Plan Review Details - Permit 21100215
Plan Review Stops For Permit 21100215
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-12-14 Cont ID  
Sent By jwitmer Date 2021-12-14 Time 10:35 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-11-02 Cont ID  
Sent By jwitmer Date 2021-11-02 Time 07:32 Rev Time 0.00
Received By jwitmer Date 2021-11-01 Time 17:21 Sent To  
Notes
2021-11-02 07:32:36TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-12-14 Cont ID  
Sent By jwitmer Date 2021-12-14 Time 10:31 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-11-02 Cont ID  
Sent By jwitmer Date 2021-11-02 Time 07:31 Rev Time 0.00
Received By jwitmer Date 2021-11-01 Time 17:21 Sent To  
Notes
2021-11-02 07:31:48WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21100215
 ADD: 1900 CONSULATE PL. # 406
 CONT: NARUS MODERN CONCEPTS LLC
 TEL: 5613606589
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 02ND/ 2021
 ACTION: DENIED
  
 1) THE SUBMITTED FLOOR PLAN IS LIGHT, SMUDGED, VERY
 HARD TO READ. 2020 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 SECTION 107.2.1.3. QUALITY OF PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A 1/8TH INCH SCALE ON SUBSTANTIAL
 PAPER. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENT POLICY OTHER STANDARDS FOR THE PLANS AND
 SPECIFICATIONS IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORD MANAGEMENT. ELECTRONIC
 MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS
 OF FLORIDA STATUTES.
  
 2) FLOOR PLAN AND SOFFIT DETAIL. IF THE CONTRACTOR
 DRAWS THE FLOOR PLAN SHOW COMPLIANCE WITH CERTIFICATION
 BY CONTRACTOR. 107.3.4.3. THE CONTRACTOR (QUALIFIER)
 THAT CREATED / DREW THE SET OF PLANS WILL NEED TO
 IDENTIFY THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE
 PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR
 THE TRADE YOU ARE LICENSED IN AND PLANS DRAWN.
  
 3) SOFFIT DETAIL, WITH THE SUBMITTED FLOOR PLAN
 ELIGIBLE PLEASE PROVIDE THE LOCATION OF SOFFIT IN
 RELATION TO THE FLOOR PLAN. 2ND. THE SOFFIT DETAIL DOES
 NOT INDICATE THE DROP OF THE SOFFIT, THE VERTICAL
 CLEARANCE TO FINISH FLOOR NOR THE DEPTH/ HORIZONTAL
 DISTANCE OF THE SOFFIT. MISSING THE TYPE OF SOFFIT
 FINISH MATERIAL AND THICKNESS. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 4) THE FLOOR PLAN DOES NOT INDICATE THE AREAS THAT WILL
 RECEIVE THE NEW FLOORING, CROSS HATCH ON THE FLOOR PLAN
 AND PROVIDE THE SQUARE FOOT AREA. THE FLOOR PLAN NOR
 PERMIT APPLICATION DOES NOT INDICATE WHAT TYPE OF
 FINISH FLOOR SURFACE IS TO BE INSTALLED. THE CORELUXE
 PREMIUM UNDERLAYMENT SUBMITTED IS ONLY A SALES BROCHURE
 NOT A TEST REPORT.
  
 FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE,
 STONE, MARBLE, VINYL LAMINATE FLOORING AND WOOD
 FLOORING ALL NEED TO HAVE HAD THE SOUND UNDERLAYMENT
 TESTED FLOOR ASSEMBLIES TO THE FOLLOWING STANDARDS AND
 MEET THE QUALIFICATIONS LISTED UNDER EACH OF THE
 STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ NO
 DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 4A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 4B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 4C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 LVT & LPT LUXURY VINYL TILE. FLOOR FINISH
 CLASSIFICATION AS REQUIRED IN SECTION 804.2
 CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF
 THE 2020 FBC-B.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-20 Cont ID  
Sent By jleahy Date 2021-12-20 Time 14:46 Rev Time 0.00
Received By jleahy Date 2021-12-20 Time 12:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-11-18 Cont ID  
Sent By jleahy Date 2021-11-18 Time 13:40 Rev Time 0.00
Received By jleahy Date 2021-11-18 Time 12:14 Sent To  
Notes
2021-11-18 13:41:21ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRICAL WORK SHOWN.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-12-14 Cont ID  
Sent By cwalker Date 2021-12-14 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-10-07 Cont ID  
Sent By cwalker Date 2021-10-07 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-20 Cont ID  
Sent By jleahy Date 2021-12-20 Time 14:47 Rev Time 0.00
Received By jleahy Date 2021-12-10 Time 06:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-18 Cont ID  
Sent By lmarchan Date 2021-11-18 Time 15:08 Rev Time 0.00
Received By lmarchan Date 2021-10-06 Time 11:53 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2021-11-02 Cont ID  
Sent By jwitmer Date 2021-11-02 Time 07:32 Rev Time 0.00
Received By jwitmer Date 2021-11-01 Time 17:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2021-12-20 Cont ID  
Sent By medwards Date 2021-12-20 Time 14:42 Rev Time 0.00
Received By medwards Date 2021-12-20 Time 14:42 Sent To  
Notes
2021-12-20 14:43:40SCOPE OF WORK STATES NO MECHANICAL SYSTEM ALTERATIONS.
 ME

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-11-01 Cont ID  
Sent By medwards Date 2021-11-01 Time 10:04 Rev Time 0.00
Received By medwards Date 2021-11-01 Time 10:04 Sent To  
Notes
2021-11-01 10:08:30IT APPEARS THAT THE KITCHEN CEILING IS GOING TO BE NEW.
 PLEASE PROVIDE A SCOPE OF WORK FOR THE MECHANICAL
 SYSTEM ALTERATIONS AND A MECHANICAL DRAWING SHOWING THE
 ALTERATIONS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-12-17 Cont ID  
Sent By lcrespo Date 2021-12-17 Time 14:44 Rev Time 0.00
Received By lcrespo Date 2021-12-17 Time 14:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-11-03 Cont ID  
Sent By lcrespo Date 2021-11-03 Time 06:18 Rev Time 0.00
Received By lcrespo Date 2021-11-03 Time 06:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-12-20 Cont ID  
Sent By jleahy Date 2021-12-20 Time 14:47 Rev Time 0.00
Received By jleahy Date 2021-12-20 Time 14:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-11-18 Cont ID  
Sent By jleahy Date 2021-11-18 Time 13:41 Rev Time 0.00
Received By jleahy Date 2021-11-18 Time 12:15 Sent To  
Notes
2021-11-18 13:42:21PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1