Plan Review Details - Permit 21081557
Plan Review Stops For Permit 21081557
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-09-09 Cont ID  
Sent By cpuell Date 2021-09-09 Time 14:15 Rev Time 0.00
Received By cpuell Date 2021-09-09 Time 14:15 Sent To  
Notes
2021-09-09 14:15:43ADDRESS FOR PARCEL OK FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2021-12-21 Cont ID  
Sent By jgomez Date 2021-12-21 Time 16:37 Rev Time 0.00
Received By jgomez Date 2021-12-21 Time 16:25 Sent To  
Notes
2021-12-21 16:37:35BUILDING REVIEW APPROVED WITH PROVISO.
 NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSPECTIONS TO AVOID CONFLICTS/DELAYS:
 1-DEFERRED SUBMITTAL: PROVIDE SHOP DRAWINGS (SIGNED &
 SEALED) FOR HAMBRO ROOF & FLOOR SYSTEMS SHOWING ALL
 FRAMING MEMBERS AND CONNECTORS.
  
 2- PROVIDE PRODUCT APPROVAL FOR:
 A)ICF WALL SYSTEM SPECIFIED ON PLANS.
 B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK ASSEMBLY TO BE
 INSTALLED.
 C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO
 BE USED.
 D) ALL DOORS AND WINDOWS TYPES SHOWN ON PLANS.
  
 4-ENGINEER OF RECORD TO REVIEW/APPROVE IN WRITING ALL
 PRODUCT APPROVALS.
  
 5-PROVIDE ICC EVALUATION REPORT FOR THE SPRAY FOAM
 INSULATION.
 NOTE: ENGINEER OF RECORD TO REVIEW/APPROVE PRIOR TO
 SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-12-16 Cont ID  
Sent By jgomez Date 2021-12-16 Time 11:14 Rev Time 0.00
Received By jgomez Date 2021-12-16 Time 11:07 Sent To  
Notes
2021-12-16 11:15:00BUILDING REVIEW APPROVED WITH PROVISO.
 NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSPECTIONS TO AVOID CONFLICTS/DELAYS:
 1-REVISE ENERGY CALCULATIONS: A)NEED COMPLETE AND
 CORRECT INFORMATION. OWNER'S NAME, BUILDER'S
 NAME,CORRECT PERMIT OFFICE IS WEST PALM BEACH, CORRECT
 JURISDICTION IS 604700. B)REVISE WALL TYPE ON ITEM
 10(B) TO MATCH PLANS. PLANS DON'T SPECIFY WOOD FRAME
 WALL. C)REVISE DOOR INFORMATION ON PAGE 4. PLANS DON'T
 SHOW ANY WOOD DOOR ON THE EAST SIDE. D)REVISE WINDOWS
 OVERHANG DEPTH & SEPARATION TO MATCH PLANS.
  
 2-DEFERRED SUBMITTAL: PROVIDE SHOP DRAWINGS (SIGNED &
 SEALED) FOR HAMBRO ROOF & FLOOR SYSTEMS SHOWING ALL
 FRAMING MEMBERS AND CONNECTORS.
  
 3- PROVIDE PRODUCT APPROVAL FOR:
 A)ICF WALL SYSTEM SPECIFIED ON PLANS.
 B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK ASSEMBLY TO BE
 INSTALLED.
 C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO
 BE USED.
 D) ALL DOORS AND WINDOWS TYPES SHOWN ON PLANS.
  
 4-ENGINEER OF RECORD TO REVIEW/APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS.
  
 5-PROVIDE ICC EVALUATION REPORT FOR THE SPRAY FOAM
 INSULATION.
 NOTE: ENGINEER OF RECORD TO REVIEW/APPROVE PRIOR TO
 SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-12-14 Cont ID  
Sent By jgomez Date 2021-12-14 Time 13:22 Rev Time 0.00
Received By jgomez Date 2021-12-14 Time 10:50 Sent To  
Notes
2021-12-14 11:13:27BUILDING REVIEW APPROVED WITH PROVISO.
 NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSPECTIONS TO AVOID CONFLICTS/DELAYS:
 1-REVISE ENERGY CALCULATIONS: A)NEED COMPLETE AND
 CORRECT INFORMATION. OWNER'S NAME, BUILDER'S
 NAME,CORRECT PERMIT OFFICE IS WEST PALM BEACH, CORRECT
 JURISDICTION IS 604700. B)REVISE WALL TYPE ON ITEM
 10(B) TO MATCH PLANS. PLANS DON'T SPECIFY WOOD FRAME
 WALL. C)REVISE DOOR INFORMATION ON PAGE 4. PLANS DON'T
 SHOW ANY WOOD DOOR ON THE EAST SIDE. D)REVISE WINDOWS
 OVERHANG DEPTH & SEPARATION TO MATCH PLANS.
  
 2-DEFERRED SUBMITTAL: PROVIDE SHOP DRAWINGS (SIGNED &
 SEALED) FOR HAMBRO ROOF & FLOOR SYSTEMS SHOWING ALL
 FRAMING MEMBERS AND CONNECTORS.
  
 3- PROVIDE PRODUCT APPROVAL FOR:
 A)ICF WALL SYSTEM SPECIFIED ON PLANS.
 B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK ASSEMBLY TO BE
 INSTALLED.
 C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO
 BE USED.
 D) ALL DOORS AND WINDOWS TYPES SHOWN ON PLANS.
  
 4-ENGINEER OF RECORD TO REVIEW/APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS.
  
 5-PROVIDE ICC EVALUATION REPORT FOR THE SPRAY FOAM
 INSULATION.
 NOTE: ENGINEER OF RECORD TO REVIEW/APPROVE PRIOR TO
 SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-12-13 Cont ID  
Sent By jgomez Date 2021-12-13 Time 15:36 Rev Time 0.00
Received By jgomez Date 2021-12-13 Time 13:20 Sent To  
Notes
2021-12-13 15:37:46NEW SINGLE FAMILY RESIDENCE (R3), SECOND BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21081557
  
 ORIGINAL COMMENT:
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 RESPONSE:
 A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. PROVIDE OWNER'S NAME, BUILDER'S NAME, CORRECT
 PERMIT OFFICE IS WEST PALM BEACH NOT PALM BEACH COUNTY,
 CORRECT JURISDICTION IS 604700 NOT 601000.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C)REVISE WALL TYPE ON ITEM 10(B) TO MATCH PLANS. PLANS
 DON'T SPECIFY WOOD FRAME WALL. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 D)CLARIFY DOOR INFORMATION ON PAGE 4. PLANS DON'T SHOW
 ANY WOOD DOOR ON THE EAST SIDE.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 E)REVISE WINDOWS OVERHANG DEPTH AND SEPARATION TO MATCH
 PLANS. SEC. R101.5.1.1.2 FBC-. ENERGY CONSERVATION.
 NOTE: SEE EXTERIOR ELEVATIONS.
  
 F) BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 2- OK.
 3-OK.
  
 4- DEFERRED SUBMITTAL: ROOF FRAMING PLAN AND STRUCTURAL
 DETAILS ON SHEET S-2 CALL FOR HAMBRO COMPOSITE FLOOR
 SYSTEM W/ 3" CONCRETE SLAB. PROVIDE COMPLETE SHOP
 DRAWINGS (SIGNED AND SEALED) SHOWING ALL FRAMING
 MEMBERS AND ALL STRUCTURAL CONNECTORS. NOTE: SUBMIT
 THESE SHOP DRAWINGS PRIOR TO CONSTRUCTION TO AVOID
 CONFLICTS/DELAYS.
 NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 5- OK
 6- OK
 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)ICF WALL SYSTEM SPECIFIED ON PLANS.
  
 B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO
 BE USED.
 NOTE:CLEARLY IDENTIFY OPENING LOCATION TO AVOID
 DELAYS/CONFLICTS.
  
 D) ALL DOORS AND WINDOW TYPES SHOWN ON PLANS.
  
 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC.
 107.3.4.1 CITY AMENDMENTS.
  
 9- OK
  
 10- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ENGINEER IS
 SPECIFYING R-25 SPRAY FOAM INSULATION. PROVIDE ICC
 EVALUATION REPORT FOR THE SPRAY FOAM INSULATION TO
 VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL.
 NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE THE
 REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-11-04 Cont ID  
Sent By jgomez Date 2021-11-04 Time 17:19 Rev Time 0.00
Received By jgomez Date 2021-11-04 Time 17:19 Sent To  
Notes
2021-11-04 17:20:14NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21081557
  
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 2- LOT DRAINAGE
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
  
 3- DESIGN PRESSURES SPECIFIED ON THE WINDOW AND DOOR
 SCHEDULES ON SHEET A-2 DON'T CORRESPOND TO THE WIND
 DESIGN CRITERIA SPECIFIED ON COVER SHEET G-1. ENGINEER
 SPECIFIES ULTIMATE WIND SPEED OF 250MPH (194 MPH
 NOMINAL WIND SPEED). REVISE AS REQUIRED TO MATCH. SEC.
 R301.2.1 FBC-RESIDENTIAL.
  
 4- DEFERRED SUBMITTAL: ROOF FRAMING PLAN AND STRUCTURAL
 DETAILS ON SHEET S-2 CALL FOR HAMBRO COMPOSITE FLOOR
 SYSTEM W/ 3" CONCRETE SLAB. PROVIDE COMPLETE SHOP
 DRAWINGS (SIGNED AND SEALED) SHOWING ALL FRAMING
 MEMBERS AND ALL STRUCTURAL CONNECTORS. NOTE: SUBMIT
 THESE SHOP DRAWINGS PRIOR TO CONSTRUCTION TO AVOID
 CONFLICTS/DELAYS.
 NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 5- ROOF PLAN ON SHEET A-6. ROOF AREA ABOVE GARAGE NEEDS
 OVERFLOW SCUPPER AS REQUIRED BY SEC. R903.4.1
 FBC-RESIDENTIAL.
 NOTE: SECONDARY OVERFLOW SCUPPERS SHOWN ON THE MAIN
 ROOF NEED TO BE AT LEAST 2" ABOVE FINISH ROOF AS
 REQUIRED BY SEC. R903.4.1 FBC-RESIDENTIAL. PROVIDE
 DETAIL.
  
 6- DESIGNER OF RECORD TO SPECIFY THE EXTERIOR WALLS
 INSULATION R-VALUE AS REQUIRED BY SEC. R103.2
 FBC-ENERGY CONSERVATION.
  
 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)ICF WALL SYSTEM SPECIFIED ON PLANS.
  
 B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 C)WINDOW MULLION NOA 17-0630.01 SUBMITTED EXPIRED ON
 MAY 26, 2021. NEED CURRENT ONE AND SPECIFY ALL MULLION
 SIZES TO BE USED.
 NOTE:CLEARLY IDENTIFY OPENING LOCATION TO AVOID
 DELAYS/CONFLICTS.
  
 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC.
 107.3.4.1 CITY AMENDMENTS.
  
 9- PROVIDE COMPLETE STRUCTURAL BUCK DETAIL FOR OVERHEAD
 GARAGE DOOR ON ICF WALL AND ALL EXTERIOR DOORS AND
 WINDOWS. NOTE: CLEARLY SPECIFY BUCK SIZE AND FASTENER
 TYPE SIZE AND SPACING. SPECIFY MINIMUM EMBEDMENT INTO
 CONCRETE. SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 10- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ENGINEER IS
 SPECIFYING R-25 SPRAY FOAM INSULATION. PROVIDE ICC
 EVALUATION REPORT FOR THE SPRAY FOAM INSULATION TO
 VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL.
 NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE THE
 REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 11- DRAWINGS S-1 AND S-2 ARE NOT SIGNED AND SEALED BY
 THE ENGINEER OF RECORD. DRAWINGS NEED TO HAVE THE
 ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC.
 61G15-23.001 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING
 PLANS/DOCUMENTS FOR PUBLIC RECORDS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-14 Cont ID  
Sent By jleahy Date 2021-12-14 Time 16:24 Rev Time 0.00
Received By jleahy Date 2021-12-14 Time 15:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-10-07 Cont ID  
Sent By jleahy Date 2021-10-07 Time 11:23 Rev Time 0.00
Received By jleahy Date 2021-10-07 Time 09:29 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2021-09-28 Cont ID  
Sent By lcrespo Date 2021-09-28 Time 14:09 Rev Time 0.00
Received By lcrespo Date 2021-09-28 Time 14:09 Sent To  
Notes
2021-09-28 14:10:27GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT
 BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND
 PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-12-21 Cont ID  
Sent By jgomez Date 2021-12-21 Time 16:55 Rev Time 0.00
Received By jgomez Date 2021-12-20 Time 13:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-15 Cont ID  
Sent By lmarchan Date 2021-12-15 Time 09:21 Rev Time 0.00
Received By lmarchan Date 2021-11-18 Time 07:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-04 Cont ID  
Sent By jgomez Date 2021-11-04 Time 17:26 Rev Time 0.00
Received By jgomez Date 2021-09-09 Time 13:06 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-12-22 Cont ID  
Sent By lmarchan Date 2021-12-22 Time 14:50 Rev Time 0.00
Received By lmarchan Date 2021-12-14 Time 16:13 Sent To  
Notes
2021-12-22 12:12:06RECEIPT MU-2021-059117 - $2491.56 PAID
2021-12-14 16:13:3512/14/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-11-04 Cont ID  
Sent By jgomez Date 2021-11-04 Time 17:26 Rev Time 0.00
Received By jgomez Date 2021-11-04 Time 17:25 Sent To  
Notes
2021-11-04 17:26:28IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-12-21 Cont ID  
Sent By medwards Date 2021-12-21 Time 09:23 Rev Time 0.00
Received By medwards Date 2021-12-21 Time 09:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-11-29 Cont ID  
Sent By medwards Date 2021-11-22 Time 14:27 Rev Time 0.00
Received By medwards Date 2021-11-22 Time 14:27 Sent To  
Notes
2021-11-22 14:33:14 
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-09-21 Cont ID  
Sent By medwards Date 2021-09-21 Time 16:47 Rev Time 0.00
Received By medwards Date 2021-09-21 Time 16:47 Sent To  
Notes
2021-09-21 16:47:571ST REVIEW FBC-2020 MECHANICAL
 PERMIT
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SUBMIT THE ENERGY CALCULATIONS. FBC EC
 101.5.1.1.2
  
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC R403.7.1
  
 3) PLEASE PROVIDE THE HOOD DETAILS FOR THE OUTDOOR
 GRILLE. FBC 107.2.1
  
 4) PLEASE PROVIDE THE CFM?S OF EXHAUST AIR FOR THE
 KITCHEN HOOD. FBC RES M1503.4
  
 5) PLEASE PROVIDE THE CODE COMPLIANT MECHANICAL DRAWING
 FOR THIS PROJECT. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-09-30 Cont ID  
Sent By lcrespo Date 2021-09-28 Time 07:36 Rev Time 0.00
Received By lcrespo Date 2021-09-28 Time 14:00 Sent To  
Notes
2021-09-30 07:36:4409/28/21 REVIEWED FOR CODE COMPLIANCE
 (PLUMBING/BACKFLOW)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2022-05-20 Cont ID  
Sent By jgomez Date 2021-12-14 Time 13:26 Rev Time 0.00
Received By jgomez Date 2021-12-14 Time 13:26 Sent To  
Notes
2021-12-14 13:28:19PROVIDE COMPLETE ROOFING INFORMATION FOR REVIEW:
  
 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: PROVIDE COMPLETE INFORMATION FOR REVIEW PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS).
 A)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) PRODUCT APPROVAL AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2021-12-13 Cont ID  
Sent By jgomez Date 2021-12-13 Time 15:40 Rev Time 0.00
Received By jgomez Date 2021-12-13 Time 15:40 Sent To  
Notes
2021-12-13 15:41:04ROOFING REVIEW:
  
 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) PRODUCT APPROVAL AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-11-04 Cont ID  
Sent By jgomez Date 2021-11-04 Time 17:24 Rev Time 0.00
Received By jgomez Date 2021-11-04 Time 17:23 Sent To  
Notes
2021-11-04 17:25:40ROOFING REVIEW:
  
 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) PRODUCT APPROVAL AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2021-12-21 Cont ID  
Sent By jgomez Date 2021-12-21 Time 16:46 Rev Time 0.00
Received By jgomez Date 2021-12-21 Time 16:45 Sent To  
Notes
2021-12-21 16:47:23HARD COPY WITH ENGINEER'S EMBOSSED SEAL AND ORIGINAL
 SIGNATURE SENT TO STORAGE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2021-12-16 Cont ID  
Sent By jgomez Date 2021-12-16 Time 11:05 Rev Time 0.00
Received By jgomez Date 2021-12-16 Time 10:46 Sent To  
Notes
2021-12-16 11:06:19HARD COPY WITH ENGINEER'S EMBOSSED SEAL AND ORIGINAL
 SIGNATURE SENT TO STORAGE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2021-12-14 Cont ID  
Sent By jgomez Date 2021-12-14 Time 13:24 Rev Time 0.00
Received By jgomez Date 2021-12-14 Time 10:58 Sent To  
Notes
2021-12-14 13:25:14SIGNATURE REVIEW:
 1- DRAINAGE PLAN NEEDS ENGINEER'S ORIGINAL
 SEAL/SIGNATURE AS REQUIRED BY SEC. 471 F.S.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-12-13 Cont ID  
Sent By jgomez Date 2021-12-13 Time 15:41 Rev Time 0.00
Received By jgomez Date 2021-12-13 Time 15:41 Sent To  
Notes
2021-12-13 15:43:44SIGNATURE REVIEW:
 1- DRAINAGE PLAN NEEDS ENGINEER'S ORIGINAL
 SEAL/SIGNATURE AS REQUIRED BY SEC. 471 F.S.
 2- SURVEY NEEDS ENGINEER'S ORIGINAL SEAL/SIGNATURE AS
 REQUIRED BY SEC. 471 F.S.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-11-10 Cont ID  
Sent By jgomez Date 2021-11-10 Time 13:43 Rev Time 0.00
Received By jgomez Date 2021-11-10 Time 13:37 Sent To  
Notes
2021-11-10 13:46:45SIGNATURE REVIEW:
  
 1- DRAWINGS S-1 AND S-2 ARE NOT SIGNED AND SEALED BY
 THE ENGINEER OF RECORD. DRAWINGS NEED TO HAVE THE
 ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC.
 61G15-23.001 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING
 PLANS/DOCUMENTS FOR PUBLIC RECORDS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-10-21 Cont ID  
Sent By mpeterso Date 2021-10-21 Time 09:05 Rev Time 0.00
Received By mpeterso Date 2021-11-04 Time 15:24 Sent To  
Notes
2021-10-21 09:14:11IT APPEARS THE FOUNDATION AND ROOF FRAMING PLANS DO NOT
 HAVE A SEAL AND SIGNATURE FROM A P.E. OR ARCHITECH.
 EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF
 APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX,
 OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER
 ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION.
 SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO
 BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED
 DOCUMENTS ARE PREFERRED.
  
 IN ADDITION THE SURVEY REQUIRES AN ORGINAL SEAL AND
 SIGNATURE
  
 PLEASE EMAIL [email protected] AND CC TO
 [email protected]
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop Z ZONING
Rev No 2 Status P Date 2021-12-01 Cont ID  
Sent By awooten Date 2021-12-01 Time   Rev Time 0.00
Received By awooten Date 2021-12-01 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-09-20 Cont ID  
Sent By awooten Date 2021-09-20 Time   Rev Time  
Received By awooten Date 2021-09-20 Time   Sent To  
Notes
2021-09-20 12:46:18*******************ZONING REVIEW
 FAILED*********************
  
  
 PROVIDE A SEPARATE LANDSCAPE AND IRRIGATION PLAN
 SHOWING THE FOLLOWING:
  
 RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
 SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
  
 O GROSS LOT SQUARE FOOTAGE MINUS
 O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
 O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE
 OR PORTION THEREOF
 O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE
 OR PORTION THEREOF
  
 THE PROPOSED DRIVEWAY, POOL, AND FENCE REQUIRE A
 SEPARATE PERMIT.
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISON
 561-822-1449
 [email protected]
  