Plan Review Details - Permit 21100157
Plan Review Stops For Permit 21100157
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-12-21 Cont ID  
Sent By jwitmer Date 2021-12-21 Time 15:40 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-10-27 Cont ID  
Sent By jwitmer Date 2021-10-27 Time 13:15 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2021-10-27 13:15:21TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-12-21 Cont ID  
Sent By jwitmer Date 2021-12-21 Time 15:49 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-27 Cont ID  
Sent By jwitmer Date 2021-10-27 Time 13:53 Rev Time 0.00
Received By jwitmer Date 2021-10-27 Time 13:15 Sent To  
Notes
2021-10-27 13:53:34WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21100157
 ADD: 1721 PALM BEACH LAKES BLVD. # E409
 CONT: TBD/ TO BE DETERMINED
 TEL: ???
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. OCT. 27TH/ 2021
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION AND TITLEBLOCK OF PLANS BOTH
 HAVE THE STREET IDENTIFIED AS PRESIDENTIAL WAY. THE
 TOTAL OF THE PALM BEACH OUTLET MALL IS ADDRESSED OFF
 PALM BEACH LAKES BLVD. PLEASE VERIFY THE UNIT ADDRESS
 WITH CAROLINE PUELL 561-805-6659.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED.
 2020 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS IDENTIFICATION.
  
 2) THE COVERSHEET UNDER OCCUPANCY CLASSIFICATIONS LIST
 FOR THE SALES AREA A OCCUPANT LOAD FACTOR OF 30. PLEASE
 REVIEW IN HE 2020 FBC-BUILDING CODE TABLE 1004.5 THE
 OCCUPANT LOAD FACTOR FOR MERCANTILE IS 60 NOT 30.
 PLEASE UPDATE THE PLANS.
  
 3) SHEET A10 THE ENLARGE RESTROOMS, THE FLOOR PLAN IS
 MISSING THE CLEAR FLOOR SPACE REQUIRED FOR THE
 WATERCLOSET. IT APPEARS THE SERVICE SINK MAYBE
 ACCROACHING. CLEARANCES AT WATER CLOSETS. 604.3
 CLEARANCE. CLEARANCES AROUND THE WATER CLOSETS AND IN
 TOILET COMPARTMENTS SHALL COMPLY WITH 604.3.
 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR
 WALL.
  
 4) SHEET A-1 THE CONSTRUCTION PLAN DOES NOT SHOW A
 BENCH IN THE ACCESSIBLE DRESSING ROOM. 2020 FBC-ACCESS.
 CODE SECTION 803.4 BENCHES. A BENCH COMPLYING WITH 903
 SHALL BE PROVIDED WITHIN THE ROOM.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-23 Cont ID  
Sent By jleahy Date 2021-12-23 Time 07:28 Rev Time 0.00
Received By jleahy Date 2021-12-23 Time 07:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-10-23 Cont ID  
Sent By jleahy Date 2021-10-23 Time 10:00 Rev Time 0.00
Received By jleahy Date 2021-10-23 Time 09:17 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-10-23 Cont ID  
Sent By jleahy Date 2021-10-23 Time 10:02 Rev Time 0.00
Received By jleahy Date 2021-10-23 Time 10:02 Sent To  
Notes
2021-10-23 10:02:42VOICE AND DATA JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-12-17 Cont ID  
Sent By   Date 2021-12-17 Time   Rev Time 0.00
Received By jcclark Date 2021-12-17 Time 15:09 Sent To  
Notes
2021-12-17 15:10:54PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 JOSEPH CLARK
 OFFICE OF THE FIRE MARSHAL
 561-804-4748
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-10-08 Cont ID  
Sent By   Date 2021-10-08 Time   Rev Time 0.00
Received By bdolan Date 2021-10-08 Time 10:57 Sent To  
Notes
2021-10-08 11:03:37SUBJECT TO FIELD INSPECTIONS.
  
 PASS FIRE.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-31 Cont ID  
Sent By shill Date 2021-12-31 Time 10:05 Rev Time 0.00
Received By shill Date 2021-12-16 Time 09:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2021-10-27 Time   Rev Time 0.00
Received By cdecoeur Date 2021-10-06 Time 08:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-12-20 Cont ID  
Sent By medwards Date 2021-12-20 Time 08:18 Rev Time 0.00
Received By medwards Date 2021-12-20 Time 08:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-10-15 Cont ID  
Sent By hmoser Date 2021-10-15 Time 10:35 Rev Time 0.00
Received By hmoser Date 2021-10-15 Time 10:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-12-17 Cont ID  
Sent By lcrespo Date 2021-12-17 Time 14:52 Rev Time 0.00
Received By lcrespo Date 2021-12-17 Time 14:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-10-26 Cont ID  
Sent By lcrespo Date 2021-10-26 Time 07:46 Rev Time 0.00
Received By lcrespo Date 2021-10-25 Time 14:10 Sent To  
Notes
2021-10-26 07:46:3810/26/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
 1. ON SHEET A-1 AND OR A-10;
  
 A. WOULD YOU PLEASE LABEL THE RESTROOM THAT REQUIRED A
 PUBLIC FACILITY TO PROVIDE SIGNS THAT DESIGNATE THE SEX
 PER THE 2020 FBC SECTION P 403.2.
  
 B. WOULD YOU PLEASE SHOW A SERVICE SINK (MOP SINK), AND
 THE SURROUNDING WALLS SHALL BE NON-ABSORBENT SURFACE IN
 ACCORDANCE WITH THE 2020 FBC BUILDING SEC. 1210.2.2 AND
 2020 FBC SEC. P 310.3. WOULD YOU PLEASE MAKE A NOTE ON
 THIS SHEET?
  
 C. THERE IS A MOP SINK IN FRONT OF THE WATER CLOSER TO
 RESTROOM TWO. WOULD YOU PLEASE SHOW THE CLEAR FLOOR
 SPACE SHALL BE 60 INCHES MINIMUM MEASURED PERPENDICULAR
 FROM THE SIDEWALL AND 56 INCHES MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL PER THE 2020 FBC ACC.
 SEC. 604.3.1.
  
 D. WOULD YOU, PLEASE SHOW THE 30 INCHES BY 48 INCHES
 INSIDE THE RUNNING RADIUS PER THE 2020 FBC ACC SEC. 305
 CLEAR FLOOR OR GROUND SPACE.
  
 E. ON SHEET A-10 DETAIL, FOUR SHALL BE INSTALLED
 HORIZONTALLY PER THE 2020 FBC ACC SEC. 609.4. THE
 HORIZONTAL GRAB BARS NEED TO BE MEASURED TO THE CENTER
 OF THE BAR PER THE 2020 FBC ACC SEC. 604.5.1 SIDE WALL
 AND 604.5.2 REAR WALL. THE REFLECTIVE PART OF THE
 MIRROR NEEDS TO BE 40 INCHES TO THE REFLECTIVE SIDE PER
 THE 2020 FBC ACC SEC. 603.3.
  
 F. WOULD YOU PLEASE PROVIDE A SLAB REPAIR? SHOW THE
 WIDTH OF THE REPAIR, THE MINIMUM THICKNESS OF THE
 CONCRETE TO BE REPLACED, AND THE PSI OF THE CONCRETE.
 SHOW THE SIZE AND LENGTH OF THE DOWELS, THE MINIMUM
 EMBEDMENT DEPTH INTO THE EXISTING SLAB, AND THE SPACING
 OF THE DOWELS IN THE CENTER. THE REPAIR SHALL ALSO
 INCLUDE TERMITE TREATMENT OF THE SOIL AND THE REQUIRED
 VAPOR BARRIER OVER THE SOIL. A COPY OF THE TERMITE
 CERTIFICATE SHALL BE ONSITE FOR A FINAL INSPECTION.
  
 2. ON SHEET P-1;
  
 A. WOULD YOU PLEASE LABEL THE RESTROOM THAT REQUIRED A
 PUBLIC FACILITY TO PROVIDE SIGNS THAT DESIGNATE THE SEX
 PER THE 2020 FBC SECTION P 403.2. WOULD YOU PLEASE DO
 THIS FOR ALL SIMILAR PAGES UNDER ALL TRADES?
  
 B. WOULD YOU PLEASE PROVIDE THE MINIMUM NUMBER OF
 FIXTURES FOR THE OCCUPANT LOAD BASED ON THE ACTUAL USE
 OF THE BUILDING OR SPACE PER TABLE 403.1 MINIMUM NUMBER
 OF FIXTURES.
  
 C. SEATS OF WATER CLOSETS SHALL BE OPEN-FRONT TYPE PER
 2020 FBC P 425.3 WATER CLOSET SEATS.
  
 D. LAVATORY WATER SUPPLY AND DRAINPIPES UNDER THE SIDE
 SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
 AGAINST CONTACT PER THE 2020 FBC ACC SEC. 606.5.
  
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-12-23 Cont ID  
Sent By jleahy Date 2021-12-23 Time 07:27 Rev Time 0.00
Received By jleahy Date 2021-12-23 Time 07:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-10-25 Cont ID  
Sent By mpeterso Date 2021-10-25 Time 14:12 Rev Time 0.00
Received By mpeterso Date 2021-10-25 Time 14:12 Sent To  
Notes
2021-10-25 14:13:32REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED

Review Stop Z ZONING
Rev No 2 Status P Date 2021-12-30 Cont ID  
Sent By eschneid Date 2021-12-30 Time 14:28 Rev Time 0.25
Received By eschneid Date 2021-12-30 Time 14:15 Sent To  
Notes
2021-12-30 14:29:23ALL EXTERIOR SIGNAGE REQUIRES A SEPARATE PERMIT. NOTE:
 THE VINYL STORE NAME ON THE BACK DOOR IS AN EXTERIOR
 SIGN AND INFORMATION MUST BE PROVIDED WITH THE PERMIT
 TO SHOW HOW THIS SIGN CONFORMS TO THE NORTH FACADE SIGN
 LOCATION AND SQUARE FOOTAGE ALLOWANCE.

Review Stop Z ZONING
Rev No 1 Status F Date 2021-10-07 Cont ID  
Sent By eschneid Date 2021-10-07 Time 12:35 Rev Time 0.50
Received By eschneid Date 2021-10-07 Time 12:35 Sent To  
Notes
2021-10-07 12:38:39FAILED
  
 1) THE PALM BEACH OUTLETS MANAGEMENT APPROVAL NEEDS TO
 BE INCLUDED ON THE PLANS. ALTERNATIVELY, YOU MAY
 PROVIDE AN APPROVAL LETTER FROM THE PALM BEACH OUTLETS
 MANAGEMENT LISTING THE SPECIFIC PLANS THAT THEY HAVE
 APPROVED.
  
 2) ALL EXTERIOR SIGNAGE REQUIRES A SEPARATE PERMIT.
 NOTE: THE VINYL STORE NAME ON THE BACK DOOR IS AN
 EXTERIOR SIGN AND INFORMATION MUST BE PROVIDED WITH THE
 PERMIT TO SHOW HOW THIS SIGN CONFORMS TO THE NORTH
 FACADE SIGN LOCATION AND SQUARE FOOTAGE ALLOWANCE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]