| Plan Review Stops For Permit 21100379 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-04-04 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-04-03 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2023-04-04 09:44:01 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- REVISE "CONSTRUCTION DRAWINGS" ELEVATION | | | CERTIFICATE: A) THE LATITUDE SPECIFIED ON ITEM A5 NEED | | | TO PROVIDE AT LEAST 5 DECIMAL PLACES OR BETTER AS | | | REQUIRED BY THEE FEMA ELEVATION CERTIFICATE PUBLISHED | | | INSTRUCTIONS. B)GARAGE SQUARE FOOTAGE DOESN'T MATCH | | | PLANS. C)REVISE TOTAL NET AREA OF FLOOD OPENINGS TO | | | MATCH PLANS AND PRODUCT APPROVAL. D)THE BASE FLOOD | | | ELEVATION SPECIFIED ON ITEM B9 IS INCORRECT. E)ATTACHED | | | GARAGE ELEVATION SPECIFIED ON ITEM C2(D) TO MATCH PLANS | | | ENGINEER OF RECORD PLANS. F)LOWEST ADJACENT (FINISHED) | | | GRADE AND HIGHEST ADJACENT (FINISHED) GRADE ARE NO | | | SHOWN ON SURVEY WITH PROPOSED STRUCTURE. UNABLE TO | | | VERIFY. G)SURVEYOR NEEDS TO DATE ELEVATION CERTIFICATE | | | WITH CURRENT DATE. ELEVATION CERTIFICATE WAS REVISED | | | BUT SAME DATE WAS SHOWN. | | | | | | 2- PRODUCT APPROVAL DEFERRAL: A)INSWING ENTRY DOORS. | | | B)INSWING SIDE DOOR #4. C)SLIDING GLASS DOORS. | | | D)OVERHEAD GARAGE DOOR. E)CASEMENT WINDOWS. F)SINGLE | | | HUNG WINDOWS. G)FIXED WINDOWS. H)HORIZONTAL ROLLER | | | WINDOWS. I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY | | | MULLION SIZE. J)HURRICANE SHUTTERS IF DOORS AND WINDOWS | | | DON'T HAVE IMPACT GLAZING. AND, PROVIDE COMPLETE | | | INSTALLATION SCHEDULE. K)SHINGLES. L)PEEL & STICK | | | SHINGLES UNDERLAYMENT SPECIFIED ON PLANS. | | | M)RIDGE VENTS AS SPECIFIED ON PLANS. N)FLOOD VENTS AS | | | SPECIFIED ON PLANS. | | | | | | 3- ENGINEER OF RECORD TO SPECIFY PROPOSED FINISH FLOOR | | | ELEVATION OF GARAGE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-31 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2023-03-31 14:07:16 | RESIDENTIAL(R3) ADDITION, ALTERATION 5TH BUILDING | | | REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21100379 | | | 102 GREGORY RD | | | | | | PROVISO NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES APPLY (EXCEPT FOR | | | PRODUCT APPROVALS DEFERRED SUBMITTAL). | | | | | | ***IMPORTANT | | | ****CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED | | | AT THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION | | | BEFORE PERMIT ISSUANCE. | | | | | | | | | 1(B)- ELEVATION CERTIFICATE SUBMITTED: | | | PREVIOUS COMMENT: | | | (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS | | | INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL | | | AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | UNABLE TO VERIFY INFORMATION. FLOOD VENT PRODUCT | | | APPROVAL WAS NOT SUBMITTED. | | | | | | PREVIOUS COMMENT: | | | (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS | | | INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND | | | REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT REVISED. | | | | | | PREVIOUS COMMENT: | | | (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS | | | INCORRECT. SEE PLANS AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | UNABLE TO VERIFY INFORMATION. ENGINEER OF RECORD ERASED | | | PROPOSED GARAGE ELEVATION. | | | | | | (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST | | | ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED | | | SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED. | | | RESPONSE: | | | UNABLE TO CONFIRM INFORMATION WITH SURVEY WITH PROPOSED | | | STRUCTURE SUBMITTED. SURVEY DOESN'T SHOW THE EXTERIOR | | | GRADE ELEVATIONS SHOWN ON ELEVATION CERTIFICATE. | | | NOTE: COORDINATE WITH DRAINAGE PLAN. TO AVOID | | | CONFITS/DELAYS. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | 15- PRODUCT APPROVALS WILL BE A DEFFERRED SUBMITTAL | | | AFTER THE PERMIT IS ISSUED. | | | A)INSWING ENTRY DOORS A SHOWN ON PLANS. | | | B)INSWING SIDE DOOR #4 AS SHOWN ON PLANS. | | | C)SLIDING GLASS DOORS (NOTE: NEED FOR LARGE MISSILE | | | IMPACT) | | | D)OVERHEAD GARAGE DOOR. | | | E)CASEMENT WINDOWS. | | | F)SINGLE HUNG WINDOWS. | | | G)FIXED WINDOWS. | | | H)HORIZONTAL ROLLER | | | WINDOWS. | | | I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY | | | MULLION SIZE TO AVOID DELAYS/CONFLICTS). | | | J)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT | | | GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | K)SHINGLES. | | | L)PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON | | | PLANS. | | | M)RIDGE VENTS AS SPECIFIED ON PLANS. | | | N)FLOOD VENTS AS SPECIFIED ON PLANS. | | | | | | NEW COMMENTS BASED ON REVISED PLANS: | | | 16- ENGINEER OF RECORD TO SPECIFY PROPOSED FINISH FLOOR | | | ELEVATION OF GARAGE. NOTE: INFORMATION WAS SUBMITTED | | | BEFORE, BUT IT GOT ERASED ON RESUBMITTED PLANS. NEED | | | INFORMATION TO CHECK/VERIFY CONSTRUCTION DRAWINGS | | | ELEVATION CERTIFICATE SUBMITTED. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | ***************************** | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-26 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-26 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2022-10-26 18:19:50 | RESIDENTIAL (R3) ADDITION, ALTERATION 4TH BUILDING | | | REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21100379 | | | 102 GREGORY RD | | | | | | PREVIOUS COMMENT: | | | 1- REPEAT COMMENT. THREE TIMES. NOT ADDRESSED AT ALL. | | | NEED TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION | | | CERTIFICATE AND SURVEY FOR REVIEW. | | | | | | RESPONSE: | | | A) SURVEY SUBMITTED IS FOR THE OLD HOUSE AND GARAGE. | | | NEED SURVEY WITH PROPOSED CONSTRUCTION IN ORDER TO | | | REVIEW ELEVATION CERTIFICATE SUBMITTED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | B)ELEVATION CERTIFICATE SUBMITTED: | | | (1) BUILDING OWNER'S NAME IS INCORRECT. REVISE AS | | | REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (2)PROPERTY LEGAL DESCRIPTION DOESN'T MATCH INFORMATION | | | SHOWN ON THE SURVEY SUBMITTED. REVISE AS REQUIRED TO | | | MATCH. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (3)BUILDING DIAGRAM NUMBER ON ITEM A7 IS INCORRECT. | | | REVISE AS REQUIRED. SEE FEMA ELEVATION CERTIFICATE | | | INSTRUCTIONS AND REVISE AS REQUIRED. IT LOOKS LIKE THIS | | | IS DIAGRAM NUMBER 1B NOT 7. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS | | | INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL | | | AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS | | | INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND | | | REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (6)TOP OF BOTTOM FLOOR ELEVATION SPECIFIED ON ITEM | | | C2(A) IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS | | | INCORRECT. SEE PLANS AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (8)LOWEST ELEVATION OF AIR CONDITIONING UNIT SPECIFIED | | | ON ITEM C2(E) DOESN'T COMPLY WITH CITY ORDINANCE | | | 4729-17.ELEVATION OF EQUIPMENT NEEDS TO BE 2 FEET ABOVE | | | THE BASE FLOOD ELEVATION (9'-0" MIN.). COORDINATE WITH | | | ENGINEER OF RECORD AND REVISE AS REQUIRED. | | | | | | (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST | | | ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED | | | SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED. | | | | | | | | | PREVIOUS COMMENT: | | | 2- DRAINAGE PLAN SUBMITTED IS FOR THE EXISTING | | | STRUCTURES. NEED TO PROVIDE DRAINAGE PLAN WITH PROPOSED | | | STRUCTURES. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | PREVIOUS COMMENT: | | | 15- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. CONTRACTOR TO ADVISE IF SUBMITTING NOW OR | | | LATER AS A DEFERRED SUBMITTAL). | | | | | | A)INSWING ENTRY DOORS A SHOWN ON PLANS. | | | B)INSWING SIDE DOOR #4 AS SHOWN ON PLANS. | | | C)SLIDING GLASS DOORS (NOTE: NEED FOR LARGE MISSILE | | | IMPACT) | | | D)OVERHEAD GARAGE DOOR. | | | E)CASEMENT WINDOWS. | | | F)SINGLE HUNG WINDOWS. | | | G)FIXED WINDOWS. | | | H)HORIZONTAL ROLLER | | | WINDOWS. | | | I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY | | | MULLION SIZE TO AVOID DELAYS/CONFLICTS). | | | J)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT | | | GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | K)SHINGLES. | | | L)PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON | | | PLANS. | | | M)RIDGE VENTS AS SPECIFIED ON PLANS. | | | N)FLOOD VENTS AS SPECIFIED ON PLANS. | | | | | | RESPONSE: | | | ACCORDING TO ENGINEER OF RECORD RESPONSE LETTER ALL | | | PRODUCT APPROVALS WILL BE APPROVED AND WILL BE | | | SUBMITTED LATER AS DEFERRED SUBMITTALS. | | | ONLY SOME PRODUCT APPROVALS WERE SUBMITTED AT THIS TIME | | | AND THEY WERE NOT REVIEWED/APPROVED BY THE DESIGNER OF | | | RECORD. ALSO, THE FLOOD VENT PRODUCT APPROVAL SUBMITTED | | | IS INCOMPLETE. IT NEEDS THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE AND INSTALLATION INSTRUCTIONS. TO SAVE TIME, | | | ALL PRODUCT APPROVALS SUBMITTED THIS TIME WILL BE | | | BLOCKED AND WILL NOT BE REVIEWED AT THIS TIME. | | | CONTRACTOR TO ADVISE IF SUBMITTING ALL THE PRODUCT | | | APPROVALS (COMPLETE REPORTS) LATER AS A DEFERRED | | | SUBMITTAL ONCE THEY ARE APPROVED BY THE DESIGNER OF | | | RECORD OR IF SUBMITTING THEM ON NEXT RESUBMITTAL. | | | | | | NEW COMMENT BASED ON REVISED PLANS: | | | 16- SHEET A-2: ENGINEER REVISED THE BASE FLOOD | | | ELEVATION UNDER FLOOD ZONE. THE REVISED INFORMATION IS | | | INCORRECT. ACCORDING TO FLOOD INSURANCE RATE MAP (FIRM) | | | DATED 10-05-2017 THE BASE FLOOD ELEVATION IS 7'-0" NOT | | | 6'-0". REVISE AS REQUIRED. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-19 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-18 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2022-07-19 13:00:32 | RESIDENTIAL (R3) ADDITION, ALTERATION THIRD BUILDING | | | REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21100379 | | | | | | PREVIOUS COMMENT: | | | 1- NFIP COMMENTS WILL RESOLVE THIS COMMENT. | | | NOTE: DURING THE PERMITTING OF THIS STRUCTURE THREE | | | DIFFERENT | | | FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED: | | | A) CONSTRUCTION DRAWINGS. | | | B) BUILDING UNDER CONSTRUCTION. | | | C) FINISHED CONSTRUCTION. | | | | | | RESPONSE: | | | REPEAT COMMENT. THREE TIMES. NOT ADDRESSED AT ALL. NEED | | | TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION CERTIFICATE | | | AND SURVEY FOR REVIEW. | | | | | | PREVIOUS COMMENT: | | | 2- LOT DRAINAGE | | | 2ND REVIEW NO DRAINAGE PLAN WAS ADDED. PLEASE ADD | | | DRAWING OR NOTES TO SATISFY DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY | | | AMENDMENTS. SEC. 110.9 CITY AMENDMENTS. NOTE: | | | DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED GRADE | | | ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | RESPONSE: | | | DRAINAGE PLAN SUBMITTED IS FOR THE EXISTING STRUCTURES. | | | NEED TO PROVIDE DRAINAGE PLAN WITH PROPOSED STRUCTURES. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | PREVIOUS COMMENT: | | | 15- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 | | | FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | A)INSWING ENTRY DOORS A SHOWN ON PLANS. | | | B)INSWING SIDE DOOR #4 AS SHOWN ON PLANS. | | | C)SLIDING GLASS DOORS (NOTE: NEED FOR LARGE MISSILE | | | IMPACT) | | | D)OVERHEAD GARAGE DOOR. | | | E)CASEMENT WINDOWS. | | | F)SINGLE HUNG WINDOWS. | | | G)FIXED WINDOWS. | | | H)HORIZONTAL ROLLER | | | WINDOWS. | | | I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY | | | MULLION SIZE TO AVOID DELAYS/CONFLICTS). | | | J)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT | | | GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | K)SHINGLES. | | | L)PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON | | | PLANS. | | | M)RIDGE VENTS AS SPECIFIED ON PLANS. | | | N)FLOOD VENTS AS SPECIFIED ON PLANS. | | | | | | RESPONSE: | | | ACCORDING TO ENGINEER OF RECORD RESPONSE LETTER ALL | | | PRODUCT APPROVALS WILL BE APPROVED AND WILL BE | | | SUBMITTED LATER AS DEFERRED SUBMITTALS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-05-09 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-05-06 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2022-05-09 09:04:15 | | | | 2ND REVIEW COMPLETED 5/9/22 | | | DYLAN BATTLES | | | [email protected] | | | 561-805-6718 | | | BUILDING PLANS EXAMINER - LICENSE PX4191 | | | | | | RESIDENTIAL (R3) ADDITION, ALTERATION BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21100379 | | | | | | NOTE: | | | SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | 1- NFIP COMMENTS WILL RESOLVE THIS COMMENT. | | | | | | NOTE: DURING THE PERMITTING OF THIS STRUCTURE THREE | | | DIFFERENT | | | FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED: | | | A) CONSTRUCTION DRAWINGS. | | | B) BUILDING UNDER CONSTRUCTION. | | | C) FINISHED CONSTRUCTION. | | | | | | 2- LOT DRAINAGE | | | 2ND REVIEW NO DRAINAGE PLAN WAS ADDED. PLEASE ADD | | | DRAWING OR NOTES TO SATISFY DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY | | | AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | | | | | | | | | | | | | 13- ENGINEER TO CLARIFY REQUIRED SOIL BEARING | | | CAPACITY. | | | SOME NOTES SPECIFY 2,000PSF, WHILE SOME OTHER NOTES ON | | | SAME PLANS SUBMITTED SPECIFY 2,500PSF. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | | | | 15- PRODUCT APPROVALS | | | 2ND REVIEW VERIFY WHAT PRODUCT APPROVALS ARE TO BE | | | DEFERRED. WE STILL NEED GARAGE DOOR, CASEMENET WINDOW, | | | FIXED WINDOW, SWING DOOR AND FRENCH DOOR. | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 | | | FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | A)INSWING ENTRY DOORS A SHOWN ON PLANS. B)INSWING SIDE | | | DOOR #4 AS SHOWN ON PLANS. C)SLIDING GLASS DOORS. | | | D)OVERHEAD GARAGE DOOR. E)CASEMENT WINDOWS. F)SINGLE | | | HUNG WINDOWS. G)FIXED WINDOWS. H)HORIZONTAL ROLLER | | | WINDOWS. I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY | | | MULLION SIZE TO AVOID DELAYS/CONFLICTS). J)HURRICANE | | | SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT | | | GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | SEE CITY SAMPLE. K)SHINGLES. L)PEEL & STICK SHINGLES | | | UNDERLAYMENT SPECIFIED ON PLANS. M)RIDGE VENTS AS | | | SPECIFIED ON PLANS. N)FLOOD VENTS AS SPECIFIED ON | | | PLANS. | | | | | | 16- ENGINEER OF RECORD TO REVIEW AND APPROVE IN | | | WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | | | | | | | 20) NEED SEPARATE DEMOLITION PERMIT FOR DETACHED | | | GARAGE | | | AND EXISTING HOUSE PARTIAL DEMOLITION. SEC. 105.1 CITY | | | AMENDMENTS. | | | 2ND REVIEW. NO APPLICATION IN SYSTEM FOR DEMO PERMIT | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-03 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-03 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2021-12-03 13:41:57 | RESIDENTIAL (R3) ADDITION, ALTERATION BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21100379 | | | | | | NOTE: | | | SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | 1- THE PROPOSED ADDITION IS GOING TO BE BUILT IN A AE | | | FLOOD ZONE WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET | | | BASED ON NAVD 88. | | | THE PROPOSED ADDITION AND ALTERATION IS CONSIDERED A | | | SUBSTANTIAL IMPROVEMENT. THE ADDITION AND THE EXISTING | | | HOUSE SHALL HAVE THE LOWEST FLOOR FINISHED ELEVATION | | | ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION PLUS TWO | | | FEET. | | | THEREFORE, THE MIN. REQUIRED FINISHED FLOOR ELEVATION | | | IS 9 FEET. | | | NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR | | | ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS | | | ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH | | | FLOOR ELEVATIONS FOR REVIEW. | | | CITY ORDINANCE 4729-17. | | | SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE. | | | SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT | | | FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED: | | | A) CONSTRUCTION DRAWINGS. | | | B) BUILDING UNDER CONSTRUCTION. | | | C) FINISHED CONSTRUCTION. | | | | | | 2- LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY | | | AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | 3-PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. 1101.1 | | | FBC-EXISTING BUILDING AND SEC. R401.4 FBC-RESIDENTIAL. | | | | | | 4-ACCORDING TO SEC. R301.2.1.4.3 FBC-RESIDENTIAL THIS | | | BUILDING IS LOCATED IN EXPOSURE "D" NOT "C". REVISE | | | BUILDING EXPOSURE AND ALL ROOF AND WALLS DESIGN WIND | | | PRESSURES INFORMATION. REVISE BUILDING EXPOSURE ON | | | SHEET A-2, A-3 AND ANY OTHER DRAWING SPECIFYING | | | EXPOSURE "C". | | | NOTE: PRODUCT APPROVALS WILL BE REVIEWED WHEN DESIGN | | | PRESSURES ARE REVISED. | | | | | | 5- DESIGNER OF RECORD TO SPECIFY ALL LIVE AND DEAD | | | LOADS. CLEARLY SPECIFY ROOF LIVE AND DEAD LOADS (TOP | | | AND BOTTOM CHORDS), INCLUDING THE ATTIC LIVE LOAD AS | | | REQUIRED BY TABLE R301.5 FBC-RESIDENTIAL. SEE FOOTNOTES | | | "B" AND "G". | | | NOTE: ENGINEER TO CLARIFY WHY STATING N.A. FOR FLOOR | | | LIVE LOAD ON THE DESIGN LOADS ON SHEET A-2. | | | | | | 6-BEDROOM #2 EGRESS WINDOW DOESN'T COMPLY WITH SEC. | | | R310.2.1 FBC-RESIDENTIAL. REVISE AS REQUIRED OR PROVIDE | | | MANUFACTURER'S CUT SHEETS SHOWING THAT 26"X63" CASEMENT | | | WINDOW MEETS THE EGRESS REQUIREMENTS. | | | | | | 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION. SEC. R807.1 | | | FBC-RESIDENTIAL. | | | | | | 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | | CONSTRUCTION OF HANDRAILS AND GUARDRAILS SHOWING | | | COMPLIANCE WITH TABLE R301.5, SEC. R311.7.8 AND SEC. | | | R312.1 FBC-RESIDENTIAL. | | | NOTE: IF THIS IS A DEFERRED SUBMITTAL, THEN SPECIFY THE | | | DESIGN GUIDELINES REQUIRED BY TABLE R301.5, SEC. | | | R311.7.8 AND SEC. R312.1 AND CLEARLY SPECIFY ON PLANS | | | THAT SHOP DRAWINGS NEED TO BE SUBMITTED FOR REVIEW | | | PRIOR TO CONSTRUCTION. ALL SHOP DRAWINGS TO BE REVIEWED | | | BY THE DESIGN PROFESSIONAL OF RECORD PRIOR TO SUBMITTAL | | | TO THIS OFFICE. | | | | | | 9- REVISE PLYWOOD ROOF SHEATHING NAILING SPACING. ROOF | | | SHEATHING NEEDS TO BE NAILED WITH RING SHANK NAILS AT 4 | | | INCHES O.C. IN THE FIELD AND EDGES AS REQUIRED BY SEC. | | | R803.2.3.1 AND TABLE R803.2.3.1 FBC-RESIDENTIAL. | | | NOTE: REVISE ALL DRAWINGS NOTES REFERENCING THE ROOF | | | SHEATHING THICKNESS AND NAIL SIZE AND SPACING TO AVOID | | | CONFLICTS/DELAYS. | | | | | | 10- REVISE WIND ZONE ROOF PLAN ON SHEET A-11 TO COMPLY | | | WITH CURRENT CODE ROOF ZONES FIGURE R301.2(7) AND | | | REVISE WIND PRESSURES ACCORDINGLY. | | | NOTE: BUILDING IS LOCATE IN EXPOSURE "D" NOT "C". | | | | | | 11-PROVIDE SWING DOOR STRUCTURAL BUCK DETAIL SHOWING | | | COMPLIANCE WITH SEC. R609.7.2.1 FBC-RESIDENTIAL. | | | SPECIFY STRUCTURAL BUCK SIZE AND FASTENING. | | | NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO | | | THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | | FBC-RESIDENTIAL. | | | | | | 12- ATTIC VENTILATION: | | | ATTIC VENT CALCULATIONS ON SHEET A-4 SHOW 20 LINEAR | | | FEET OF RIDGE VENTILATION. EXTERIOR ELEVATIONS ONLY | | | SHOW 10'-0" OF RIDGE VENTILATION. REVISE AS REQUIRED. | | | SEC. R806 FBC-RESIDENTIAL. | | | | | | 13- ENGINEER TO CLARIFY REQUIRED SOIL BEARING CAPACITY. | | | SOME NOTES SPECIFY 2,000PSF, WHILE SOME OTHER NOTES ON | | | SAME PLANS SUBMITTED SPECIFY 2,500PSF. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 14- ENERGY CALCULATIONS SUBMITTED: | | | A)THE ENERGY FORM R405-2020 IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER, ARCHITECT OR OWNER?S LEGALLY | | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | | PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION. | | | | | | B) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | | FORM, INCLUDING OWNER'S NAME, BUILDER'S NAME, CORRECT | | | PERMIT OFFICE (CITY OF WEST PALM BEACH NOT PALM BEACH | | | COUNTY, CORRECT JURISDICTION NUMBER (JURISDICTION | | | NUMBER IS 604700) SEC. R101.5.1.1.2 FBC- ENERGY | | | CONSERVATION. | | | | | | C)PROVIDE THE NAME (NOT SIGNATURE) OF PERSON PERFORMING | | | THE ANALYSIS AND GENERATING THE REPORT AS REQUIRED BY | | | SEC. R405.4.2.1 FBC- ENERGY CONSERVATION. | | | | | | D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY | | | CONSERVATION. | | | | | | E)CLARIFY WHY THERE ARE NO OCCUPANTS SPECIFIED IN THE | | | "SPACES" AREA ON PAGE 2 OF 7. REVISE AS REQUIRED. SEC. | | | R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | | | 15- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | A)INSWING ENTRY DOORS A SHOWN ON PLANS. B)INSWING SIDE | | | DOOR #4 AS SHOWN ON PLANS. C)SLIDING GLASS DOORS. | | | D)OVERHEAD GARAGE DOOR. E)CASEMENT WINDOWS. F)SINGLE | | | HUNG WINDOWS. G)FIXED WINDOWS. H)HORIZONTAL ROLLER | | | WINDOWS. I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY | | | MULLION SIZE TO AVOID DELAYS/CONFLICTS). J)HURRICANE | | | SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT | | | GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | SEE CITY SAMPLE. K)SHINGLES. L)PEEL & STICK SHINGLES | | | UNDERLAYMENT SPECIFIED ON PLANS. M)RIDGE VENTS AS | | | SPECIFIED ON PLANS. N)FLOOD VENTS AS SPECIFIED ON | | | PLANS. | | | | | | 16- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 17- PROVIDE FIRE RATING SPECIFICATIONS OR SPECIFY TYPE | | | OF SOLID DOOR FOR GARAGE DOOR LEADING TO THE INTERIOR | | | OF THE HOUSE SHOWING COMPLIANCE WITH SEC. R302.5.1 | | | FBC-RESIDENTIAL. | | | | | | 18- FOUNDATION PLAN AND SECTION DETAILS DON'T SPECIFY | | | SIZE OF FOOTINGS FOR ALL NEW STAIRS. PROVIDE COMPLETE | | | DETAIL AND SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 19- SHEET A-12: | | | A)CLEARLY SPECIFY THE TRUSS CONNECTOR AT EACH END OF | | | EACH TRUSS GIRDER. SOME TRUSS GIRDERS DON'T HAVE THIS | | | INFORMATION. SEC. R301.2.1 FBC-RESIDENTIAL. | | | | | | B)CONNECTOR SCHEDULE SAYS "SEE DETAIL 1" FOR CONNECTOR | | | "B". WHERE IS DETAIL 1? | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 20) NEED SEPARATE DEMOLITION PERMIT FOR DETACHED GARAGE | | | AND EXISTING HOUSE PARTIAL DEMOLITION. SEC. 105.1 CITY | | | AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-10-11 |
Time |
22:37 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-10-06 |
Time |
22:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-11-04 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-11-04 |
Time |
22:44 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-11-04 |
Time |
21:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-06-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-06-27 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-22 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-22 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2021-10-22 16:13:05 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT | | | BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND | | | PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-01 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-04-03 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-22 |
Time |
16:57 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-11-17 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-10-05 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-19 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-22 |
Time |
07:45 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-05-09 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-04-18 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-03 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-12 |
Time |
07:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-05-10 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-04-04 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2023-05-10 14:41:41 | RECEIPT MU-2023-016166 - $2491.56 PAID | | 2023-05-01 13:10:24 | 5/1/23 FOLLOW UP EMAIL SENT. EMAILED IMPACT FOR | | | REVIEW-AO | | 2023-04-04 10:40:47 | 4/4/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-31 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2023-03-31 14:12:34 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-26 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-26 |
Time |
18:32 |
Sent To |
|
|
| Notes |
| 2022-10-26 18:33:07 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-05-09 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-05-09 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2022-05-09 09:09:50 | PLEASE ADD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE TO | | | SUPPORTING DOCUMENT FOLDER SO THIS CAN GET PBC IMPACT | | | REVIEW. | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | 2022-05-06 16:54:54 | 5/6/22 PER DB EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-03 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-03 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2021-12-03 13:45:22 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-17 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-17 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-03 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-03 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-14 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-14 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2021-10-14 11:22:23 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21100379 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | | | | 1) PLEASE PROVIDE THE CONDENSATE PIPE AND TERMINATION | | | LOCATION ON THE DRAWING. FBC RES M1411.3 | | | | | | 2) PLEASE SHOW THE BATH EXHAUST FANS AND THE | | | TERMINATION LOCATION ON THE DRAWINGS AND INCLUDE THE | | | SCREEN ON THE DETAIL DRAWING. FBC RES M1507.4 | | | | | | 3) PLEASE SHOW THE DRYER DUCT AND THE TERMINATION | | | LOCATION ON THE DRAWING. FBC RES M1502 | | | | | | 4) IS THERE GOING TO BE A HOOD OVER THE RANGE? IF SO | | | PLEASE SHOW IT ON THE DRAWING AND PROVIDE THE CFM OF | | | EXHAUST. FBC RES M1503.3, M1503.4 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
6 |
Status |
P |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-01 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-01 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2023-05-01 11:12:35 | NFIP REVIEW APPROVED WITH PROVISO: | | | 1- REVISE "CONSTRUCTION DRAWINGS" ELEVATION | | | CERTIFICATE: | | | A) THE LATITUDE SPECIFIED ON ITEM A5 NEED TO PROVIDE AT | | | LEAST 5 DECIMAL PLACES OR BETTER AS REQUIRED BY THEE | | | FEMA ELEVATION CERTIFICATE PUBLISHED INSTRUCTIONS. | | | B)GARAGE SQUARE FOOTAGE DOESN'T MATCH PLANS. | | | C)REVISE TOTAL NET AREA OF FLOOD OPENINGS TO MATCH | | | PLANS AND PRODUCT APPROVAL. | | | D)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS | | | INCORRECT. | | | E)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) TO | | | MATCH PLANS ENGINEER OF RECORD PLANS. | | | F)LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST ADJACENT | | | (FINISHED) GRADE ARE NO SHOWN ON SURVEY WITH PROPOSED | | | STRUCTURE. UNABLE TO VERIFY. | | | G)SURVEYOR NEEDS TO DATE ELEVATION CERTIFICATE WITH | | | CURRENT DATE. ELEVATION CERTIFICATE WAS REVISED BUT | | | SAME DATE WAS SHOWN. | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
F |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-31 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2023-03-31 14:11:15 | 1(B)- ELEVATION CERTIFICATE SUBMITTED: | | | PREVIOUS COMMENT: | | | (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS | | | INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL | | | AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | UNABLE TO VERIFY INFORMATION. FLOOD VENT PRODUCT | | | APPROVAL WAS NOT SUBMITTED. | | | | | | PREVIOUS COMMENT: | | | (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS | | | INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND | | | REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT REVISED. | | | | | | PREVIOUS COMMENT: | | | (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS | | | INCORRECT. SEE PLANS AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | UNABLE TO VERIFY INFORMATION. ENGINEER OF RECORD ERASED | | | PROPOSED GARAGE ELEVATION. | | | | | | (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST | | | ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED | | | SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED. | | | RESPONSE: | | | UNABLE TO CONFIRM INFORMATION WITH SURVEY WITH PROPOSED | | | STRUCTURE SUBMITTED. SURVEY DOESN'T SHOW THE EXTERIOR | | | GRADE ELEVATIONS SHOWN ON ELEVATION CERTIFICATE. | | | NOTE: COORDINATE WITH DRAINAGE PLAN. TO AVOID | | | CONFITS/DELAYS. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
F |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-26 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-26 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2022-10-26 18:25:45 | NFIP REVIEW COMMENTS: | | | | | | PREVIOUS COMMENT: | | | THIRD REVIEW: | | | NEED TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION | | | CERTIFICATE AND SURVEY FOR REVIEW. | | | | | | RESPONSE: | | | A) SURVEY SUBMITTED IS FOR THE OLD HOUSE AND GARAGE. | | | NEED SURVEY WITH PROPOSED CONSTRUCTION IN ORDER TO | | | REVIEW ELEVATION CERTIFICATE SUBMITTED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | B)ELEVATION CERTIFICATE SUBMITTED: | | | (1) BUILDING OWNER'S NAME IS INCORRECT. REVISE AS | | | REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (2)PROPERTY LEGAL DESCRIPTION DOESN'T MATCH INFORMATION | | | SHOWN ON THE SURVEY SUBMITTED. REVISE AS REQUIRED TO | | | MATCH. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (3)BUILDING DIAGRAM NUMBER ON ITEM A7 IS INCORRECT. | | | REVISE AS REQUIRED. SEE FEMA ELEVATION CERTIFICATE | | | INSTRUCTIONS AND REVISE AS REQUIRED. IT LOOKS LIKE THIS | | | IS DIAGRAM NUMBER 1B NOT 7. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS | | | INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL | | | AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS | | | INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND | | | REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (6)TOP OF BOTTOM FLOOR ELEVATION SPECIFIED ON ITEM | | | C2(A) IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS | | | INCORRECT. SEE PLANS AND REVISE AS REQUIRED. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | (8)LOWEST ELEVATION OF AIR CONDITIONING UNIT SPECIFIED | | | ON ITEM C2(E) DOESN'T COMPLY WITH CITY ORDINANCE | | | 4729-17.ELEVATION OF EQUIPMENT NEEDS TO BE 2 FEET ABOVE | | | THE BASE FLOOD ELEVATION (9'-0" MIN.). COORDINATE WITH | | | ENGINEER OF RECORD AND REVISE AS REQUIRED. | | | | | | (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST | | | ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED | | | SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED. | | | | | | CITY ORDINANCE 4729-17. | | | SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE. | | | SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT | | | FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED: | | | A) CONSTRUCTION DRAWINGS. | | | B) BUILDING UNDER CONSTRUCTION. | | | C) FINISHED CONSTRUCTION. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-19 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-19 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2022-07-19 11:27:03 | THIRD REVIEW: | | | NEED TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION | | | CERTIFICATE AND SURVEY FOR REVIEW. SEE COMMENTS BELOW. | | | | | | | | | | | | NFIP REVIEW COMMENTS: | | | PERMIT #21100379 | | | | | | 1) SPECIFY THAT THE FLOOD ELEVATIONS ARE USING NAVD 88 | | | ON THE PLANS. FBC-R322 | | | | | | 2) SPECIFY THE ELEVATION OF THE ATTACHED GARAGE ON THE | | | PLANS. FBC-R322 | | | | | | 3) SPECIFY WHETHER THE FLOOD OPENINGS IN THE GARAGE | | | WALLS ARE ENGINEERED OR NON-ENGINEERED OPENINGS. | | | PROVIDE CALCULATIONS ON THE PLANS TO SHOW THAT THE | | | FLOOD OPENINGS IN THE GARAGE COMPLY WITH FBC-R 322.2.2. | | | IF ENGINEERED FLOOD VENTS, SUCH AS "SMART VENTS", ARE | | | USED SUBMIT THE EVALUATION REPORT FOR THEM. | | | | | | 4) SUBMIT A SIGNED AND SEALED PRE-CONSTRUCTION | | | ELEVATION CERTIFICATE BASED ON THE CONSTRUCTION | | | DRAWINGS. CITY ORDINANCE 4729-17 | | | | | | NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR | | | ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS | | | ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH | | | FLOOR ELEVATIONS FOR REVIEW. | | | CITY ORDINANCE 4729-17. | | | SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE. | | | SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT | | | FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED: | | | A) CONSTRUCTION DRAWINGS. | | | B) BUILDING UNDER CONSTRUCTION. | | | C) FINISHED CONSTRUCTION. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-05-02 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-05-02 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2022-05-02 17:22:54 | NFIP REVIEW COMMENTS: | | | PERMIT #21100379 | | | | | | NOTE: | | | SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | 1) SPECIFY THAT THE FLOOD ELEVATIONS ARE USING NAVD 88 | | | ON THE PLANS. FBC-R322 | | | | | | 2) SPECIFY THE ELEVATION OF THE ATTACHED GARAGE ON THE | | | PLANS. FBC-R322 | | | | | | 3) SPECIFY WHETHER THE FLOOD OPENINGS IN THE GARAGE | | | WALLS ARE ENGINEERED OR NON-ENGINEERED OPENINGS. | | | PROVIDE CALCULATIONS ON THE PLANS TO SHOW THAT THE | | | FLOOD OPENINGS IN THE GARAGE COMPLY WITH FBC-R 322.2.2. | | | IF ENGINEERED FLOOD VENTS, SUCH AS "SMART VENTS", ARE | | | USED SUBMIT THE EVALUATION REPORT FOR THEM. | | | | | | 4) SUBMIT A SIGNED AND SEALED PRE-CONSTRUCTION | | | ELEVATION CERTIFICATE BASED ON THE CONSTRUCTION | | | DRAWINGS. CITY ORDINANCE 4729-17 | | | | | | NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR | | | ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS | | | ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH | | | FLOOR ELEVATIONS FOR REVIEW. | | | CITY ORDINANCE 4729-17. | | | SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE. | | | SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT | | | FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED: | | | A) CONSTRUCTION DRAWINGS. | | | B) BUILDING UNDER CONSTRUCTION. | | | C) FINISHED CONSTRUCTION. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-03 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-03 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2021-12-03 14:09:00 | NFIP REVIEW COMMENTS: | | | PERMIT #21100379 | | | | | | NOTE: | | | SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | 1- THE PROPOSED ADDITION IS GOING TO BE BUILT IN A AE | | | FLOOD ZONE WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET | | | BASED ON NAVD 88. | | | THE PROPOSED ADDITION AND ALTERATION IS CONSIDERED A | | | SUBSTANTIAL IMPROVEMENT. THE ADDITION AND THE EXISTING | | | HOUSE SHALL HAVE THE LOWEST FLOOR FINISHED ELEVATION | | | ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION PLUS TWO | | | FEET. | | | THEREFORE, THE MIN. REQUIRED FINISHED FLOOR ELEVATION | | | IS 9 FEET. | | | NOTE: PLANS NEED TO SHOW THE PROPOSED FINISHED FLOOR | | | ELEVATION. NEED TO PROVIDE THE CONSTRUCTION DRAWINGS | | | ELEVATION CERTIFICATE AND SURVEY SHOWING THE FINISH | | | FLOOR ELEVATIONS FOR REVIEW. | | | CITY ORDINANCE 4729-17. | | | SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE. | | | SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | DURING THE PERMITTING OF THIS STRUCTURE THREE DIFFERENT | | | FLOOD ELEVATION CERTIFICATES WILL BE REQUIRED: | | | A) CONSTRUCTION DRAWINGS. | | | B) BUILDING UNDER CONSTRUCTION. | | | C) FINISHED CONSTRUCTION. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-07 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-22 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-22 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2021-10-22 16:11:00 | 10/22/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
N |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-31 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2023-03-31 14:09:42 | | | | SUBMIT ALL ROOFING PRODUCT APPROVAL FOR REVIEW UNDER | | | ROOFING SUB-PERMIT. JG | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2022-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-26 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-26 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2022-10-26 18:20:41 | ROOFING REVIEW: | | | | | | PREVIOUS COMMENT: | | | 1- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. CONTRACTOR TO ADVISE IF SUBMITTING NOW OR | | | LATER AS A DEFERRED SUBMITTAL). | | | | | | A) PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON | | | PLANS. | | | | | | B) RIDGE VENTS AS SPECIFIED ON PLANS. (NOA 11-0928.01 | | | IS EXPIRED). | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | | | | RESPONSE: | | | ACCORDING TO ENGINEER OF RECORD RESPONSE LETTER ALL | | | PRODUCT APPROVALS WILL BE APPROVED AND WILL BE | | | SUBMITTED LATER AS DEFERRED SUBMITTALS. | | | ONLY SOME PRODUCT APPROVALS WERE SUBMITTED AT THIS TIME | | | AND THEY WERE NOT REVIEWED/APPROVED BY THE DESIGNER OF | | | RECORD. ALSO, THE FLOOD VENT PRODUCT APPROVAL SUBMITTED | | | IS INCOMPLETE. IT NEEDS THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE AND INSTALLATION INSTRUCTIONS. TO SAVE TIME, | | | ALL PRODUCT APPROVALS SUBMITTED THIS TIME WILL BE | | | BLOCKED AND WILL NOT BE REVIEWED AT THIS TIME. | | | CONTRACTOR TO ADVISE IF SUBMITTING ALL THE PRODUCT | | | APPROVALS (COMPLETE REPORTS) LATER AS A DEFERRED | | | SUBMITTAL ONCE THEY ARE APPROVED BY THE DESIGNER OF | | | RECORD OR IF SUBMITTING THEM ON NEXT RESUBMITTAL. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-19 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-19 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2022-07-19 13:07:34 | ROOFING REVIEW: | | | | | | 1- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A) PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON | | | PLANS. | | | | | | B) RIDGE VENTS AS SPECIFIED ON PLANS. (NOA 11-0928.01 | | | IS EXPIRED). | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | NOTE; | | | SHINGLES NOA 18-0207.04 SUBMITTED IS OK BUT IT NEEDS | | | ENGINEER OF RECORD APPROVAL. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-05-09 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-05-06 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2022-05-09 09:07:04 | NOA 18-0207.04 SHINGLES | | | FL 11-0928.01 RIDGE VENT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-03 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-03 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2021-12-03 14:07:06 | ROOFING REVIEW: | | | | | | 1- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A) PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON | | | PLANS. | | | | | | B) RIDGE VENTS AS SPECIFIED ON PLANS. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | NOTE; | | | SHINGLES NOA 18-0207.04 SUBMITTED IS OK BUT IT NEEDS | | | ENGINEER OF RECORD APPROVAL. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-31 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-07 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-19 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-19 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2022-07-19 13:25:04 | SIGNATURE REVIEW: | | | | | | 1- THE FOLLOWING DRAWINGS HAVE A DIGITAL SIGNATURE THAT | | | CAN NOT BE VERIFIED. A0, A1, A2, A8, A10, A11, M2, E1, | | | E2, P1, P3. | | | ALL DRAWINGS/DOCUMENTS NEED TO HAVE VERIFIABLE ORIGINAL | | | DIGITAL SEAL/SIGNATURE AS REQUIRED BY CHAPTER 471 F.S. | | | WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS. | | | NOTE: NEED TO SUBMIT DRAWINGS ELECTRONICALLY WITH | | | VERIFIABLE ORIGINAL DIGITAL SIGNATURE | | | | | | 2- DRAWING C1 HAVE A COPY OF ENGINEER'S SEAL AND | | | SIGNATURE. NEED ENGINEER'S ORIGINAL SEAL AND SIGNATURE | | | AS REQUIRED BY CHAPTER 471 F.S. WHEN SUBMITTING | | | DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | 3- SOIL TEST REPORT HAVE A COPY OF ENGINEER'S SEAL AND | | | SIGNATURE. NEED ENGINEER'S ORIGINAL SEAL AND SIGNATURE | | | AS REQUIRED BY CHAPTER 471 F.S. WHEN SUBMITTING | | | DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED | | | PLANS/DOCUMENTS WITH YOUR RESUBMITTAL IN PROJECTDOX, OR | | | YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | | | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-05-09 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-05-06 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2022-05-03 11:07:24 | SHEET M-2 APPEARS TO BE A COPY OF THE DIGITAL | | | SIGNATURE. PLEASE SUBMIT THE ORIGINAL DIGITALLY SIGNED | | | DRAWING. ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-12 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-12 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2021-10-12 16:32:17 | ALL PRINTS OR DRAWINGS APPEAR TO BE DIGITAL COPIES | | | WHICH ARE NOT ACCEPTABLE ACCORDING TO FLORIDA STATUES, | | | PLEASE SEE BELOW HOW TO CORRECT THESE ISSUES | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. A COPY OF A SIGNED | | | PLAN IS NOT CONSIDERED AN ORIGINAL.IT APPEARS THE | | | ENGINEER HAS A DIGITAL SIGNATURE PLEASE EMAIL THE | | | ORIGINAL DIGITALLY SIGNED DOCUMENT | | | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | | | | | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2023-04-13 |
|
|
Cont ID |
|
| Sent By |
VBroglia |
Date |
2023-04-13 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-04-13 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
VBroglia |
Date |
2023-03-27 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-03-27 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2023-03-27 16:06:09 | PREVIOUS COMMENT NOT ADDRESSSED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-11-17 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-11-17 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2022-11-17 14:08:18 | 11/17/2022 FAILED | | | | | | PLEASE APPLY FOR A LANDSCAPE PERMIT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-06-23 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-06-23 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2022-06-23 13:32:11 | 6/23/22 FAILED | | | | | | PLEASE APPLY FOR A LANDSCAPE PERMIT TO ALLOW STAFF TO | | | MOVE PERMIT FORWARD | | | | | | PLEASE SEE PREVIOUS COMMENTS FOR LANDSCAPE PLANNER | | | CONTACT | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-04-26 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-04-26 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2022-04-26 09:31:04 | 4/26/2022 | | | FAIL | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING LOCATED IN | | | SINGLE FAMILY LOW DENSITY ZONING | | | REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER IS | | | LESS; | | | | | | THE VALUE OF THE CONSTRUCTION ($420,000) EXCEEDS 50% OF | | | THE STRUCTURE'S VALUE ($157,682) ACCORDING TO THE | | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | | SITE INTO CONFORMITY. | | | | | | PLEASE GET INTO CONTACT WITH RAY CARANCI THE CITY'S | | | LANDSCAPE PLANNER [email protected] | | | | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-10-27 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2021-10-27 |
Time |
|
Sent To |
I |
|
| Notes |
| 2021-10-27 09:52:43 | INTERIOR WORK/REMODEL | | | (NO CHANGES IN DENSITY) - PASS ZONING |
|
|