|
 |
 |
 |
 |
 |
Plan Review Details - Permit 21081221
| Plan Review Stops For Permit 21081221 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-08-30 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-08-30 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2021-08-30 14:26:00 | GAVE ADDRESS OF 622 N FLAGLER DR PIER PER THE | | | SUGGESTION OF MIKE ORIO. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-19 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-19 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2021-10-19 15:12:34 | NOT A STRUCTURE - NOT A REQUIRED GUARDRAIL |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-09-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-09-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-09-17 08:54:40 | PASSED WITH PROVISOS: | | | | | | CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE | | | INFO ON "CALL BEFORE YOU DIG", GO TO | | | HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY | | | DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE, | | | CHAPTER 556.) | | | | | | THANKS, | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL | | | 33401 | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-10-28 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-09-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-09-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-09-16 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2021-09-16 15:04:08 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION OF A RAILING HEIGHT OF 38'. | | | | | | A RAILING IS FOR STAIRS, A GUARD IS FOR THIS TYPE OF | | | INSTALLATION. THE GURD HEIGHT IS 42". | | | | | | PER NFPA 101 | | | | | | 7.2.2.4 GUARDS AND HANDRAILS. | | | GUARDS ARE TO HELP PREVENT A FALL OVER AN OPEN SIDE OF | | | A WALKING | | | SURFACE. HANDRAILS ARE TO HELP ARREST A FALL ON A STAIR | | | OR RAMP. | | | | | | 7.2.2.4.6 GUARD DETAILS. | | | | | | 7.2.2.4.6.2 GUARDS SHALL BE NOT LESS THAN 42 IN. (1065 | | | MM) HIGH, EXCEPT | | | AS PERMITTED BY ONE OF THE FOLLOWING: | | | (1) EXISTING GUARDS WITHIN DWELLING UNITS SHALL BE | | | PERMITTED TO BE NOT | | | LESS THAN 36 IN. (915 MM) HIGH. | | | (2) THE REQUIREMENT OF 7.2.2.4.6.2 SHALL NOT APPLY IN | | | ASSEMBLY OCCUPANCIES | | | WHERE OTHERWISE PROVIDED IN CHAPTERS 12 AND 13. | | | (3)* EXISTING GUARDS ON EXISTING STAIRS SHALL BE | | | PERMITTED TO BE NOT LESS | | | THAN 30 IN. (760 MM) HIGH. | | | | | | | | | | | | 2) THERE IS NO DIMENSION INDICATED BETWEEN THE PICKETS. | | | | | | 7.2.2.4.6.3* OPEN GUARDS, OTHER THAN APPROVED EXISTING | | | OPEN GUARDS, | | | SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN | | | SUCH THAT A SPHERE | | | 4 IN. (100 MM) IN DIAMETER IS NOT ABLE TO PASS THROUGH | | | ANY OPENING UP | | | TO A HEIGHT OF 34 IN. | | | | | | PLEASE REVIEW AND PROVIDE THE REQUIRED DIMENSION. | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-28 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-27 |
Time |
07:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-19 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-09-15 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-19 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-19 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-09-28 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2021-09-28 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |