Plan Review Details - Permit 21091020
Plan Review Stops For Permit 21091020
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2021-11-12 Cont ID  
Sent By cpuell Date 2021-11-12 Time 10:39 Rev Time 0.00
Received By cpuell Date 2021-11-12 Time 10:39 Sent To  
Notes
2021-11-12 10:39:52APPLICANT TO APPLY FOR A SEPARATE PERMIT FOR THE
 GARAGE, WILL REVIEW ADDRESSING ISSUES UNDER THAT
 PERMIT.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-11-04 Cont ID  
Sent By cpuell Date 2021-11-04 Time 14:51 Rev Time 0.00
Received By cpuell Date 2021-11-04 Time 14:51 Sent To  
Notes
2021-11-04 14:51:53GARAGE WAS CONVERTED INTO LIVABLE SPACE AND CONFIRMED
 BY THE MOST RECENT REAL ESTATE LISTING, SHOWING A
 SHOWER, KITCHEN IN THE GARAGE. THIS ILLEGAL CONVERSION
 HAS BEEN FLAGGED ON THE PROPERTY AND YOU WILL NEED TO
 APPLY FOR A PERMIT FOR THE GARAGE CONVERSION. PLEASE
 COORDINATE WITH [email protected] OR CALL 561-805-6659 FOR
 THE LIVABLE SPACE TO BE GIVEN AN ADDRESS. ALL ACCESSORY
 RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER HABITABLE
 STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY ADDRESS
 NUMBER PER CITY'S ADDRESSING POLICY

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-09-22 Cont ID  
Sent By cpuell Date 2021-09-22 Time 16:27 Rev Time 0.00
Received By cpuell Date 2021-09-22 Time 16:27 Sent To  
Notes
2021-09-22 16:31:28GARAGE WAS CONVERTED INTO LIVABLE SPACE AND CONFIRMED
 BY THE MOST RECENT REAL ESTATE LISTING, SHOWING A
 SHOWER, KITCHEN IN THE GARAGE. THIS ILLEGAL CONVERSION
 HAS BEEN FLAGGED ON THE PROPERTY AND YOU WILL NEED TO
 APPLY FOR A PERMIT FOR THE GARAGE CONVERSION. PLEASE
 COORDINATE WITH [email protected] OR CALL 561-805-6659 FOR
 THE LIVABLE SPACE TO BE GIVEN AN ADDRESS. ALL ACCESSORY
 RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER HABITABLE
 STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY ADDRESS
 NUMBER PER CITY'S ADDRESSING POLICY

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-11-19 Cont ID  
Sent By jgomez Date 2021-11-19 Time 17:17 Rev Time 0.00
Received By jgomez Date 2021-11-19 Time 16:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-11-09 Cont ID  
Sent By jgomez Date 2021-11-09 Time 17:45 Rev Time 0.00
Received By jgomez Date 2021-11-09 Time 16:06 Sent To  
Notes
2021-11-09 17:53:09RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21091020
  
 NOTE;
 THIS COMMENTS APPLY TO MAIN HOUSE ONLY. CONTRACTOR WILL
 SUBMIT PLANS UNDER A SEPARATE PERMIT APPLICATION FOR
 THE GARAGE CONVERSION.
  
  
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT
 NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW
  
  
 1- COVER SHEET (CVR):
  
 A) OK
  
 ORIGINAL COMMENT:
 B) REVISE COMPONENTS AND CLADDING INFORMATION TO MATCH
 ACTUAL CONDITIONS. MEAN ROOF HEIGHT, ROOF GEOMETRIC AND
 ROOF SLOPE ARE INCORRECT. THIS IS A TWO STORY BUILDING.
 REVISE AS REQUIRED TO MATCH ACTUAL BUILDING
 DESCRIPTION. SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 BUILDING MEAN ROOF HEIGHT IS INCORRECT AGAIN. THIS IS A
 TWO STORY HOUSE. IT CAN NOT BE 16 FEET. REVISE AS
 REQUIRED.
  
 ORIGINAL COMMENT:
 C) AREA CALCULATIONS ARE INCORRECT. PROVIDE BUILDING
 DIMENSIONS AND REVISE AREA CALCULATIONS AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. AREA CALCULATIONS ARE
 INCORRECT. IT LOOKS LIKE ENGINEER OF RECORD IS TAKING
 THE AREA CALCULATIONS FROM PALM BEACH COUNTY PROPERTY
 APPRAISER. THE FOOTPRINT SHOWN ON SHEET A-1 AND THE
 FOOTPRINT SHOWN ON THE PALM BEACH COUNTY PROPERTY
 APPRAISER WEBSITE DON'T MATCH. THEREFORE, CALCULATIONS
 ARE INCORRECT. REVISE AS REQUIRED. PROVIDE THE ACTUAL
 CALCULATIONS OF THE BUILDING SHOWN ON SHEET A-1.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-18 Cont ID  
Sent By JGOMEZ Date 2021-10-18 Time 13:10 Rev Time 0.00
Received By jgomez Date 2021-10-18 Time 11:25 Sent To  
Notes
2021-10-05 13:13:12NOTE: GARAGE CONVERTED TO LIVABLE SPACE WITHOUT
 PERMITS. NEED PLANS.
 10/05/21 TALKED TO SCOTT HARDIN & CHARLES SOFGE
 (OWNERS). CHANGED CONTRACTOR TO T.B.D. CONTRACTOR WILL
 SUBMIT PERMIT APPLICATION. ALSO, THEY AGREED TO SUBMIT
 SEPARATE PERMIT APPLICATION FOR THE GARAGE CONVERSION.
 JG.
  
 NOTE: MAIN HOUSE PERMIT WILL BE CONTINGENT ON SUBMITTAL
 OF PERMIT APPLICATION AND PLANS FOR THE GARAGE
 CONVERSION. THIS WAS DISCUSSED WITH OWNERS. JG.
  
 RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21091020
  
 NOTE:
 SEC. 603 AND SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 1- COVER SHEET (CVR):
 A) BASED ON AERIAL VIEW OF THE PROPERTY APPRAISER
 WEBSITE THE FACILITY DESCRIPTION SPECIFIED ON COVER
 SHEET IS INCORRECT. THERE IS NOT HIP ROOF AND THE ROOF
 MATERIAL IS NOT ASPHALT SHINGLES. REVISE AS REQUIRED TO
 MATCH ACTUAL BUILDING DESCRIPTION. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 B) REVISE COMPONENTS AND CLADDING INFORMATION TO MATCH
 ACTUAL CONDITIONS. ROOF HEIGHT, ROOF GEOMETRIC AND ROOF
 SLOPE ARE INCORRECT. THIS IS A TWO STORY BUILDING.
 REVISE AS REQUIRED TO MATCH ACTUAL BUILDING
 DESCRIPTION. SEC. 107.2.1 CITY AMENDMENTS.
  
 C) AREA CALCULATIONS ARE INCORRECT. PROVIDE BUILDING
 DIMENSIONS AND REVISE AREA CALCULATIONS AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-11-09 Cont ID  
Sent By jleahy Date 2021-11-09 Time 14:56 Rev Time 0.00
Received By jleahy Date 2021-11-09 Time 14:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-10-13 Cont ID  
Sent By jleahy Date 2021-10-13 Time 12:19 Rev Time 0.00
Received By jleahy Date 2021-10-13 Time 12:08 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2021-10-18 Cont ID  
Sent By jgomez Date 2021-10-18 Time 13:31 Rev Time 0.00
Received By jgomez Date 2021-10-18 Time 13:31 Sent To  
Notes
2021-10-18 13:32:37MAIN HOUSE ONLY. INTERIOR WORK ONLY. IT DOESN'T AFFECT
 THE EXTERIOR OF THE BUILDING. JG.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2021-12-03 Cont ID  
Sent By jgomez Date 2021-12-03 Time 17:21 Rev Time 0.00
Received By jgomez Date 2021-12-03 Time 17:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2021-12-02 Cont ID  
Sent By jgomez Date 2021-12-02 Time 13:47 Rev Time 0.00
Received By jgomez Date 2021-12-02 Time 13:44 Sent To I
Notes
2021-12-02 13:45:5412/02/21 MET CHARLES SOFGE. HE BROUGHT ORIGINAL A-1
 DWG. JG.
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-11-30 Cont ID  
Sent By jgomez Date 2021-11-30 Time 16:03 Rev Time 0.00
Received By jgomez Date 2021-11-30 Time 15:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-11-30 Cont ID  
Sent By jgomez Date 2021-11-30 Time 10:05 Rev Time 0.00
Received By jgomez Date 2021-11-30 Time 09:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-11-19 Cont ID  
Sent By jgomez Date 2021-11-19 Time 17:38 Rev Time 0.00
Received By jgomez Date 2021-11-17 Time 16:46 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-09 Cont ID  
Sent By jgomez Date 2021-11-09 Time 18:01 Rev Time 0.00
Received By jgomez Date 2021-11-03 Time 08:49 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-18 Cont ID  
Sent By jgomez Date 2021-10-18 Time 13:33 Rev Time 0.00
Received By jgomez Date 2021-09-22 Time 14:07 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2021-12-03 Cont ID  
Sent By jgomez Date 2021-12-03 Time 17:18 Rev Time 0.00
Received By jgomez Date 2021-12-03 Time 17:18 Sent To  
Notes
2021-12-03 17:21:23DISCUSSED WITH SAMANTHA HILL. PLANS DON'T SHOW SQUARE
 FOOTAGE ADDED. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-10-18 Cont ID  
Sent By jgomez Date 2021-10-18 Time 13:28 Rev Time 0.00
Received By jgomez Date 2021-10-18 Time 13:28 Sent To  
Notes
2021-10-18 13:29:06IMPACT FEES
  
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-11-18 Cont ID  
Sent By medwards Date 2021-11-18 Time 07:12 Rev Time 0.00
Received By medwards Date 2021-11-18 Time 07:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-11-04 Cont ID  
Sent By medwards Date 2021-11-04 Time 08:11 Rev Time 0.00
Received By medwards Date 2021-11-04 Time 08:09 Sent To  
Notes
2021-11-04 08:13:01PLEASE PROVIDE A MECHANICAL SCOPE OF WORK AND A
 MECHANICAL DRAWING SHOWING ALL MECHANICAL WORK BEING
 COMPLETED UNDER THIS PERMIT. FBC 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-09-23 Cont ID  
Sent By medwards Date 2021-09-23 Time 15:38 Rev Time 0.00
Received By medwards Date 2021-09-23 Time 15:38 Sent To  
Notes
2021-09-23 16:14:401) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS
 GARAGE CONVERSION.
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS FOR THE CONDITIONING OF THE NEW GARAGE
 CONVERSION.
 3) PROVIDE A MECHANICAL DRAWING SHOWING HOW THE NEW
 GARAGE CONVERSION IS CONDITIONED.
 4) THIS WORK WILL REQUIRE A MECHANICAL SUBPERMIT.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-11-08 Cont ID  
Sent By ccole Date 2021-11-08 Time 10:16 Rev Time 0.00
Received By ccole Date 2021-11-08 Time 09:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-09-30 Cont ID  
Sent By ccole Date 2021-09-30 Time 16:17 Rev Time 0.00
Received By ccole Date 2021-09-30 Time 15:36 Sent To  
Notes
2021-09-30 16:17:551ST REVIEW FBC-2020 RES.
 PERMIT- 21090524
 9/30/21
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET E-1: THE USE OF LEAD SHEET MATERIAL FOR THE
 SHOWER PAN LINER IS APPROVED ACCORDING TO SECTION
 P2709.2 FBC RES, ALTHOUGH THIS TYPE OF PAN LINER IS NOT
 TYPICALLY USED FOR RESIDENTIAL SHOWERS. THE DETAIL ON
 THE PLAN APPEARS TO BE COPIED AND PASTED. PLEASE VERIFY
 THIS THE TYPE OF LINER TO BE INSTALLED AS OPPOSED TO
 THE TYPICAL FACTORY-MADE PVC LINERS THAT ARE APPROVED
 UNDER P2709.2.1 FBC RES. A) PLEASE INDICATE THE SLOPE
 OF THE LINER IN THE DETAIL- SECTION P2709.3 FBC RES.
  
 2) PLEASE CORRECT THE 2-INCH WASHING MACHINE DRAIN
 STACK IN THE RISER TO SHOW A 3-INCH PER SECTION 406.2
 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2021-12-02 Cont ID  
Sent By jgomez Date 2021-12-02 Time 13:47 Rev Time 0.00
Received By jgomez Date 2021-12-02 Time 13:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2021-11-30 Cont ID  
Sent By jgomez Date 2021-11-30 Time 16:01 Rev Time 0.00
Received By jgomez Date 2021-11-30 Time 15:58 Sent To  
Notes
2021-11-30 16:03:49FIFTH SIGNATURE REVIEW COMMENTS:
  
 ORIGINAL COMMENT:
 1) DRAWING A-1 HAS A COPY OF THE DIGITAL SIGNATURE AND
 SEAL. NEED TO PROVIDE DRAWING WITH ORIGINAL DIGITAL
 SIGNATURE AS DONE WITH OTHER DRAWINGS SUBMITTED.
 FL. STATUTE 471.025, AND SECTION 61G15-23.005 FAC.
  
 RESPONSE:
 THE SINGATURE OF DRAWING A-1 SUBMITTED HAS AN INVALID
 TIMESTAMP.
  
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2021-11-30 Cont ID  
Sent By jgomez Date 2021-11-30 Time 09:56 Rev Time 0.00
Received By jgomez Date 2021-11-30 Time 09:52 Sent To  
Notes
2021-11-30 09:56:58FOURTH SIGNATURE REVIEW COMMENTS:
  
 REPEAT COMMENT. THREE TIMES:
 DRAWING SUBMITTED THIS TIME IS THE COVER SHEET CVR
 AGAIN. THIS IS NOT THE DRAWING THAT WAS REQUESTED TO
 HAVE THE ORIGINAL DIGITAL SIGNATURE. THE REQUESTED
 DRAWING IS DRAWING A-1 NOT THE COVER SHEET CVR. PLEASE
 READ COMMENT BELOW TO AVOID MORE CONFUSION AND
 UNNECESSARY DELAYS.
  
 1) DRAWING A-1 HAS A COPY OF THE DIGITAL SIGNATURE AND
 SEAL. NEED TO PROVIDE DRAWING WITH ORIGINAL DIGITAL
 SIGNATURE AS DONE WITH OTHER DRAWINGS SUBMITTED.
 FL. STATUTE 471.025, AND SECTION 61G15-23.005 FAC.
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-11-19 Cont ID  
Sent By jgomez Date 2021-11-19 Time 17:37 Rev Time 0.00
Received By jgomez Date 2021-11-19 Time 17:35 Sent To  
Notes
2021-11-19 17:38:10SIGNATURE REVIEW:
  
 REPEAT COMMENT
  
 1) DRAWING A-1 HAS A COPY OF THE DIGITAL SIGNATURE AND
 SEAL. NEED TO PROVIDE DRAWING WITH ORIGINAL DIGITAL
 SIGNATURE AS DONE WITH OTHER DRAWINGS SUBMITTED.
 FL. STATUTE 471.025, AND SECTION 61G15-23.005 FAC.
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-11-09 Cont ID  
Sent By jgomez Date 2021-11-09 Time 17:55 Rev Time 0.00
Received By jgomez Date 2021-11-09 Time 17:53 Sent To  
Notes
2021-11-09 18:00:59SIGNATURE REVIEW:
  
 1) DRAWING A-1 HAS A COPY OF THE DIGITAL SIGNATURE AND
 SEAL. NEED TO PROVIDE DRAWING WITH ORIGINAL DIGITAL
 SIGNATURE AS DONE WITH OTHER DRAWINGS SUBMITTED.
 FL. STATUTE 471.025, AND SECTION 61G15-23.005 FAC.
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-09-22 Cont ID  
Sent By ccole Date 2021-09-22 Time 15:52 Rev Time 0.00
Received By ccole Date 2021-09-22 Time 15:45 Sent To  
Notes
2021-09-22 15:53:19ELECTRONIC SIGNATURE REVIEW
 PERMIT- 21091020
 9/22/21
  
 RESULTS: DENIED.
  
 1) THE PLANS HAVE COPIED DIGITAL SIGNATURES AND SEALS.
 PROVIDE EITHER DIGITALLY SIGNED AND SEALED PLANS BY THE
 ENGINEER OF RECORD THAT ARE CAPABLE OF BEING VERIFIED,
 OR SUBMIT PAPER PLANS THAT BEAR EITHER RAISED OR INK
 SEALS AND WET SIGNATURES BY THE ENGINEER OF RECORD- FL.
 STATUTE 471.025, AND SECTION 61G15-23.005 FAC.
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status N Date 2021-10-18 Cont ID  
Sent By jgomez Date 2021-10-18 Time 14:23 Rev Time 0.00
Received By jgomez Date 2021-10-18 Time 14:23 Sent To  
Notes
2021-10-05 13:14:17MAIN HOUSE ONLY. INTERIOR WORK ONLY. IT DOESN'T AFFECT
 THE EXTERIOR OF THE BUILDING. JG.
  
 NOTE: GARAGE CONVERTED TO LIVABLE SPACE WITHOUT
 PERMITS. NEED PLANS UNDER A SEPARATE PERMIT
 APPLICATION. JG.