Plan Review Details - Permit 21090964
Plan Review Stops For Permit 21090964
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-02-17 Cont ID  
Sent By jwitmer Date 2022-02-17 Time 10:53 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-01-26 Cont ID  
Sent By jwitmer Date 2022-01-26 Time 08:17 Rev Time 0.00
Received By jwitmer Date 2022-01-26 Time 08:16 Sent To  
Notes
2022-01-26 08:16:43COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By jwitmer Date 2021-11-10 Time 10:36 Rev Time 0.00
Received By jwitmer Date 2021-11-10 Time 10:34 Sent To  
Notes
2021-11-10 10:36:46COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2022-05-31 Cont ID  
Sent By jwitmer Date 2022-05-31 Time 13:59 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-04-26 Cont ID  
Sent By jwitmer Date 2022-04-26 Time 13:26 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-02-22 Cont ID  
Sent By jwitmer Date 2022-02-22 Time 07:13 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-02-17 Cont ID  
Sent By jwitmer Date 2022-01-26 Time 11:25 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-01-26 11:24:58WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21090964
 ADD: 2611 MERCER AVE.
 CONT: ABACO BUILDERS
 TEL: 561-575-5393
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. JAN. 26TH/ 2021
 ACTION: DENIED
  
 1) SHEET A-1 PROJECT DATA:
 1A) 2ND REQUEST. CITY ELECTRIC SUPPLY HAS AN ELECTRICAL
 WHOLESALE NETWORK ACROSS THE USA AND CANADA. WHEN YOU
 LOOK AT THE DEFINITION OF MERCANTILE (2020
 FBC-BUILDING) SECTION 309.1 RETAIL OR WHOLESALE
 FACILITIES ARE INCLUDED UNDER THE OCCUPANCY OF
 MERCANTILE.
  
 1ST ROUND COMMENTS. LIST THE OCCUPANCY AS BUSINESS
 OCCUPANCY. PLEASE NOTE THIS IS A CHANGE OF OCCUPANCY,
 FORMERLY STORAGE OCCUPANCY. THE PROJECT DATA LIST THE
 OCCUPANCY TYPE AS BUSINESS OCCUPANCY. BUSINESS
 OCCUPANCIES ARE USUALLY OFFICES FOR PROFESSIONALS OR
 SERVICE TYPES TRANSACTIONS, IT CAN BE ARGUED THE
 OCCUPANCY TYPE IS MERCANTILE SINCE THERE IS A LARGE
 AREA VACANT BUT INDICATES COUNTER AREA. NEITHER THE A-1
 SHEET NOR THE LIFE SAFETY SHEET REALLY DEFINE THE OPEN
 SALES AREA WELL. 2020 FBC-BUILDING CODE SECTION 304.1
 VERSES SECTION 309.1 MERCANTILE AND SALES ROOMS.
  
 1B) 2ND REQUEST. PLEASE UPDATE THE OCCUPANCY TYPE AND
 OCCUPANT LOAD. MERCANTILE OCCUPANCY THE OCCUPANT LOAD
 WILL INCREASE FROM 10 (BUSINESS) TO 25 MERCANTILE 1498
 SQ. FT./ 60= 25 OCCUPANTS.
 1ST ROUND OF COMMENTS. THE OCCUPANT LOAD DOES NOT
 INDICATE THE SQUARE FOOTAGE OF THE AREA UNDERGOING THE
 CHANGE OF OCCUPANCY?107. 2.1.2. ADDITIONAL INFORMATION
 IS REQUIRED.
  
 1C) 2ND REVIEW. WITH THE PREVIOUS OCCUPANT LOAD COUNT
 BEING LESS THAN 15 A UNI-SEX RESTROOM COULD BE CODE
 COMPLIANT, BUT WITH THE NEW OCCUPANT LOAD FOR
 MERCANTILE OF 25 OCCUPANTS SEPARATE RESTROOM FACILITIES
 WILL BE REQUIRED. PLEASE REVIEW SECTION 2902.2 OF THE
 2020 FBC-BUILDING CODE.
 1ST ROUND OF COMMENTS. THE OCCUPANT LOAD DECLARED IS
 USING THE OCCUPANT LOAD FACTOR OF 100 SQ. FT./ OCCUPANT
 SUPPOSED BUSINESS OCCUPANCY. PLEASE REVIEW THE 2020
 FBC-BUILDING CODE TABLE 1004.5, THE OCCUPANT LOAD
 FACTOR FOR A BUSINESS OCCUPANCY IS CURRENTLY 150 SQ.
 FT./ OCCUPANT. NOTE FOR MERCANTILE OCCUPANCY THE
 OCCUPANT LOAD FACTOR IS 60 SQ. FT./ OCCUPANT TABLE
 1004.5 OF THE 2020 FBC-BUILDING CODE.
  
 1D)(1) 2ND REQUEST. WITH THE INCREASED OCCUPANT LOAD
 FOR A MERCANTILE OCCUPANCY OF 25 OCCUPANTS THE
 REQUIREMENT FOR DRINKING FOUNTAINS PER TABLE 2902.1
 REQUIRING DRINKING FOUNTAINS UNLESS COMPLIANCE CAN BE
 MET BY SECTION 2902.5.
 1ST ROUND OF COMMENTS. THE PLUMBING FIXTURE COUNT IS
 GOING TO VARY DEPENDING ON THE OCCUPANCY
 CLASSIFICATION. FOR THIS REVIEW A MERCANTILE OCCUPANCY
 WILL BE FIGURED SIMILAR TO AUTO ZONE WHERE THERE ARE
 MERCANTILE SHELVING RACKS IN THE FRONT PORTION, SALES
 /TRANSACTION COUNTERS AND WAREHOUSE SECTION BEHIND THE
 COUNTERS. THE PROPOSED TENANT IS CITY ELECTRIC SUPPLY.
  
 1D)(2) NEW COMMENT. 2020 FBC-ACCESSIBILITY CODE. 211.3
 MORE THAN MINIMUM NUMBER. WHERE MORE THAN THE MINIMUM
 NUMBER OF DRINKING FOUNTAINS SPECIFIED IN 211.2 ARE
 PROVIDED, 50 PERCENT OF THE TOTAL NUMBER OF DRINKING
 FOUNTAINS PROVIDED SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND 50 PERCENT SHALL OF THE TOTAL NUMBER OF
 DRINKING FOUNTAINS PROVIDED SHALL COMPLY WITH 602.7.
  
 1D)(3) NEW COMMENT. PROTRUDING OBJECTS 307.2 PROTRUSION
 LIMITS 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27
 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR
 SHALL NOT PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO
 THE CIRCULATION PATH.
  
 1D)(4) NEW COMMENT. 602.2 CLEAR FLOOR SPACE. A CLEAR
 FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A
 FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING
 WITH 306 SHALL BE PROVIDED.
  
 1D)(5) NEW COMMENT. SPOUT OUTLETS/ DRINKING FOUNTAINS.
 2017 ACCESS. CODE. SPOUT OUTLETS SHALL COMPLY WITH:
 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND FOR WHEELCHAIR BOUND INDIVIDUALS.
 602.7 SPOUT HEIGHT FOR THE STANDING PERSONS SHALL BE
 BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
 1E-F) COMPLIED.
  
 1G) NEW COMMENT. THE FLOOR PLAN SHOW THE OCCUPANCY
 SEPARATION WALL ONE HOUR AND DOOR NUMBER 3 WITH NOTE TO
 HAVE SELF CLOSING DEVISE AND MEET ADA STANDARDS.
 DISCREPANCY DOOR # 3 IN THE DOOR SCHEDULE STATES
 PASSAGE SET HARDWARE/ 1 HR. RATED. DISCREPANCY. 2020
 FBC-B SECTION 716.5.9 FIRE DOORS, CLOSING.
  
 2) COMPLIED.
  
 3) SHEET A-3 ELEVATIONS:
 3A-B) COMPLIED.
  
 3C)2ND REQUEST. 1 HOUR FIRE RATED STUD UL LISTING U 465
 MISSING INFORMATION THE MINIMUM GAUGE FOR THE FIRE
 RATING AND MAXIMUM LENGTH OF FIRE RATED STUD? PROVIDE
 THE ACTUAL UL LISTING ON THE PLANS, THE INSPECTOR DOES
 NOT HAVE A BOOK OF UL LISTINGS. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 4) CHANGE OF OCCUPANCY MAY REQUIRE IMPACT FEE
 ASSESSMENT. IMPACT FEES - DIGITAL SUBMITTALS: PLANS
 WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY
 VIA PROJECT DOX UPON NOTIFICATION BY THIS OFFICE.
 NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL
 FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT
 (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT
 FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE
 FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN
 BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected].
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By jwitmer Date 2021-11-10 Time 14:30 Rev Time 0.00
Received By jwitmer Date 2021-11-10 Time 10:34 Sent To  
Notes
2021-11-10 14:30:03WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21090964
 ADD: 2611 MERCER AVE.
 CONT: ABACO BUILDERS
 TEL: 561-575-5393
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. NOV. 10TH/ 2021
 ACTION: DENIED
  
 1) SHEET A-1 PROJECT DATA:
 1A) LIST THE OCCUPANCY AS BUSINESS OCCUPANCY. PLEASE
 NOTE THIS IS A CHANGE OF OCCUPANCY, FORMERLY STORAGE
 OCCUPANCY. THE PROJECT DATA LIST THE OCCUPANCY TYPE AS
 BUSINESS OCCUPANCY. BUSINESS OCCUPANCIES ARE USUALLY
 OFFICES FOR PROFESSIONALS OR SERVICE TYPES
 TRANSACTIONS, IT CAN BE ARGUED THE OCCUPANCY TYPE IS
 MERCANTILE SINCE THERE IS A LARGE AREA VACANT BUT
 INDICATES COUNTER AREA. NEITHER THE
 A-1 SHEET NOR THE LIFE SAFETY SHEET REALLY DEFINE THE
 OPEN SALES AREA WELL. 2020 FBC-BUILDING CODE SECTION
 304.1 VERSES SECTION 309.1 MERCANTILE AND SALES ROOMS.
  
 1B) THE OCCUPANT LOAD DOES NOT INDICATE THE SQUARE
 FOOTAGE OF THE AREA UNDERGOING THE CHANGE OF
 OCCUPANCY?107. 2.1.2. ADDITIONAL INFORMATION IS
 REQUIRED.
  
 1C) THE OCCUPANT LOAD DECLARED IS USING THE OCCUPANT
 LOAD FACTOR OF 100 SQ. FT./ OCCUPANT SUPPOSED BUSINESS
 OCCUPANCY. PLEASE REVIEW THE 2020 FBC-BUILDING CODE
 TABLE 1004.5, THE OCCUPANT LOAD FACTOR FOR A BUSINESS
 OCCUPANCY IS CURRENTLY 150 SQ. FT./ OCCUPANT. NOTE FOR
 MERCANTILE OCCUPANCY THE OCCUPANT LOAD FACTOR IS 60 SQ.
 FT./ OCCUPANT TABLE 1004.5 OF THE 2020 FBC-BUILDING
 CODE.
  
 1D) THE PLUMBING FIXTURE COUNT IS GOING TO VARY
 DEPENDING ON THE OCCUPANCY CLASSIFICATION. FOR THIS
 REVIEW A MERCANTILE OCCUPANCY WILL BE FIGURED SIMILAR
 TO AUTO ZONE WHERE THERE ARE MERCANTILE SHELVING RACKS
 IN THE FRONT PORTION, SALES /TRANSACTION COUNTERS AND
 WAREHOUSE SECTION BEHIND THE COUNTERS. THE PROPOSED
 TENANT IS CITY ELECTRIC SUPPLY.
  
 1E) ENGINEERING DATA LIST THE OCCUPANCY TYPE AS R3,
 SINGLE FAMILY RESIDENCES. PLEASE CORRECT.
  
 1F) THE FLOOR PLAN SHOWS A BACK-WALL DIMENSION OF
 7FEET. CLEARANCES AT WATER CLOSETS. 604.3 CLEARANCE.
 CLEARANCES AROUND THE WATER CLOSETS AND IN TOILET
 COMPARTMENTS SHALL COMPLY WITH 604.3.
 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR
 WALL. NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE
 7-FOOT 1 INCH (FINISHES MAY ENCROACH) ON THE FINISH
 DIMENSION!!!
  
 2) THE LIFE SAFETY SHEET DESIGN DATA THE MAXIMUM
 CAPACITY SIGN READS FOR ONE EXIT: THE MAIN ENTRANCE
 DOOR IN EACH SPACE WITH A CAPACITY OF 50 OR MORE
 OCCUPANTS. PLEASE CORRECT, SEE THE 2020 FBC-BUILDING
 CODE TABLE 1006.2.1 B OCCUPANCY WITH ONE EXIT OR EXIT
 ACCESS DOORWAY MAXIMUM OCCUPANT LOAD OF SPACE 49
 OCCUPANTS.
  
 3) SHEET A-3 ELEVATIONS:
 3A) BOTH ELEVATIONS 1 & 3 SHOW THE GRAB BARS
 DIMENSIONED FROM CENTERLINE TO THE FINISH FLOOR. 2020
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 3B) BOTH ELEVATIONS 1 & 2 SHOW LAVATORY PIPES EXPOSED.
 2020 FBC-ACCESSIBILITY CODE SECTION 606.5 EXPOSED PIPES
 AND SURFACES. WATER SUPPLY & DRAINPIPES UNDER
 LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE
 CONFIGURED TO PROTECT AGAINST CONTACT.
  
 3C) 1 HOUR FIRE RATED STUD UL LISTING U 465 MISSING
 INFORMATION THE MINIMUM GAUGE FOR THE FIRE RATING AND
 MAXIMUM LENGTH OF FIRE RATED STUD? 107.2.1.2.
  
 4) CHANGE OF OCCUPANCY MAY REQUIRE IMPACT FEE
 ASSESSMENT. IMPACT FEES - DIGITAL SUBMITTALS: PLANS
 WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY
 VIA PROJECT DOX UPON NOTIFICATION BY THIS OFFICE.
 NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL
 FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT
 (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT
 FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE
 FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN
 BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected].
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-11-16 Cont ID  
Sent By jleahy Date 2021-11-16 Time 16:32 Rev Time 0.00
Received By jleahy Date 2021-11-16 Time 15:58 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-08-10 Cont ID  
Sent By jleahy Date 2022-08-10 Time 10:35 Rev Time 0.00
Received By jleahy Date 2022-08-10 Time 10:34 Sent To  
Notes
2022-08-10 10:35:25VOICE AND DATA JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2022-05-27 Cont ID  
Sent By cwalker Date 2022-05-27 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-04-15 Cont ID  
Sent By cwalker Date 2022-04-15 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-02-17 Cont ID  
Sent By cwalker Date 2022-02-17 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-20 Cont ID  
Sent By cwalker Date 2022-01-20 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-10-06 Cont ID  
Sent By cwalker Date 2021-10-06 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-06-13 Cont ID  
Sent By medwards Date 2022-06-13 Time 12:40 Rev Time 0.00
Received By medwards Date 2022-05-26 Time 16:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-05-05 Cont ID  
Sent By medwards Date 2022-05-05 Time 15:39 Rev Time 0.00
Received By medwards Date 2022-04-14 Time 08:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-07 Cont ID  
Sent By medwards Date 2022-03-07 Time 11:15 Rev Time 0.00
Received By medwards Date 2022-02-16 Time 07:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-08 Cont ID  
Sent By lmarchan Date 2022-02-08 Time 15:50 Rev Time 0.00
Received By lmarchan Date 2022-01-19 Time 07:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-16 Cont ID  
Sent By jleahy Date 2021-11-16 Time 16:32 Rev Time 0.00
Received By jleahy Date 2021-10-04 Time 15:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-06-24 Cont ID  
Sent By aoliver Date 2022-06-24 Time 10:09 Rev Time 0.00
Received By aoliver Date 2022-06-21 Time 07:33 Sent To  
Notes
2022-06-27 08:17:09NO FEES DUE FOR IMPACT. LEM
2022-06-21 07:34:1606/21/22 EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By jwitmer Date 2021-11-10 Time 14:30 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2021-11-10 14:30:28CHANGE OF OCCUPANCY MAY REQUIRE IMPACT FEE ASSESSMENT.
 IMPACT FEES - DIGITAL SUBMITTALS: PLANS WILL BE
 REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA
 PROJECT DOX UPON NOTIFICATION BY THIS OFFICE.
 NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL
 FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT
 (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT
 FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE
 FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN
 BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected].

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2022-06-13 Cont ID  
Sent By medwards Date 2022-06-13 Time 12:38 Rev Time 0.00
Received By medwards Date 2022-06-13 Time 12:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2022-05-05 Cont ID  
Sent By medwards Date 2022-05-05 Time 15:39 Rev Time 0.00
Received By medwards Date 2022-05-05 Time 15:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-03-07 Cont ID  
Sent By medwards Date 2022-03-07 Time 11:14 Rev Time 0.00
Received By medwards Date 2022-03-07 Time 11:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-02-08 Cont ID  
Sent By medwards Date 2022-02-08 Time 15:42 Rev Time 0.00
Received By medwards Date 2022-02-08 Time 15:41 Sent To  
Notes
2022-02-08 15:45:40MECHANICAL RESPONSE FOR NOTE 2 AND 3 ARE NOT ON SHEET
 MP-1 ADDRESSING THE 1ST CYCLE MECHANICAL REVIEW
 COMMENTS BELOW:
  
 PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON
 EACH USE OF SPACE IN THIS TENANT SPACE.
  
 PLEASE SHOW CONDENSATE PIPING MATERIAL AND TERMINATION
 LOCATION FOR NEW RTU.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-11-04 Cont ID  
Sent By medwards Date 2021-11-04 Time 06:58 Rev Time 0.00
Received By medwards Date 2021-11-04 Time 06:58 Sent To  
Notes
2021-11-04 06:59:081ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21090964
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE A ROOF DETAIL FOR THE NEW 5-TON UNIT.
 FBC 107.2.1
  
 2) PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THE
 USE OF SPACE FOR THE ENTIRE TENANT SPACE. FBC M
 403.3.1.1 AND TABLE 403.3.1.1
  
 3) PLEASE SHOW THE CONDENSATE DRAIN AND TERMINATION
 LOCATION FOR THE NEW 5-TON UNIT. FBC M 307
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2022-06-02 Cont ID  
Sent By ccole Date 2022-06-02 Time 17:31 Rev Time 0.00
Received By ccole Date 2022-06-02 Time 17:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2022-04-28 Cont ID  
Sent By ccole Date 2022-04-28 Time 17:56 Rev Time 0.00
Received By ccole Date 2022-04-28 Time 14:15 Sent To  
Notes
2022-04-28 17:58:554TH REVIEW FBC-2020 PLUMBING
 PERMIT- 21090964
 4/28/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REVISED SHEETS A3 & MP1: THE REVISED PLANS SHOWING A
 NEW INSTA-HOT WATER HEATER IN THE EXISTING STORAGE TANK
 WATER HEATER ARE NOT IN COMPLIANCE WITH THE FOLLOWING
 CODE SECTIONS-
  
 A) SEC. 502.5: 30X30-INCH CLEAR WORKING SPACE ON THE
 CONTROL SIDE OF THE INSTA-HOT FOR SERVICE ACCESS NOT
 PROVIDED.
  
 B) SEC. 502.1 FBC P & TABLE C404.2 FBC EC: INSTA-HOT
 EQUIPMENT SCHEDULED NOT PROVIDED ON THE PLAN- MAKE,
 MODEL, EFFICIENCY RATING.
  
 C) SEC. 607.2 FBC P & 107.3.5.1.3 WPB: A HWR LINE
 SYMBOL NOT PROVIDED ON THE RISER ON LAYOUT DRAWING. IT
 APPEARS THE RETURN LINE HAS THE HW LINE SYMBOL AND THE
 LINE IS FEEDING DIRECTLY INTO THE COLD WATER INLET OF
 THE SMALL TANK WATER HEATER. TYPICALLY, THE HWR
 CONNECTS TO THE COLD WATER INLET PIPE OF THE WATER
 HEATER.
  
 D) SEC. C404.1 FBC EC: THE 1/2-INCH HW LAVATORY FIXTURE
 PIPES ARE EXCEEDING THE MAXIMUM 2FT. ALLOWABLE LENGTH
 FROM THE HOT WATER SOURCE. IN ORDER TO BE COMPLIANT THE
 LOOP SHALL EXTEND DOWN IN THE WALL TO THE LAV FIXTURE
 SUPPLY PIPE LOCATION.
  
 2) SHEETS A2, A3, AND E-1 DO NOT MATCH WITH THE OTHER
 PLANS BECAUSE THE INSTA-HOT IN THE CLOSET IS NOT SHOWN-
 SEC. 107.2.1 WPB.
  
 3) SHEET A1: PLEASE CORRECT THE NOTE AT THE WATER
 HEATER SPECIFYING A ASSE 1070 TEMPERED WATER MIXING
 VALVE AT THE WATER HEATER. A TEMPERED WATER MIXING
 VALVE IS ONLY NEEDED AT THE LAVATORIES PER SECS. 419.5
 & 607.2.1 FBC P. IF INSTALLING A MASTER THERMOSTATIC
 MIXING VALVE AT THE WATER HEATER IT SHALL BE LISTED FOR
 LIMITING THE TEMPERATURE OF HOT WATER TO THE FIXTURES
 PER SECTION 607.1.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE CONTACT ME IF YOU HAVE
 QUESTIONS.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS ST.
 WEST PALM BEACH, FL. 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-03-01 Cont ID  
Sent By ccole Date 2022-03-01 Time 11:25 Rev Time 0.00
Received By ccole Date 2022-03-01 Time 08:19 Sent To  
Notes
2022-03-01 11:26:203RD REVIEW FBC-2020 PLUMBING
 PERMIT- 21090964
 3/1/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET MP-1 & A-3: THE REQUIRED SERVICE SINK IS NOT
 SHOWN ON THE PLANS, RISERS, OR IN THE FIXTURE SCHEDULE-
 TABLE 403.1 FBC P.
  
 2) MP-1: PLEASE REVISE KEYNOTE 2 TO INDICATE THE
 TEMPERED WATER WILL DELIVERED AT A TEMPERATURE BETWEEN
 85 DEGREES AND 110 DEGREES F. HOT WATER IS DEFINED AS
 WATER AT A TEMPERATURE OF 110 DEGREES F AND ABOVE.
  
 3) A-3: THE RISER DRAWINGS DO NOT SHOW THE PLUMBING
 PIPING FOR THE NEW DRINKING FOUNTAINS- SEC. 107.2.1
 WPB.
  
 4) A-3: THE SANITARY AND WATER RISERS DO NOT MATCH. THE
 SANITARY RISER SHOWS ONE LAVATORY, ONE WATER CLOSET AND
 TWO SINKS. THE WATER RISER SHOWS TWO LAVATORIES AND ONE
 WATER CLOSET- SEC. 107.2.1 WPB. PLEASE USE THE L-1 OR
 S-1 LABELS AS SHOW IN THE FIXTURE SCHEDULE TO IDENTIFY
 THE FIXTURES.
  
 5) A-3: THE SANITARY RISER IS STILL SHOWING THE FIXTURE
 DRAIN FROM THE NEW SINK MAKING A PROHIBITED CONNECTION
 INT THE BATHROOM WET VENT- SEC. 912.1 FBC P.
  
 6) A-3: PLEASE SHOW THE RECIRCULATION LINE AND LOOP IN
 THE WATER RISER- SEC. 607.2 FBC P.
  
 7) MP-1 & A-3: PLEASE NOTE THAT THE THERMOSTAT ON THE
 WATER HEATER SHALL NOT SERVE AS THE WATER TEMPERATURE
 LIMITING MEANS FOR ALL FIXTURES THAT REQUIRE HOT WATER
 SUCH AS THE NEW S-1 SINK. THE HOT WATER TEMPERATURE
 SHALL BE CONTROLLED BY A MASTER THERMOSTATIC MIXING
 VALVE AT THE WATER HEATER OR AT THE LOCALLY AT THE
 SINK- SEC. 607.1.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE CONTACT ME IF YOU HAVE
 QUESTIONS.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-02-02 Cont ID  
Sent By ccole Date 2022-02-02 Time 13:25 Rev Time 0.00
Received By ccole Date 2022-02-02 Time 10:38 Sent To  
Notes
2022-02-02 13:26:182ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21090964
 2/2/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN
 CAP LETTERS. PLEASE NOTE THAT THE BUILDING PLANS
 EXAMINER DISGAGREES WITH THE OCCUPANT LOAD
 CLASSIFICATION OF B FOR THE NEW COUNTER AREA 100 AND IS
 STATING THAT IT IS AN M. THE FOLLOWING REVIEW IS BASED
 ON THE CURRENT SET OF PLANS RESUBMITTED HOWEVER IF THE
 CLASSIFICATION IS REVISED TO INDICATE M THERE MAY BE
 ADDITIONAL COMMENTS.
  
 1) FAILED. SHEET A-1: A COMPLETE PLUMBING REVIEW OF THE
 PROJECT CANNOT BE COMPLETED WITHOUT PLUMBING FIXTURE
 CALCULATIONS. THE PLANS APPEAR TO INDICATE A PARTIAL
 CHANGE OF OCCUPANCY FROM STORAGE TO MERCANTILE
 (SALES-SHOWROOM)- SEE SECTIONS 309.1 FBC B, AND SECTION
 1010.1 FBC EX. REFER TO TABLE 403.1 FBC P AND PROVIDE A
 SCHEDULE THAT INDICATES THE REQUIRED AND PROVIDED
 PLUMBING FIXTURES. PLEASE NOTE THAT SERVICE SINKS AND
 DRINKING FOUNTAINS ARE REQUIRED, AND SEPARATE TOILET
 FACILITIES FOR MALE AND FEMALE USE UNLESS MEETING THE
 EXCEPTIONS UNDER SECTION 403.2 FBC P. THE PLAN SHOWS 17
 OCCUPANTS. AS PREVIOUSLY NOTED, DRINKING FOUNTAINS AND
 SERVICE SINK ARE REQUIRED- TABLE 403.1E AND SEC. 410.2
 FBC P. REVISE THE CALCULATIONS AND PLANS TO SHOW THE
 FIXTURE LOCATIONS AND PLUMBING PIPING DETAILS.
  
 2) FAILED. SHEET A-3: THE NEW SINK IN THE SALES AREA
 REQUIRES A SEPARATE VENT AND THE SINK FIXTURE DRAIN
 MUST CONNECT TO THE MAIN SANITARY AT A POINT DOWNSTREAM
 OF THE WET VENT FOR THE NEW TOILET ROOM- SECTION 912.1
 CORRECTION WAS NOT MADE- THE RISER IS STILL
 NON-COMPLIANT- SEC. 912.1 FBC P.
  
 3) FAILED. A-3 & MP-1: INDICATE HOW TEMPERED WATER WILL
 BE PROVIDED TO THE NEW LAVATORY- SECTION 416.5 FBC P.
 IF A MIXING VALVE IS TO BE USED PLEASE LIST THE MAKE
 AND MODEL AND VERIFY IT IS ASSE 1070 APPROVED- SECTION
 607.1.2 FBC P. TEMPERED WATER IS DEFINED AS WATER WITH
 A TEMPERATURE RANGE BETWEEN 85 DEGREES F AND 110
 DEGREES F. A MASTER MIXING VALVE CANNOT BE USED BECAUSE
 ONLY THE LAVATORY REQUIRES TEMPERED WATER AND THE OTHER
 SINKS REQUIRE HOT WATER AT 110 DEGREES F AND ABOVE.
 REMOVE THE MASTER MIXING VALVE AND SHOW A MIXING VALVE
 AT THE LAVATORY TO MEET COMPLIANCE.
  
 6) FAILED. MP-1: PLEASE INCLUDE THE SALES SINK IN THE
 PLUMBING FIXTURE SCHEDULE- SECTION 308 FBC ACC, AND
 422.1 FBC P. TWO SINKS ARE SHOWN IN THE RISER ON A3 AND
 ON THE MP-1 BUT ONLY S-1 IS SHOWN IN THE SCHEDULE.
 PLEASE IDENTIFY THE SECOND SINK- SEC. 107.2.1 WPB.
  
 7H) FAILED. KNEE AND TOE CLEARANCES FOR THE LAVATORIES-
 SECTION 606.2 (DETAIL IS NOT IN COMPLIANCE WITH FIGURE
 306.3- KNEE CLEARANCE WIDTH AND HEIGHT NOT SHOWN). NOT
 PROVIDED.
  
 8) FAILED. DRINKING FOUNTAINS WHERE REQUIRED: REFER TO
 SECTIONS 306, 307, AND 602 FBC ACC AND PROVIDE DRINKING
 FOUNTAIN INSTALLATION DETAILS AND ELEVATION VIEWS
 SHOWING KNEE AND TOE CLEARANCES, SPOUT HEIGHTS, AND
 SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 IN. CLEAR
 FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH TO THE
 WHEELCHAIR ACCESSIBLE FOUNTAIN- SECTION 602.2 FBC ACC.
 INDICATE COMPLIANCE WITH SECTION 307.2 PROTRUSION
 LIMITS. NOT PROVIDED- SEE COMMENT #1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-11-08 Cont ID  
Sent By ccole Date 2021-11-08 Time 09:36 Rev Time 0.00
Received By ccole Date 2021-11-08 Time 07:47 Sent To  
Notes
2021-11-08 09:38:201ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21090964
 11/8/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-1: A COMPLETE PLUMBING REVIEW OF THE PROJECT
 CANNOT BE COMPLETED WITHOUT PLUMBING FIXTURE
 CALCULATIONS. THE PLANS APPEAR TO INDICATE A PARTIAL
 CHANGE OF OCCUPANCY FROM STORAGE TO MERCANTILE
 (SALES-SHOWROOM)- SEE SECTIONS 309.1 FBC B, AND SECTION
 1010.1 FBC EX. REFER TO TABLE 403.1 FBC P AND PROVIDE A
 SCHEDULE THAT INDICATES THE REQUIRED AND PROVIDED
 PLUMBING FIXTURES. PLEASE NOTE THAT SERVICE SINKS AND
 DRINKING FOUNTAINS ARE REQUIRED, AND SEPARATE TOILET
 FACILITIES FOR MALE AND FEMALE USE UNLESS MEETING THE
 EXCEPTIONS UNDER SECTION 403.2 FBC P.
  
 2) SHEET A-3: THE NEW SINK IN THE SALES AREA REQUIRES A
 SEPARATE VENT AND THE SINK FIXTURE DRAIN MUST CONNECT
 TO THE MAIN SANITARY AT A [POINT DOWNSTREAM OF THE WET
 VENT FOR THE NEW TOILET ROOM- SECTION 912.1 FBC P.
  
 3) A-3 & MP-1: INDICATE HOW TEMPERED WATER WILL BE
 PROVIDED TO THE NEW LAVATORY- SECTION 416.5 FBC P. IF A
 MIXING VALVE IS TO BE USED PLEASE LIST THE MAKE AND
 MODEL AND VERIFY IT IS ASSE 1070 APPROVED- SECTION
 607.1.2 FBC P.
  
 4) MP-1: PROVIDE THE TYPE AND THICKNESS OF HOT WATER
 PIPE INSULATION- TABLE C403.5.3 FBC EC.
  
 5) MP-1: REFER TO TABLE C404.5.1 FBC EC- THE 1/2-INCH
 HW PIPING TO THE LAVATORIES IS EXCEEDING THE MAXIMUM 2
 FT. LENGTH ALLOWABLE FROM THE HW SOURCE (WATER HEATER).
 PROVIDE EITHER A RECIRCULATION PUMP OR A POINT OF USE
 WATER HEATER.
  
 6) MP-1: PLEASE INCLUDE THE SALES SINK IN THE PLUMBING
 FIXTURE SCHEDULE- SECTION 308 FBC ACC, AND 422.1 FBC P.
  
 7) A-1 & A-3: MISSING AND INCORRECT DETAILS PER THE FBC
 ACCESSIBILITY CODE:
 A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 WATER CLOSETS- SECTION 604.3.
 B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 LAVATORIES- SECTION 606.2.
 C) TURNING SPACE DIAGRAM AND DIAMETER- SECTION 304.3.
 D) HEIGHT OF THE WATER CLOSET SEAT FROM THE FINISHED
 FLOORS- SECTION 604.4. (DETAILS SHOW MEASUREMENT IS NOT
 TO THE SEAT).
 E) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOORS TO
 THE REFLECTIVE SURFACES- SECTION 603.3 (DETAIL SHOWS
 MEASUREMENT IS NOT TO THE REFLECTIVE SURFACE).
 F) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4,
 FIGURES 604.5.1 & 604.5.2. (DETAILS SHOW- A. REAR GRAB
 IS NON-COMPLIANT. B. SIDE GRAB DOES INDICATE THE
 MINIMUM 54-INCH EXTENSION FROM THE REAR WALL. C.
 HEIGHTS ARE NOT SHOWN TO THE TOPS OF THE GRIPPING
 SURFACES).
 G) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS -
 SECTION 604.6. (DETAIL DOES NOT SHOW THE LOCATION ON
 THE OPEN SIDE).
 H) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 606.2 (DETAIL IS NOT IN COMPLIANCE WITH FIGURE 306.3-
 KNEE CLEARANCE WIDTH AND HEIGHT NOT SHOWN).
  
 8) DRINKING FOUNTAINS WHERE REQUIRED: REFER TO SECTIONS
 306, 307, AND 602 FBC ACC AND PROVIDE DRINKING FOUNTAIN
 INSTALLATION DETAILS AND ELEVATION VIEWS SHOWING KNEE
 AND TOE CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS.
 SHOW THE REQUIRED 30 X 48 IN. CLEAR FLOOR SPACE FOR A
 FORWARD WHEELCHAIR APPROACH TO THE WHEELCHAIR
 ACCESSIBLE FOUNTAIN- SECTION 602.2 FBC ACC. INDICATE
 COMPLIANCE WITH SECTION 307.2 PROTRUSION LIMITS.
  
 9) A-1 & A-3, SALES SINK: A) SHOW THE CLEAR FLOOR SPACE
 DIAGRAM AND DIMENSIONS FOR EITHER A FORWARD OR PARALLEL
 APPROACH- SECTION 606.3. B) PROVIDE AN ELEVATION DETAIL
 SHOWING THE SINK RIM POR COUNTER HEIGHT (IF
 UNDERMOUNT), AND THE REQUIRED KNEE AND TOES CLEARANCES
 IF A FORWARD APPROACH IS TO BE USED- SECTIONS 606.2 &
 606.3 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-06-13 Cont ID  
Sent By medwards Date 2022-06-13 Time 12:39 Rev Time 0.00
Received By medwards Date 2022-06-13 Time 12:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-05-05 Cont ID  
Sent By medwards Date 2022-05-05 Time 15:39 Rev Time 0.00
Received By medwards Date 2022-05-05 Time 15:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-03-07 Cont ID  
Sent By medwards Date 2022-03-07 Time 11:14 Rev Time 0.00
Received By medwards Date 2022-03-07 Time 11:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-02-08 Cont ID  
Sent By medwards Date 2022-02-08 Time 15:47 Rev Time 0.00
Received By medwards Date 2022-02-08 Time 15:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-11-04 Cont ID  
Sent By medwards Date 2021-11-04 Time 06:59 Rev Time 0.00
Received By medwards Date 2021-11-04 Time 06:59 Sent To  
Notes
***NONE***