHINGLES NOA 18-0207.04 SUBMITTED IS OK BUT IT NEEDS
 ENGINEER OF RECORD APPROVAL.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2022-05-09 Cont ID  
Sent By dbattles Date 2022-05-09 Time 09:05 Rev Time 0.00
Received By dbattles Date 2022-05-06 Time 09:50 Sent To  
Notes
2022-05-09 09:07:04NOA 18-0207.04 SHINGLES
 FL 11-0928.01 RIDGE VENT

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By jgomez Date 2021-12-03 Time 14:03 Rev Time 0.00
Received By jgomez Date 2021-12-03 Time 13:45 Sent To  
Notes
2021-12-03 14:07:06ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A) PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON
 PLANS.
  
 B) RIDGE VENTS AS SPECIFIED ON PLANS.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 NOTE;
 SHINGLES NOA 18-0207.04 SUBMITTED IS OK BUT IT NEEDS
 ENGINEER OF RECORD APPROVAL.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2023-03-31 Cont ID  
Sent By jgomez Date 2023-03-31 Time 14:16 Rev Time 0.00
Received By jgomez Date 2023-03-31 Time 14:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-10-07 Cont ID  
Sent By rwbrown Date 2022-10-07 Time 11:21 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-07-19 Cont ID  
Sent By jgomez Date 2022-07-19 Time 13:23 Rev Time 0.00
Received By jgomez Date 2022-07-19 Time 13:22 Sent To  
Notes
2022-07-19 13:25:04SIGNATURE REVIEW:
  
 1- THE FOLLOWING DRAWINGS HAVE A DIGITAL SIGNATURE THAT
 CAN NOT BE VERIFIED. A0, A1, A2, A8, A10, A11, M2, E1,
 E2, P1, P3.
 ALL DRAWINGS/DOCUMENTS NEED TO HAVE VERIFIABLE ORIGINAL
 DIGITAL SEAL/SIGNATURE AS REQUIRED BY CHAPTER 471 F.S.
 WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS.
 NOTE: NEED TO SUBMIT DRAWINGS ELECTRONICALLY WITH
 VERIFIABLE ORIGINAL DIGITAL SIGNATURE
  
 2- DRAWING C1 HAVE A COPY OF ENGINEER'S SEAL AND
 SIGNATURE. NEED ENGINEER'S ORIGINAL SEAL AND SIGNATURE
 AS REQUIRED BY CHAPTER 471 F.S. WHEN SUBMITTING
 DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS.
  
 3- SOIL TEST REPORT HAVE A COPY OF ENGINEER'S SEAL AND
 SIGNATURE. NEED ENGINEER'S ORIGINAL SEAL AND SIGNATURE
 AS REQUIRED BY CHAPTER 471 F.S. WHEN SUBMITTING
 DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS.
  
 EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED
 PLANS/DOCUMENTS WITH YOUR RESUBMITTAL IN PROJECTDOX, OR
 YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER
 ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION.
  
  
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-05-09 Cont ID  
Sent By dbattles Date 2022-05-09 Time 09:15 Rev Time 0.00
Received By dbattles Date 2022-05-06 Time 09:50 Sent To  
Notes
2022-05-03 11:07:24SHEET M-2 APPEARS TO BE A COPY OF THE DIGITAL
 SIGNATURE. PLEASE SUBMIT THE ORIGINAL DIGITALLY SIGNED
 DRAWING. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-10-12 Cont ID  
Sent By mpeterso Date 2021-10-12 Time 16:29 Rev Time 0.00
Received By mpeterso Date 2021-10-12 Time 16:32 Sent To  
Notes
2021-10-12 16:32:17ALL PRINTS OR DRAWINGS APPEAR TO BE DIGITAL COPIES
 WHICH ARE NOT ACCEPTABLE ACCORDING TO FLORIDA STATUES,
 PLEASE SEE BELOW HOW TO CORRECT THESE ISSUES
 FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED, SEALED, DATED ORIGINALS. A COPY OF A SIGNED
 PLAN IS NOT CONSIDERED AN ORIGINAL.IT APPEARS THE
 ENGINEER HAS A DIGITAL SIGNATURE PLEASE EMAIL THE
 ORIGINAL DIGITALLY SIGNED DOCUMENT
  
 EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF
 APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX,
 OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER
 ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION.
 SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO
 BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED
 DOCUMENTS ARE PREFERRED.
  
  
 PLEASE EMAIL [email protected] AND CC TO
 [email protected]
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop Z ZONING
Rev No 6 Status P Date 2023-04-13 Cont ID  
Sent By VBroglia Date 2023-04-13 Time 09:57 Rev Time 0.00
Received By vbroglia Date 2023-04-13 Time 09:57 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status F Date 2023-03-27 Cont ID  
Sent By VBroglia Date 2023-03-27 Time 16:05 Rev Time 0.00
Received By vbroglia Date 2023-03-27 Time 16:05 Sent To  
Notes
2023-03-27 16:06:09PREVIOUS COMMENT NOT ADDRESSSED

Review Stop Z ZONING
Rev No 4 Status F Date 2022-11-17 Cont ID  
Sent By vbroglia Date 2022-11-17 Time 14:07 Rev Time 0.00
Received By vbroglia Date 2022-11-17 Time 14:07 Sent To  
Notes
2022-11-17 14:08:1811/17/2022 FAILED
  
 PLEASE APPLY FOR A LANDSCAPE PERMIT

Review Stop Z ZONING
Rev No 3 Status F Date 2022-06-23 Cont ID  
Sent By vbroglia Date 2022-06-23 Time 13:30 Rev Time 0.00
Received By vbroglia Date 2022-06-23 Time 13:30 Sent To  
Notes
2022-06-23 13:32:116/23/22 FAILED
  
 PLEASE APPLY FOR A LANDSCAPE PERMIT TO ALLOW STAFF TO
 MOVE PERMIT FORWARD
  
 PLEASE SEE PREVIOUS COMMENTS FOR LANDSCAPE PLANNER
 CONTACT
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2022-04-26 Cont ID  
Sent By asangele Date 2022-04-26 Time 09:20 Rev Time 0.00
Received By asangele Date 2022-04-26 Time 09:20 Sent To  
Notes
2022-04-26 09:31:044/26/2022
 FAIL
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING LOCATED IN
 SINGLE FAMILY LOW DENSITY ZONING
 REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER IS
 LESS;
  
 THE VALUE OF THE CONSTRUCTION ($420,000) EXCEEDS 50% OF
 THE STRUCTURE'S VALUE ($157,682) ACCORDING TO THE
 P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT
 TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO
 ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN
 DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE
 PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO
 ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS
 PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION
 PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE
 SITE INTO CONFORMITY.
  
 PLEASE GET INTO CONTACT WITH RAY CARANCI THE CITY'S
 LANDSCAPE PLANNER [email protected]
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By rthermid Date 2021-10-27 Time   Rev Time  
Received By   Date 2021-10-27 Time   Sent To I
Notes
2021-10-27 09:52:43INTERIOR WORK/REMODEL
 (NO CHANGES IN DENSITY) - PASS ZONING