| Plan Review Stops For Permit 21100214 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-31 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-31 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2021-10-31 10:00:12 | HABITABLE STRUCTURE GIVEN ADDRESS OF 241 MURRAY RD |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-01-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-29 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-29 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-08 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-08 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-25 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-25 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2021-10-25 16:39:05 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. PROVIDE AN ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 2. STATE R-VALUE OF FOIL FACED SEMI-PERMEABLE MASONRY | | | WALL INSULATION. SEE PLAN PAGE A4.0. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-10-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-26 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-26 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-01-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-30 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-27 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-08 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-01 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-06 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-25 |
Time |
12:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2022-02-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-02-02 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-31 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2022-02-02 16:52:53 | RECEIPT MU-2022-04801 - $6350.41 PAID | | 2022-01-31 10:00:19 | 1/31/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2022-01-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-30 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-08 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-11-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-06 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-06 |
Time |
17:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-01-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-29 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-29 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-03 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-03 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2021-12-03 07:41:51 | PLANS FOR THIS PROJECT ARE WITH PERMIT 21081320 | | | | | | PLEASE RESPOND TO 2ND CYCLE REVIEW COMMENTS BELOW. | | | | | | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21081320 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 2 OF 18 LISTS THE TYPE OF PROJECT AS | | | MULTIFAMILY FOR BOTH THE MAIN HOUSE AND THE CABANA. THE | | | PERMIT APPLICATION IS FOR A NEW RESIDENTIAL STRUCTURE | | | AND A CABANA-ACCESSORY STRUCTURE. | | | | | | 2) THE 2 RESCHECK REPORTS ARE IDENTICAL AND FOR A | | | CONDITIONED FLOOR AREA OF 4850 SQ FT. NEITHER OF THESE | | | PROJECT HAVE A FLOOR AREA OF THIS SIZE. PLEASE SUBMIT A | | | RESCHECK FOR EACH STRUCTURE SEPARATELY. | | | | | | 3) THE CONDENSATE CANNOT TERMINATE IN THE SANITARY | | | SYSTEM. PLEASE SHOW THE CONDENSATE TERMINATION LOCATION | | | OUTSIDE OF THE STRUCTURE. FBC RES M1411.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-25 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-25 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2021-10-25 17:07:52 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21100214 | | | RESULTS FOR BOTH MAIN HOUSE AND CABANA | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 2 OF 18 LISTS THE TYPE OF PROJECT AS | | | MULTIFAMILY FOR BOTH THE MAIN HOUSE AND THE CABANA. THE | | | PERMIT APPLICATION IS FOR A NEW RESIDENTIAL STRUCTURE | | | AND A CABANA-ACCESSORY STRUCTURE. | | | | | | 2) THE 2 RESCHECK REPORTS ARE IDENTICAL AND FOR A | | | CONDITIONED FLOOR AREA OF 4850 SQ FT. NEITHER OF THESE | | | PROJECT HAVE A FLOOR AREA OF THIS SIZE. PLEASE SUBMIT A | | | RESCHECK FOR EACH STRUCTURE SEPARATELY. | | | | | | 3) THE CONDENSATE CANNOT TERMINATE IN THE SANITARY | | | SYSTEM. PLEASE SHOW THE CONDENSATE TERMINATION LOCATION | | | OUTSIDE OF THE STRUCTURE. FBC RES M1411.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-11-03 |
Time |
06:50 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-11-03 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2021-11-03 06:51:11 | PEMITTED PLANS UNDER 21081320 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-25 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-25 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2021-10-25 16:41:34 | PROVISO ON PLAN PAGE A-4: A SEPERATE ROOFING PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-01-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-29 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-29 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-08 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-08 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2022-01-08 08:25:05 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: MECH., ELECTRICAL & PLUMBING PLANS: DIGITAL | | | SIGNATURE HAS BEEN SELF CERTIFIED BY EOR, ANDREW | | | SILVERSTEIN, P.E. | | | FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGNATURES AND SEALS PER FS 668.003. | | | THE DESIGNER OF THE STRUCTURAL SHEETS CANNOT | | | SELF-CERTIFY THEIR DIGITAL SIGNATURE. THE SIGNATURE | | | MUST BE THIRD PARTY VERIFIED. | | | 61G15-23.004 F.A.C. | | | | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-25 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-25 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2021-10-25 16:40:30 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: PLAN PAGES C-1, C-2, ALL STRUCTURAL PLANS. | | | | | | NOTICE: DIGITAL SIGNATURE ON STRUCTURAL PLANS HAVE BEEN | | | SELF CERTIFIED BY ANDREW SILVERSTEIN, P.E. ENGINEERS | | | MAY N OT SELF CERTIFY THEIR DIGITAL SIGNATURES PER RULE | | | FS 668.003. | | | USE A THIRD PARTY TO CERTIFY DIGITAL SIGNATURE. | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-27 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-12-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-12-27 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-11-05 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-11-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-11-05 10:36:21 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) APPROVAL OF MASTER PERMIT #21081320 REQUIRED PRIOR | | | TO THE APPROVAL OF THIS PERMIT. | | | | | | 2.) THE TOTAL FLOOR AREA OF ALL ROOFED ACCESSORY | | | BUILDINGS ON A PROPERTY SHALL NOT EXCEED 75 PERCENT OF | | | THE GROSS FLOOR AREA OF THE PRIMARY STRUCTURE WITH A | | | MAXIMUM FLOOR AREA OF 1,000 SQUARE FEET. THE PROPOSED | | | ACCESSORY STRUCTURE EXCEEDS THIS MAXIMUM ALLOWABLE | | | BUILDING SQUARE FOOTAGE. [ZLDR S.94-304(B)(1)] | | | | | | 3.) SHOW DIMENSION ILLUSTRATING THE DISTANCE SEPARATION | | | BETWEEN THE ACCESSORY STRUCTURE AND THE PRIMARY | | | RESIDENCE TO DEMONSTRATE THAT IT MEETS THE MINIMUM 6 | | | FT. DISTANCE SEPARATION REQUIREMENT BETWEEN STRUCTURES. | | | [ZLDR S.94-304(B.)(3)] | | | | | | 4.) OVERALL HEIGHT OF THE BUILDING (FROM GRADE TO THE | | | TALLEST POINT OF THE STRUCTURE) CANNOT EXCEED 27.5 FT. | | | TOTAL. THE STRUCTURAL ELEMENTS THAT ARE PERMITTED THE | | | 10% HEIGHT EXCEPTION ABOVE THE MAXIMUM ALLOWABLE | | | BUILDING HEIGHT OF 25 FT. EXCEEDS THE LIMITATION. [ZLD | | | S.94-305(B.)(4) AND S.94-306] | | | | | | 5.) MECHANICAL EQUIPMENT MAY NOT ENCROACH MORE THAN 4 | | | FT. INTO A REQUIRED SETBACK. THERE IS AN A/C COMPRESSOR | | | UNIT ON THE SOUTH SIDE OF THE PROPOSED STRUCTURE | | | ILLUSTRATED IN THE FLOOR PLAN BUT NOT IN THE SITE PLAN. | | | PLANS MUST MATCH FOR CONSISTENCY. ALSO, THE DIMENSION | | | OF THE COMPRESSOR PAD TO THE PROPERTY LINE MUST BE | | | PROVIDED TO DEMONSTRATE CONSISTENCY WITH THE | | | REQUIREMENTS OF THE ZLDRS. [ZLDR S.94-305(B.)(4)] | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF14 | | | | | | * MASTER PERMIT #21081320 (NEW SFR) | | | |
|
|