Plan Review Details - Permit 21091077
Plan Review Stops For Permit 21091077
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-02-15 Cont ID  
Sent By cpuell Date 2022-02-15 Time 09:26 Rev Time 0.00
Received By cpuell Date 2022-02-15 Time 09:26 Sent To  
Notes
2022-02-15 09:27:41EAST HALF ADDRESS READDRESSED TO 2730 LAKE AVE

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-12-01 Cont ID  
Sent By cpuell Date 2021-12-01 Time 12:02 Rev Time 0.00
Received By cpuell Date 2021-12-01 Time 12:02 Sent To  
Notes
2021-12-01 12:03:05WHICH BUILDING IS THE WORK TO BE DONE, EAST OR WEST?
 THE EAST BUILDING HAS A HALF ADDRESS WHICH WILL NEED TO
 BE READDRESSED. PLEASE HAVE THE OWNER CONTACT
 [email protected] OR CALL 561-805-6659 TO READDRESS THE
 HALF ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-06-24 Cont ID  
Sent By shill Date 2023-06-24 Time 08:00 Rev Time 0.00
Received By shill Date 2023-06-24 Time 08:00 Sent To  
Notes
2023-06-24 08:00:19NO CHANGE IN PLANS - PASSED BY DB (RESTAMP)
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-06-16 Cont ID  
Sent By dbattles Date 2023-06-16 Time 09:37 Rev Time 0.00
Received By dbattles Date 2023-06-16 Time 09:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-06-03 Cont ID  
Sent By dbattles Date 2022-06-03 Time 10:20 Rev Time 0.00
Received By dbattles Date 2022-06-03 Time 09:25 Sent To  
Notes
2022-06-03 10:21:32BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 21091077
 REVIEWED: JUNE 3, 2022
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1. THE ROUGH-FRAMED OPENING SHALL BE NOT LESS THAN 22
 INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE
 LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE
 LOCATION. WHERE LOCATED IN A WALL, THE OPENING SHALL BE
 NOT LESS THAN 22 INCHES WIDE BY 30 INCHES HIGH (559 MM
 WIDE BY 762 MM HIGH). WHERE THE ACCESS IS LOCATED IN A
 CEILING, MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC
 SPACE SHALL BE 30 INCHES (762 MM) AT SOME POINT ABOVE
 THE ACCESS MEASURED VERTICALLY FROM THE BOTTOM OF
 CEILING FRAMING MEMBERS. SEE SECTION M1305.1.3 FOR
 ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS
 LOCATED IN ATTICS.
 - PLEASE SHOW ATTIC ACCESS LOCATION ON PLANS
  
 2. 311.3 FBC[R] FLOORS AND LANDINGS AT EXTERIOR DOORS.
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED
 IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR
 LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (2 PERCENT).
 - PROVIDE LANDING AT EXTERIOR SIDE OF DOOR IF GREATER
 THAN 2 RISERS PROVIDED.
  
 3. 318 FBC[R] INDICATE THE MEANS OF TERMITE PROTECTION
 PROPOSED AND REFERENCE SECTION R308 FOR STANDARDS.
  
 4. 401.2 FBC[RE] PROVIDE ENERGY CALCULATIONS TO MEET
 REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. CHOOSE
 METHOD IN R401.2 AND SUPPLY DOCUMENTATION.
 - PLEASE SUPPLY ENERGY CALCULATIONS FOR THE NEWLY
 ENCLOSED SPACE AND NEWLY INSULATED ATTIC.
 5. 806.2 FBC[R] THE MINIMUM NET FREE VENTILATING AREA
 SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE.
 - SEE EXECPTIONS IN SECTION 806.2 TO ALLOW 1/300.
  
 6. ASCE 7-10 26.7.1 WIND EXPOSURE CATEGORY.
 - PLEASE PROVIDE PROJECT DATA, OR INDICATE WHERE THIS
 IS ON THE PLANS.
 OCCUPANCY = R3
 BASIC WIND SPEED=170
 RISK CATEGORY = II
 EXPOSURE CATEGORY = B
 BUILDING CLASSIFICATION = ENCLOSED
 MEAN BLDG. HGT. = 0?-0? ? THIS WILL BE THE HEIGHT
 MEASURED FROM THE GROUND TO IN BETWEEN EAVE AND ROOF
 PEAK.
 WIND SPEED V ULT = 170
 WIND SPEED V ASD = 132
  
 7. 301.2.1 FBC[R] PROVIDE DESIGN PRESSURES NEEDED FOR
 WINDOWAND DOOR
  
 8. R302.1 EXTERIOR WALLS
 - PLEASE PROVIDE THE DISTANCE OF ENCLOSED SPACE TO THE
 PROPERTY LINE. THIS CAN BE ON THE SURVEY THAT ZONING
 WANTS AS WELL.
  
 NOTES:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS.
 FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE
 REQUIRED.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2023-07-10 Cont ID  
Sent By mpeterso Date 2023-07-10 Time 08:49 Rev Time 0.00
Received By mpeterso Date 2023-07-10 Time 08:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-06-22 Cont ID  
Sent By mpeterso Date 2023-06-22 Time 10:38 Rev Time 0.00
Received By mpeterso Date 2023-06-22 Time 09:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-05-24 Cont ID  
Sent By mpeterso Date 2023-05-24 Time 12:39 Rev Time 0.00
Received By mpeterso Date 2023-05-24 Time 12:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-04-13 Cont ID  
Sent By mpeterso Date 2022-04-13 Time 11:17 Rev Time 0.00
Received By mpeterso Date 2022-04-13 Time 11:17 Sent To  
Notes
2022-04-13 11:19:06ELECTRICAL REVIEW FAILED
 1) VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR,
 OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR OR
 PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3
 2) PLEASE DETAIL INTERIOR LOCATIONS FOR ELECTRIC
 PANELS. FBC 107.2
 3) PLEASE PROVIDE SITE PLAN DETAILING ALL OUTSIDE
 DISCONNECTS AND METERS. FBC 107.2
 4) PLEASE DETAIL ALL OUTDOOR RECEPTACLES AS PER NEC
 210.50 (E), 210.63 AND 210.64
 5) PLEASE DETAIL ALL OUTDOOR RECEPTACLES AS PER NEC
 210.50 (E), 210.63 AND 210.64
 6) PLEASE PROVIDE AN ACCURATE SCOPE OF WORK. FBC107.2
 7) PLEASE DETAIL SMOKE ALARMS AS REQUIRED. FBC RE 2020,
 7TH EDITION
 8) PLEASE DETAIL ALL RECEPTACLES REQUIRED AS PER NEC
 250.50
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-03 Time 11:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-29 Cont ID  
Sent By cmontell Date 2023-06-29 Time 13:36 Rev Time 0.00
Received By cmontell Date 2023-06-29 Time 13:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-31 Cont ID  
Sent By rmcdouga Date 2023-06-20 Time 11:06 Rev Time 0.00
Received By cmontell Date 2023-05-31 Time 13:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-03 Cont ID  
Sent By dbattles Date 2022-06-03 Time 10:21 Rev Time 0.00
Received By dbattles Date 2022-03-28 Time 09:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2023-07-17 Cont ID  
Sent By cmontell Date 2023-07-17 Time 13:17 Rev Time 0.00
Received By cmontell Date 2023-07-17 Time 13:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-06-29 Cont ID  
Sent By cmontell Date 2023-06-29 Time 13:35 Rev Time 0.00
Received By cmontell Date 2023-06-29 Time 13:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By cmontell Date 2023-05-31 Time 13:19 Rev Time 0.00
Received By cmontell Date 2023-05-31 Time 13:19 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-04-06 Cont ID  
Sent By medwards Date 2022-04-06 Time 06:14 Rev Time 0.00
Received By medwards Date 2022-04-06 Time 06:14 Sent To  
Notes
2022-04-06 06:14:481ST REVIEW FMC
 PERMIT: 21091077
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THIS PROJECT WILL REQUIRE A SEPARATE MECHANICAL
 PERMIT FROM A LICENSED MECHANICAL CONTRACTOR.
  
 2) PLEASE PROVIDE THE ENERGY CALCULATIONS. FEC R402
  
 3) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC R403.7
  
 4) PLEASE PROVIDE THE CONDENSATE DRAINAGE LOCATIONS.
 FRC M1411.3
  
 5) THE MECHANICAL DRAWING SHOULD HAVE THE DESIGNERS
 PRINTED NAME AND SIGNATURE IN THE TITLE BLOCK.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-06-22 Cont ID  
Sent By rwbrown Date 2023-06-22 Time 12:40 Rev Time 0.00
Received By rwbrown Date 2023-06-22 Time 12:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-03-30 Cont ID  
Sent By rwbrown Date 2022-03-30 Time 12:56 Rev Time 0.00
Received By rwbrown Date 2022-03-30 Time 12:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2023-06-20 Cont ID  
Sent By rmcdouga Date 2023-06-20 Time 14:59 Rev Time 0.00
Received By rmcdouga Date 2023-06-20 Time 14:59 Sent To  
Notes
2023-06-20 15:38:25THE SIGNED AND SEALED PLANS SHOW A WASHER AND DRYER
 THAT IS NOT SHOWN ON THE PLUMBING OR MECHANICAL
 DRAWINGS. THE SIGNED AND SEALED DRAWINGS ARE REQUIRED
 TO BE EXACTLY THE SAME AS THE ONES THAT ARE APPROVED BY
 THE REVIEWER.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-06-20 Cont ID  
Sent By cmontell Date 2023-05-31 Time 13:20 Rev Time 0.00
Received By rmcdouga Date 2023-06-20 Time 11:06 Sent To I
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-06-03 Cont ID  
Sent By dbattles Date 2022-06-03 Time 10:21 Rev Time 0.00
Received By dbattles Date 2022-06-03 Time 09:25 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2023-07-11 Cont ID  
Sent By vbroglia Date 2023-07-11 Time 13:06 Rev Time 0.00
Received By vbroglia Date 2023-07-11 Time 13:06 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2023-06-27 Cont ID  
Sent By vbroglia Date 2023-06-27 Time 10:18 Rev Time 0.00
Received By vbroglia Date 2023-06-27 Time 10:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-05-18 Cont ID  
Sent By vbroglia Date 2023-05-18 Time 16:27 Rev Time 0.00
Received By vbroglia Date 2023-05-18 Time 16:27 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-04-05 Cont ID  
Sent By vbroglia Date 2022-04-05 Time 15:55 Rev Time 0.00
Received By vbroglia Date 2022-04-05 Time 15:55 Sent To  
Notes
2022-04-05 15:57:364/5/2022 FAILED
  
 SEPERATE PERMIT IS REQUIRED FOR MECHANICAL EQUIPMENT
  
 PLEASE PROVIDE THE HIEGHT IN ELEVATIONS MEASUERING FROM
 FINISH GRADE TO THE MEAN OF THE NEW ROOF
 PLEASE PROVIDE A SURVEY OR SITEPLAN FOR EXPANDING WALL
 WITH SETBACKS FROM PROPERTY LINE
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  