Plan Review Details - Permit 21090601
Plan Review Stops For Permit 21090601
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-10-07 Cont ID  
Sent By pvalenti Date 2021-10-07 Time 16:15 Rev Time 0.00
Received By pvalenti Date 2021-10-07 Time 16:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-10-06 Cont ID  
Sent By pvalenti Date 2021-10-06 Time 07:48 Rev Time 0.00
Received By pvalenti Date 2021-10-06 Time 07:44 Sent To  
Notes
2021-10-06 07:53:52PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1:
 PROVIDE A LAYOUT SHEET INDICATING THE LOCATION OF FLAT
 AND SLOPED ROOF AREAS.
  
 PROVIDE AN ENGINEER'S LETTER DETAILING THE FASTENER
 SPACING INCLUDING PERIMETER AND CORNER AREAS. ALSO
 PROVIDE THE CALCULATIONS WITH THE CORRECT DESIGN
 PRESSURES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-27 Cont ID  
Sent By pvalenti Date 2021-09-27 Time 07:19 Rev Time 0.00
Received By pvalenti Date 2021-09-27 Time 07:13 Sent To  
Notes
2021-09-27 07:29:49PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1:
  
 1) PROVIDE A ROOF LAYOUT/SKETCH OF THE ROOF. THE
 LAYOUT/SKETCH NEEDS TO IDENTIFY THE FLAT AND PITCHED
 AREAS.
 2) PROVIDE ALL OF THE PRODUCT APPROVALS FOR THE FLAT
 ROOF INCLUDING UNDERLAYMENT. WITHIN ALL PRODUCT
 APPROVALS THE SYSTEMS/OPTIONS NEED TO BE
 SELECTED/CIRCLED.
 3) AN ENGINEER'S DETAILED LETTER MAY BE REQUIRED. THIS
 DETAIL WILL NEED TO SHOW THE UNDERLAYMENT FASTENER
 SPACING AND CALCULATIONS TO SHOW THE WINDLOAD PRESSURES
 HAVE BEEN MET PER THE FLORIDA BUILDING CODE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-06 Cont ID  
Sent By pvalenti Date 2021-10-06 Time 07:54 Rev Time 0.00
Received By pvalenti Date 2021-09-28 Time 10:05 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-10-07 Cont ID  
Sent By pvalenti Date 2021-10-07 Time 16:15 Rev Time 0.00
Received By pvalenti Date 2021-10-07 Time 16:15 Sent To  
Notes
2021-10-07 16:18:07PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 SIGNATURE REVIEW NOT REQUIRED,
 SYSTEM MEETING WINDLOAD REQUIREMENTS COVERED IN NEMO
 REPORT.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-10-06 Cont ID  
Sent By pvalenti Date 2021-10-06 Time 07:15 Rev Time 0.00
Received By pvalenti Date 2021-10-06 Time 07:14 Sent To  
Notes
2021-10-06 07:18:54SIGNATURE REVIEW DENIED:
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved