| 2021-09-15 14:48:45 | RE-ROOF BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21090440 |
| | |
| | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| | SHALL COMPLY WITH THE MATERIALS AND METHODS |
| | REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| | |
| | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL2533-R25 |
| | SUBMITTED: |
| | SELECTED ASSEMBLY W-85 ON PAGE 16 OF 74 DOESN'T MEET |
| | THE DESIGN PRESSURES FOR ALL ROOF ZONES AS REQUIRED BY |
| | SEC. 1609.1 FBC-BUILDING. PROVIDE SIGNED AND SEALED RAS |
| | 117 CALCULATIONS AS REQUIRED BY LIMITATION 5.7.2 OF |
| | PRODUCT APPROVAL SUBMITTED. |
| | |
| | 2- SEPARATE PERMIT FOR MECHANICAL ROOFING EQUIPMENT MAY |
| | BE REQUIRED. |
| | SEC. 102.8 CITY AMENDMENTS: EXISTING MECHANICAL |
| | EQUIPMENT. AN AGENCY OR LOCAL GOVERNMENT MAY NOT |
| | REQUIRE THAT EXISTING MECHANICAL EQUIPMENT LOCATED ON |
| | OR ABOVE THE SURFACE OF A ROOF BE INSTALLED IN |
| | COMPLIANCE WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE EXCEPT DURING REROOFING WHEN THE |
| | EQUIPMENT IS BEING REPLACED OR MOVED AND IS NOT IN |
| | COMPLIANCE WITH THE PROVISIONS OF THE FLORIDA BUILDING |
| | CODE RELATING TO ROOF-MOUNTED MECHANICAL UNITS. |
| | |
| | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN |
| | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| | AMENDMENTS. UPDATE VALUATION TO INCLUDE ALL COSTS OR |
| | PROVIDE COPY OF SIGNED CONTRACTS INCLUDING DESIGN |
| | PROFESSIONAL FEES (IF ANY)FOR BUILDING OFFICIAL |
| | APPROVAL. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |