Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-09-30 Cont ID  
Sent By cpuell Date 2021-09-30 Time 16:56 Rev Time 0.00
Received By cpuell Date 2021-09-30 Time 16:56 Sent To  
Notes
2021-09-30 16:57:10ADDRESS APPROOVED FOR PLANS SUBMITTED ON 9.8.21 SHOULD
 THE LAYOUT CHANGE A REVIEW WILL BE REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-02-04 Cont ID  
Sent By cthroop Date 2022-02-04 Time 08:37 Rev Time 0.00
Received By cthroop Date 2022-02-04 Time 05:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-01-27 Cont ID  
Sent By cthroop Date 2022-01-27 Time 13:45 Rev Time 0.00
Received By cthroop Date 2022-01-27 Time 11:01 Sent To  
Notes
2022-01-27 13:53:47BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: PRODUCT APPROVAL DO NOT MATCH THE PP COMPLIANCE
 AFFIDAVIT SUBMITTED:
  
 1. PRODUCT APPROVALS ON AFFIDAVIT BUT NOT SUBMITTED FOR
 REVIEW.
 NOA 19-1112.20
 NOA 20-0901.07
  
 2. PRODUCT APPROVAL SUBMITTED FOR REVIEW BUT NOT ON
 AFFIDAVIT:
 NOA 20-0901.06
  
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-20 Cont ID  
Sent By cthroop Date 2021-12-20 Time 10:52 Rev Time 0.00
Received By cthroop Date 2021-12-20 Time 09:45 Sent To  
Notes
2021-12-20 10:57:43BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. NOA'S 20-0901.07 AND 20-0713.02 ARE FOR NON-IMPACT
 RATED DEVICES. SUBMIT AN NOA FOR IMPACT RATED DEVOCES
 OR SUBMIT A SCHEDULE FOR OPENING PROTECTIVE DEVICES OS
 ASSEMBLIES.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 2. PRODUCT APPROVAL FL22513-R3 IS MISSING THE COVER
 SHEET.
 THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE
 VERSION, AND STATUS, FBC R 301.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-01-27 Cont ID  
Sent By cthroop Date 2022-01-27 Time 13:45 Rev Time 0.00
Received By cthroop Date 2022-01-27 Time 13:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-12-20 Cont ID  
Sent By mpeterso Date 2021-12-20 Time 08:55 Rev Time 0.00
Received By mpeterso Date 2021-12-20 Time 13:15 Sent To  
Notes
2021-12-20 09:01:55ELECTRIC PLAN REVIEW FAILED
 1) ELECTRIC PLAN SHOWS (2) 200-AMP PANELS CONFLICTING
 WITH RISER AND PANEL SCHEDULES SHOWING (1) 200-AMP AND
 (1) 150-AMP PANELS. FBC 107.2
 2) NO LOCATION SHOWN FOR METER/MAIN SHOWN ON ELECTRICAL
 RISER. FBC 107.2
 3) NO LOCATION SHOWN FOR IRRIGATION PUMP DETAILED IN
 PANEL SCHEDULES. FBC 107.2
 4) INCORRECT SIZING OF WIRE AND BREAKER FEEDING AIR
 HANDLER. NEC 210.19
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2022-02-07 Cont ID  
Sent By cthroop Date 2022-02-07 Time 13:12 Rev Time 0.00
Received By cthroop Date 2022-02-03 Time 17:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-01-27 Cont ID  
Sent By lmarchan Date 2022-01-27 Time 13:57 Rev Time 0.00
Received By lmarchan Date 2022-01-26 Time 10:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-01-21 Cont ID  
Sent By shill Date 2022-01-21 Time 10:48 Rev Time 0.00
Received By shill Date 2022-01-19 Time 08:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-01-10 Cont ID  
Sent By shill Date 2022-01-10 Time 12:26 Rev Time 0.00
Received By shill Date 2022-01-06 Time 06:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-12-20 Cont ID  
Sent By cthroop Date 2021-12-20 Time 10:57 Rev Time 0.00
Received By cthroop Date 2021-11-24 Time 11:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-24 Cont ID  
Sent By lmarchan Date 2021-11-24 Time 10:31 Rev Time 0.00
Received By lmarchan Date 2021-11-16 Time 11:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-06 Cont ID  
Sent By lmarchan Date 2021-11-06 Time 17:28 Rev Time 0.00
Received By lmarchan Date 2021-10-05 Time 07:50 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-02-04 Cont ID  
Sent By lmarchan Date 2022-02-04 Time 10:28 Rev Time 0.00
Received By lmarchan Date 2022-01-11 Time 07:46 Sent To  
Notes
2022-02-04 10:06:16RECEIPT MU-2022-001831 - $2491.56 PAID
2022-01-11 07:46:451/11/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-11-06 Cont ID  
Sent By lmarchan Date 2021-11-06 Time 17:27 Rev Time 0.00
Received By lmarchan Date 2021-11-06 Time 17:27 Sent To  
Notes
2021-11-06 17:27:59PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION WILL OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-12-13 Cont ID  
Sent By medwards Date 2021-12-13 Time 15:57 Rev Time 0.00
Received By medwards Date 2021-12-13 Time 15:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-01-27 Cont ID  
Sent By cthroop Date 2022-01-27 Time 13:39 Rev Time 0.00
Received By cthroop Date 2022-01-27 Time 11:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-12-20 Cont ID  
Sent By cthroop Date 2021-12-20 Time 10:51 Rev Time 0.00
Received By cthroop Date 2021-12-20 Time 09:44 Sent To  
Notes
2021-12-20 10:52:46BUILDING PLAN PLUMBING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. MASTER BATH LAV MISSING FROM PLUMBING REISER
 DIAGRAHM.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 6 Status P Date 2022-02-07 Cont ID  
Sent By cthroop Date 2022-02-07 Time 13:12 Rev Time 0.00
Received By cthroop Date 2022-02-07 Time 13:09 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 5 Status F Date 2022-01-26 Cont ID  
Sent By medwards Date 2022-01-26 Time 17:39 Rev Time 0.00
Received By medwards Date 2022-01-26 Time 17:39 Sent To  
Notes
2022-01-26 17:40:00PRIVATE PROVIDER AFFIDAVIT AUDIT ONLY
  
 5TH CYCLE AFFIDAVIT AUDIT FBC-2020 MECHANICAL
 PERMIT-21090353
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE REVIEWER FOUND AND UPLOADED THE COVER SHEET FOR
 THE 3 PAGE DOCUMENT FOR AN EXTERIOR DOOR THAT IS IN THE
 SUBMITTALS BUT IT IS NOT SHOWN ON THE PRIVATE PROVIDER
 AFFIDAVIT SHEET. IN THE FUTURE PLEASE PROVIDE THE COVER
 SHEET FOT THE PRODUCT APPROVALS.
  
 2) PLEASE MAKE SURE THE PP AFFIDAVIT AND THE SUBMITTALS
 MATCH, PLEASE CHECK THE LAST TWO NUMBERS OF THESE NOA'S
 AND SUBMIT THE ONE YOU INTEND TO USE. NOA 20-901.07 IS
 ON THE PRIVATE PROVIDER AFFIDAVIT SHEET BUT THIS
 DOCUMENT IS NOT IN THE SUBMITTED DOCUMENTS. THERE IS A
 NOA 20-0901.06 IN THE SUBMITTALS BUT IT ISN?T ON THE
 PRIVATE PROVIDER AFFIDAVIT SHEET.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status F Date 2022-01-21 Cont ID  
Sent By shill Date 2022-01-21 Time 10:46 Rev Time 0.00
Received By shill Date 2022-01-21 Time 10:46 Sent To  
Notes
2022-01-21 10:48:09****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FS553.791(1)H PRODUCT APPROVALS NOT CONSISTENT WITH
 AFFIDAVIT/UPLOAD. 20-0813.07 WAS UPLOADED, NOT INCLUDED
 IN THE AFFIDAVIT. ESR1826 EVALUATION REPORT WAS NOT
 UPLOADED. 20-0713.02 IS ON AFFIDAVIT, NOT PROVIDED.
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status F Date 2022-01-10 Cont ID  
Sent By shill Date 2022-01-10 Time 12:21 Rev Time 0.00
Received By shill Date 2022-01-10 Time 12:21 Sent To  
Notes
2022-01-10 12:26:04FS553.791 A NEW SURVEY WHICH HAS THE SAME DATE AS
 PREVIOUS SURVEY, BUT WITH CHANGES, WAS SUBMITTED.
  
 HAVE THE SURVEYOR MODIFY THE SURVEY WITH A DATE SO THE
 DATE THAT THIS WAS REVISED IS CLEAR.
  
 SUBMIT A NEW AFFIDAVIT FROM THE PRIVATE PROVIDER WHICH
 INCLUDES THE NEW SURVEY/DRAINAGE PLAN.
  
 NOTE THAT IT DOES NOT APPEAR THAT PLAN REVIEW COMMENTS
 WERE ADDRESSED. BEFORE RESUBMITTING, HAVE THE PRIVATE
 PROVIDER ACKNOWLEDGE THAT THEY HAVE RECEIVED ALL
 COMMENTS.
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2021-12-03 Cont ID  
Sent By shill Date 2021-12-03 Time 17:03 Rev Time 0.00
Received By shill Date 2021-12-03 Time 17:03 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-10-13 Cont ID  
Sent By dbattles Date 2021-10-13 Time 08:29 Rev Time 0.00
Received By dbattles Date 2021-10-13 Time 08:29 Sent To  
Notes
2021-10-13 08:31:40PRIVATE PROVIDER FOR REVIEW AND INSPECTIONS
 CREDENTIALS -OK
 REVIEW OF AFFIDAVIT TO BE COMPLETED AFTER OTHER AGENCY
 APPROVALS.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2021-12-20 Cont ID  
Sent By cthroop Date 2021-12-20 Time 10:50 Rev Time 0.00
Received By cthroop Date 2021-12-20 Time 09:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-01-27 Cont ID  
Sent By cthroop Date 2022-01-27 Time 13:39 Rev Time 0.00
Received By cthroop Date 2022-01-27 Time 11:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-12-20 Cont ID  
Sent By cthroop Date 2021-12-20 Time 10:50 Rev Time 0.00
Received By cthroop Date 2021-12-20 Time 09:45 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-11-22 Cont ID  
Sent By ajones Date 2021-11-22 Time 11:35 Rev Time 0.00
Received By ajones Date 2021-11-22 Time 11:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-11-05 Cont ID  
Sent By rthermid Date 2021-11-05 Time 10:34 Rev Time 0.00
Received By ajones Date 2021-11-05 Time 10:34 Sent To  
Notes
2021-11-05 10:36:3711/5/21- FAILED. PLEASE PROVIDE A SURVEY/SITE PLAN
 INDICATING THE SETBACKS.
  