| Plan Review Stops For Permit 21081725 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-24 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-18 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-18 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2021-11-18 09:30:58 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-29 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-29 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2021-09-29 08:09:57 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-19 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-19 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-24 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-18 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-18 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2021-11-18 09:30:28 | REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE THE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE NEW EXTERIOR WINDOW THAT IS | | | LISTED ON THE DRAWINGS. | | | 2) PLEASE SHOW THE REQUIRED WIND DESIGN PRESSURE FOR | | | THE NEW EXTERIOR WINDOW OPENING. FBC 1603.1.4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-29 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-29 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2021-09-29 08:08:35 | REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE THE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE NEW EXTERIOR WINDOW. PRODUCT | | | APPROVALS NEED TO BE REVIEWED AND MARKED APPROVED BY | | | THE REMODEL DESIGNER OF RECORD. FBC WPB 107 | | | 2) PLEASE SHOW THE REQUIRED WIND DESIGN PRESSURE FOR | | | THE NEW EXTERIOR WINDOW OPENING. FBC 1603.1.4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-07-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-26 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-26 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-12-17 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-17 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-04 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-04 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-07-08 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-07-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-11-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-09-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-07-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-26 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-07 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-17 |
Time |
06:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-12-17 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-11-09 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-04 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-02 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-11 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-11 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-10 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-10 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-03 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-03 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2021-09-03 08:21:49 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21081725 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE MORE INFORMATION ABOUT THE FIRE | | | DAMPERS IN THE CEILING OF THE 2 ROOMS. WHAT IS THE | | | RATING OF THESE ROOMS? ARE THERE FIRE DAMPERS WHERE THE | | | EXISTING DUCT PENETRATE THE RATED WALLS? IN THE SMALLER | | | ROOM, IS THERE NOT GOING TO BE A RETURN AIR GRILL? WHY | | | DO THE RETURN AIR GRILLS IN THESE ROOMS NOT HAVE A FIRE | | | DAMPER? | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-19 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-19 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-24 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2022-02-24 11:28:15 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED- | | | | | | 1) DRAWINGS HAVE BEEN REVISED - ALL DRAWINGS DO NOT | | | SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-11-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-18 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-18 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2021-11-18 09:33:23 | SIGNATURE REVIEW | | | | | | ALL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | | READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-09-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-09-29 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-29 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|