| Plan Review Stops For Permit 21090496 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-10 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-09 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-03 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-03 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2021-11-03 16:12:41 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1.PROVIDE DESIGN PRESSURES FOR NEW ROOFING PER FIGURE | | | R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 2.PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER DESIGN | | | PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | PLEASE UPLOAD YOUR DOCUMENTS TO PROJECT DOX. | | | DO NOT E-MAIL DOCUMENTS TO THE PLANS EXAMINER. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-10 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-10 |
Time |
07:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-07 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-07 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2021-12-07 15:43:10 | PASSED ELECTRICAL REVIEW | | | NEW SUBMITTALS CONTAIN ELECTRICAL RISER DIAGRAM AND | | | PANEL SCHEDULE |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-10-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-06 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-06 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2021-10-06 16:32:54 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED RISER DIAGRAM SHOWING LOCATION OF PANEL AND ALSO | | | NEED A PANEL SCHEDULE. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-24 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-24 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2021-09-24 16:11:57 | 09/24/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-10-07 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-10-07 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-10 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-09 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-03 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-14 |
Time |
07:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-10 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-10 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-20 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-20 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2021-09-20 17:23:45 | 1) PLEASE SHOW THE ANCHORAGE OF THE CONDENSING UNIT | | | WILL COMPLY WITH FBC RES M1307.2 | | | | | | 2) PLEASE SHOW THE CONDENSATE PIPE AND THE TERMINATION | | | LOCATION. FBC RES M1411.3 | | | | | | 3) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-24 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-24 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2021-09-24 16:12:37 | 09/24/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-10 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-09 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-03 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-03 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2021-11-03 16:06:20 | ROOFING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER | | | BARRIER PER FBC R905.1.1. | | | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL | | | CONFORM TO THE APPLICABLE STANDARDS? AND SHALL BE | | | APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION | | | R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | PLEASE UPLOAD YOUR DOCUMENTS TO PROJECT DOX. | | | DO NOT E-MAIL DOCUMENTS TO THE PLANS EXAMINER. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-10 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-10 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-20 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-20 |
Time |
17:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-10-07 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-10-07 |
Time |
11:50 |
Sent To |
|
|
| Notes |
|
|