| Plan Review Stops For Permit 21090851 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-10-05 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-10-05 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2021-10-05 15:04:00 | ADDRESS PRIVIOUSLY AGREED UPON |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-01 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-01 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-11-01 |
Time |
22:57 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-11-01 |
Time |
21:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-10-15 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-10-15 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-10-08 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-10-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2021-10-08 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2021-10-08 11:20:05 | THE FOLLOWING COMMENTS WERE SUBMITTED BY LT. BRIAN | | | DOLAN, DIVISION OF FIRE PREVENTION, WEST PALM BEACH | | | FIRE RESCUE. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | | BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING | | | COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. | | | | | | ALL WORK ON THE FIRE SPRINKLER SYSTEM IAND/OR FIRE | | | UNDERGROUND S REQUIRED TO BE COMPLETED BY A CERTIFIED | | | CONTRACTOR AND SHALL COMPLY WITH APPLICABLE CODES. | | | SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION AND WORK ON THE SYSTEMS | | | | | | HYDROSTATIC TESTS. ALL PIPING AND ATTACHED | | | APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE | | | SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) | | | AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 | | | HOURS. | | | | | | | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-11-01 |
Time |
22:57 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-10-06 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2021-10-21 |
Time |
19:22 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2021-10-21 |
Time |
19:21 |
Sent To |
|
|
| Notes |
| 2021-10-21 19:23:19 | PER 10/21/21 EMAIL FROM DERREK MOORE, IMPACT FEE | | | OFFICE, IT IS OK TO ISSUE THE FOUNDATION PERMIT PRIOR | | | TO PAYMENT OF IMPACT FEES WHICH MUST BE PAID PRIOR TO | | | ISSUANCE OF BUILDING PERMIT 21070679. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-25 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-25 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2021-10-25 09:08:13 | FOUNDATION FOR NEW SFPGA BUILDING (BLDG PERMIT | | | 21070679) | | | | | | 10/25/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-01 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-01 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-10-18 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-10-18 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2021-10-18 11:18:44 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 10.18.2021 | | | PERMIT NO.: 21090851 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW IS FOR THE FOUNDATION OF THE SFPGA OFFICE | | | BUILDING ONLY. THIS REVIEW HAS BEEN PASSED SUBJECT TO | | | THE FOLLOWING PROVISOS: | | | | | | 1. IN ADDITION TO PERMITS FOR THE STRUCTURE, SEPARATE | | | PERMITS ARE ALSO REQUIRED FOR: | | | | | | 1.1. LANDSCAPING | | | 1.2. FENCING/GATES | | | 1.3. SITE/PRIVACY WALLS | | | 1.4. SITE LIGHTING | | | 1.5. IRRIGATION | | | 1.6. GENERATOR | | | 1.7. SIGNAGE | | | 1.8. PARING LOT / STRIPING / HARDSCAPE | | | 1.9. SITE FIXTURES (I.E. BIKE RACKS, ETC.) | | | | | | 2. THE WPB GOLF PARK DEVELOPMENT SHALL BE SUBJECT TO | | | ALL DEVELOPMENT ORDER CONDITIONS, AS OUTLINED IN FORMAL | | | SITE PLAN REVIEW (FSPR) CASE NO. 21-02, AND AS MAY BE | | | AMENDED. ALL CONDITIONS OF APPROVAL IMPOSED BY FSPR | | | CASE NO. 21-02, AS AMENDED, SHALL BE ADDRESSED WITHIN | | | THE APPROPRIATE SPECIFIED TIMEFRAMES. | | | | | | 3. A REVISION TO THE BUILDING AND LANDSCAPE PERMITS | | | SHALL BE SUBMITTED AND APPROVED TO REVISE THE PLANS AND | | | ACCURATELY REFLECT THE FOLLOWING: | | | | | | 3.1 DETAIL ON THE MARKING FOR COMPACT PARKING SPACES. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|