| 2021-10-15 12:12:53 | 1ST REVIEW FBC-2020 BUILDING |
| | PERMIT- 21091235 |
| | 10/15/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) PLEASE PROVIDE A LEGIBLE ROOF PLAN SHEET R1.04 PLAN |
| | SHEET THAT INDICATES THE TYPES OF ROOFING TO BE |
| | INSTALLED, THE SQUARE FOOT AREAS OF THE ROOFING, AND |
| | THE MEAN ROOF HEIGHTS. A COMPLETE REVIEW OF THE PROJECT |
| | CANNOT BE COMPLETED WITHOUT THIS INFORMATION- SECTION |
| | 1507.1 FBC B. PLEASE NOTE THE PLAN MUST BEAR THE |
| | SIGNATURE OF THE DESIGNER OF RECORD. IF THE DESIGNER IS |
| | AN ARCHITECT OR ENGINEER, THE PLAN SHALL BE DIGITALLY |
| | SIGNED AND SEALED IN ACCORDANCE WITH FL. STATUTES |
| | 471.025, 481.221, AND SECTIONS 61G1-16.005 & |
| | 61G15-23.005 FLORIDA ADMINISTRATIVE CODE. |
| | |
| | 2) MIAMI-DADE NOA 11-0913.08 GAF DECK-ARMOUR |
| | UNDERLAYMENT IS NOT VALID FOR USE WITH THE GAF SHINGLES |
| | WITHOUT ENGINEEREED UPLIFT CALCULATIONS AND FASTENING |
| | DETAILS. REFER TO LIMITATION #8 ON PAGE 4: DECK-ARMOUR |
| | MAY BE USED WITH ANY APPROVED ROOF COVERING NOTICE OF |
| | ACCEPTANCE LISTING DECK-ARMOUR AS A COMPONENT PART OF |
| | AN ASSEMBLY IN THE NOTICE OF ACCEPTANCE. IF DECK-ARMOUR |
| | IS NOT LISTED, A REQUEST MAY BE MADE TO THE AUTHORITY |
| | HAVING JURISDICTION (AHJ) OR THE MIAMI-DADE COUNTY |
| | PRODUCT CONTROL DEPARTMENT FOR APPROVAL PROVIDED THAT |
| | APPROPRIATE DOCUMENTATION IS PROVIDED TO DETAIL |
| | COMPATIBILITY OF THE PRODUCTS, WIND UPLIFT RESISTANCE, |
| | AND FIRE TESTING RESULTS. |
| | |
| | 3) PLEASE SUBMIT A CURRENT FL. PRODUCT APPROVAL FOR THE |
| | FLAT ROOF SYSTEM THAT IS A COMPLETE SUBMITTAL INCLUDING |
| | THE COVER SHEETS, AND EVALUATION REPORT- RULE 9N-3 FAC. |
| | THE CURRENT FL16732-R19 SUBMITTAL IS INCOMPLETE AND HAS |
| | BEEN SUPERSEDED BY R20. PLEASE REVIEW THE LIMITATIONS |
| | OF USE FOR THE PRODUCT- ENGINEERED CALCULATIONS AND |
| | ENHANCED FASTENING FOR ZONES 2 & 3 MAY BE REQUIRED. |
| | PLEASE NOTE THE SUBMITTED DESIGN PRESSURE CALCULATIONS |
| | ARE REFERENCING THE EXPIRED PRODUCT APPROVAL. PLEASE |
| | SUBMIT REVISED AND UPDATED CALCULATIONS WITH THE |
| | UPDATED PRODUCT APPROVAL. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |