| 2021-11-14 11:02:57 | BUILDING PLAN REVIEW |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | |
| | 1. VALUE |
| | CITY OF WPB CHPT109.3 BUILDING PERMIT VALUATIONS. |
| | 1A. VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF WORK. |
| | 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE |
| | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED |
| | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, |
| | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE |
| | OF WORK. |
| | 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY |
| | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT |
| | RENTAL TO VERIFY VALUE. |
| | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| | BUILDING OFFICIAL |
| | |
| | |
| | 2. PROVIDE AN EXTERIOR WALL DETAIL. INCLUDE THE |
| | FOLLOWING: |
| | |
| | SECTIONR602 |
| | WOOD WALL FRAMING |
| | SECTIONR604 |
| | WOOD STRUCTURAL PANELS |
| | R604.3INSTALLATION. |
| | WOOD STRUCTURAL PANEL WALL SHEATHING SHALL BE ATTACHED |
| | TO FRAMING IN ACCORDANCE WITH SECTION R602.3. |
| | R602.3DESIGN AND CONSTRUCTION. |
| | TABLE R602.3(1) FASTENING SCHEDULE. |
| | |
| | SECTIONR703 |
| | EXTERIOR COVERING |
| | R703.1GENERAL. |
| | EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A |
| | WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. |
| | R703.1.1WATER RESISTANCE. |
| | THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND |
| | CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION |
| | OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A |
| | WATER-RESISTANT BARRIER BEHIND THE EXTERIOR CLADDING AS |
| | REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO |
| | THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR |
| | CLADDING. |
| | R703.2WATER-RESISTIVE BARRIER. |
| | R703.4FLASHING. |
| | R703.7EXTERIOR PLASTER. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | PLEASE UPLOAD YOUR DOCUMENTS TO PROJECT DOX. DO NOT |
| | E-MAIL DOCUMENTS TO THE PLANS EXAMINER. |
| | |
| | |