| Plan Review Stops For Permit 21091210 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
P |
Date |
2021-12-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-09 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-09 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2021-12-09 14:20:43 | PLANS AND APPLICATION SHOWING CORRECT ADDRESS OF 1230 | | | PALM BEACH LAKES BLVD |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2021-12-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-09 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-09 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2021-12-09 12:09:09 | SPOKE WITH APPLICANT HE RECOGNIZED THAT THE SHEETS HAD | | | NOT BEEN UPDATED BUT WILL WORK ON IT. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-07 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-07 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2021-12-07 12:45:24 | PARCEL SPLIT, NEW PCN 74434316290000020, PREVIOUS | | | COMMENTS STILL NEED TO BE ADDRESSED. ONCE BUILDIN HAS | | | AN OFFICIAL ADDRESS THE PARCEL WILL RECIEVE THE SAME | | | ADDRESS |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-28 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-28 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2021-09-28 12:26:50 | PREVIOUSLY AGREED ADDRESS FOR THIS PROJECT WAS 1230 | | | PALM BEACH LAKES BLVD, WHICH WAS AGREE UPON BY MAXWELL | | | KAPLAN, HOWEVER THIS PERMIT HAS BEEN APPLIED WITH | | | ANOTHER ADDRESS. WHEN I PROPOSED THE ADDRESS I ALSO | | | ASKED IF THE PARCEL WAS TO BE REPLATTED. PLEASE CONTACT | | | [email protected] OR CALL 561-805-6659 TO RESPOND TO | | | COMMENTS. |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
P |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2021-09-27 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
2021-09-27 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2021-09-27 14:19:27 | PUBLIC ART REQUIREMENT COMPLETED 4.06.2022 | | | | | | SUBJECT TO PUBLIC ART REQUIREMENT | | | TOTAL CONSTRUCTION COSTS OF THIS DEVELOPMENT ARE OVER | | | $500,000 IT IS SUBJECT TO THE PUBLIC ART REQUIREMENT AS | | | PER CITY ORDINANCE. | | | | | | SECTION 78-129: ALL PRIVATE DEVELOPMENT PROJECTS, | | | INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR | | | IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL | | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $500,000 ARE SUBJECT TO THE PUBLIC ART REQUIREMENT THAN | | | $500,000 ARE SUBJECT TO THE PUBLIC ART REQUIREMENT. | | | OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE | | | VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE | | | TOTAL CONSTRUCTION COSTS; OR | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF | | | ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT | | | TO THE PUBLIC ART ACCOUNT. | | | | | | A COMPLETED PUBLIC ART ASSESSMENT APPLICATION IS | | | REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL. | | | | | | PLEASE CONTACT SYBILLE WELTER AT [email protected] OR | | | 561.822.1521 TO OBTAIN AN APPLICATION AND REVIEW THE | | | REQUIREMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-08 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-03-08 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-01 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-01 09:57:14 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21091210 / NEW CONSTRUCTION | | | ADD: 1236 PALM BEACH LAKES BLVD. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: ??? | | | E-MAIL: [email protected] JESSICA LALOGGIA | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 3RD REVIEW | | | DATE: TUES. FEB. 01ST/ 2021 | | | ACTION: PASSED/ BUILDING PROVISOS | | | | | | 1) BUILDING PROVISO: THE LIFE SAFETY SHEET A-1.1 SHOWS | | | SHELVING UNITS 90 INCHES IN HEIGHT AND 114 INCHES IN | | | HEIGHT. THERE IS ALSO A NOTE THE MAXIMUM SHELVING UNIT | | | HEIGHT IS 144 INCHES. SHELVING UNITS THAT ARE OVER 60 | | | INCHES IN HEIGHT REQUIRE A SPERATE PERMIT AND REVIEW. | | | 2020 W. P. B. ADMINISTRATIVE CODE SECTION 105.2 (6). | | | THE SHELVING CAN BE REVIEWED UNDER THIS SET OF PLANS A | | | SEPARATE PERMIT APPLICATION AND FEES ARE REQUIRED. | | | | | | 2) BUILDING PROVISO: SHEET S-2 SHOWS THE BAR JOIST | | | SPACING AND REQUIRED ADDITIONAL STEEL FOR RTU AND ROOF | | | HATCH OPENINGS WITHIN THE ROOF FRAMING SYSTEM. WELDED | | | OR BOLTED CONNECTIONS | | | THIS BUILDING CONTAINS EITHER BOLTED AND OR WELDED | | | CONNECTIONS. THE CONTRACTOR IS REQUIRED TO PROVIDE WELD | | | PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT 561-805-6666 OR ACTING CHIEF RICHARD BRUNELL AT | | | 561-805-6670. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-12-14 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-14 13:34:19 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21091210 / NEW CONSTRUCTION | | | ADD: 1236 PALM BEACH LAKES BLVD. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: ??? | | | E-MAIL: [email protected] JESSICA LALOGGIA | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | | | | 2ND REVIEW | | | DATE: TUES. DEC. 14TH/ 2021 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) 2ND REQUEST. FL 14218-R11. AS IN THE PAST WITH AUTO | | | ZONE ALL PRODUCT APPROVALS WERE SUBMITTED HAVE THE | | | DESIGNER OF RECORD STAMP OF APPROVAL, BUT NONE OF THE | | | SUB-SYSTEMS HAVE BEEN IDENTIFIED. PLEASE IDENTIFY IN | | | THE PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE | | | OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR | | | REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND | | | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B | | | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE | | | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S | | | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE | | | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED | | | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. | | | | | | 3A) COMPLIED. THE METAL ROOF REPORT FL 11241-R7 HAS 6 | | | SUB-REPORTS WITH VARYING METALS CONFIGURATIONS AND | | | PRESSURES. | | | | | | 3B) 2ND REQUEST. ROOFING REPORT FL16739-R26 ONLY HAS | | | THE FIRST 2 SHEETS OF THE REPORT. | | | 1ST ROUND COMMENTS. GAF SINGLE PLY ROOF SYSTEM FL | | | 16739-R26 WAS SUBMITTED THE DESIGNER STAMP OF APPROVAL | | | ON THE COVER SHEET, PAGE 1 OF 137, OR SHEET 8 OF 144 | | | HIGHLIGHTED TABLE 2D STEEL DECK NEW ROOF MECHANICALLY | | | FASTENED ROOF PAGES 31-38 OF REPORT IS HIGHLIGHTED. | | | PAGE 31 OF 137 STARTS THE SUB-SYSTEMS TABLE 2 D FOR | | | MECHANICALLY FASTEN ROOF SYSTEMS THROUGH PAGE 38 OF 137 | | | PAGES, NO SUB-SYSTEM IS HIGHLIGHTED. | | | ALSO | | | ALSO ON PAGE 12 OF 137 SYSTEM S-45 HIGHLIGHTED WITH A | | | DESIGN PRESSURE OF -45.0 *. AT THE TOP OF THE SHEET | | | THIS IS FOR STEEL OR CONCRETE DECK. YOU CAN?T HIGHLIGHT | | | 2 SYSTEMS. PLEASE PICK WHICH SUB-SYSTEM IS TO BE | | | INSTALLED. PLEASE ALSO READ WHAT THE * MEANS. SEE PAGE | | | 2 NOTE NUMBER 9 STATES THIS EXTRAPOLATION IS NOT | | | PERMITTED FOR SYSTEMS MARKED WITH AN ASTERISK * MARK. | | | | | | 4) COMPLIED. | | | | | | 5) COMPLIED. | | | | | | 6) BUILDING PROVISO: THE LIFE SAFETY SHEET A-1.1 SHOWS | | | SHELVING UNITS 90 INCHES IN HEIGHT AND 114 INCHES IN | | | HEIGHT. THERE IS ALSO A NOTE THE MAXIMUM SHELVING UNIT | | | HEIGHT IS 144 INCHES. SHELVING UNITS THAT ARE OVER 60 | | | INCHES IN HEIGHT REQUIRE A SPERATE PERMIT AND REVIEW. | | | 2020 W. P. B. ADMINISTRATIVE CODE SECTION 105.2 (6). | | | THE SHELVING CAN BE REVIEWED UNDER THIS SET OF PLANS A | | | SEPARATE PERMIT APPLICATION AND FEES ARE REQUIRED. | | | | | | 7) COMPLIED. STEEL FOR THE TOP BOND BEAM. | | | | | | 8) BUILDING PROVISO: SHEET S-2 SHOWS THE BAR JOIST | | | SPACING AND REQUIRED ADDITIONAL STEEL FOR RTU AND ROOF | | | HATCH OPENINGS WITHIN THE ROOF FRAMING SYSTEM. WELDED | | | OR BOLTED CONNECTIONS | | | THIS BUILDING CONTAINS EITHER BOLTED AND OR WELDED | | | CONNECTIONS. THE CONTRACTOR IS REQUIRED TO PROVIDE WELD | | | PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT 561-805-6666. | | | | | | 9) 2ND REQUEST. SUBMITTED THE COVERSHEETS FOR THE | | | PRODUCT APPROVAL FOR ROOF HATCH. NO TECHNICAL SHEETS | | | WERE SUBMITTED. THE PRODUCT APPROVAL COVER SHEETS AND | | | TECHNICAL SHEETS SHOULD BE SUBMITTED IN THE SAME FILE. | | | 1ST ROUND COMMENT. SHEET S2 DETAIL 5 INDICATES A ROOF | | | HATCH. COMPONENTS & CLADDING. SUBMIT THE PRODUCT | | | APPROVAL FOR THE ROOF HATCH. 2020 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: (31)(A) | | | ROOF HATCHES. | | | | | | 10) COMPLIED. ROOF TOP CURB NOA: 20-0917.03 PAGE PG 4 & | | | 5. | | | | | | 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | | WORKING FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-10-20 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-10-20 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2021-10-20 15:24:56 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21091210 / NEW CONSTRUCTION | | | ADD: 1236 PALM BEACH LAKES BLVD. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: ??? | | | E-MAIL: [email protected] JESSICA LALOGGIA | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | | | | 1ST REVIEW | | | DATE: WED. OCT. 20/ 2021 | | | ACTION: DENIED | | | | | | 1) SUBMITTED PACIFICA ENGINEERING PROJECT # 610-20451 | | | AUTOZONE # 6216. PAGE 4 OF 25 IN SECTION 4.1 OF THE | | | SOILS REPORT THERE ARE 3 OPTIONS FOR THE SOILS FOUND | | | WITH PEAT. SINCE THERE IS NO CONTRACTOR ON BOARD IT IS | | | ASSUMED THAT THE DESIGNER OF RECORD IS GOING TO CHOOSE | | | WHICH METHOD OR OPTION IS TO BE USED IN THE | | | STRENGTHENING OF THE SOILS. SHEET SO INDICATES NOTE 7 | | | HELICAL PILE TESTING PLEASE CIRCLE IN THE SOILS REPORT. | | | | | | 2) AS IN THE PAST WITH AUTO ZONE ALL PRODUCT APPROVALS | | | WERE SUBMITTED HAVE THE DESIGNER OF RECORD STAMP OF | | | APPROVAL, BUT NONE OF THE SUB-SYSTEMS HAVE BEEN | | | IDENTIFIED. PLEASE IDENTIFY IN THE PRODUCT APPROVAL | | | BEFORE SUBMITTING TO DESIGNER OF RECORD AND BEFORE | | | SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS | | | WITH GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & | | | HEIGHT, SILL HEIGTH, TYPE OF GLAZING, MULLION SIZE, | | | LENGTH IF UNREINFORCED OR REINFORCED INFORMATION IF | | | REQUIRED, ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH | | | OPENING SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. | | | WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH | | | APPROVED MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND | | | SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND | | | SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING | | | USED IN THE TESTS. | | | | | | 3) ROOFING REPORTS 2 WERE ALSO SUBMITTED. ONE FOR METAL | | | ROOFING THE OTHER AN UNDERLAYMENT. THE METAL ROOF | | | REPORT FL 11241-R7 HAS 6 SUB-REPORTS WITH VARYING | | | METALS CONFIGURATIONS AND PRESSURES. THE DESIGNER OF | | | RECORD HAS A STAMP OF APPROVAL BUT HAS NOT IDENTIFIED | | | WHICH SUB-SYSTEM IS TO BE INSTALLED ON THIS JOB. GAF | | | SINGLE PLY ROOF SYSTEM FL 16739-R26 WAS SUBMITTED THE | | | DESIGNER STAMP OF APPROVAL ON THE COVER SHEET, PAGE 1 | | | OF 137 TABLE 2D STEEL DECK NEW ROOF MECHANICALLY | | | FASTENED ROOF PAGES 31-38 HIGHLIGHTED. ALSO ON PAGE 12 | | | OF 137 SYSTEM S-45 HIGHLIGHTED WITH A DESIGN PRESSURE | | | OF -45.0 *. AT THE TOP OF THE SHEET THIS IS FOR STEEL | | | OR CONCRETE DECK. YOU CAN?T HIGHLIGHT 2 SYSTEMS. PLEASE | | | PICK WHICH SUB-SYSTEM IS TO BE INSTALLED. PLEASE ALSO | | | READ WHAT THE * MEANS. SEE PAGE 2 NOTE NUMBER 9 STATES | | | THIS EXTRAPOLATION IS NOT PERMITTED FOR SYSTEMS MARKED | | | WITH AN ASTERISK * MARK. | | | | | | 4) PLEASE PROVIDE A SURVEY OF THE PROPERTY AND PROPOSED | | | BUILDING ON THE LOT AND DIMENSIONS TO EACH OF THE | | | PROPERTY LINES. SHEET C-04 SUBMITTED BUT NOT A PROPOSED | | | SURVEY. DETERMINATION OF FIRE RESISTANCE RATING | | | REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE | | | SEPARATION DISTANCE, 2020 FBC-BUILDING SECTION 602. | | | | | | 5A) SHEET C-04 SHOWS 30 PARKING SPACES 2 OF WHICH ARE | | | ACCESSIBLE PARKING SPACES. THIS DRAWING SHOWS THE | | | PARKING SPACES STRIPPED WITH A SINGLE LINE. 2020 | | | ACCESSIBILITY CODE SECTION 502.2 VEHICLE SPACES. EACH | | | PARKING SPACE MUST BE AT LEAST 12 FEET WIDE, SHALL BE | | | MARKED TO DEFINE THE WIDTH, AND SHALL HAVE AN ADJACENT | | | ACCESS AISLE COMPLYING WITH 502.3. | | | ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR | | | OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT | | | MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. | | | WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485 | | | ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL | | | PAINTING. | | | | | | 5B) 502.4 ACCESS AISLE & PARKING SPACE SAME LEVEL/ | | | 502.4, FLOOR AND GROUND SURFACES. PARKING SPACES AND | | | THE ACCESS AISLES SERVING THEM SHALL COMPLY WITH 302. | | | ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING | | | SPACES THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. | | | EXCEPTION: SLOPES NOT GREATER THAN 1:48 SHALL BE | | | PERMITTED. | | | | | | 6) THE LIFE SAFETY SHEET SHOWS SHELVING UNITS 90 INCHES | | | IN HEIGHT AND 114 INCHES IN HEIGHT. THERE IS ALSO A | | | NOTE THE MAXIMUM SHELVING UNIT HEIGHT IS 144 INCHES. | | | SHELVING UNITS THAT ARE OVER 60 INCHES IN HEIGHT | | | REQUIRE A SPERATE PERMIT AND REVIEW. 2020 W. P. B. | | | ADMINISTRATIVE CODE SECTION 105.2 (6). THE SHELVING CAN | | | BE REVIEWED UNDER THIS SET OF PLANS A SEPARATE PERMIT | | | APPLICATION AND FEES ARE REQUIRED. | | | | | | 7) PLEASE PROVIDE WHERE I CAN FIND THE STEEL FOR THE | | | TOP BOND BEAM. SHEET S1 DOES SHOW STEEL RE-INFORCEMENT | | | OVER THE LINTELS BUT NOT IN THE BOND BEAM? 107.2.1.2 | | | ADDITIONAL INFORMATION IS REQUIRED. THIS SAME SHEET | | | PROVIDES THE VERTICAL BAR SIZE AND SPACING. | | | | | | 8) SHEET S-2 SHOWS THE BAR JOIST SPACING AND REQUIRED | | | ADDITIONAL STEEL FOR RTU AND ROOF HATCH OPENINGS WITHIN | | | THE ROOF FRAMING SYSTEM. WELDED OR BOLTED CONNECTIONS | | | THIS BUILDING CONTAINS EITHER BOLTED AND OR WELDED | | | CONNECTIONS. THE CONTRACTOR IS REQUIRED TO PROVIDE WELD | | | PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT 561-805-6666. | | | | | | 9) SHEET S2 DETAIL 5 INDICATES A ROOF HATCH. COMPONENTS | | | & CLADDING. SUBMIT THE PRODUCT APPROVAL FOR THE ROOF | | | HATCH. 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: (31)(A) ROOF HATCHES. | | | | | | 10) SHEET S-2 DETAIL 3 STATES THAT THE ATTACHMENT OF | | | THE RTU TO THE ROOF TOP CURB AS SPECIFIED BY THE CURB | | | MANUFACTURER (CDI) INSTALLATION DRAWINGS. NOT FOUND IN | | | THIS PERMIT PACKAGE. THE TIE DOWN NEEDS TO BE FOR 170 | | | MPH VULT WIND ZONE/ 132 MPH VASD, 2020 FBC-M- 301.15 | | | WIND RESISTANCE. | | | MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE | | | EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO | | | RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH | | | THE FLORIDA BUILDING CODE, BUILDING. | | | FBC-B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND | | | PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT IS TO | | | BE DESIGNED FOR WIND PRESSURES COMPONENTS AND | | | ATTACHMENTS. | | | | | | LATERAL FORCE-RESISTING SYSTEM | | | FOR ALL ROOF TOP EQUIPMENT, CURBS, FANS OR A/C STANDS, | | | AND OR VENTS, DETAILED ATTACHMENT TO THE ROOF FRAMING & | | | DECK AS WELL AS FROM THE CURB OR ROOF STAND TO THE | | | EQUIPMENT ABOVE. | | | | | | 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 11) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | | WORKING FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
|
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-21 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-21 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2023-04-04 15:33:05 | ELECTRIC WORK WAS STARTED BEFORE THE REQUIRED | | | ELECTRICAL SUB PERMIT WAS APPLIED FOR AND ISSUED. A 4X | | | FEE IS NOW REQUIRED BEFORE AN ELECTRICAL SUB PERMIT CAN | | | BE ISSUED. PLEASE PROVIDE AN ACCURATE VALUE FOR THE | | | ELECTRICAL WORK PORTION OF THIS PROJECT. THE 4X FEE | | | WILL BE CALCULATED USING THIS VALUE AND WILL REQUIRE | | | PAYMENT BEFORE AN ELECTRICAL SUB PERMIT IS ISSUED. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-02-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-14 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-14 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-12 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-12 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-11-10 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-11-10 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
P |
Date |
2022-06-14 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-06-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-06-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-06-14 07:27:15 | PASSED WITH PROVISO - CONFIRM LATEST PLANS AS SUBMITTED | | | TO ENGINEERING HAVE BEEN UPLOADED TO PERMIT. | | | | | | THANKS, | | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | | STANDARDS-DETAILS | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-03-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-03-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-07 10:06:32 | A FORMAL ENGINEERING SUBMITTAL IS REQUIRED AFTER FORMAL | | | SITE PLAN APPROVAL. | | | | | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | | STANDARDS-DETAILS |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-01-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-01-31 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-31 09:12:14 | A FORMAL ENGINEERING SUBMITTAL IS REQUIRED AFTER FORMAL | | | SITE PLAN APPROVAL. | | | | | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | | STANDARDS-DETAILS | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2021-12-20 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-12-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-12-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-20 13:20:16 | PLEASE ADDRESS ZONING COMMENTS. ADDITIONALLY, A FORMAL | | | ENGINEERING SUBMITTAL IS REQUIRED AFTER FORMAL SITE | | | PLAN APPROVAL. | | | | | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | | STANDARDS-DETAILS | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-10-15 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-10-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-15 09:04:26 | PLEASE ADDRESS ZONING COMMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-12-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2021-12-10 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-09-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2021-09-30 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2021-09-30 08:52:28 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-21 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-21 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-06-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-17 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-13 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-04-06 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-03-02 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-02-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-02-14 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-21 |
Time |
06:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-13 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-08 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-11-10 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-28 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-06-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-08 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-04-07 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2022-06-08 15:39:22 | RECEIPT MU-2022-018588 - $61,695.49 PAID | | 2022-04-07 10:52:26 | 4/7/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-10-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-10-20 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-10-20 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2021-10-20 13:23:15 | IMPACT FEES - DIGITAL SUBMITTALS: | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected]. | | | PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300 | | | N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-25 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-25 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-08 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-07 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-02-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-02-07 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-02-07 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2022-02-07 12:01:47 | 3RD REVIEW FBC-2020 PLUMBING | | | PERMIT- 21091210 | | | 2/7/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENT #3A FROM THE 1ST | | | REVIEW LISTED BELOW IS FAILED AGAIN. THE CORRECTED PLAN | | | DOES NOT CLEARLY SHOW THE CLEAR SPACE DIAGRAMS AND | | | DIMENSIONS FOR THE WATER CLOSETS. REFER TO SECTION | | | 604.3.1 FBC ACC- 604.3.1 SIZE. | | | CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES | | | MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND | | | 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR | | | WALL. THE CORRECTED PLAN SHOWS THE DIAGRAMS IN THE | | | WRONG LOCATIONS AND THE 60-INCHES CLEAR MEASUREMENTS | | | FROM THE SIDE WALLS TO THE SINKS ARE NOT SHOWN. | | | | | | IST REVIEW COMMENT. | | | 3 A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS | | | FOR THE WATER CLOSETS- SECTION 604.3 FBC ACC. | | | | | | NEW COMMENT. | | | 1) SHEET A4: IT APPEARS PAINTED GYPSUM WILL BE | | | INSTALLED ON THE WALLS SURROUNDING THE WATER CLOSETS | | | AND MOP SINK. REFER TO SECTION 310.3 FBC P AND SECTION | | | 1210.2.2 FBC B- "WALLS AND PARTITIONS WITHIN 2 FEET OF | | | SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT | | | LESS THAN 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR | | | STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS | | | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE." PLEASE PROVIDE APPROVED MATERIALS SUCH AS | | | TILE OR FRP BOARD. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-29 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-29 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2021-12-29 16:09:37 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21091210 | | | 10/28/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN | | | CAP LETTERS FOR FURTHER CLARIFICATIONS. | | | | | | 3) FAILED ITEMS A & B. A4 DETAIL 7 RESTROOM PLAN: | | | PLEASE CORRECT THE DETAIL ACCORDING TO THE FOLLOWING | | | FBC ACC CODE SECTIONS AND NOTE THAT EXACT DETAILS AND | | | DIMENSIONS ARE REQUIRED: | | | A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE WATER CLOSETS- SECTION 604.3. THE PLAN SHOWS 30X48 | | | INCH CLEAR FLOOR SPACES AT THE WATER CLOSETS- 60X56 | | | SPACES REQUIRED. | | | B) FAILED. CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS | | | FOR THE LAVATORIES- SECTION 606.2. THE 30X48 INCH CLEAR | | | FLOOR SPACE FORWARD APPROACH DIAGRAMS SHALL EXTEND INTO | | | THE KNEE AND TOE CLEARANCE AREAS. | | | | | | 4) FAILED ITEMS B, E, F, G, & H. A4 DETAIL 6 | | | ELEVATIONS: PLEASE CORRECT THE DETAIL ACCORDING TO THE | | | FOLLOWING FBC ACC CODE SECTIONS AND NOTE THAT EXACT | | | DETAILS AND DIMENSIONS ARE REQUIRED: | | | B) FAILED. LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF | | | GRAB BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | | FIGURES 604.5.1 & 604.5.2. GRAB BARS HEIGHTS APPEAR TO | | | BE SHOWN TO THE CENTERS OF THE GRAB BARS AND NOT TO THE | | | TOPS OF THE GRIPPING SURFACES- SEC. 609.4. | | | E) FAILED. CENTERLINES OF THE TOILET PAPER DISPENSERS | | | MEASURED FROM THE FRONTS OF THE WATER CLOSETS- SECTION | | | AND FIGURE 604.7. THE DISPENSERS SHALL BE 7 INCHES | | | MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER | | | CLOSETS MEASURED TO THE CENTERLINES OF THE DISPENSERS. | | | F) FAILED. KNEE AND TOE CLEARANCES FOR THE LAVATORIES- | | | SECTION 606.2, AND FIGURES 306.2 & 306.3. PLEASE | | | PROVIDE THE CLEARANCES PER THE LISTED CODE SECTIONS AND | | | FIGURES. | | | G) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE ACCESSIBLE DRINKING FOUNTAIN- SECTION 602.2 & 305. | | | FIGURES 306.2 & 306.3. THE 30X48 INCH CLEAR FLOOR SPACE | | | FORWARD APPROACH DIAGRAM SHALL EXTEND INTO THE KNEE AND | | | TOE CLEARANCE AREAS. | | | H) FAILED. KNEE AND TOE CLEARANCES FOR THE DRINKING | | | FOUNTAIN- SECTION 606.2 & FIGURES 306.2 & 306.3. PLEASE | | | PROVIDE THE CLEARANCES PER THE LISTED CODE SECTIONS AND | | | FIGURES. | | | | | | 6) FAILED. P1: PROVIDE A COMPLETE EQUIPMENT SCHEDULE | | | FOR THE NEW WATER HEATER THAT INDICATES THE MAKE AND | | | MODEL, GALLON SIZE AND EFFICIENCY RATING- TABLE C404.2 | | | FBC EC. BASED ON THE MANUFACTURER?S INSTALLATION | | | INSTRUCTIONS THE BOSCH ES4 WATER HEATER SPECIFIED IS A | | | POINT OF USE WATER HEATER DESIGNED TO BE INSTALLED | | | UNDER A SINK. THE PLAN SHOWS THE HEATER BEING USED AS A | | | CENTRAL HOT WATER SOURCE. | | | | | | 13) FAILED. P1: THE 1/2-INCH HOT WATER SUPPLY PIPING TO | | | THE PUBLIC LAVATORIES IS EXCEEDING THE 2 FT. MAXIMUM | | | ALLOWABLE LENGTHS PER TABLE C404.5.1 FBC EC. THE 3M | | | HEAT TRACE SYSTEM SPECIFICATION INDICATE THE CABLES | | | MUST BE POWERED BY A 30 AMP GROUND FAULT CIRCUIT | | | HOWEVER THE ELECTRICAL PLAN DOES NOT SHOW THE CABLES ON | | | THE POWER. | | | | | | NEW COMMENT. | | | | | | 1) SHEET A4: SHOW THE HEIGHTS OF THE MIRRORS FROM THE | | | FINISHED FLOORS TO THE REFLECTIVE SURFACES- SECTION | | | 603.3 FBC ACC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-28 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-28 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2021-10-28 10:54:32 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21091210 | | | 10/28/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLAN SHEET P-1 IS MISLABELED AS M-1, PLEASE CORRECT- | | | SECTION 107.2.1 WPB. | | | | | | 2) SHEET A0: THE PLANS SHALL BE DESIGNED IN ACCORDANCE | | | WITH THE FBC- 2020 7TH EDITION ACCESSIBILITY CODE. | | | PLEASE ADD THE CODE TO THE LIST UNDER BUILDING CODE | | | ANALYSIS. | | | | | | 3) A4 DETAIL 7 RESTROOM PLAN: PLEASE CORRECT THE DETAIL | | | ACCORDING TO THE FOLLOWING FBC ACC CODE SECTIONS AND | | | NOTE THAT EXACT DETAILS AND DIMENSIONS ARE REQUIRED: | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSETS- SECTION 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE | | | LAVATORIES- SECTION 606.2. | | | | | | 4) A4 DETAIL 6 ELEVATIONS: PLEASE CORRECT THE DETAIL | | | ACCORDING TO THE FOLLOWING FBC ACC CODE SECTIONS AND | | | NOTE THAT EXACT DETAILS AND DIMENSIONS ARE REQUIRED: | | | A) HEIGHTS OF THE LAVATORY SINK RIMS OR COUNTER | | | SURFACES FROM THE FINISHED FLOORS- SECTION 606.3. | | | B) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | | FIGURES 604.5.1 & 604.5.2. | | | C) PLEASE REMOVE THE VERTICAL GRAB BARS- THEY ARE NOT | | | REQUIRED AND IN CONFLICT WITH SECTION 609.4- GRABS | | | SHALL BE INSTALLED IN A HORIZONTAL POSITION. | | | D) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS - | | | SECTION 604.6. | | | E) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.7. | | | F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 606.2, AND FIGURES 306.2 & 306.3. | | | G) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | ACCESSIBLE DRINKING FOUNTAIN- SECTION 602.2 & 305. | | | FIGURES 306.2 & 306.3. | | | H) KNEE AND TOE CLEARANCES FOR THE DRINKING FOUNTAIN- | | | SECTION 606.2 & FIGURES 306.2 & 306.3. | | | I) SPOUT OUTLET HEIGHT OF THE DRINKING FOUNTAIN FOR | | | STANDING PERSONS- SECTION 602.7. | | | | | | 5) SHEET A6: PLEASE PROVIDE A SCUPPER DETAIL IN | | | ACCORDANCE WITH SECTION 1503.4.2.1 FBC B. | | | | | | 6) P1: PROVIDE A COMPLETE EQUIPMENT SCHEDULE FOR THE | | | NEW WATER HEATER THAT INDICATES THE MAKE AND MODEL, | | | GALLON SIZE AND EFFICIENCY RATING- TABLE C404.2 FBC EC. | | | | | | 7) P1: PLEASE ADD THE HYDRANT TO THE FIXTURE SCHEDULE- | | | SECTION 424.6 FBC P. | | | | | | 8) P1 WATER RISER: SHOW THE LOCATIONS OF REQUIRED WATER | | | HAMMER ARRESTORS FOR THE FLUSH VALVES- SECTION 604.9 | | | FBC P. | | | | | | 9) P1 WASTE/VENT RISER: SHOW TWO FIXTURE TRAPS AT THE | | | DRINKING FOUNTAIN- SECTION 1002.1 FBC P. | | | | | | 10) P1: INDICATE HOW TEMPERED WATER WILL BE PROVIDED TO | | | THE LAVATORIES- SECTION 419.5 FBC P. PLEASE NOTE IF | | | MIXING VALVES ARE PROVIDED, THEY SHALL BE IN ASSE 1070 | | | APPROVED- SECTION 607.1.2 FBC P. | | | | | | 11) P1: PLEASE PROVIDE THE PEX PIPE SPECIFICATIONS AS | | | INDICATED- TABLE 605.4 FBC P. | | | | | | 12) P1: MINIMUM 1-INCH THICK INSULATION IS REQUIRED FOR | | | THE HOT WATER PIPING- TABLE C403.2.10 FBC EC. | | | | | | 13) P1: THE 1/2-INCH HOT WATER SUPPLY PIPING TO THE | | | PUBLIC LAVATORIES IS EXCEEDING THE 2 FT. MAXIMUM | | | ALLOWABLE LENGTHS PER TABLE C404.5.1 FBC EC. | | | | | | 14) A1, A4, & P1: PLEASE SHOW THE DRINKING FOUNTAIN | | | GUARD RAILS CONSISTENTLY ON ALL SHEETS- SECTION 307.2 | | | FBC ACC. | | | | | | 15) A0: PLEASE NOTE THAT THE POTABLE WATER SERVICE | | | BACKFLOW PREVENTER AND THE IRRIGATION SYSTEM SHALL BE | | | DONE UNDER SEPARATE PERMIT- SECTION 105.1 & 107.1 WPB. | | | PLEASE PLACE A NOTE ON THE PLAN ACCORDINGLY. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | |
|
|
| Review Stop |
P-IRRIGATE |
IRRIGATION REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-29 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-29 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2021-12-29 16:11:19 | THE IRRIGATION SYSTEM SHALL BE INSTALLED UNDER A | | | SEPARATE PERMIT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-01 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-01 09:58:21 | ROOFING PRODUCT APPROVALS PASSED UNDER BUILDING REVIEW. | | | JW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-12-14 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-14 13:37:08 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- ROOFING/BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21091210 / NEW CONSTRUCTION | | | ADD: 1236 PALM BEACH LAKES BLVD. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: ??? | | | E-MAIL: [email protected] JESSICA LALOGGIA | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | | | | 1ST REVIEW | | | DATE: WED. OCT. 20/ 2021 | | | ACTION: DENIED | | | | | | 1) A) COMPLIED. THE METAL ROOF REPORT FL 11241-R7 HAS 6 | | | SUB-REPORTS WITH VARYING METALS CONFIGURATIONS AND | | | PRESSURES. | | | | | | 1B) 2ND REQUEST. ROOFING REPORT FL16739-R26 ONLY HAS | | | THE FIRST 2 SHEETS OF THE REPORT. | | | 1ST ROUND COMMENTS. GAF SINGLE PLY ROOF SYSTEM FL | | | 16739-R26 WAS SUBMITTED THE DESIGNER STAMP OF APPROVAL | | | ON THE COVER SHEET, PAGE 1 OF 137, OR SHEET 8 OF 144 | | | HIGHLIGHTED TABLE 2D STEEL DECK NEW ROOF MECHANICALLY | | | FASTENED ROOF PAGES 31-38 OF REPORT IS HIGHLIGHTED. | | | PAGE 31 OF 137 STARTS THE SUB-SYSTEMS TABLE 2 D FOR | | | MECHANICALLY FASTEN ROOF SYSTEMS THROUGH PAGE 38 OF 137 | | | PAGES, NO SUB-SYSTEM IS HIGHLIGHTED. | | | ALSO | | | ALSO ON PAGE 12 OF 137 SYSTEM S-45 HIGHLIGHTED WITH A | | | DESIGN PRESSURE OF -45.0 *. AT THE TOP OF THE SHEET | | | THIS IS FOR STEEL OR CONCRETE DECK. YOU CAN?T HIGHLIGHT | | | 2 SYSTEMS. PLEASE PICK WHICH SUB-SYSTEM IS TO BE | | | INSTALLED. PLEASE ALSO READ WHAT THE * MEANS. SEE PAGE | | | 2 NOTE NUMBER 9 STATES THIS EXTRAPOLATION IS NOT | | | PERMITTED FOR SYSTEMS MARKED WITH AN ASTERISK * MARK. | | | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | | WORKING FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-10-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-10-20 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-10-20 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2021-10-20 15:23:45 | ROOFING REPORTS 2 WERE ALSO SUBMITTED. ONE FOR METAL | | | ROOFING THE OTHER AN UNDERLAYMENT. THE METAL ROOF | | | REPORT FL 11241-R7 HAS 6 SUB-REPORTS WITH VARYING | | | METALS CONFIGURATIONS AND PRESSURES. THE DESIGNER OF | | | RECORD HAS A STAMP OF APPROVAL BUT HAS NOT IDENTIFIED | | | WHICH SUB-SYSTEM IS TO BE INSTALLED ON THIS JOB. GAF | | | SINGLE PLY ROOF SYSTEM FL 16739-R26 WAS SUBMITTED THE | | | DESIGNER STAMP OF APPROVAL ON THE COVER SHEET, PAGE 1 | | | OF 137 TABLE 2D STEEL DECK NEW ROOF MECHANICALLY | | | FASTENED ROOF PAGES 31-38 HIGHLIGHTED. ALSO ON PAGE 12 | | | OF 137 SYSTEM S-45 HIGHLIGHTED WITH A DESIGN PRESSURE | | | OF -45.0 *. AT THE TOP OF THE SHEET THIS IS FOR STEEL | | | OR CONCRETE DECK. YOU CAN?T HIGHLIGHT 2 SYSTEMS. PLEASE | | | PICK WHICH SUB-SYSTEM IS TO BE INSTALLED. PLEASE ALSO | | | READ WHAT THE * MEANS. SEE PAGE 2 NOTE NUMBER 9 STATES | | | THIS EXTRAPOLATION IS NOT PERMITTED FOR SYSTEMS MARKED | | | WITH AN ASTERISK * MARK. | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | | WORKING FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-21 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-21 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
F |
Date |
2022-06-17 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-17 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-17 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2022-06-17 13:35:42 | SIGNATURE REVIEW FAILED | | | | | | 1) IT APPEARS PLANS LABELED A4,E2,E5 AND E6 ARE NOT | | | SIGNED AS REQUIRED. PLEASE FOLLOW THE INSTRUCTIONS | | | BELOW TO CORRECT THESE ISSUES. | | | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | | SIGNED. | | | | | | UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN TO THE | | | SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF APPLICABLE) | | | AND COMPLETE THE UPLOAD TASK IN PROJECTDOX.. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] WITH ANY QUESTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-08 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-08 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-02-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-14 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-14 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-12 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-12 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-11-10 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-11-10 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-04-07 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-04-05 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-02-08 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2022-02-08 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-02-08 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2022-02-08 15:58:56 | 2/8/22- FAILED. DOES NOT MATCH APPROVED SITE PLAN. | | | SUBMIT A MINOR AMENDMENT. | | | | | | ANGELLA VANN | | | [email protected] | | | 561-822-1441 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
av |
Date |
2021-12-29 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-12-29 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2021-12-29 15:05:31 | 12/29/21- FAILED. PLEASE COMPLETE THE INFORMAL SITE | | | PLAN REVIEW PROCESS BEFORE ZONING CAN APPROVE A | | | BUILDING PERMIT. | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-10-06 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-10-06 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-10-06 |
Time |
|
Sent To |
I |
|
| Notes |
| 2021-10-06 09:29:17 | ISPR 21-07 - PROJECT NUMBER Z21050011 HAS NOT RECEIVED | | | FINAL PROJECT APPROVAL. | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | [email protected] |
|
|