Plan Review Details - Permit 21090274
Plan Review Stops For Permit 21090274
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-01-25 Cont ID  
Sent By rmcdouga Date 2022-01-25 Time 17:23 Rev Time 0.00
Received By rmcdouga Date 2022-01-25 Time 17:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-10-05 Cont ID  
Sent By rmcdouga Date 2021-10-05 Time 08:08 Rev Time 0.00
Received By rmcdouga Date 2021-10-05 Time 08:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-02-02 Cont ID  
Sent By jleahy Date 2022-02-02 Time 15:14 Rev Time 0.00
Received By jleahy Date 2022-02-02 Time 15:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-10-04 Cont ID  
Sent By ppetty Date 2021-10-04 Time 11:31 Rev Time 0.00
Received By ppetty Date 2021-10-04 Time 10:51 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2021-09-23 Cont ID  
Sent By lcrespo Date 2021-09-23 Time 14:54 Rev Time 0.00
Received By lcrespo Date 2021-09-23 Time 14:54 Sent To  
Notes
2021-09-23 14:55:39GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT
 BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND
 PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-03 Cont ID  
Sent By lmarchan Date 2022-02-03 Time 07:16 Rev Time 0.00
Received By lmarchan Date 2022-01-13 Time 08:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-05 Cont ID  
Sent By rmcdouga Date 2021-10-05 Time 08:10 Rev Time 0.00
Received By rmcdouga Date 2021-09-08 Time 06:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-01-14 Cont ID  
Sent By lcrespo Date 2022-01-14 Time 09:21 Rev Time 0.00
Received By lcrespo Date 2022-01-14 Time 09:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-09-23 Cont ID  
Sent By lcrespo Date 2021-09-23 Time 14:49 Rev Time 0.00
Received By lcrespo Date 2021-09-23 Time 14:32 Sent To  
Notes
2021-09-23 14:51:3309/23/21 1ST POOL REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. WOULD YOU PLEASE SUBMIT TOTAL DYNAMIC HEAD
 CALCULATIONS FOR THE MAXIMUM SYSTEM FLOW COMPONENTS? IT
 REQUIRES THAT THE MAXIMUM SYSTEM FLOW RATE DOES NOT
 EXCEED THE LISTED MAXIMUM FLOW RATE OF THE SUCTION
 OUTLET FITTING ASSEMBLY (DRAIN COVER). THE TDH
 CALCULATIONS MUST INCLUDE ALL THE SYSTEM COMPONENTS
 INCLUDING SUCTION AND RETURN PIPING, FITTINGS, VALVES,
 HEATER, FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS
 EXCEPT THE PUMP PER THE ANSI/APSP/ICC 7 - 2015 SECS.
 4.4.9, 4.4.9.1 MAXIMUM SYSTEM FLOW RATE?UNSECURED
 CONTROL SYSTEMS.
  
 2. WOULD YOU PLEASE SUBMIT A COPY OF THE POOL PUMP
 CURVE. IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS
 SPECIFIC TO THE PUMP BEING INSTALLED ON THIS POOL. THIS
 IS NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE
 TDH CALCULATIONS PER THE ANSI/APSP/ICC 7 - 2015 SECS.
 4.4.9, 4.4.9.1.
  
 3. A SUB GAS PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-01-25 Cont ID  
Sent By rmcdouga Date 2022-01-25 Time 17:25 Rev Time 0.00
Received By rmcdouga Date 2022-01-25 Time 17:25 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-09-08 Cont ID  
Sent By ccole Date 2021-09-08 Time 12:13 Rev Time 0.00
Received By ccole Date 2021-09-08 Time 12:13 Sent To  
Notes
2021-09-08 12:14:441ST REVIEW DIGITAL SIGNATURE
 PERMIT- 21090274
 9/8/2021
  
 CODES IN EFFECT:
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE POOL PLANS- SHEETS 1, 2, 3, & 4 HAVE SCANNED OR
 COPIED DIGITAL SIGNATURES AND SEALS THAT ARE NOT
 CAPABLE OF BEING VERIFED. PLANS THAT ARE PREPARED BY A
 FL. LICENSED ENGINEER THAT ARE TRANSMITTED
 ELECTRONICALLY SHALL BEAR DIGITAL SIGNATURES AND SEALS
 THAT CAN BE VERIFIED AS THIRD-PARTY CERTIFIED USING
 SOFTWARE SUCH AS THE ADOBE READER SYSTEM WHICH IS USED
 IN THE WPB BUILDING DEPT. PLEASE SUBMIT ORIGINAL
 DIGITALLY SIGNED AND SEALED PLANS- FL. STATUTE 471.025
 AND SECTION 61G15-23.005 FAC.
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
  
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-01-31 Cont ID  
Sent By asangele Date 2022-01-31 Time 16:14 Rev Time 0.00
Received By asangele Date 2022-01-31 Time 16:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By llouie Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2021-09-14 10:51:27*************************ZONING
 REVIEW****************************
  
 THE DIMENSIONS FOR THE SETBACKS FOR THE POOL ARE
 DIFFICULT TO READ ON THE SURVEY.
  
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
  
  