Plan Review Details - Permit 21081463
Plan Review Stops For Permit 21081463
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-10-29 Cont ID  
Sent By cpuell Date 2021-10-29 Time 10:36 Rev Time 0.00
Received By cpuell Date 2021-10-29 Time 10:36 Sent To  
Notes
2021-10-29 10:37:03SUITE 100 APPROVED AND DATABASES UPDATED.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-10-12 Cont ID  
Sent By cpuell Date 2021-10-12 Time 16:18 Rev Time 0.00
Received By cpuell Date 2021-10-12 Time 16:18 Sent To  
Notes
2021-10-12 16:38:02SUITE 100 IS NOT A RECOGNIZED SUITE NUMBER, PLEASE
 PROVIDE A FLOOR PLAN SHOWING EVERY SUITE ON THAT FLOOR.
 PLEASE EMAIL TO [email protected] FOR FURTHER QUESTIONS
 YOU CAN ALSO CALL 561-805-6659

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-11-09 Cont ID  
Sent By jwitmer Date 2021-11-09 Time 10:21 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 14:35 Rev Time 0.00
Received By jwitmer Date 2021-10-19 Time 14:29 Sent To  
Notes
2021-10-19 14:35:22COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-11-09 Cont ID  
Sent By jwitmer Date 2021-11-09 Time 10:21 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 15:43 Rev Time 0.00
Received By jwitmer Date 2021-10-19 Time 14:29 Sent To  
Notes
2021-10-19 15:29:19WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT:21081463
 ADD: 1515 N. FLAGLER DR. # 100?
 CONT: BUILD PRO CONSTRUCTION INC.
 TEL: 786-740-2549
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. OCT. 19TH/2021
 ACTION: DENIED
 1) PLEASE SEE ADDRESSING COMMENTS THAT SUITE 100 IS NOT
 A RECOGNIZED SUITE IN OUR DATA BASE.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED.
 2020 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS IDENTIFICATION.
  
 2) SHEET 1SP1 SITE PLAN SHOWS WHAT APPEARS TO BE
 EXISTING OR DEMO FLOOR PLAN AND WHAT APPEARS TO BE A
 PROPOSED FLOOR PLAN. THE PLANS ARE NOT CLEAR AS TO THE
 NATURE OF WORK. 2020 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1.
 W.P.B. ADMINISTRATIVE CODE/2020 DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 3) SHEET 1SP1 IT APPEARS THERE ARE GOING TO BE (2) NEW
 OPENINGS IN THE EXTERIOR WALL, (2) NEW EXTERIOR
 DOORWAYS. THE PLANS DO NOT SHOW HOW THE NEW OPENINGS
 ARE GOING TO SHOW COMPLIANCE WITH THE (MWFRS) MAIN WIND
 FORCE RESISTING SYSTEM, COLUMNS, BEAMS AND OR LINTELS.
  
 4) 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS: (31)(A) EXTERIOR DOORS.
  
 5) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL
 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 6) PLEASE IDENTIFY IN THE PRODUCT APPROVAL BEFORE
 SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION
 TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH
 GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT,
 SILL HEIGTH, TYPE OF GLAZING, MULLION SIZE, LENGTH IF
 UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
 ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
 SIZE. 2020 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
 DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND SPACING
 SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
  
 7) 2020 FBC-B 1603.1.4 WIND DESIGN DATA. THE FOLLOWING
 INFORMATION RELATED TO WIND LOADS SHALL BE SHOWN,
 REGARDLESS OF WHETHER WIND LOADS GOVERN THE DESIGN OF
 THE LATERAL FORCE-RESISTING SYSTEM OF THE STRUCTURE:
  
 7.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 7.2. RISK CATEGORY.
  
 7.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1.
  
 7.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 7.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 7.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 8) SHEET LS-LIFE SAFETY SHEET:
  
 8A) 2020 W. P. B. ADMINISTRATIVE CODE107.3.5 MINIMUM
 PLAN REVIEW CRITERIA
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
  
 MISSING CODE DATA:
 FLOOD HAZARD AREAS, FLOOD ZONES, DESIGN FLOOD
 ELEVATIONS
 PROPOSED ELEVATION CERTIFICATES IN SPECIAL FLOOD HAZARD
 AREAS
 OCCUPANCY GROUP WHAT WILL THE TENANT SPACE BE USED FOR,
 IT APPEARS TO BE A DOCTOR?S OFFICE BUT THERE IS A SHOW
 ROOM?
 MINIMUM TYPE OF CONSTRUCTION
 FIRE RESISTANCE SEPARATION
  
 LIFE SAFETY PLANS SHALL DETERMINE AND SHALL INCLUDE THE
 FOLLOWING:
 CODE DATA/ BUILDING DATA
 OCCUPANT LOAD AND EGRESS CAPACITIES
 GROSS OR NET
 MEANS OF EGRESS EXIT ACCESS
 EXIT
 EXIT DISCHARGE
  
 STRUCTURAL REQUIREMENTS SHALL INCLUDE:
 DESIGN LOADS
 WIND REQUIREMENTS
 BUILDING ENVELOPE
 FLOOD REQUIREMENTS IN ACCORDANCE WITH SECTION 1612
 FLOOR SYSTEMS
 WALL SYSTEMS
  
 9) LIFE SAFETY SHEET THE NEW SITTING ROOM WITH THE DOOR
 TO THE INTERIOR HALLWAY DOES NOT HAVE THE REQUIRED 18
 INCHES ON THE LATCH SIDE FOR MANEUVERING CLEARANCES.
 ACCESS. CODE 404.2.4 MANEUVERING CLEARANCES. DOORS.
 MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL
 COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL
 EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED
 LATCH SIDE FOR SIDE CLEARANCE. SEE FIGURE 404.2.4.1(A).
  
 10) DOOR SIZES ARE NOT GIVEN. 2020 FBC-B 1010.1.1. SIZE
 OF DOORS. CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A
 CLEAR WIDTH OF 32 INCHES MINIMUM. CLEAR OPENINGS OF
 DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN
 THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN
 AT 90 DEGREES.
  
 11) THE LIFE SAFETY SHEET LIST TRAVEL DISTANCE UNDER
 1028.7 PLEASE REFER TO THE 2020 FBC-BUILDING CODE,
 THERE IS NO SUCH REFERENCE. 107.2.1.2. DISCREPANCY IN
 CODE SECTIONS. NOTE OCCUPANT LOADS NEED TO BE KNOWN
 BEFORE TRAVEL DISTANCES ARE ESTABLISHED.
  
 12) THE PERMIT VALUE IS LOW AT $10,000.00 DOLLARS.
 109.3 BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
  
 13) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-11-16 Cont ID  
Sent By jleahy Date 2021-11-16 Time 13:49 Rev Time 0.00
Received By jleahy Date 2021-11-16 Time 13:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-10-13 Cont ID  
Sent By jleahy Date 2021-10-13 Time 12:31 Rev Time 0.00
Received By jleahy Date 2021-10-13 Time 12:20 Sent To  
Notes
2021-10-13 12:31:13ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 WHAT TYPE OF OCCUPANCY IS THIS? WHAT KIND OF TENNANT?
  
 1) PLEASE SUBMIT AN INTERIOR LIGHTING POWER ALLOWANCE
 CALCULATION.
  
 C405.3.2 INTERIOR LIGHTING POWER ALLOWANCE. THE TOTAL
 INTERIOR LIGHTING POWER ALLOWANCE (WATTS) IS DETERMINED
 ACCORDING TO TABLE C405.3.2(1) USING THE BUILDING AREA
 METHOD, OR TABLE C405.3.2(2) USING THE SPACE-BY-SPACE
 METHOD, FOR ALL AREAS OF THE BUILDING COVERED IN THIS
 PERMIT.
  
 2) OUTLETS WITHIN 6' OF A SINK SHALL BE GFCI PROTECTED
 210.8(B)

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-11-09 Cont ID  
Sent By pleduc Date 2021-11-09 Time   Rev Time 0.00
Received By pleduc Date 2021-11-09 Time 15:41 Sent To  
Notes
2021-11-09 15:41:35FIRE PROVISO:
  
 ALL FIRE SPRINKLER & FIRE ALARM WORK. INCLUDING DEMO,
 SHALL BE DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-09-17 Cont ID  
Sent By pleduc Date 2021-09-17 Time   Rev Time 0.00
Received By pleduc Date 2021-09-17 Time 10:44 Sent To  
Notes
2021-09-17 10:48:20FIRE PROVISO:
  
 ALL FIRE SPRINKLER & FIRE ALARM WORK. INCLUDING DEMO,
 SHALL BE DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-22 Cont ID  
Sent By lcrespo Date 2021-11-22 Time 08:59 Rev Time 0.00
Received By lcrespo Date 2021-11-03 Time 15:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 15:30 Rev Time 0.00
Received By jwitmer Date 2021-09-16 Time 08:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-11-22 Cont ID  
Sent By lcrespo Date 2021-11-22 Time 08:59 Rev Time 0.00
Received By lcrespo Date 2021-11-17 Time 09:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-10-12 Cont ID  
Sent By lcrespo Date 2021-10-12 Time 12:50 Rev Time  
Received By lcrespo Date 2021-10-04 Time 14:22 Sent To  
Notes
2021-10-12 12:50:5310/12/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE CITY OF WEST PALM BEACH HAS A RECORD FOR SUITE
 100 AS A DIFFERENT LOCATION, SO PLEASE ADDRESS THE AD
 STOP COMMENTS.
  
 2. WOULD YOU PLEASE PROVIDE WHAT TYPE OF OCCUPANCY THIS
 INTERIOR BUILD-OUT WILL BE AND THE OCCUPANCY LOAD WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 3. WOULD YOU PLEASE GIVE THE LEVEL OF ALTERATION PER
 2020 FLORIDA EXISTING BUILDING CODE 301.1.
  
 4. WOULD YOU PLEASE PROVIDE THE MINIMUM NUMBER OF
 FIXTURES FOR THE OCCUPANT LOAD BASED ON THE ACTUAL USE
 OF THE BUILDING OR SPACE PER TABLE 403.1 MINIMUM NUMBER
 OF FIXTURES.
  
 5. SUBMIT LISTED FIRE-STOPPING DETAILS FOR THE PIPPING
 THROUGH RATED WALLS OR THE FLOORS. PLEASE SUBMIT THE
 COMPLETE ASSEMBLY DETAILS FOR THE SYSTEMS PER THE WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
  
 6. ON SHEET P-1;
  
 A. UNDER GENERAL PLUMBING, NOTE NUMBER TWO REFERS TO
 THE 2017 BUILDING CODE. WOULD YOU PLEASE CORRECT TO THE
 CURRENT PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 B. THERE IS VERBIAGE ABOUT TUB AND SHOWER VALVES THAT
 DO NOT DO WITH THIS PROJECT.
  
 C. WOULD YOU PLEASE PROVIDE A PLUMBING ISOMETRIC WATER
 RISER DIAGRAM PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.5.1.3 (13) COMMERCIAL PLUMBING.
  
 D. THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER
 PIPING, FROM THE SOURCE OF HOT WATER TO THE FIXTURES,
 EXCEEDS 50 FEET. RECIRCULATING SYSTEM PIPING AND
 HEAT-TRACED PIPING SHALL BE CONSIDERED TO BE SOURCES OF
 HOT OR TEMPERED WATER.
  
 E. THE RECIRCULATING MANIFOLD TO THE HOT WATER LINES
 SHALL BE SUPPLIED TO THE SOURCE. THERE IS A TABLE THAT
 LIMITS THE SOURCE AND THE OUTLET; PLEASE REFER TO TABLE
 405.5.1 FOR THE MAXIMUM ALLOWABLE PIPE LENGTH METHOD
 AND SIZE ACCORDANTLY.
  
 F. HOT WATER LINES LOOPED FOR THE RECIRCULATING SYSTEM
 SHALL BE IN A CONTINUOUS LOOP. THERE IS A REQUIREMENT
 IN THE FLORIDA ENERGY CODE SEC. C404.6.1.
  
 G. RECIRCULATING SYSTEM, THE PIPING SHALL BE INSULATED
 IN ITS ENTIRETY, INCLUDING THE SUPPLY AND RETURN PIPING
 OF A CIRCULATING PER C404.4 (A) INSULATION OF PIPING.
  
 I. WOULD YOU PLEASE SHOW LOCATIONS OF WATER HAMMER
 ARRESTORS PER THE 2020 FBC SEC. P604.9
  
 7. ON SHEET P-2;
  
 A. IT SHOWS A NEW SINK, AND IF ONE OF THEM IS A BREAK
 ROOM, PLEASE PROVIDE THE CLEAR FLOOR SPACE AND
 DIMENSION FOR CLEAR FLOOR SPACE OF 30? X 48? PER THE
 2020 FBC SEC. ACC 305.3.
  
 B. PROVIDE CABINET DETAIL SHOWING THE SINK AND OR LAVS
 HEIGHT OF 34 INCHES MAXIMUM PER THE 2020 FBC ACC SEC.
 606.3.
  
 C. IN THE OFFICES, ONE SINK NEEDS TO BE ACCESSIBLE.
 WOULD YOU PLEASE LABEL AND REFER TO LETTER C COMMENTS
 PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 D. IF PER THE FIXTURE TABLE A DRINKING FOUNTAIN IS
 REQUIRED OR ONE IS ON THAT FLOOR, SHOW HOW FAR AND THE
 ACCESSIBILITY DIMENSION OF IT PER THE WPB AMENDMENTS TO
 THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 E. IS THERE AN ICE MAKER OR A COFFEE MAKER, AND IF SO,
 IT SHALL BE EQUIPPED WITH AN IN-LINE VACUUM BREAKER
 THAT COMPLIES WITH ASSE 1024 PER THE 2020 FBC SEC.
 608.13.10.
  
 8. WOULD YOU PLEASE SUBMIT A SLAB REPAIR DETAIL? SHOW
 THE WIDTH OF THE REPAIR, THE MINIMUM THICKNESS OF THE
 CONCRETE TO BE REPLACED, AND THE PSI OF THE CONCRETE.
 SHOW THE SIZE AND LENGTH OF THE DOWELS, THE MINIMUM
 EMBEDMENT DEPTH INTO THE EXISTING SLAB, AND THE SPACING
 OF THE DOWELS IN THE CENTER. THE REPAIR SHALL ALSO
 INCLUDE TERMITE TREATMENT OF THE SOIL AND THE REQUIRED
 VAPOR BARRIER OVER THE SOIL. A COPY OF THE TERMITE
 CERTIFICATE SHALL BE ONSITE FOR A FINAL INSPECTION.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-11-22 Cont ID  
Sent By lcrespo Date 2021-11-22 Time 08:59 Rev Time 0.00
Received By lcrespo Date 2021-11-22 Time 08:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 15:30 Rev Time 0.00
Received By jwitmer Date 2021-10-19 Time 14:30 Sent To  
Notes
***NONE***