| Plan Review Stops For Permit 21081557 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-09-09 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-09-09 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2021-09-09 14:15:43 | ADDRESS FOR PARCEL OK FOR PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-21 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-21 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2021-12-21 16:37:35 | BUILDING REVIEW APPROVED WITH PROVISO. | | | NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS: | | | 1-DEFERRED SUBMITTAL: PROVIDE SHOP DRAWINGS (SIGNED & | | | SEALED) FOR HAMBRO ROOF & FLOOR SYSTEMS SHOWING ALL | | | FRAMING MEMBERS AND CONNECTORS. | | | | | | 2- PROVIDE PRODUCT APPROVAL FOR: | | | A)ICF WALL SYSTEM SPECIFIED ON PLANS. | | | B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK ASSEMBLY TO BE | | | INSTALLED. | | | C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO | | | BE USED. | | | D) ALL DOORS AND WINDOWS TYPES SHOWN ON PLANS. | | | | | | 4-ENGINEER OF RECORD TO REVIEW/APPROVE IN WRITING ALL | | | PRODUCT APPROVALS. | | | | | | 5-PROVIDE ICC EVALUATION REPORT FOR THE SPRAY FOAM | | | INSULATION. | | | NOTE: ENGINEER OF RECORD TO REVIEW/APPROVE PRIOR TO | | | SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-16 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-16 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2021-12-16 11:15:00 | BUILDING REVIEW APPROVED WITH PROVISO. | | | NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS: | | | 1-REVISE ENERGY CALCULATIONS: A)NEED COMPLETE AND | | | CORRECT INFORMATION. OWNER'S NAME, BUILDER'S | | | NAME,CORRECT PERMIT OFFICE IS WEST PALM BEACH, CORRECT | | | JURISDICTION IS 604700. B)REVISE WALL TYPE ON ITEM | | | 10(B) TO MATCH PLANS. PLANS DON'T SPECIFY WOOD FRAME | | | WALL. C)REVISE DOOR INFORMATION ON PAGE 4. PLANS DON'T | | | SHOW ANY WOOD DOOR ON THE EAST SIDE. D)REVISE WINDOWS | | | OVERHANG DEPTH & SEPARATION TO MATCH PLANS. | | | | | | 2-DEFERRED SUBMITTAL: PROVIDE SHOP DRAWINGS (SIGNED & | | | SEALED) FOR HAMBRO ROOF & FLOOR SYSTEMS SHOWING ALL | | | FRAMING MEMBERS AND CONNECTORS. | | | | | | 3- PROVIDE PRODUCT APPROVAL FOR: | | | A)ICF WALL SYSTEM SPECIFIED ON PLANS. | | | B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK ASSEMBLY TO BE | | | INSTALLED. | | | C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO | | | BE USED. | | | D) ALL DOORS AND WINDOWS TYPES SHOWN ON PLANS. | | | | | | 4-ENGINEER OF RECORD TO REVIEW/APPROVE IN WRITING (NOT | | | SIGNING AND SEALING) ALL PRODUCT APPROVALS. | | | | | | 5-PROVIDE ICC EVALUATION REPORT FOR THE SPRAY FOAM | | | INSULATION. | | | NOTE: ENGINEER OF RECORD TO REVIEW/APPROVE PRIOR TO | | | SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-14 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-14 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2021-12-14 11:13:27 | BUILDING REVIEW APPROVED WITH PROVISO. | | | NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS: | | | 1-REVISE ENERGY CALCULATIONS: A)NEED COMPLETE AND | | | CORRECT INFORMATION. OWNER'S NAME, BUILDER'S | | | NAME,CORRECT PERMIT OFFICE IS WEST PALM BEACH, CORRECT | | | JURISDICTION IS 604700. B)REVISE WALL TYPE ON ITEM | | | 10(B) TO MATCH PLANS. PLANS DON'T SPECIFY WOOD FRAME | | | WALL. C)REVISE DOOR INFORMATION ON PAGE 4. PLANS DON'T | | | SHOW ANY WOOD DOOR ON THE EAST SIDE. D)REVISE WINDOWS | | | OVERHANG DEPTH & SEPARATION TO MATCH PLANS. | | | | | | 2-DEFERRED SUBMITTAL: PROVIDE SHOP DRAWINGS (SIGNED & | | | SEALED) FOR HAMBRO ROOF & FLOOR SYSTEMS SHOWING ALL | | | FRAMING MEMBERS AND CONNECTORS. | | | | | | 3- PROVIDE PRODUCT APPROVAL FOR: | | | A)ICF WALL SYSTEM SPECIFIED ON PLANS. | | | B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK ASSEMBLY TO BE | | | INSTALLED. | | | C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO | | | BE USED. | | | D) ALL DOORS AND WINDOWS TYPES SHOWN ON PLANS. | | | | | | 4-ENGINEER OF RECORD TO REVIEW/APPROVE IN WRITING (NOT | | | SIGNING AND SEALING) ALL PRODUCT APPROVALS. | | | | | | 5-PROVIDE ICC EVALUATION REPORT FOR THE SPRAY FOAM | | | INSULATION. | | | NOTE: ENGINEER OF RECORD TO REVIEW/APPROVE PRIOR TO | | | SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-12-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-13 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-13 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2021-12-13 15:37:46 | NEW SINGLE FAMILY RESIDENCE (R3), SECOND BUILDING | | | REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21081557 | | | | | | ORIGINAL COMMENT: | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. | | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | | CONFLICTS/DELAYS. | | | | | | RESPONSE: | | | A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED | | | AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S | | | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY | | | THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY | | | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | | FORM. PROVIDE OWNER'S NAME, BUILDER'S NAME, CORRECT | | | PERMIT OFFICE IS WEST PALM BEACH NOT PALM BEACH COUNTY, | | | CORRECT JURISDICTION IS 604700 NOT 601000. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | C)REVISE WALL TYPE ON ITEM 10(B) TO MATCH PLANS. PLANS | | | DON'T SPECIFY WOOD FRAME WALL. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION. | | | | | | D)CLARIFY DOOR INFORMATION ON PAGE 4. PLANS DON'T SHOW | | | ANY WOOD DOOR ON THE EAST SIDE. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | E)REVISE WINDOWS OVERHANG DEPTH AND SEPARATION TO MATCH | | | PLANS. SEC. R101.5.1.1.2 FBC-. ENERGY CONSERVATION. | | | NOTE: SEE EXTERIOR ELEVATIONS. | | | | | | F) BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE | | | LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY | | | CONSERVATION. | | | | | | 2- OK. | | | 3-OK. | | | | | | 4- DEFERRED SUBMITTAL: ROOF FRAMING PLAN AND STRUCTURAL | | | DETAILS ON SHEET S-2 CALL FOR HAMBRO COMPOSITE FLOOR | | | SYSTEM W/ 3" CONCRETE SLAB. PROVIDE COMPLETE SHOP | | | DRAWINGS (SIGNED AND SEALED) SHOWING ALL FRAMING | | | MEMBERS AND ALL STRUCTURAL CONNECTORS. NOTE: SUBMIT | | | THESE SHOP DRAWINGS PRIOR TO CONSTRUCTION TO AVOID | | | CONFLICTS/DELAYS. | | | NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE IN | | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 5- OK | | | 6- OK | | | 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)ICF WALL SYSTEM SPECIFIED ON PLANS. | | | | | | B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED | | | ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES OF SEC. R301.1 | | | FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO | | | BE USED. | | | NOTE:CLEARLY IDENTIFY OPENING LOCATION TO AVOID | | | DELAYS/CONFLICTS. | | | | | | D) ALL DOORS AND WINDOW TYPES SHOWN ON PLANS. | | | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | 9- OK | | | | | | 10- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ENGINEER IS | | | SPECIFYING R-25 SPRAY FOAM INSULATION. PROVIDE ICC | | | EVALUATION REPORT FOR THE SPRAY FOAM INSULATION TO | | | VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. | | | NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE THE | | | REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-04 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-11-04 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2021-11-04 17:20:14 | NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21081557 | | | | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. | | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID | | | CONFLICTS/DELAYS. | | | | | | 2- LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | | | | 3- DESIGN PRESSURES SPECIFIED ON THE WINDOW AND DOOR | | | SCHEDULES ON SHEET A-2 DON'T CORRESPOND TO THE WIND | | | DESIGN CRITERIA SPECIFIED ON COVER SHEET G-1. ENGINEER | | | SPECIFIES ULTIMATE WIND SPEED OF 250MPH (194 MPH | | | NOMINAL WIND SPEED). REVISE AS REQUIRED TO MATCH. SEC. | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | 4- DEFERRED SUBMITTAL: ROOF FRAMING PLAN AND STRUCTURAL | | | DETAILS ON SHEET S-2 CALL FOR HAMBRO COMPOSITE FLOOR | | | SYSTEM W/ 3" CONCRETE SLAB. PROVIDE COMPLETE SHOP | | | DRAWINGS (SIGNED AND SEALED) SHOWING ALL FRAMING | | | MEMBERS AND ALL STRUCTURAL CONNECTORS. NOTE: SUBMIT | | | THESE SHOP DRAWINGS PRIOR TO CONSTRUCTION TO AVOID | | | CONFLICTS/DELAYS. | | | NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE IN | | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 5- ROOF PLAN ON SHEET A-6. ROOF AREA ABOVE GARAGE NEEDS | | | OVERFLOW SCUPPER AS REQUIRED BY SEC. R903.4.1 | | | FBC-RESIDENTIAL. | | | NOTE: SECONDARY OVERFLOW SCUPPERS SHOWN ON THE MAIN | | | ROOF NEED TO BE AT LEAST 2" ABOVE FINISH ROOF AS | | | REQUIRED BY SEC. R903.4.1 FBC-RESIDENTIAL. PROVIDE | | | DETAIL. | | | | | | 6- DESIGNER OF RECORD TO SPECIFY THE EXTERIOR WALLS | | | INSULATION R-VALUE AS REQUIRED BY SEC. R103.2 | | | FBC-ENERGY CONSERVATION. | | | | | | 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)ICF WALL SYSTEM SPECIFIED ON PLANS. | | | | | | B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED | | | ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES OF SEC. R301.1 | | | FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | C)WINDOW MULLION NOA 17-0630.01 SUBMITTED EXPIRED ON | | | MAY 26, 2021. NEED CURRENT ONE AND SPECIFY ALL MULLION | | | SIZES TO BE USED. | | | NOTE:CLEARLY IDENTIFY OPENING LOCATION TO AVOID | | | DELAYS/CONFLICTS. | | | | | | 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | 9- PROVIDE COMPLETE STRUCTURAL BUCK DETAIL FOR OVERHEAD | | | GARAGE DOOR ON ICF WALL AND ALL EXTERIOR DOORS AND | | | WINDOWS. NOTE: CLEARLY SPECIFY BUCK SIZE AND FASTENER | | | TYPE SIZE AND SPACING. SPECIFY MINIMUM EMBEDMENT INTO | | | CONCRETE. SEC. R301.2.1 FBC-RESIDENTIAL. | | | NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO | | | THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | | FBC-RESIDENTIAL. | | | | | | 10- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ENGINEER IS | | | SPECIFYING R-25 SPRAY FOAM INSULATION. PROVIDE ICC | | | EVALUATION REPORT FOR THE SPRAY FOAM INSULATION TO | | | VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. | | | NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE THE | | | REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 11- DRAWINGS S-1 AND S-2 ARE NOT SIGNED AND SEALED BY | | | THE ENGINEER OF RECORD. DRAWINGS NEED TO HAVE THE | | | ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC. | | | 61G15-23.001 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING | | | PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-12-14 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-14 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-07 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-07 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-28 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-28 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2021-09-28 14:10:27 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT | | | BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND | | | PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-21 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-20 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-12-15 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-18 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-04 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-09-09 |
Time |
13:06 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-12-22 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-14 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2021-12-22 12:12:06 | RECEIPT MU-2021-059117 - $2491.56 PAID | | 2021-12-14 16:13:35 | 12/14/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-04 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-11-04 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2021-11-04 17:26:28 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-21 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-21 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-22 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-22 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-21 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-21 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2021-09-21 16:47:57 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SUBMIT THE ENERGY CALCULATIONS. FBC EC | | | 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7.1 | | | | | | 3) PLEASE PROVIDE THE HOOD DETAILS FOR THE OUTDOOR | | | GRILLE. FBC 107.2.1 | | | | | | 4) PLEASE PROVIDE THE CFM?S OF EXHAUST AIR FOR THE | | | KITCHEN HOOD. FBC RES M1503.4 | | | | | | 5) PLEASE PROVIDE THE CODE COMPLIANT MECHANICAL DRAWING | | | FOR THIS PROJECT. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-30 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-28 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-28 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2021-09-30 07:36:44 | 09/28/21 REVIEWED FOR CODE COMPLIANCE | | | (PLUMBING/BACKFLOW) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2022-05-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-14 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-14 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2021-12-14 13:28:19 | PROVIDE COMPLETE ROOFING INFORMATION FOR REVIEW: | | | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: PROVIDE COMPLETE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS). | | | A)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED | | | ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES OF SEC. R301.1 | | | FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) PRODUCT APPROVAL AS REQUIRED | | | BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-12-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-13 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-13 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2021-12-13 15:41:04 | ROOFING REVIEW: | | | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED | | | ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES OF SEC. R301.1 | | | FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) PRODUCT APPROVAL AS REQUIRED | | | BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-04 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-11-04 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2021-11-04 17:25:40 | ROOFING REVIEW: | | | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK WHICH APPROVED | | | ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE | | | WITH THE DESIGN PRESSURES OF SEC. R301.1 | | | FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) PRODUCT APPROVAL AS REQUIRED | | | BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-21 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-21 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2021-12-21 16:47:23 | HARD COPY WITH ENGINEER'S EMBOSSED SEAL AND ORIGINAL | | | SIGNATURE SENT TO STORAGE. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-16 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-16 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2021-12-16 11:06:19 | HARD COPY WITH ENGINEER'S EMBOSSED SEAL AND ORIGINAL | | | SIGNATURE SENT TO STORAGE. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-14 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-14 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2021-12-14 13:25:14 | SIGNATURE REVIEW: | | | 1- DRAINAGE PLAN NEEDS ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY SEC. 471 F.S. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-12-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-12-13 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-12-13 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2021-12-13 15:43:44 | SIGNATURE REVIEW: | | | 1- DRAINAGE PLAN NEEDS ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY SEC. 471 F.S. | | | 2- SURVEY NEEDS ENGINEER'S ORIGINAL SEAL/SIGNATURE AS | | | REQUIRED BY SEC. 471 F.S. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-11-10 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-11-10 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2021-11-10 13:46:45 | SIGNATURE REVIEW: | | | | | | 1- DRAWINGS S-1 AND S-2 ARE NOT SIGNED AND SEALED BY | | | THE ENGINEER OF RECORD. DRAWINGS NEED TO HAVE THE | | | ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC. | | | 61G15-23.001 FAC AND CHAPTER 471 F.S. WHEN SUBMITTING | | | PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-21 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-04 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2021-10-21 09:14:11 | IT APPEARS THE FOUNDATION AND ROOF FRAMING PLANS DO NOT | | | HAVE A SEAL AND SIGNATURE FROM A P.E. OR ARCHITECH. | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | | | | IN ADDITION THE SURVEY REQUIRES AN ORGINAL SEAL AND | | | SIGNATURE | | | | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-01 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-12-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2021-12-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-09-20 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2021-09-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-09-20 12:46:18 | *******************ZONING REVIEW | | | FAILED********************* | | | | | | | | | PROVIDE A SEPARATE LANDSCAPE AND IRRIGATION PLAN | | | SHOWING THE FOLLOWING: | | | | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | THE PROPOSED DRIVEWAY, POOL, AND FENCE REQUIRE A | | | SEPARATE PERMIT. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISON | | | 561-822-1449 | | | [email protected] | | | |
|
|