Plan Review Details - Permit 21081169
Plan Review Stops For Permit 21081169
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-10-12 Cont ID  
Sent By rmcphers Date 2021-10-12 Time 14:21 Rev Time 0.00
Received By rmcphers Date 2021-10-12 Time 14:21 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-09-21 Cont ID  
Sent By rmcphers Date 2021-09-21 Time 16:16 Rev Time 0.00
Received By rmcphers Date 2021-09-21 Time 16:16 Sent To  
Notes
2021-09-21 16:16:38PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-12 Cont ID  
Sent By rmcphers Date 2021-10-12 Time 14:21 Rev Time 0.00
Received By rmcphers Date 2021-10-12 Time 14:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-21 Cont ID  
Sent By rmcphers Date 2021-09-21 Time 16:16 Rev Time 0.00
Received By rmcphers Date 2021-09-21 Time 15:19 Sent To  
Notes
2021-09-21 16:19:16FIRE PUMP REPLACEMENT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE PROVIDE A COPY OF THE LOUVER PRODUCT APPROVAL
 LISTED ON THE DRAWINGS.
 2) PLEASE SHOW THE DOOR HOURLY FIRE RATING PER FBC
 TABLE 716.5
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-08-31 Cont ID  
Sent By jleahy Date 2021-08-31 Time 16:32 Rev Time 0.00
Received By jleahy Date 2021-08-31 Time 16:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-08 Cont ID  
Sent By pleduc Date 2021-10-08 Time   Rev Time 0.00
Received By pleduc Date 2021-10-08 Time 09:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-08-26 Cont ID  
Sent By pleduc Date 2021-08-26 Time   Rev Time 0.00
Received By pleduc Date 2021-08-26 Time 12:23 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2021-09-07 Cont ID  
Sent By lcrespo Date 2021-09-07 Time 09:45 Rev Time 0.00
Received By lcrespo Date 2021-09-07 Time 09:45 Sent To  
Notes
2021-09-07 09:37:54A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-12 Cont ID  
Sent By rmcphers Date 2021-10-12 Time 14:22 Rev Time 0.00
Received By rmcphers Date 2021-10-07 Time 16:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-21 Cont ID  
Sent By rmcphers Date 2021-09-21 Time 16:24 Rev Time 0.00
Received By rmcphers Date 2021-08-24 Time 13:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-10-12 Cont ID  
Sent By medwards Date 2021-10-12 Time 08:03 Rev Time 0.00
Received By medwards Date 2021-10-12 Time 08:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-08-27 Cont ID  
Sent By medwards Date 2021-08-27 Time 09:06 Rev Time 0.00
Received By medwards Date 2021-08-27 Time 09:06 Sent To  
Notes
2021-08-27 09:07:001ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21081169
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1.2: PLEASE EXPLAIN THE USE OF A FIRE DAMPER
 IN THE NEW 12/12 FRESH AIR TRANSFER DUCT FOR THE FIRE
 PUMP ROOM. ISN?T THE IDEAL TO HAVE OUTDOOR AIR TO THE
 PUMP WHEN IT IS RUNNING?
  
 2) SHEET M1.2: PLEASE EXPLAIN WHY THE NEW 12/12
 TRANSFER DUCT IS ONLY COMING FROM THE STORAGE ROOM
 T1004 AND NOT FROM THE OUTSIDE. THE AIR FOR THE PUMP
 ROOM SHOULD COME FROM THE EXTERIOR OF THE BUILDING.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-09-07 Cont ID  
Sent By lcrespo Date 2021-09-07 Time 09:37 Rev Time 0.00
Received By lcrespo Date 2021-09-07 Time 09:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-12 Cont ID  
Sent By rmcphers Date 2021-10-12 Time 14:21 Rev Time 0.00
Received By rmcphers Date 2021-10-12 Time 14:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-27 Cont ID  
Sent By medwards Date 2021-08-27 Time 09:09 Rev Time 0.00
Received By medwards Date 2021-08-27 Time 09:09 Sent To  
Notes
***NONE***