Plan Review Details - Permit 21090291
| Plan Review Stops For Permit 21090291 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-26 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-26 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-13 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-13 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2021-09-13 11:27:24 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE STRUCTURAL PAD DETAIL FOR GENERATOR. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE DESIGN WIND LOADS OF GENERATOR PER R301; FBC | | | CHPT. 16; ASCE 7-16. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | FBC 107.3.5.1.(8) PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-CHAPTER 16. | | | 1609.1.1DETERMINATION OF WIND LOADS. | | | WIND LOADS ON EVERY BUILDING OR STRUCTURE SHALL BE | | | DETERMINED IN ACCORDANCE WITH CHAPTERS 26 TO 30 OF ASCE | | | 7. WIND SHALL BE ASSUMED TO COME FROM ANY HORIZONTAL | | | DIRECTION AND WIND PRESSURES SHALL BE ASSUMED TO ACT | | | NORMAL TO THE SURFACE CONSIDERED. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-09-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-26 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-25 |
Time |
05:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-13 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-13 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2021-09-13 11:22:23 | PLAN REVIEW ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: ELECTRICAL RISER AND LOAD CALC'S | | | | | | 1. CONTRACTOR SHALL SIGN PLANS. | | | SEE COMMENTS UNDER SIGNATURE REVIEW. | | | | | | 2. INCLUDE GENERATOR CONTROLLER CIRCUT CONDUCTORS ON | | | RISER DIAGRAHM. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-26 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-23 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-17 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-09-08 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-09-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-26 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-25 |
Time |
05:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-13 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-13 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2021-09-13 11:01:02 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: ELECTRICAL RISER AND CALCULATIONS | | | | | | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE | | | THEIR PRINTED NAME AND SIGNATURE ON PLAN SHEETS UNDER | | | THEIR AUTHORITY. | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | | | | 2. EITHER UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL | | | WITH SIGNATURE OF DESIGNER AS APPLICABLE; USE THE | | | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT OR DROP | | | OFF (OR MAIL) ONE PAPER ORIGINAL WITH CONTRACTORS/O/B | | | SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-09-17 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-09-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-09-17 13:58:39 | ZONING PASSED WITH THE FOLLOWING PROVISO: | | | | | | 1.) GENERATOR SHALL BE SCREENED FROM VIEW AT THE FRONT | | | (OSPREY TRACE) AND SIDE PROPERTY LINES. | | | | | | | | | | | | |
|
|
|