Plan Review Details - Permit 21090208
| Plan Review Stops For Permit 21090208 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-17 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-17 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2021-09-17 12:39:25 | PARCEL READDRESSED, PARCEL ADDRESS 717 NEW JERSEY ST, | | | SOUTH BLDG 717 NEW JERSEY ST # 1 AND BORTH BLDG 717 NEW | | | JERSEY ST # 2 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-09 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-09 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2021-09-09 08:54:54 | WHICH BUILDING IS THE WORK TO BE DONE, NORTH OR SOUTH? | | | THE NORTH BUILDING HAS A HALF ADDRESS WHICH WILL NEED | | | TO BE READDRESSED. PLEASE HAVE THE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 TO READDRESS THE | | | HALF ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-09-29 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-09-29 |
Time |
18:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-22 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-22 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2021-09-22 09:46:08 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NOA NO. 19-0617.07 HAS BEEN SUPERCEDED BY NOA NO. | | | 20-0902.20. SUBMIT THE CURRENT NOA. FAC 61G20-3.001 | | | | | | 2) THE SYSTEM THAT WAS SELECTED ON PAGE 41 OF NOA NO. | | | 19-0617.07 HAS A MAXIMUM DESIGN PRESSURE OF -75.0 PSF | | | WHICH WILL NOT MEET THE REQUIRED COMPONENT AND CLADDING | | | PRESSURES FOR THIS ROOF. THE PRODUCT APPROVAL ALLOWS | | | ENHANCED FASTENING TO INCREASE THE DESIGN PRESSURE BUT | | | REQUIRES THE CALCULATIONS TO BE SIGNED AND SEALED BY A | | | FLORIDA LICENSED DESIGN PROFESSIONAL. SUBMIT THE | | | REQUIRED SIGNED AND SEALED ENHANCED FASTENING | | | CALCULATIONS. FBC 107.2.1.2 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2021-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-22 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-22 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2021-09-22 09:20:41 | ONLY RE-ROOFING THE FLAT ROOF PART OF THE REAR | | | BUILDING. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-09-29 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-09-23 |
Time |
09:52 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-09-22 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-09-20 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |