|
 |
 |
 |
 |
 |
Plan Review Details - Permit 21081520
| Plan Review Stops For Permit 21081520 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-12-14 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-12-14 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-30 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-08-30 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-12-14 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-12-14 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-14 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-13 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-08-30 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-08-27 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-12-14 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-12-14 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-13 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-13 13:43:04 | BEAM DETAIL DRAWING WITH STAMP AND SIGNATURE APPEARS TO | | | BE A COPY AND FLOOR PLAN DRAWING HAS NO STAMP OR | | | SIGNATURE OR IS NOT IDENTIFIED AS BELONGING TO THE BEAM | | | DRAWING PLAN. ENSURE BOTH PLANS ARE SIGNED AND SEALED | | | AND FOLLOW THE INSTRUCTIONS BELOW TO CORRECT THIS | | | ISSUE. | | | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. A COPY OF A SIGNED | | | PLAN IS NOT CONSIDERED AN ORIGINAL.IT APPEARS THE | | | ENGINEER HAS A DIGITAL SIGNATURE PLEASE EMAIL THE | | | ORIGINAL DIGITALLY SIGNED DOCUMENT | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION. | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-08-30 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-08-30 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2021-08-30 10:24:11 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | | 61G15 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |