| Plan Review Stops For Permit 21090499 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-30 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-30 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2021-09-30 16:51:57 | ADDRESS APPROVED FOR SFH |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-08 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-08 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2022-04-08 15:56:03 | BUILDING AUDIT OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-08 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-07 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2022-03-08 13:10:53 | NEW SINGLE FAMILY RESIDENCE (R3) THIRD AUDIT. | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21090499 | | | | | | ORIGINAL COMMENT FROM PREVIOUS AUDIT: | | | 1- PROPOSED DRAINAGE & SITE PLAN ON SHEET SP-1: | | | BASED ON THE BOUNDARY SURVEY SUBMITTED AND PROPOSED | | | DRAINAGE PLAN THIS LOT WILL HAVE FINISH GRADE | | | ELEVATIONS A COUPLE OF FEET (3 FEET +/-) HIGHER THAN | | | EXISTING GRADES. PROPOSED DRAINAGE PLAN IS INCOMPLETE. | | | IT DOESN'T SHOW ANY RETAINING WALLS SHOWING HOW THIS | | | ELEVATED SOIL WILL BE SUPPORTED. SEC. 107.2.1.2 CITY | | | AMENDMENTS. ALSO, THE HOUSE FINISH FLOOR ELEVATION | | | SHOWN ON THE SURVEY AND PROPOSED DRAINAGE PLAN DON'T | | | MATCH. | | | NOTE: SEPARATE PERMIT WILL BE REQUIRED FOR THE | | | RETAINING WALLS. ALSO, KEEP IN CONSIDERATION THAT THERE | | | IS A DRAINAGE EASEMENT ON THE NORTH WEST SIDE OF THIS | | | LOT. COORDINATE WITH THE PERTINENT UTILITY TO AVOID | | | CONFLICTS/DELAYS. | | | | | | RESPONSE: | | | (1)REVISED DRAINAGE & SITE PLAN DOESN'T SHOW LOCATION | | | OF THE PROPOSED RETAINING WALLS. SEC. 107.2.5 CITY | | | AMENDMENTS. SEC. R401.3 FBC-RESIDENTIAL. | | | | | | (2)LOCATION OF THE RETAINING WALL IS NOT SHOWN. | | | TYPICALLY, THE RETAINING WALL IS LOCATED NEXT TO THE | | | PROPERTY LINES. IF THIS IS THE CASE, THEN THE PROPOSED | | | RETAINING WALL DETAIL IS SHOWING A FOOTING ENCROACHING | | | INTO THE NEIGHBOR'S PROPERTY. REVISE/CLARIFY AS | | | REQUIRED. SEC. 107.2.5 CITY AMENDMENTS. SEC. R401.3 | | | FBC-RESIDENTIAL. | | | | | | (3)RETAINING WALL DETAIL DOESN'T REFLECT A RETAINING | | | WALL. THE GRADE ELEVATION IS THE SAME ON BOTH SIDES OF | | | THE WALL. REVISE THE DETAIL AS REQUIRED TO REFLECT THE | | | ACTUAL PROPOSED CONDITIONS, INCLUDING THE GRADE | | | ELEVATION DIFFERENCE. AND, CLEARLY SPECIFY PROPOSED | | | WALL HEIGHT. | | | SEC. 107.2.5 CITY AMENDMENTS. SEC. R401.3 | | | FBC-RESIDENTIAL. | | | | | | (4)BOUNDARY SURVEY & SITE PLAN SUBMITTED SHOW A 12 FOOT | | | DRAINAGE EASEMENT ON THE WEST SIDE OF THE PROPERTY. | | | APPROVAL OF THE PROPOSED RETAINING WALL BY THE | | | PERTINENT ENTITIES (NPBCID AND THE POA) WILL BE | | | REQUIRED. | | | | | | (5)BOUNDARY SURVEY & SITE PLAN SUBMITTED SHOW A 25 FOOT | | | CONSERVATION EASEMENT ON THE NORTH AND EAST SIDE OF THE | | | PROPERTY. APPROVAL OF THE PROPOSED RETAINING WALL BY | | | THE PERTINENT ENTITIES (NPBCID AND THE POA) WILL BE | | | REQUIRED. | | | | | | (6) SEPARATE PERMIT REQUIRED FOR THE RETAINING WALL. | | | SINCE THE RETAINING WALL IS PROPOSED FOR THE HOUSE | | | CONSTRUCTION AND THIS WALL IS CONTINGENT ON THE NPBCID | | | AND THE POA APPROVAL, THEN THE RETAINING WALL PERMIT IS | | | REQUIRED AT THIS TIME TO AVOID CONFLICTS/DELAYS. | | | SEC. 105.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-02-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-04 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-04 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2022-02-04 14:14:55 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND AUDIT COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21090499 | | | | | | ORIGINAL COMMENT: | | | 1- MISSING LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY | | | AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | RESPONSE: | | | PROPOSED DRAINAGE & SITE PLAN ON SHEET SP-1: | | | BASED ON THE BOUNDARY SURVEY SUBMITTED AND PROPOSED | | | DRAINAGE PLAN THIS LOT WILL HAVE FINISH GRADE | | | ELEVATIONS A COUPLE OF FEET (3 FEET +/-) HIGHER THAN | | | EXISTING GRADES. PROPOSED DRAINAGE PLAN IS INCOMPLETE. | | | IT DOESN'T SHOW ANY RETAINING WALLS SHOWING HOW THIS | | | ELEVATED SOIL WILL BE SUPPORTED. SEC. 107.2.1.2 CITY | | | AMENDMENTS. ALSO, THE HOUSE FINISH FLOOR ELEVATION | | | SHOWN ON THE SURVEY AND PROPOSED DRAINAGE PLAN DON'T | | | MATCH. | | | NOTE: SEPARATE PERMIT WILL BE REQUIRED FOR THE | | | RETAINING WALLS. ALSO, KEEP IN CONSIDERATION THAT THERE | | | IS A DRAINAGE EASEMENT ON THE NORTH WEST SIDE OF THIS | | | LOT. COORDINATE WITH THE PERTINENT UTILITY TO AVOID | | | CONFLICTS/DELAYS. | | | | | | 2- SHEET A-1: | | | ORIGINAL COMMENT: | | | A)WIND DESIGN DATA SPECIFIES EXPOSURE "B". ACCORDING TO | | | SEC. R301.2.1.4.3 FBC-RESIDENTIAL THIS BUILDING IS | | | LOCATED IN EXPOSURE "C" NOT "B". REVISE EXPOSURE IN ALL | | | PLANS. | | | NOTE: REVISE DOORS, WINDOWS, ROOF DESIGN PRESSURES | | | ACCORDINGLY. AND, VERIFY ALL PRODUCT APPROVALS FOR | | | COMPLIANCE BEFORE SUBMITTAL. | | | | | | RESPONSE: | | | DOOR AND WINDOW SCHEDULES SHOW THE REVISED DESIGN | | | PRESSURES BUT THE DESIGN PRESSURES UNDER WIND DESIGN | | | DATA ON SAME SHEET WAS NOT REVISED. ALSO, CODE | | | INFORMATION ON SHEET A-2, A-3 AND S-2 STATE THAT THE | | | MAXIMUM PRESSURES FOR OPENINGS DOES NOT EXCEED +/- 59 | | | PSF. THIS IS A CONFLICT WITH THE REVISED DESIGN | | | PRESSURES SHOWN THE WINDOW/DOOR SCHEDULES. REVISE AS | | | REQUIRED TO MATCH. | | | CLARIFY WHY THE DESIGN PRESSURES FOR DOOR #13 ARE | | | -601.4? | | | DESIGN PRESSURES ON THE WINDOW/DOOR SCHEDULES STATES | | | "P.S.I". CLARIFY IF THIS IS A MISTAKE OR IF CALCULATED | | | PRESSURES ARE REALLY ON POUND PER SQUARE INCH. | | | TYPICALLY, DESIGN PRESSURES ARE GIVEN IN POUNDS PER | | | SQUARE FEET (P.S.F.). | | | | | | B)OK. | | | C)OK. | | | | | | ORIGINAL COMMENT: | | | D)CLARIFY THE PURPOSE COVERED PATIO DOOR #14 SHOWN | | | ADJACENT TO THE SLIDING GLASS DOORS BY THE KITCHEN | | | AREA. PROVIDE MORE INFORMATION: DOOR TYPE, DESIGN | | | PRESSURES, FRAMING, PRODUCT APPROVALS, ETC. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "THE PATIO DOOR IS | | | BEING INSTALLED FOR POSSIBLE FUTURE SCREEN ENCLOSURE | | | INSTALLATION". | | | THERE ARE 2 CONCERNS ABOUT THIS PATIO DOOR. FIRST, IF | | | THE PROPOSED USE IS A FUTURE SCREEN ENCLOSURE, THEN WHY | | | THIS DOOR (#14) IS SPECIFIED AS A METAL/GLASS FRENCH | | | DOOR?. AND SECOND, THE DESIGN PRESSURES FOR THIS DOOR | | | NEED TO BE REVISED BASED ON THE PROPOSED LOCATION. NOW | | | IS NOT A DOOR IN AN ENCLOSED STRUCTURE. SEC. 107.2.1.2 | | | CITY AMENDMENTS. | | | | | | 3- SHEET S-1: | | | A)OK. | | | B)OK. | | | | | | ORIGINAL COMMENT: | | | C)FRAMED BEARING WALL BETWEEN OFFICE AND LIVING ROOM IS | | | NOT CLEAR. FOUNDATION PLAN AND INTERIOR BEARING WALL | | | DETAIL 4/S-3 SPECIFY 2X6 SPF @16"O.C. HOW CAN YOU HAVE | | | 2X6 STUDS AT 16" O.C. IF PLANS SHOW 11-1/2" COLUMNS | | | SPACED AT 5'-0" AND 3'-0"? REVISE AS REQUIRED. PROVIDE | | | CORRECT DETAIL/SPECIFICATIONS FOR BEARING WALL IN THIS | | | AREA. SEC. R301.1 FBC-RESIDENTIAL. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | NOTE: SPECIFY TOP AND BOTTOM CONNECTIONS ALSO. INTERIOR | | | BEARING WALL DETAIL 4/S-3 ON SHEET S-3 SPECIFIES HUGHES | | | TP6X TOP & BOTTOM CONNECTORS. IT IS MY UNDERSTANDING | | | HUGHES IS OUT OF BUSINESS AND THIS CONNECTORS ARE NO | | | LONGER AVAILABLE. REVISE CONNECTORS AS REQUIRED OR | | | PROVIDE COPY OF CURRENT HUGHES CATALOG. | | | | | | RESPONSE: | | | THERE ARE NOT DETAILS OR SPECIFICATIONS FOR TOP AND | | | BOTTOM CONNECTIONS FOR THE REVISED (3)2X6 SUPPORTING | | | COLUMNS. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | D)DESIGN DATA NOTE #4 SHOWN UNDER FOUNDATION NOTES IS | | | MISSING INFORMATION. DESIGNER OF RECORD TO CLEARLY | | | SPECIFY ROOF LIVE AND DEAD LOADS (TOP AND BOTTOM | | | CHORDS), INCLUDING THE ATTIC LIVE LOAD AS REQUIRED BY | | | TABLE R301.5 FBC-RESIDENTIAL. NOTE: SEE FOOTNOTES "B" | | | AND "G". THIS HOUSE HAS TALL ATTICS. | | | | | | RESPONSE: | | | ONLY THE LIVE LOADS ARE SPECIFIED. ARCHITECT NEEDS TO | | | SPECIFY THE DEAD LOADS ALSO. CLEARLY SPECIFY ROOF LIVE | | | AND DEAD LOADS (TOP AND BOTTOM CHORDS) | | | | | | ORIGINAL COMMENT: | | | 4- SHEET S-2: THERE IS NOT INFORMATION FOR THE BEAMS AT | | | THE COVERED PATIO AND ABOVE ALL OPENINGS. PROVIDE BEAM | | | SCHEDULE AND COMPLETE DETAILS/ SPECIFICATIONS. SEC. | | | R301.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | NO BEAM SCHEDULE PROVIDED. ARCHITECT'S RESPONSE LETTER | | | STATES "THERE ARE TWO SETS OF BEAMS, ONE AT TRUSS | | | BEARING HEIGHTS, AND THE OTHER AT THE TOP OF | | | WINDOW/DOOR HEIGHT." | | | THESE RESPONSE, DOESN'T CLEARLY IDENTIFY THE BEAMS | | | ABOVE THE COVERED PATIO. | | | SPECIFICATIONS ON THE BUILDING CROSS SECTIONS ON SHEET | | | S-4 AND S-5 SPECIFY "(2)COURSE BONDBEAM W/ (1)#5 DIA. | | | EACH COURSE & POUR SOLID. ADD (2)30" LONG BENT BARS AT | | | CORNERS. FILL BEAMS W/ 2,500 P.S.I. GROUT (8" TO 11 | | | SUMP)". THESE ARE TYPICAL SPECIFICATIONS FOR THE HOUSE | | | BONDBEAM. THE BOND BEAM IS THE HORIZONTAL STRUCTURAL | | | ELEMENT THAT IS PART OF A MASONRY WALL ASSEMBLY TO | | | PROVIDE HORIZONTAL STRENGTH TO THAT MASONRY WALL. | | | TYPICALLY, POURED CONCRETE BEAMS OR PRECAST LINTELS ARE | | | SPECIFIED ON COVERED PORCHES. | | | IT IS NOT CLEAR, BUT BASED ON THE ARCHITECT'S RESPONSE | | | LETTER IT LOOKS LIKE THE ARCHITECT IS PROPOSING TO USE | | | THIS BOND BEAM AS THE BEAM TO CARRY ALL THE LOADS ON | | | THE COVERED PATIO AREA. | | | IF THIS IS THE CASE, THEN THERE IS A SAFETY STRUCTURAL | | | CONCERN BASED ON THE BEAM SPANS AND DEAD LOADS ON THE | | | COVERED PATIO. PROVIDE CALCULATIONS SHOWING THAT THE | | | PROPOSED BOND BEAM IS ADEQUATE TO SUPPORT ALL THE LOADS | | | ON THE COVERED PATIO. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | 5-SHEET S-3: | | | A)OK. | | | | | | ORIGINAL COMMENT: | | | B)REVISE WINDOW/DOOR BUCK DETAIL. 1X4 BUCKS DON'T | | | PROVIDE FULL SUPPORT TO THE DOOR FRAME AS REQUIRED BY | | | SEC. R609.7.2.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. DETAIL NO REVISED. | | | | | | ORIGINAL COMMENT: | | | 6- REVISE ROOF SHEATHING NAILING SPACING. ROOF | | | SHEATHING NEEDS TO BE NAILED AT 4 INCHES O.C. IN THE | | | FIELD AND EDGES AS REQUIRED BY SEC. R803.2.3.1 AND | | | TABLE R803.2.3.1 FBC-RESIDENTIAL. | | | NOTE: REVISE SPECIFICATIONS ON ALL PLANS AND WALL | | | SECTIONS TO AVOID CONFLICTS/DELAYS. | | | | | | RESPONSE: | | | SPECIFICATIONS ON THE BUILDING CROSS SECTIONS ON SHEET | | | S-4 AND S-5 SPECIFY "PLYWD. SECURED TO TRUSS TOP CHORD | | | W/ 8D RING SHANK NAILS (0.113" DIA.MIN.) @ 6"O.C. | | | THROUGHOUT (ENTIRE ROOF IS AS ZONE 3) 4" O.C. @ ENDS". | | | THESE SPECIFICATIONS DON'T SPECIFY 4" O.C. AS REQUIRED | | | BY TABLE TABLE R803.2.3.1 FBC-RESIDENTIAL. REVISE AS | | | REQUIRED. | | | NOTE: AFTER A SECOND REVIEW OF THE ROOF SHEATHING | | | SPECIFICATIONS IT WAS NOTED THAT THE PLYWOOD THICKNESS | | | WAS NOT SPECIFIED. PLEASE SPECIFY PLYWOOD THICKNESS | | | ALSO. | | | | | | 7-OK. | | | 8-OK. | | | 9-OK. | | | | | | 10- PRODUCT APPROVALS | | | ORIGINAL COMMENT: | | | A)GARAGE DOOR NOA 20-0922.36 IS FOR DOORS WITH A | | | MAXIMUM WIDTH OF 9'-0". GARAGE DOORS SPECIFIED ON PLANS | | | ARE BIGGER. NEED ANOTHER PRODUCT APPROVAL FOR SPECIFIED | | | LARGER SIZE. FAC 61G20-3.001. | | | | | | RESPONSE: | | | SECTIONAL GARAGE DOOR NOA 20-0922.15 SUBMITTED. THE | | | DESIGN PRESSURES OF THIS GARAGE DOOR DON'T MEET THE | | | DESIGN PRESSURES CALCULATED BY THE ARCHITECT OF RECORD | | | ON SHEET A-1 DOOR SCHEDULE. NEED PRODUCT APPROVAL FOR | | | DOOR MEETING OR EXCEEDING THE CALCULATED DESIGN | | | PRESSURES. | | | | | | ORIGINAL COMMENT: | | | B)MISSING PRODUCT APPROVALS FOR ALL TYPES OF WINDOWS | | | SHOWN ON PLANS. FAC 61G20-3.001. | | | | | | RESPONSE: | | | RESPONSE LETTER STATES THAT THE PRODUCT APPROVALS WERE | | | SUBMITTED. THERE ARE NO WINDOWS PRODUCT APPROVALS | | | UPLOADED TO PROJECTDOX. | | | | | | C) OK. | | | D) OK. | | | | | | 11- OK. | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-30 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-30 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2021-12-30 10:55:44 | NEW SINGLE FAMILY RESIDENCE (R3) AUDIT COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21090499 | | | | | | 1- MISSING LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY | | | AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | 2- SHEET A-1: | | | A)WIND DESIGN DATA SPECIFIES EXPOSURE "B". ACCORDING TO | | | SEC. R301.2.1.4.3 FBC-RESIDENTIAL THIS BUILDING IS | | | LOCATED IN EXPOSURE "C" NOT "B". REVISE EXPOSURE IN ALL | | | PLANS. | | | NOTE: REVISE DOORS, WINDOWS, ROOF DESIGN PRESSURES | | | ACCORDINGLY. AND, VERIFY ALL PRODUCT APPROVALS FOR | | | COMPLIANCE BEFORE SUBMITTAL. | | | | | | B)FLOOR PLAN SHOWS A FIRE PIT INSIDE THE COVERED PATIO. | | | THERE IS NOT INFORMATION ABOUT THIS FIRE PIT. TYPICALLY | | | FIRE PITS ARE BUILT OUTSIDE AND AWAY FROM THE BUILDING. | | | THERE IS A CONCERN ABOUT FIRE GIVEN THE LOCATION AND | | | TYPE OF FIRE PIT TO BE BUILT/INSTALLED. ARCHITECT OF | | | RECORD NEEDS TO PROVIDE COMPLETE INFORMATION SHOWING | | | THAT PROPOSED INSTALLATION WILL NOT CREATE A FIRE | | | HAZARD. PROVIDE COMPLETE INFORMATION, INCLUDING | | | MANUFACTURER'S SPECS, FIRE PIT DETAILS/SPECIFICATIONS, | | | CLEARANCES, ETC. SEC. 101.3 CITY AMENDMENTS. SEC. | | | 107.2.1.2 CITY AMENDMENTS. | | | | | | C)CLARIFY WHY ONLY THE WALLS ADJACENT TO BEDROOM #4 AND | | | STORAGE ROOM ARE HATCHED TO BE INSULATED , WHILE THE | | | WALL ADJACENT TO THE HALLWAY IS NOT? HALLWAY WALL IS | | | ALSO SEPARATING A/C AREA FROM NON A/C AREA. SEC. R103.2 | | | FBC-ENERGY CONSERVATION. | | | | | | D)CLARIFY THE PURPOSE COVERED PATIO DOOR #14 SHOWN | | | ADJACENT TO THE SLIDING GLASS DOORS BY THE KITCHEN | | | AREA. PROVIDE MORE INFORMATION: DOOR TYPE, DESIGN | | | PRESSURES, FRAMING, PRODUCT APPROVALS, ETC. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | 3- SHEET S-1: | | | A)THERE ARE NO DETAILS/SPECIFICATIONS FOR COVERED PATIO | | | STRUCTURAL COLUMNS. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | B)ENTRY PORCH CONSTRUCTION IS MISSING INFORMATION. | | | THERE IS NO FOOTING FOR THE EXTERIOR WALL SHOWN AT THE | | | BOTTOM OF THE ENTRY PORCH. THERE ARE NO | | | DETAILS/SPECIFICATIONS FOR THE CONSTRUCTION OF THIS | | | WALL EITHER. THERE ARE NO DETAILS/SPECIFICATIONS FOR | | | THE CONSTRUCTION OF THE ENTRY FACADE. DETAIL 1/S-5 | | | DOESN'T PROVIDE COMPLETE INFORMATION. PROVIDE COMPLETE | | | EXTERIOR WALL SECTIONS AND DETAILS/SPECIFICATIONS. | | | SPECIFY ALL FRAMING MEMBERS AND CONNECTORS. SEC. R301.1 | | | FBC-RESIDENTIAL. SEC. 107.3.5.3 CITY AMENDMENTS. | | | | | | C)FRAMED BEARING WALL BETWEEN OFFICE AND LIVING ROOM IS | | | NOT CLEAR. FOUNDATION PLAN AND INTERIOR BEARING WALL | | | DETAIL 4/S-3 SPECIFY 2X6 SPF @16"O.C. HOW CAN YOU HAVE | | | 2X6 STUDS AT 16" O.C. IF PLANS SHOW 11-1/2" COLUMNS | | | SPACED AT 5'-0" AND 3'-0"? REVISE AS REQUIRED. PROVIDE | | | CORRECT DETAIL/SPECIFICATIONS FOR BEARING WALL IN THIS | | | AREA. SEC. R301.1 FBC-RESIDENTIAL. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | NOTE: SPECIFY TOP AND BOTTOM CONNECTIONS ALSO. INTERIOR | | | BEARING WALL DETAIL 4/S-3 ON SHEET S-3 SPECIFIES HUGHES | | | TP6X TOP & BOTTOM CONNECTORS. IT IS MY UNDERSTANDING | | | HUGHES IS OUT OF BUSINESS AND THIS CONNECTORS ARE NO | | | LONGER AVAILABLE. REVISE CONNECTORS AS REQUIRED OR | | | PROVIDE COPY OF CURRENT HUGHES CATALOG. | | | | | | D)DESIGN DATA NOTE #4 SHOWN UNDER FOUNDATION NOTES IS | | | MISSING INFORMATION. DESIGNER OF RECORD TO CLEARLY | | | SPECIFY ROOF LIVE AND DEAD LOADS (TOP AND BOTTOM | | | CHORDS), INCLUDING THE ATTIC LIVE LOAD AS REQUIRED BY | | | TABLE R301.5 FBC-RESIDENTIAL. NOTE: SEE FOOTNOTES "B" | | | AND "G". THIS HOUSE HAS TALL ATTICS. | | | | | | E)SOIL BEARING PRESSURE IS NOT CLEAR. DESIGN DATA NOTE | | | #4 SHOWN UNDER FOUNDATION NOTES AND FOUNDATION NOTE #8 | | | SPECIFIES 3,000 PSF SOIL BEARING PRESSURE, WHILE | | | FOUNDATION NOTE #1 ON SAME FOUNDATION NOTES SPECIFIES | | | 2,500 PSF. REVISE AS REQUIRED TO MATCH. SEC. R301.1 | | | FBC-RESIDENTIAL. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 4- SHEET S-2: THERE IS NOT INFORMATION FOR THE BEAMS AT | | | THE COVERED PATIO AND ABOVE ALL OPENINGS. PROVIDE BEAM | | | SCHEDULE AND COMPLETE DETAILS/ SPECIFICATIONS. SEC. | | | R301.1 FBC-RESIDENTIAL. | | | | | | 5-SHEET S-3: | | | A)GARAGE BUCK DETAIL IS MISSING INFORMATION. THERE IS | | | NOT DETAIL 6/A-10. PROVIDE COMPLETE STRUCTURAL BUCK | | | DETAIL. SPECIFY ANCHOR TYPE, SIZE, SPACING AND | | | EMBEDMENT. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | B)REVISE WINDOW/DOOR BUCK DETAIL. 1X4 BUCKS DON'T | | | PROVIDE FULL SUPPORT TO THE DOOR FRAME AS REQUIRED BY | | | SEC. R609.7.2.1 FBC-RESIDENTIAL. | | | | | | 6- REVISE ROOF SHEATHING NAILING SPACING. ROOF | | | SHEATHING NEEDS TO BE NAILED AT 4 INCHES O.C. IN THE | | | FIELD AND EDGES AS REQUIRED BY SEC. R803.2.3.1 AND | | | TABLE R803.2.3.1 FBC-RESIDENTIAL. | | | NOTE: REVISE SPECIFICATIONS ON ALL PLANS AND WALL | | | SECTIONS TO AVOID CONFLICTS/DELAYS. | | | | | | 7- PLANS DON'T PROVIDE DETAIL/SPECIFICATIONS FOR | | | CEILING CONSTRUCTION AT COVERED PORCH. | | | SEC. R703.1.2.1 FBC-RESIDENTIAL. | | | NOTE: COORDINATE WITH ITEM #2(B) ABOVE. | | | | | | 8- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ARCHITECT IS | | | SPECIFYING R-20 SPRAY ISO. INSULATION. PROVIDE ICC | | | EVALUATION REPORT FOR THE FOAM INSULATION TO VERIFY | | | COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. | | | NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN | | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 9- ENERGY CALCULATIONS: | | | A)THE ENERGY FORM R405-2020 IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY | | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | | PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION. | | | | | | B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | | | | C)NUMBER OF BEDROOMS IS INCORRECT. REVISE ITEM #4. SEC. | | | R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | D)DOORS INFORMATION ON PAGE 3 DOESN'T MATCH PLANS. | | | WHERE ARE THE TWO SW INSULATED 3X8 DOORS AND THE NW 3X8 | | | WOOD DOOR? SEE PLANS AND PRODUCT APPROVALS AND REVISE | | | AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY | | | CONSERVATION. | | | | | | E)WINDOWS INFORMATION ON PAGE 4 DOESN'T MATCH PLANS. | | | ORIENTATION OF WINDOWS DON'T MATCH PLANS. SEE SURVEY | | | AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY | | | CONSERVATION. | | | | | | F) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY | | | CONSERVATION. | | | | | | 10- PRODUCT APPROVALS | | | A)GARAGE DOOR NOA 20-0922.36 IS FOR DOORS WITH A | | | MAXIMUM WIDTH OF 9'-0". GARAGE DOORS SPECIFIED ON PLANS | | | ARE BIGGER. NEED ANOTHER PRODUCT APPROVAL FOR SPECIFIED | | | LARGER SIZE. FAC 61G20-3.001. | | | | | | B)MISSING PRODUCT APPROVALS FOR ALL TYPES OF WINDOWS | | | SHOWN ON PLANS. FAC 61G20-3.001 | | | | | | C) WINDOW AND DOOR MULLIONS NOA 20-0814.10 NEED TO | | | SPECIFY MULLION SIZES TO BE USED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES. SEC. R301.2.1 | | | FBC-RESIDENTIAL. | | | | | | D)ROOF TILE NOA 16-0711.05 DOESN'T SPECIFY TILE | | | FASTENING METHOD. UNABLE TO VERIFY IF PROPOSED | | | INSTALLATION WILL MEET THE REQUIRED UPLIFT. SEC. | | | R301.2.1 FBC-RESIDENTIAL. | | | NOTE: IF PROPOSED INSTALLATION IS SCREWS, THEN SPECIFY | | | SIZE AND NUMBER OF SCREWS. IF SPECIFYING ROOF TILE | | | ADHESIVE, THEN SPECIFY PADDY SIZE AND PRODUCT APPROVAL | | | IS REQUIRED. | | | | | | 11-DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-03-08 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-03-08 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-02-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-02-07 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-02-07 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2022-02-07 15:19:37 | ELECTRIC AUDIT FAILED | | | 1) ELECTRICAL RISER DIAGRAM DETAILS GENERATOR TRANSFER | | | SWITCHES ON LOAD SIDE OF BRANCH CIRCUIT PANELS WITHOUT | | | DETAILING HOW SYSTEM WILL BE USED TO TRANSFER FROM | | | NORMAL TO STANDBY POWER. PLEASE CORRECT WITH PROPER | | | ELECTRICAL RISER DIAGRAM. NEC 215.5 IT APPEARS THE | | | ORIGINAL DRAWING WAS CHANGED, UNNECESSARILY AS IT WAS | | | CORRECT, EXCEPT FOR THE COMMENTS BELOW | | | 2) ELECTRICAL RISER DIAGRAM DETAILS AN EQUIPMENT | | | GROUNDING CONDUCTOR BETWEEN THE METER AND THE FIRST | | | MEANS OF DISCONNECT. PLEASE REMOVE THIS DETAIL TO | | | COMPLY WITH NEC 250.30 | | | 3) ELECTRICAL RISER DIAGRAM DETAILS A #4 CU GROUNDING | | | ELECTRODE CONDUCTOR FOR A 300-AMP SERVICE WITH 350 MCM | | | SERVICE CONDUCTORS. PROPER GROUNDING ELECTRODE | | | CONDUCTOR SIZED AS PER NEC 250.66 SHOULD BE A #2 CU | | | CONDUCTOR. PLEASE CORRECT AS NOTED | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-29 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-29 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2021-12-29 15:13:50 | FAILED ELECTRICAL AUDIT FOR THE FOLLOWING | | | 1) INCORRECT SIZE GROUNDING ELECTRODE CONDUCTOR NEC | | | 250.66 | | | 2) INCORRECT SIZE MAIN BONDING JUMPER CONDUCTOR NEC | | | 250.102 | | | 3) INCORRECT LOAD CALCULATION, MANY FASTENED IN PLACE | | | APPLIANCES NOT LISTED NEC 220.82(B)(3) | | | 4) INCORRECT LOAD CALCULATION, HEAT IS LISTED AT 20KW | | | FOR (3) 10KW HEAT STRIPS. COOLING SHOULD BE USED | | | INSTEAD PER NEC 220.82? ?THE LARGEST OF THE SIX | | | SELECTIONS. COOLING @ 100% LISTED AT 9.6KW EACH | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2023-01-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-13 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-13 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-02-03 |
Time |
06:36 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-02-03 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2022-02-03 06:37:17 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT | | | BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND | | | PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENT TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-08 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-08 |
Time |
14:35 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-08 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-02 |
Time |
07:20 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
F |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-01 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-28 |
Time |
12:32 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2022-02-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-02-19 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-02-16 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-02-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-02-07 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-02-07 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-01-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-01-27 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-01-25 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-01-26 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-26 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-24 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-30 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-07 |
Time |
17:48 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-29 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-17 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-25 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-15 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-04-13 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-04-08 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2022-04-13 09:01:59 | RECEIPT MU-2022-16113 - $12,372.98 PAID | | 2022-04-08 15:48:32 | 4/8/22 EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-10-26 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2021-10-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-26 16:12:58 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION WILL OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-02-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-02 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-02 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2022-02-02 16:40:14 | MECHANICAL AUDIT ONLY. ME |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-29 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-29 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2021-12-29 08:49:32 | MECHANICAL AUDIT: | | | | | | 1) SHEET M.1: THE DRYER EXHAUST DETAIL CALLS FOR A BIRD | | | SCREEN. THE SCREEN IS NOT PERMITTED ON A DRYER EXHAUST. | | | FBC RES M1502.3 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-02-03 |
Time |
05:49 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-02-03 |
Time |
05:32 |
Sent To |
|
|
| Notes |
| 2022-02-03 05:50:51 | PLUMBING AUDIT ONLY ON E-1. LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-12-29 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-12-29 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2021-12-29 08:37:26 | ADUIT APPROVED BY PLUMBING |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
9 |
Status |
P |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-08 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-08 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
8 |
Status |
P |
Date |
2022-03-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-04 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-04 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
7 |
Status |
F |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-01 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-01 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2022-03-01 16:42:14 | FS553.791 PRIVATE PROVIDER PLAN REVIEW COMPLIANCE | | | AFFIDAVIT. | | | | | | 1- PRIVATE PROVIDER PLAN REVIEW COMPLIANCE AFFIDAVIT | | | DATED 2/23/2022: | | | A)NOA 18-0502.03 IS A ROOFING UNDERLAYMENT NOT AND ALUM | | | WINDOW WALL SYSTEM AS SPECIFIED ON THE AFFIDAVIT. | | | REVISE AS REQUIRED TO MATCH. | | | | | | 2- PRIVATE PROVIDER PLAN REVIEW COMPLIANCE AFFIDAVIT | | | DATED 2/21/2022: | | | A)DRAWING M.1 UPLOADED TO PROJECTDOX HAS A REVISION #2 | | | DATED 1/17/22. AFFIDAVIT STATES 9/27/2021. REVISE AS | | | REQUIRED TO MATCH M.1 DRAWING. | | | | | | B)DRAWING M.2 UPLOADED TO PROJECTDOX HAS A REVISION #1 | | | DATED 9/27/21. AFFIDAVIT STATES DATED 1/17/2022. REVISE | | | AS REQUIRED TO MATCH M.2 DRAWING. | | | | | | C)HVAC LOAD CALCULATIONS DON'T HAVE THE PREPARATION | | | DATE. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
6 |
Status |
F |
Date |
2022-02-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-02-19 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-02-19 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2022-02-19 09:56:29 | FS553.791 AFFIDAVIT DOES NOT REFLECT CORRECT DATE(S). | | | FOR INSTANCE, SITE PLAN IS DATED 2/9/22. CHECK ALL. | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
5 |
Status |
P |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-01 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-01 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2022-02-01 09:00:51 | COMMENTS HAVE BEEN ADDRESSED. PP AFFIDAVIT AUDIT HAS | | | BEEN APPROVED. ME |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
4 |
Status |
F |
Date |
2022-01-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-26 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-26 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2022-01-26 15:46:02 | PRIVATE PROVIDER PLAN REVIEW COMPLIANCE AFFIDAVIT AUDIT | | | ONLY | | | | | | | | | 3RD CYCLE AUDIT FBC-2020 MECHANICAL | | | PERMIT-21090499 | | | | | | CODES IN EFFECT: | | | | | | | | | PLAN REVIEW AUDIT RESULTS: DENIED. | | | | | | 1) PRIVATE PROVIDER PLAN REVIEW COMPLIANCE AFFIDAVIT | | | ARE NOT SIGNED BY THE PRIVATE PROVIDER. | | | | | | 2) THE ENERGY CALCULATIONS ARE NOT LISTED ON THE | | | PRIVATE PROVIDER PLAN REVIEW COMPLIANCE AFFIDAVIT. | | | | | | 3) THE REVISED PRIVATE PROVIDER PLAN REVIEW COMPLIANCE | | | AFFIDAVIT INDICATES THAT THE BOUNDARY SURVEY & SITE | | | PLAN SHOULD HAVE A DATE 1/5/2022, THE DRAWING SUBMITTED | | | HAS A DATE OF AUGUST 18, 2021. PLEASE SHOW THAT THE | | | PRIVATE PROVIDER HAS REVIEWED THE LATEST VERSION. | | | | | | 4) THE REVISED PRIVATE PROVIDER PLAN REVIEW COMPLIANCE | | | AFFIDAVIT INDICATES THAT THE M-2 SHEET SHOULD HAVE A | | | DATE OF 1/17/2022, THE SHEET SUBMITTED HAS A REVISED | | | DATE OF 9/27/2021. PLEASE SHOW THAT THE PRIVATE | | | PROVIDER HAS REVIEWED THE LATEST VERSION. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
3 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-12-07 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-12-07 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2021-12-07 15:56:00 | PRIVATE PROVIDER AFFIDAVIT REVIEW APPROVED. | | | THERE ARE NO PRODUCT APPROVAL DOCUMENTS IN THE PLANS | | | AND THE AFFIDAVIT FROM THE PRIVATE PROVIDER DOES NOT | | | INCLUDE SUCH | | | ADDITIONAL AFFIDAVIT WILL BE REQUIRED WHEN THE PRODUCT | | | APPROVALS ARE SUBMITTED | | | | | | RICHARD GATHRIGHT | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-11-29 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-11-29 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2021-11-29 15:40:09 | PRIVATE PROVIDER PLAN REVIEW NOT APPROVED | | | THERE ARE ADDITIONAL A AND S PAGES UP LOADED. A | | | DRAWINGS HAVE DIFFERENT DATE THAN WHAT IS ON THE | | | AFFIDAVIT OF CODE COMPLIANCE. NO PRODUCT APPROVALS ARE | | | INCLUDED IN THE CERTIFICATE OF COMPLIANCE. WHEN WILL | | | PRODUCT APPROVALS BE SUBMITTED. AN ADDITIONAL AFFIDAVIT | | | WILL BE REQUIRED AT THAT TIME | | | PLEASE COORDINATE THE UPLOADED PLANS WITH THE PRIVATE | | | PROVIDER AND RESUBMIT | | | | | | RICHARD GATHROGHT | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-10-25 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-10-25 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2021-10-25 16:08:52 | PRIVATE PROVIDER PLAN AUDIT FAILED | | | DOES NOT APPEAR THAT THE ENTIRE SET OF PLANS WERE | | | SUBMITTED FOR THE PERMIT APPLICATION. | | | SHEETS SP-1, A-1, A-2, A-3, AND BOUNDRY SURVEY | | | SUBMITTED. | | | NO CERTIFICATE OF CODE COMPLIANCE SUBMITTED | | | | | | RICHARD GATHRIGHT | | | ASSISTANT BUILDING OFFICIAL | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-08 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-08 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2022-03-08 14:03:22 | ROOF TILE NOA 16-0711.05. | | | TILE ADHESIVE FL6332-R9. | | | UNDERLAYMENT NOA 18-0502.03. | | | UNDERLAYMENT NOA 21-0602.14 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-02-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-04 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-04 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-30 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-30 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2021-12-30 11:06:54 | 1- PRODUCT APPROVALS | | | A)ROOF TILE NOA 16-0711.05 DOESN'T SPECIFY TILE | | | FASTENING METHOD. UNABLE TO VERIFY IF PROPOSED | | | INSTALLATION WILL MEET THE REQUIRED UPLIFT. SEC. | | | R301.2.1 FBC-RESIDENTIAL. | | | NOTE: IF PROPOSED INSTALLATION IS SCREWS, THEN SPECIFY | | | SIZE AND NUMBER OF SCREWS. IF SPECIFYING ROOF TILE | | | ADHESIVE, THEN SPECIFY PADDY SIZE AND PRODUCT APPROVAL | | | IS REQUIRED. | | | | | | B) MISSING PRODUCT APPROVALS FOR ROOF TILE HIP & RIDGE | | | SUPPORT TO BE USED. FAC 61G20-3.001. | | | | | | 2-DESIGNER OF RECORD TO REVIEW/APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-08 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-08 |
Time |
18:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-04-08 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-04-08 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2022-04-08 16:59:28 | 04/08/22 TALKED TO TIM DORNBLASER. HE WILL EMAIL ME THE | | | REPORT WITH THE DIGITAL SIGNATURE. JG. | | | | | | | | | | | | SIGNATURE REVIEW: | | | | | | ORIGINAL COMMENT: | | | 1- SOIL TEST REPORT NEEDS THE ORIGINAL SEAL AND | | | SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR | | | PUBLIC RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH ENGINEER'S DIGITAL | | | SIGNATURE OR PROVIDE HARD COPY WITH ENGINEER'S ORIGINAL | | | SEAL AND SIGNATURE. | | | | | | RESPONSE: | | | NOT ADDRESSED. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-08 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-08 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2022-03-08 13:55:26 | THIRD SIGNATURE REVIEW: | | | | | | ORIGINAL COMMENT: | | | 1- SOIL TEST REPORT NEEDS THE ORIGINAL SEAL AND | | | SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR | | | PUBLIC RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH ENGINEER'S DIGITAL | | | SIGNATURE OR PROVIDE HARD COPY WITH ENGINEER'S ORIGINAL | | | SEAL AND SIGNATURE. | | | | | | RESPONSE: | | | NOT ADDRESSED. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-02-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-04 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-04 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2022-02-04 15:15:00 | SECOND SIGNATURE REVIEW: | | | | | | ORIGINAL COMMENT: | | | 1- SOIL TEST REPORT NEEDS THE ORIGINAL SEAL AND | | | SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR | | | PUBLIC RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH ENGINEER'S DIGITAL | | | SIGNATURE OR PROVIDE HARD COPY WITH ENGINEER'S ORIGINAL | | | SEAL AND SIGNATURE. | | | | | | RESPONSE: | | | NOT ADDRESSED. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-30 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-30 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2021-12-30 10:53:22 | 1- SOIL TEST REPORT NEEDS THE ORIGINAL SEAL AND | | | SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR | | | PUBLIC RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH ENGINEER'S DIGITAL | | | SIGNATURE OR PROVIDE HARD COPY WITH ENGINEER'S ORIGINAL | | | SEAL AND SIGNATURE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
vbriglia |
Date |
2022-04-05 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-04-05 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-02-18 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-02-18 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-01-25 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-01-25 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-01-25 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-10-22 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-10-22 |
Time |
|
Sent To |
I |
|
| Notes |
|
|