Plan Review Details - Permit 21090600
| Plan Review Stops For Permit 21090600 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-28 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-28 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-25 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-24 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-10-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-26 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-26 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-22 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-22 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2021-10-22 13:22:40 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NO OUTLET SHOWN IN BACK BATHROOM 210.52 | | | | | | KITCHEN COUNTER OUTLET SPACING IS MISSING AN OUTLET FOR | | | SPACIG ON COUNTER 210.52 | | | | | | PANEL SCHEDULE SHOWS 100A SUBFEEDER WITH #10S 215.5 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-25 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-24 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-09-25 09:45:08 | PLAN REVIEW / ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. PROVIDE AN UPDATED PANEL SCHEDULE. | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 2. PROVIDE A GFCI PROTECTED OUTLET FOR DISPOSAL. | | | E3902.10 | | | | | | 3. PROVIDE A GFCI PROTECTED OUTLET FOR MASTER BATH | | | LAV'S. | | | E3901.6 | | | | | | 4. PROVIDE MECHANICAL EXHAUST FOR HALL BATH. | | | R303.3BATHROOMS. | | | BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR | | | ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN | | | WINDOWS OF NOT LESS THAN 3 SQUARE FEET (0.3 M2), | | | ONE-HALF OF WHICH MUST BE OPENABLE. | | | EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE | | | ARTIFICIAL LIGHT AND A LOCAL EXHAUST SYSTEM ARE | | | PROVIDED. THE MINIMUM LOCAL EXHAUST RATES SHALL BE | | | DETERMINED IN ACCORDANCE WITH SECTION M1507. EXHAUST | | | AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE | | | OUTDOORS. | | | | | | 5. PROVIDE ARC-FAULT PROTECTION. | | | E3902.16 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE PROTECTED BY ANY OF THE FOLLOWING: | | | SEE E3902.16 [210.12(A)] | | | | | | 7. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-19 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-19 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2021-10-19 16:24:55 | 10/19/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-20 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-20 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2021-09-20 13:34:44 | 09/20/21 1ST GAS REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. WOULD YOU PLEASE HAVE A SIGNATURE ON THE ISOMETRIC | | | DRAWING OF THE PERSON DESIGNING THE SYSTEM, NOT IN | | | ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.001, FLORIDA STATUTE 471 PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.1 GENERAL. | | | | | | 2. THE DISTANCE PROVIDED DOES NOT ADD UP ON THE GAS | | | ISOMETRIC. WOULD YOU PLEASE CORRECT TO SHOW THE | | | DISTANCE FROM THE POINT OF THE DELIVERY GAS METER TO | | | THE MOST REMOTE OUTLET IN THE BUILDING AND/OR SYSTEM | | | PER THE 2020 FBC RES. SEC. G2413.4.1. | | | | | | 3. WOULD YOU PLEASE SUBMIT THE MANUFACTURER'S | | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR RANGE, | | | DRYER, AND TANK-LESS HEATER EQUIPMENT TO VERIFY | | | COMPLIANCE WITH 2020 FBC RES. SEC.G2408.1. | | | | | | 4. MOST TANK-LESS UNITS CALL FOR A 10.5" WATER COLUMN, | | | AND THE SERVICE METER DISCHARGES IS A 12" WATER COLUMN | | | REQUIRING A REGULATOR FOR THIS UNIT AS PER THE | | | MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS | | | INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE | | | APPROVED FOR OUTDOOR INSTALLATION PER THE 2020 FBC RES. | | | SEC. G2421.1 OR 410.1. | | | | | | 5. WOULD YOU PLEASE SHOW THE TYPE OF PIPE MATERIAL | | | BEING INSTALLED FOR EACH PIPE SIZE PER THE WPB | | | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 6. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION PER THE 2020 | | | FBC FG SECS. 402.2 AND 301.3. | | | | | | 7. WOULD YOU PLEASE SHOW AND LABEL ALL UNIONS IN FRONT | | | OF REGULATOR 1' OF EITHER SIDE PER THE 2020 FBC RES. | | | SEC G2421.2? | | | | | | 8. WOULD YOU PLEASE SHOW AND LABEL THE SHUT-OFF, AND | | | THEY SHALL BE ACCESSIBLE WITHOUT MOVING THE EQUIPMENT | | | PER THE 2020 FBC SEC. G2403 (202) GD, ACCESS. | | | | | | 9. WOULD YOU PLEASE SHOW AND LABEL ALL DRIP LEGS ON | | | EQUIPMENT EXCEPT FOR APPLIANCES, RANGE, DRYERS & OD | | | GRILLS PER THE 2020 FBC RES. SEC. G2419.2. | | | | | | 10. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2020 | | | FBC FG SEC. 304.1, 614.5 (CLOTHES DRYERS), OR 2020 FBC | | | RES. SEC. G2407.1 AND G2439.4 (CLOTHES DRYERS). | | | | | | 11. IF LOUVER DOORS ARE BEING FOR COMBUSTION FOR THE | | | DRYER? WOULD YOU PLEASE SHOW THE LOUVER(S) SIZE ON THE | | | PLANS PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS? | | | | | | 12. THE SHUT OFF INSIDE SHALL BE ACCESSIBLE WITHOUT | | | MOVING THE EQUIPMENT PER THE 2020 FBC SEC. G2403 (202) | | | GD, ACCESS. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2021-10-25 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2021-10-25 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-28 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-18 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-25 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-15 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-19 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-19 |
Time |
08:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-20 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-20 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2021-09-20 09:07:21 | 1) PLEASE SUBMIT A MECHANICAL PERMIT FOR THIS PROJECT | | | FROM A LICENSEDMECHANICAL CONTRACTOR. | | | | | | 2) THE SUBMITTED DRAWING SHOWS ALL BRANCH DUCTS AS 2", | | | BUT THE PROJECT INFORMATION SHEET INDICATES A VARIETY | | | OF BRANCH DUCT SIZES. PLEASE BE CONSISTENT. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-10-19 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-10-19 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2021-10-19 16:24:12 | 10/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-20 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-20 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2021-09-20 13:07:15 | 09/20/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLUMBING ISOMETRIC FOR MASTER BATH DOES NOT MATCH | | | THE LAYOUT, PLEASE SHOW THE BATHROOM GROUP ON ITS | | | SYSTEM AND NOT IN THE TRUNK LINE DISCHARGE AND PLEAS | | | SIZE THE DISCHARGE FOR THE WASHING MACHINE PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL | | | PLUMBING. | | | | | | 2. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE | | | ACCESSIBLE WITHOUT MOVING THE UNITS AND WITHIN REACH | | | PER THE 2017 FBC SEC. R 2903.9.3. | | | | | | 3. ON-HOUSE PLAN SHOWING THE LOCATION OF THE TANK-LESS | | | WATER HEATER SHOWS THE LOCATION AND DISTANCE OF ANY | | | OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER | | | HEATER. THE SITE OF THE WATER HEATER SHALL COMPLY WITH | | | THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE HOUSE | | | PLAN CAN BE HAND-DRAWN PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 4. HOT WATER LINES NOT IN CONDITION SPACE NEED TO BE | | | INSULATED WITH A MINIMUM R-3 PER THE 2020 FBC SEC. RE | | | 403.5.3. | | | | | | 5. VALVE UNDER LAV SHALL HAVE SHUT OFF IN AN ACCESSIBLE | | | LOCATION, VALVES SERVING INDIVIDUAL PLUMBING FIXTURES, | | | PLUMBING APPLIANCES, RISERS, AND BRANCHES SHALL BE | | | ACCESSIBLE PER THE 2020 P2903.9.3 FIXTURE VALVES AND | | | ACCESS. | | | | | | 6. THE SHOWER VALVES SHALL BE EQUIPPED WITH CONTROL | | | VALVES OF THE PRESSURE-BALANCE, THERMOSTATIC-MIXING, OR | | | COMBINATION PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE | | | TYPES WITH A HIGH LIMIT STOP IN ACCORDANCE WITH ASSE | | | 1016/ASME A112.1016/CSA B125.16. THE HIGH LIMIT STOP | | | SHALL BE SET TO LIMIT THE WATER TEMPERATURE TO EXCEED | | | 120 F. IN-LINE THERMOSTATIC VALVES SHALL NOT BE USED TO | | | COMPLY WITH THIS SECTION PER THE 2020 FBC R 2708.4 | | | SHOWER CONTROL VALVES. | | | | | | 7. THE HAND-HELD SHOWERS SHALL CONFORM TO ASME | | | A112.18.1/CSA B125.1. HAND-HELD SHOWERS SHALL PROVIDE | | | BACKFLOW PROTECTION IN ACCORDANCE WITH ASME | | | A112.18.1/CSA B125.1 OR SHALL BE PROTECTED AGAINST | | | BACKFLOW BY A DEVICE COMPLYING WITH ASME A112.18.3 PER | | | THE 2020 FBC R 2708.5 HAND SHOWERS. | | | | | | 8. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE | | | ACCESSIBLE WITHOUT MOVING THE UNITS AND WITHIN REACH | | | PER THE 2020 FBC SEC. R 2903.9.3. | | | | | | 9. ON SHEET P100 UNDER NOTES, IT REFERS TO THE 2017 FBC | | | CODE, AND THE CURRENT IS 2020. WOULD YOU PLEASE CORRECT | | | PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS? | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, DESCRIBING THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-25 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-25 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2021-10-25 13:01:24 | REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-25 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-24 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-09-25 09:08:30 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
|