Plan Review Details - Permit 21090600
Plan Review Stops For Permit 21090600
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-28 Cont ID  
Sent By cthroop Date 2021-10-28 Time 08:28 Rev Time 0.00
Received By cthroop Date 2021-10-28 Time 07:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 09:29 Rev Time 0.00
Received By cthroop Date 2021-09-24 Time 13:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By jleahy Date 2021-10-26 Time 11:11 Rev Time 0.00
Received By jleahy Date 2021-10-26 Time 11:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2021-10-22 Cont ID  
Sent By jleahy Date 2021-10-22 Time 13:20 Rev Time 0.00
Received By jleahy Date 2021-10-22 Time 12:50 Sent To  
Notes
2021-10-22 13:22:40ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO OUTLET SHOWN IN BACK BATHROOM 210.52
  
 KITCHEN COUNTER OUTLET SPACING IS MISSING AN OUTLET FOR
 SPACIG ON COUNTER 210.52
  
 PANEL SCHEDULE SHOWS 100A SUBFEEDER WITH #10S 215.5

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 09:29 Rev Time 0.00
Received By cthroop Date 2021-09-24 Time 13:31 Sent To  
Notes
2021-09-25 09:45:08PLAN REVIEW / ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. PROVIDE AN UPDATED PANEL SCHEDULE.
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
  
 2. PROVIDE A GFCI PROTECTED OUTLET FOR DISPOSAL.
 E3902.10
  
 3. PROVIDE A GFCI PROTECTED OUTLET FOR MASTER BATH
 LAV'S.
 E3901.6
  
 4. PROVIDE MECHANICAL EXHAUST FOR HALL BATH.
 R303.3BATHROOMS.
 BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR
 ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN
 WINDOWS OF NOT LESS THAN 3 SQUARE FEET (0.3 M2),
 ONE-HALF OF WHICH MUST BE OPENABLE.
 EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE
 ARTIFICIAL LIGHT AND A LOCAL EXHAUST SYSTEM ARE
 PROVIDED. THE MINIMUM LOCAL EXHAUST RATES SHALL BE
 DETERMINED IN ACCORDANCE WITH SECTION M1507. EXHAUST
 AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE
 OUTDOORS.
  
 5. PROVIDE ARC-FAULT PROTECTION.
 E3902.16 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION.
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE PROTECTED BY ANY OF THE FOLLOWING:
 SEE E3902.16 [210.12(A)]
  
 7. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By lcrespo Date 2021-10-19 Time 16:18 Rev Time 0.00
Received By lcrespo Date 2021-10-19 Time 16:04 Sent To  
Notes
2021-10-19 16:24:5510/19/21 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-09-20 Cont ID  
Sent By lcrespo Date 2021-09-20 Time 13:12 Rev Time 0.00
Received By lcrespo Date 2021-09-20 Time 13:12 Sent To  
Notes
2021-09-20 13:34:4409/20/21 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. WOULD YOU PLEASE HAVE A SIGNATURE ON THE ISOMETRIC
 DRAWING OF THE PERSON DESIGNING THE SYSTEM, NOT IN
 ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE
 61G15-23.001, FLORIDA STATUTE 471 PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.1 GENERAL.
  
 2. THE DISTANCE PROVIDED DOES NOT ADD UP ON THE GAS
 ISOMETRIC. WOULD YOU PLEASE CORRECT TO SHOW THE
 DISTANCE FROM THE POINT OF THE DELIVERY GAS METER TO
 THE MOST REMOTE OUTLET IN THE BUILDING AND/OR SYSTEM
 PER THE 2020 FBC RES. SEC. G2413.4.1.
  
 3. WOULD YOU PLEASE SUBMIT THE MANUFACTURER'S
 SPECIFICATION SHEETS/INSTALLATION MANUAL FOR RANGE,
 DRYER, AND TANK-LESS HEATER EQUIPMENT TO VERIFY
 COMPLIANCE WITH 2020 FBC RES. SEC.G2408.1.
  
 4. MOST TANK-LESS UNITS CALL FOR A 10.5" WATER COLUMN,
 AND THE SERVICE METER DISCHARGES IS A 12" WATER COLUMN
 REQUIRING A REGULATOR FOR THIS UNIT AS PER THE
 MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION PER THE 2020 FBC RES.
 SEC. G2421.1 OR 410.1.
  
 5. WOULD YOU PLEASE SHOW THE TYPE OF PIPE MATERIAL
 BEING INSTALLED FOR EACH PIPE SIZE PER THE WPB
 AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 6. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION PER THE 2020
 FBC FG SECS. 402.2 AND 301.3.
  
 7. WOULD YOU PLEASE SHOW AND LABEL ALL UNIONS IN FRONT
 OF REGULATOR 1' OF EITHER SIDE PER THE 2020 FBC RES.
 SEC G2421.2?
  
 8. WOULD YOU PLEASE SHOW AND LABEL THE SHUT-OFF, AND
 THEY SHALL BE ACCESSIBLE WITHOUT MOVING THE EQUIPMENT
 PER THE 2020 FBC SEC. G2403 (202) GD, ACCESS.
  
 9. WOULD YOU PLEASE SHOW AND LABEL ALL DRIP LEGS ON
 EQUIPMENT EXCEPT FOR APPLIANCES, RANGE, DRYERS & OD
 GRILLS PER THE 2020 FBC RES. SEC. G2419.2.
  
 10. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2020
 FBC FG SEC. 304.1, 614.5 (CLOTHES DRYERS), OR 2020 FBC
 RES. SEC. G2407.1 AND G2439.4 (CLOTHES DRYERS).
  
 11. IF LOUVER DOORS ARE BEING FOR COMBUSTION FOR THE
 DRYER? WOULD YOU PLEASE SHOW THE LOUVER(S) SIZE ON THE
 PLANS PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS?
  
 12. THE SHUT OFF INSIDE SHALL BE ACCESSIBLE WITHOUT
 MOVING THE EQUIPMENT PER THE 2020 FBC SEC. G2403 (202)
 GD, ACCESS.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2021-10-25 Cont ID  
Sent By amhamilt Date 2021-10-25 Time 15:39 Rev Time 0.00
Received By amhamilt Date 2021-10-25 Time 15:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-28 Cont ID  
Sent By cthroop Date 2021-10-28 Time 08:28 Rev Time 0.00
Received By cthroop Date 2021-10-18 Time 08:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 10:53 Rev Time 0.00
Received By cthroop Date 2021-09-15 Time 09:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By medwards Date 2021-10-19 Time 08:03 Rev Time 0.00
Received By medwards Date 2021-10-19 Time 08:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-09-20 Cont ID  
Sent By medwards Date 2021-09-20 Time 09:02 Rev Time 0.00
Received By medwards Date 2021-09-20 Time 09:02 Sent To  
Notes
2021-09-20 09:07:211) PLEASE SUBMIT A MECHANICAL PERMIT FOR THIS PROJECT
 FROM A LICENSEDMECHANICAL CONTRACTOR.
  
 2) THE SUBMITTED DRAWING SHOWS ALL BRANCH DUCTS AS 2",
 BUT THE PROJECT INFORMATION SHEET INDICATES A VARIETY
 OF BRANCH DUCT SIZES. PLEASE BE CONSISTENT.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By lcrespo Date 2021-10-19 Time 16:23 Rev Time 0.00
Received By lcrespo Date 2021-10-19 Time 15:52 Sent To  
Notes
2021-10-19 16:24:1210/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-09-20 Cont ID  
Sent By lcrespo Date 2021-09-20 Time 13:07 Rev Time 0.00
Received By lcrespo Date 2021-09-20 Time 13:07 Sent To  
Notes
2021-09-20 13:07:1509/20/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLUMBING ISOMETRIC FOR MASTER BATH DOES NOT MATCH
 THE LAYOUT, PLEASE SHOW THE BATHROOM GROUP ON ITS
 SYSTEM AND NOT IN THE TRUNK LINE DISCHARGE AND PLEAS
 SIZE THE DISCHARGE FOR THE WASHING MACHINE PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL
 PLUMBING.
  
 2. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING THE UNITS AND WITHIN REACH
 PER THE 2017 FBC SEC. R 2903.9.3.
  
 3. ON-HOUSE PLAN SHOWING THE LOCATION OF THE TANK-LESS
 WATER HEATER SHOWS THE LOCATION AND DISTANCE OF ANY
 OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER
 HEATER. THE SITE OF THE WATER HEATER SHALL COMPLY WITH
 THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE HOUSE
 PLAN CAN BE HAND-DRAWN PER THE WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 4. HOT WATER LINES NOT IN CONDITION SPACE NEED TO BE
 INSULATED WITH A MINIMUM R-3 PER THE 2020 FBC SEC. RE
 403.5.3.
  
 5. VALVE UNDER LAV SHALL HAVE SHUT OFF IN AN ACCESSIBLE
 LOCATION, VALVES SERVING INDIVIDUAL PLUMBING FIXTURES,
 PLUMBING APPLIANCES, RISERS, AND BRANCHES SHALL BE
 ACCESSIBLE PER THE 2020 P2903.9.3 FIXTURE VALVES AND
 ACCESS.
  
 6. THE SHOWER VALVES SHALL BE EQUIPPED WITH CONTROL
 VALVES OF THE PRESSURE-BALANCE, THERMOSTATIC-MIXING, OR
 COMBINATION PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE
 TYPES WITH A HIGH LIMIT STOP IN ACCORDANCE WITH ASSE
 1016/ASME A112.1016/CSA B125.16. THE HIGH LIMIT STOP
 SHALL BE SET TO LIMIT THE WATER TEMPERATURE TO EXCEED
 120 F. IN-LINE THERMOSTATIC VALVES SHALL NOT BE USED TO
 COMPLY WITH THIS SECTION PER THE 2020 FBC R 2708.4
 SHOWER CONTROL VALVES.
  
 7. THE HAND-HELD SHOWERS SHALL CONFORM TO ASME
 A112.18.1/CSA B125.1. HAND-HELD SHOWERS SHALL PROVIDE
 BACKFLOW PROTECTION IN ACCORDANCE WITH ASME
 A112.18.1/CSA B125.1 OR SHALL BE PROTECTED AGAINST
 BACKFLOW BY A DEVICE COMPLYING WITH ASME A112.18.3 PER
 THE 2020 FBC R 2708.5 HAND SHOWERS.
  
 8. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING THE UNITS AND WITHIN REACH
 PER THE 2020 FBC SEC. R 2903.9.3.
  
 9. ON SHEET P100 UNDER NOTES, IT REFERS TO THE 2017 FBC
 CODE, AND THE CURRENT IS 2020. WOULD YOU PLEASE CORRECT
 PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS?
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, DESCRIBING THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-25 Cont ID  
Sent By mpeterso Date 2021-10-25 Time 13:00 Rev Time 0.00
Received By mpeterso Date 2021-10-25 Time 13:00 Sent To  
Notes
2021-10-25 13:01:24REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-09-25 Cont ID  
Sent By cthroop Date 2021-09-25 Time 09:07 Rev Time 0.00
Received By cthroop Date 2021-09-24 Time 13:31 Sent To  
Notes
2021-09-25 09:08:30SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 1ST REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  