| Plan Review Stops For Permit 21090284 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-11-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-24 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-03 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-03 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2021-11-03 07:34:56 | CANOPY | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | 1) DRAWING E 1 SHOWS 2017 FBC - CODE IN EFFECT CHANGED | | | ON 1/1/2021 - PLEASE REVISE THE PLANS TO SHOW THE CODE | | | IN EFFECT (2020 FBC USING ASCE 7-16) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-01 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-01 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2021-10-01 15:46:24 | CANOPY | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | 1) CODE IN EFFECT CHANGED ON 1/1/2021 - PLEASE REVISE | | | THE PLANS TO SHOW THE CODE IN EFFECT (2020 FBC USING | | | ASCE 7-16) |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-10 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-11-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-18 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-11-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-03 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-25 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-01 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-07 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-11-19 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-19 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2021-11-19 07:47:49 | PAPER PLANS LABELED "E1,E2 AND E3" HAVE BEEN SUBMITTED | | | AND APPROVED WITH A WET SIGNATURE AND SEAL |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-10-25 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-25 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-25 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2021-10-25 13:52:25 | IT APPEARS AS THAT ON 9/7/2021 (1) PAPER PLAN WAS | | | SUBMITTED, (E-3 SECTIONS) ,THAT HAD THE REQUIRED SEAL | | | AND WET SIGNATURE.THEN ON 10/25/2021, (2) ADDITIONAL | | | PAPER PLANS WERE SUBMITTED. THESE PLANS DO NOT HAVE AN | | | ENGINEERS SEAL AND ONLY HAVE A COPY OF A DIGITAL | | | SIGNATURE OF DORTHY BANZANSZEWSKI P.E. | | | PAPER PLANS REQUIRE AN ENGINEERS SEAL WITH A WET | | | SIGNATURE AS NOTED BELOW. PLEASE FOLLOW THE | | | INSTRUCTIONS BELOW TO CORRECT THIS ISSUE. | | | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | | SIGNED. | | | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-09-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-07 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-07 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2021-09-07 18:29:03 | | | | REVIEW OF SIGNATURE AND SEAL ON PAPER PLANS AND | | | DOCUMENTS APPROVED AND PLANS ROUTED TO STORAGE. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-23 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-09-23 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2021-09-23 |
Time |
|
Sent To |
|
|
| Notes |
|
|