Plan Review Details - Permit 21081571
Plan Review Stops For Permit 21081571
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-12-26 Cont ID  
Sent By cthroop Date 2021-12-26 Time 10:41 Rev Time 0.00
Received By cthroop Date 2021-12-26 Time 10:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-23 Cont ID  
Sent By cthroop Date 2021-10-23 Time 08:25 Rev Time 0.00
Received By cthroop Date 2021-10-23 Time 07:44 Sent To  
Notes
2021-10-23 08:35:44BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A COPY OF THE MOST RECENT BOUNDRY LINE
 SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE A SITE PLAN WITH DEMENSIONS TO PROPERTY
 LINES.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE
 SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE AND INCLUDED BOUNDARY LINE SURVEY.
  
 3. STRUCTURE IS SUBJECT TO WIND LOADS. PROVIDE DESIGN
 WIND LOAD PRESSURES FOR STRUCTURE PER FBC R CHPT 3 OR
 FBC CHPT 16 ASCE 7-16.
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
 4. PROVIDE A STRUCTURAL DETAIL OF CABINET WITH
 DEMENSIONS. INCLUDE WALL TO FOUNDATION CONNECTION
 DETAIL WITH A CONNECTOR AND FASTENER SCHEDULE DESIGNED
 PER THE CALCULATED WIND PRESSURES.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-29 Cont ID  
Sent By mpeterso Date 2021-12-29 Time 15:48 Rev Time 0.00
Received By mpeterso Date 2021-12-29 Time 15:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-10-05 Cont ID  
Sent By jleahy Date 2021-10-05 Time 14:43 Rev Time 0.00
Received By jleahy Date 2021-10-05 Time 14:42 Sent To  
Notes
2021-10-05 14:44:49FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEED TO SHOW LOCATION OF OUTLETS AND TYPE WP, TR ?

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-12-12 Cont ID  
Sent By abelisle Date 2021-12-12 Time 11:57 Rev Time 0.00
Received By abelisle Date 2021-12-12 Time 11:42 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-09-30 Cont ID  
Sent By ccole Date 2021-09-30 Time 11:36 Rev Time 0.00
Received By ccole Date 2021-09-30 Time 11:10 Sent To  
Notes
2021-09-30 11:47:001ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 21081487
 9/30/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PLAN INDICATES AN EXISTING GAS LINE TO THE
 SUMMER KITCHEN, HOWEVER THE WPB BUILDING DEPT. RECORDS
 DO NOT SHOW A PREVIOUS GAS PERMIT OR PLANS AT THE
 RESIDENCE. PLEASE PROVIDE A COMPLETE GAS RISER DRAWING
 THAT INCLUDES ALL NEW AND EXISTING GAS PIPING AND
 APPLIANCES AT THE RESIDENCE- SECTION G2412.3 & G2412.4
 FBC RES. REFER TO FBC RES. CHAPTER 24 FUEL GAS- THE
 RISER SHALL SHOW:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 H) OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES.
  
 6) INDICATE THE MAKES AND MODELS OF REGULATORS TO BE
 INSTALLED ON THE SYSTEM AND SUBMIT MANUFACTURER?S
 SPECIFICATIONS MARKED UP TO SHOW THE SELECTED MODELS,
 AND INPUT AND OUT PIPE SIZES AND PRESSURES- SECTION
 G2421.2 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-01-18 Cont ID  
Sent By mpeterso Date 2022-01-18 Time 15:06 Rev Time 0.00
Received By mpeterso Date 2022-01-18 Time 15:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-18 Cont ID  
Sent By mpeterso Date 2022-01-18 Time 13:28 Rev Time 0.00
Received By mpeterso Date 2021-12-09 Time 06:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-23 Cont ID  
Sent By cthroop Date 2021-10-23 Time 08:35 Rev Time 0.00
Received By cthroop Date 2021-09-27 Time 12:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-12-12 Cont ID  
Sent By abelisle Date 2021-12-12 Time 11:53 Rev Time 0.00
Received By abelisle Date 2021-12-12 Time 11:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-09-30 Cont ID  
Sent By ccole Date 2021-09-30 Time 11:36 Rev Time 0.00
Received By ccole Date 2021-09-30 Time 11:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-01-18 Cont ID  
Sent By mpeterso Date 2022-01-18 Time 13:20 Rev Time 0.00
Received By mpeterso Date 2022-01-18 Time 15:01 Sent To  
Notes
2022-01-18 13:28:12SIGNATURE REVIEW PASSED WITH PAPER PLANS A-1-2 AND
 COVER SHEET WITH WET SEAL AND SIGNATURE
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-12-26 Cont ID  
Sent By cthroop Date 2021-12-26 Time 10:39 Rev Time 0.00
Received By cthroop Date 2021-12-26 Time 10:00 Sent To  
Notes
2021-12-26 10:40:49SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 2ND REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-10-21 Cont ID  
Sent By mpeterso Date 2021-10-21 Time 13:39 Rev Time 0.00
Received By mpeterso Date 2021-10-21 Time 13:39 Sent To  
Notes
2021-10-21 13:40:52SIGNATURE BY FLORIDA LICENSED, REGISTERED, DESIGN
 PROFFESIONAL NOT REQUIRED.

Review Stop Z ZONING
Rev No 2 Status P Date 2022-01-14 Cont ID  
Sent By jroach Date 2022-01-14 Time 10:58 Rev Time 0.00
Received By jroach Date 2022-01-14 Time 10:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-10-14 Cont ID  
Sent By jroach Date 2021-10-14 Time 15:56 Rev Time 0.00
Received By jroach Date 2021-10-14 Time 15:55 Sent To  
Notes
2021-10-14 15:57:42ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 10.14.2021
 PERMIT NO.: 21081571
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. A SURVEY AND SITE PLAN SHALL BE PROVIDED SHOWING THE
 LOCATION OF THE PROPOSED BBQ. DIMENSIONS SHALL BE
 PROVIDED FROM THE BBQ TO ALL SURROUNDING PROPERTY
 LINES.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved