| Plan Review Stops For Permit 21090053 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-25 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-25 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2022-02-25 11:16:08 | PARCEL 623 AVON RD, 623 AVON RD # 1 MAIN BLDG AND 623 | | | AVON RD # 2 REAR BLDG |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2022-02-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-08 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-08 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2022-02-08 15:32:30 | RESPOSE LETTER STATED THAT THE OWNER HAD CONTACTED | | | ADDRESSING BUT THEY HAVE NOT. PLEASE HAVE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-30 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-30 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2021-09-30 14:29:04 | PLEASE COORDINATE WITH [email protected] FOR THE HABITABLE | | | SPACE AKA NEW GUEST COTTAGE, TO BE GIVEN AN ADDRESS. | | | ALL ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND OR OTHER | | | HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE SECONDARY | | | ADDRESS NUMBER PER CITY'S ADDRESSING POLICY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-11 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-11 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-05 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-05 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2021-11-05 09:08:02 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: A SEPERATE PERMIT IS REQUIRED FOR THE | | | CABANA/GARAGE STRUCTURE. | | | | | | 1. CORRECT GOVERNING CODES ON PAGE A1 TO 2020FBC 7TH | | | ED. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE A COPY OF THE BOUNDRY LINE SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. PROVIDE SETBACK DEMENSIONS TO SITE PLAN. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 4. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | | | | 5. PLACE EXT. WALL INSULATION TYPE AND R VALUE ON PLAN. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 6. PROVIDE AN ENERGY SUBMITTAL. | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | FBC EC-R101.5.1.1.2 BUILDING THERMAL ENVELOPE | | | ALTERNATIVE. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 7. PROVIDE A ROOF FRAMING PLAN. | | | 7A) .PROVIDE DESIGN PRESSURES FOR NEW ROOFING PER | | | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | 7B) .PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER | | | DESIGN PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | PLEASE UPLOAD YOUR DOCUMENTS TO PROJECT DOX. DO NOT | | | E-MAIL DOCUMENTS TO THE PLANS EXAMINER. | | | | | | PLAN REVIEW COMMENTS: | | | YOU CAN CHECK THE STATUS OF YOUR SUBMITTAL AND VIEW THE | | | PLAN REVIEW COMMENTS BY FOLLOWING THE INSTRUCTIONS | | | BELOW: | | | COPY AND PASTE THE FOLLOWING LINK INTO ANY INTERNET | | | BROWSER. | | | | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STAT | | | US.ASPX | | | | | | OPEN THE ONESTOPSHOP WEB-SITE FOR PERMIT STATUS | | | | | | ? ENTER IN THE PERMIT NUMBER ? SELECT SEARCH | | | ? LEFT CLICK ON PERMIT NUMBER | | | ? UNDER PERMIT INFORMATION SELECT PLAN REVIEWS TAB | | | ? ANY OPEN REVIEW STOP MEANS THAT REVIEW IS STILL | | | PENDING. | | | ? CLICK ON THE LATEST REVIEW NAME AND NUMBER TO REVIEW | | | COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-02-23 |
Time |
19:48 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-02-23 |
Time |
18:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-10-07 |
Time |
21:31 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-10-07 |
Time |
20:19 |
Sent To |
|
|
| Notes |
| 2021-10-07 20:52:52 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. MINIMUM GEC SIZE FOR COLD WATER PIPE IS #4 CU NOT | | | NUMBER #6. PROVIDE CORRECTION. NEC 250.66 | | | | | | 2. 100AMP PANEL FOR COTTAGE DOES NOT SHOW MAIN BREAKER. | | | MAIN BREAKER REQUIRED FOR SEPARATE STRUCTURE BECAUSE | | | THERE ARE MORE THAN 6 THROWS OF THE HAND. NEC 225.32 & | | | 225.33 | | | | | | 3. SEPARATE PERMIT IS REQUIRED FOR COTTAGE STRUCTURE. | | | FBC 105.1 | | | | | | 4. NOTE ON PLAN STATES AIC RATING WILL BE SUPPLIED BY | | | FINAL INSPECTION. THIS IS NOT PERMITTED. AIC RATING | | | WILL BE REQUIRED BEFORE PERMIT ISSUANCE. PROVIDE | | | CORRECTION | | | | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | | | | 5. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | | RE E3607.3 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-02-23 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-02-23 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-28 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-18 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-11 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-08 |
Time |
07:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-05 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-13 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-03-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-23 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-03-11 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2022-03-23 12:44:55 | RECEIPT MU-20220-012236 - $546.52 PAID | | 2022-03-11 13:30:30 | 3/11/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-05 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-05 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2021-11-05 07:27:25 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-28 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-17 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-17 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2022-02-17 11:19:32 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21090053 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THIS REVIEW IS FOR THE MAIN HOUSE ONLY. COTTAGE PERMIT | | | NUMBER IS 22010888. THE CABANA WOULD BE CONSIDERED A | | | HABITABLE SPACE AND MUST BE CONDITIONED. PLEASE SUBMIT | | | MECHANICAL DRAWINGS FOR THIS CABANA. THE ELECTRICAL | | | SHEET CALLS FOR A MINI SPLIT, IF THIS IS TO BE USED FOR | | | THE CABANA PLEASE PROVIDE THE MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS ALONG WITH THE MECHANICAL DRAWING. | | | | | | 1) THE SQUARE FOOTAGE SUBMITTED FOR THE MAIN HOUSE IN | | | THE ENERGY CALCULATIONS AND THE MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS DO NOT MATCH. PLEASE CORRECT THIS. | | | | | | 2) PLEASE PROVIDE DUCT SIZES ON DUCTS FROM AHU TO FIRST | | | FLOOR AND DUCT FROM AHU TO TRANSFER BOX ABOVE THE | | | MASTER BATH. FBC 107.2.1 | | | | | | 3) PLEASE PROVIDE A DETAIL OF THE ANCHORING OF THE | | | CONDENSING UNIT. FBC RES M1307.2 | | | | | | 4) PLEASE SHOW THE CONDENSATE PIPING MATERIAL, SIZE AND | | | TERMINATION LOCATION. FBC RES M1411.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-23 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-23 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2021-09-23 09:14:05 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21090053 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A MECHANICAL DRAWING SHOWING ALL OF | | | THE MECHANICAL WORK BEING COMPLETED UNDER THIS PROJECT | | | BOTH FOR THE MAIN HOUSE AND THE NEW GUEST COTTAGE. FBC | | | 107.2.1 | | | | | | 2) PLEASE PROVIDE A MECHANICAL EQUIPMENT SIZING | | | CALCULATION FOR THE NEW KITCHEN ADDITION AND FOR THE | | | NEW GUEST COTTAGE. FBC EC R403.7.1 | | | | | | 3) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THE NEW | | | KITCHEN ADDITION AND FOR THE NEW GUEST COTTAGE. FBC EC | | | R101.5.1.1.2 | | | | | | 4) PLEASE PROVIDE THE CFM?S OF THE NEW KITCHEN HOOD. | | | FBC RES M1503.4 | | | | | | 5) A SEPARATE PERMIT WILL BE REQUIRED FOR EACH | | | STRUCTURE. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-02-15 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-02-15 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-30 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-30 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2021-09-30 14:19:58 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21090053 | | | 9/30/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET EP-1: BASED ON THE RISER DIAGRAM IT APPEARS | | | THAT THE WATER CLOSET IN THE MASTER BATH IS NOT BEING | | | VENTED PROPERLY. IF YOU ARE WET VENTING THE FIXTURE, | | | THE DRAIN SHALL CONNECT HORIZONTALLY TO THE BRANCH | | | DRAIN IN THE DIRECTION OF FLOW- SECTION P3108.1 FBC | | | RES. | | | | | | 2) EP-1: IT APPEARS THE WASHING MACHINE ON THE 2ND | | | FLOOR IS PART OF A STACKABLE WASHER/DRYER COMBO UNIT. | | | PLEASE SHOW THE LOCATIONS OF THE SHUT OFF VALVES FOR | | | THE WASHING MACHINE TO VERIFY THEY WILL IN AN | | | ACCESSIBLE LOCATION- P2903.9.3 FBC RES. | | | | | | 3) EP-1: PLEASE NOTE THAT A SEPARATE PERMIT IS REQUIRED | | | FOR THE NEW GUEST COTTAGE- A COMPLETE REVIEW OF THE | | | PLUMBING AT THE COTTAGE WILL NOT BE REVIEWED AT THIS | | | TIME. PLEASE NOTE HOWEVER THAT THE CURRENT RISER | | | DRAWING SHOWS A NON-COMPLIANT WET VENT FOR THE COTTAGE | | | FIXTURE DRAINS- NOT MORE THAN ONE WET VENTED FIXTURE | | | SHALL DISCHARGE UPSTREAM OF THE DRY VENTED FIXTURE | | | DRAIN CONNECTION. | | | | | | 4) EP-1: IN ACCORDANCE WITH SECTION 7C OF THE WPB | | | UTILITIES MANUAL FOR CROSS-CONNECTION CONTROL A | | | BACKFLOW ASSEMBLY SHALL BE INSTALLED ON THE POTABLE | | | WATER SERVICE TO THE MULTI- FAMILY PROPERTY. | | | PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR | | | SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE | | | BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB | | | AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL | | | BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT | | | PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT. | | | PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS | | | DEPT.AT 561-822-2210 FOR FURTHER INFORMATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-05 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-05 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2021-11-05 08:53:59 | PROVISO ON PLAN PAGE A5: A SEPERATE ROOFING PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-28 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-11 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-11 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-21 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-21 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2021-10-21 13:27:44 | SIGNATURE REVIEW APPROVED WITH DIGITAL SIGNATES AND | | | SEALS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-02-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2022-02-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-16 10:08:19 | * FOR INTERIOR IMPROVEMENTS AND SMALL ADDITION TO THE | | | MAIN HOUSE ONLY. | | | | | | * SEPARATE PERMIT SUBMITTED FOR REAR STRUCTURE | | | IMPROVEMENTS (REFERENCE: PERMIT #22010888). | | | | | | * HISTORIC STOP ADDED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-10-05 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-10-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-05 09:14:01 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) UPDATED SIGNED AND SEALED SURVEY OF THE PROPERTY IS | | | REQUIRED. PLEASE NOTE IN ORDER TO PERMIT THE PROPOSED | | | GUEST COTTAGE BY-RIGHT, THE PROPERTY MUST HAVE THE | | | FOLLOWING LOT DIMENSIONS: MINIMUM LOT SIZE = 6,000 SQ. | | | FT. AND MINIMUM LOT WIDTH = 60 FT. [ZLDR S.94-71, TABLE | | | III-1] | | | | | | 2.) SITE PLAN SHOWING THE BUILDING SETBACKS OF THE | | | PROPOSED ADDITION(S) IS REQUIRED. ANY EXPANSION OF THE | | | BUILDING MUST COMPLY WITH THE SETBACK REQUIREMENTS OF | | | SEC. 94-74 OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDRS). | | | | | | 3.) NOTATE HEIGHT OF THE BUILDING(S) IN THE ELEVATION | | | SHEETS. | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF14 | | | |
|
|