Plan Review Details - Permit 21081121
Plan Review Stops For Permit 21081121
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2021-08-20 Cont ID  
Sent By shill Date 2021-08-20 Time 14:37 Rev Time 0.00
Received By shill Date 2021-08-20 Time 14:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-08-16 Cont ID  
Sent By jleahy Date 2022-08-16 Time 09:35 Rev Time 0.00
Received By jleahy Date 2022-08-16 Time 08:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-07-07 Cont ID  
Sent By jleahy Date 2022-07-07 Time 08:13 Rev Time 0.00
Received By jleahy Date 2022-07-07 Time 07:12 Sent To  
Notes
2022-07-07 08:32:18FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E5.1 IS THE WRONG VERSION OF THE PLANS APPROVE
 UNDER ANOTHER REVISION.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2022-06-21 Cont ID  
Sent By pleduc Date 2022-06-21 Time   Rev Time 0.00
Received By pleduc Date 2022-06-21 Time 10:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2022-03-17 Cont ID  
Sent By pleduc Date 2022-03-17 Time   Rev Time 0.00
Received By pleduc Date 2022-03-17 Time 11:01 Sent To  
Notes
2022-03-17 12:06:45THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) NOW THAT THE SPECIFIC LOCATION HAS BEEN PROVIDED IT
 APPEAR TO BE IN CLOSE PROXIMITY TO THE GENERATOR AIR
 INTAKE WHICH MAY INDUCE HEATED AND TOXIC EXHAUST GAS
 BACK INTO THE GENERATOR.
  
 THE CONTINUED RUN LENGTH OF THE GENERATOR WITH CONSTANT
 HEATED EXHAUST MAY RENDER HIGHT TEMPAURATIRE AND
 RESULTANT FAILURE OF THE SYSTEM.
  
 PER NFPA 37
  
 8.2.3 EXHAUST SYSTEM TERMINATION.
 8.2.3.1* EXHAUST SYSTEMS SHALL TERMINATE OUTSIDE THE
 STRUCTURE
 AT A POINT WHERE HOT GASES, SPARKS, OR PRODUCTS OF
 COMBUSTION
 WILL DISCHARGE TO A SAFE LOCATION.
  
 A.8.2.3.1 EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER
 STRUCTURES
 (INCLUDING LOADING PLATFORMS) OR WHERE EXHAUST GAS
 ENTRAINMENT
 INTO VENTILATION INTAKES MIGHT OCCUR.
  
 7.7 HEATING, COOLING, AND VENTILATING.
 7.7.1* WITH THE EPS RUNNING AT RATED LOAD, VENTILATION
 AIRFLOW
 SHALL BE PROVIDED TO LIMIT THE MAXIMUM AIR TEMPERATURE
 IN THE
 EPS ROOM OR THE ENCLOSURE HOUSING THE UNIT TO THE
 MAXIMUM
 AMBIENT AIR TEMPERATURE REQUIRED BY THE EPS
 MANUFACTURER.
  
 PER NFPA 110
  
 7.10 EXHAUST SYSTEM.
 7.10.1 THE EXHAUST SYSTEM EQUIPMENT AND INSTALLATION,
 INCLUDING
 PIPING, MUFFLER, AND RELATED ACCESSORIES, SHALL BE IN
 ACCORDANCE WITH NFPA37, STANDARD FOR THE INSTALLATION
 AND USE OF
 STATIONARY COMBUSTION ENGINES AND GAS TURBINES, AND
 OTHER APPLICABLE
 STANDARDS.
 7.10.2 EXHAUST SYSTEM INSTALLATION SHALL BE GASTIGHT TO
 PREVENT
 EXHAUST GAS FUMES FROM ENTERING INHABITED ROOMS OR
 BUILDINGS
 AND TERMINATE IN SUCH A MANNER THAT TOXIC FUMES CANNOT
 REENTER A BUILDING OR STRUCTURE, PARTICULARLY THROUGH
 WINDOWS,
 AIR VENTILATION INLETS, OR THE ENGINE AIR-INTAKE
 SYSTEM.
  
  
 IT APPEARS THAT THE EXHAUST IS LOCATED WITHIN 5' TO 10'
 OF THE GENERATOR AIR INTAKE AND THE OPENING INTO THE
 PARKING GARAGE ON THE SAME WALL.
  
 THIS LOCATION APPEARS TO CONFLICT WITH THE CODE AND
 INTENT FOR A REMOTE EXHAUST LOCATION.
  
 THE PROVIDED MANUFACTURE'S SPECIFICATION SHEETS DO NOT
 INDICATE A RECOMMENDED DISTANCE.
  
 PLEASE REVIEW AND PROVIDE A DETAILED REVIEW OF THE
 DISTANCE FROM THE EHAUST TO BOTH THE GENERATOR AIR
 INTAKE AND THE OPENEING TO THE GARAGE
 CONTAINED IN THE MANUFACTURE'S INSTALLATION
 SPECIFICATION RECOMMENDATIONS AND/OR REQUIREMENTS.
  
 PLEASE INDICATE HOW THIS INSTALLATION MEETS THOSE
 REQUIRMENTS AND THE NFPA CODES.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2021-11-10 Cont ID  
Sent By pleduc Date 2021-11-10 Time   Rev Time 0.00
Received By pleduc Date 2021-11-10 Time 12:14 Sent To  
Notes
2021-11-10 12:31:24THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THE PROPOSED LOCATION DOES NOT INDICATE
 WINDOWS/OPENINGS THAT MAY ALLOW THE EXHAUST FUMES TO
 ENTER OCCUPIED AREAS.
  
 PER NFPA 37
  
 8.2.3 EXHAUST SYSTEM TERMINATION.
 8.2.3.1* EXHAUST SYSTEMS SHALL TERMINATE OUTSIDE THE
 STRUCTURE
 AT A POINT WHERE HOT GASES, SPARKS, OR PRODUCTS OF
 COMBUSTION
 WILL DISCHARGE TO A SAFE LOCATION.
  
 A.8.2.3.1 EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER
 STRUCTURES
 (INCLUDING LOADING PLATFORMS) OR WHERE EXHAUST GAS
 ENTRAINMENT
 INTO VENTILATION INTAKES MIGHT OCCUR.
  
  
 PER NFPA 110
  
 7.10 EXHAUST SYSTEM.
 7.10.1 THE EXHAUST SYSTEM EQUIPMENT AND INSTALLATION,
 INCLUDING
 PIPING, MUFFLER, AND RELATED ACCESSORIES, SHALL BE IN
 ACCORDANCE WITH NFPA37, STANDARD FOR THE INSTALLATION
 AND USE OF
 STATIONARY COMBUSTION ENGINES AND GAS TURBINES, AND
 OTHER APPLICABLE
 STANDARDS.
 7.10.2 EXHAUST SYSTEM INSTALLATION SHALL BE GASTIGHT TO
 PREVENT
 EXHAUST GAS FUMES FROM ENTERING INHABITED ROOMS OR
 BUILDINGS
 AND TERMINATE IN SUCH A MANNER THAT TOXIC FUMES CANNOT
 REENTER A BUILDING OR STRUCTURE, PARTICULARLY THROUGH
 WINDOWS,
 AIR VENTILATION INLETS, OR THE ENGINE AIR-INTAKE
 SYSTEM.
  
  
 PLEASE REVIEW AND PROVIDE HORIZONTAL AND VERTICAL
 OPENINGS AND THERE DISTANCES WITH INDICATIONS WHERE THE
 FUMES WOULD NOT ENTER OCCUPIED SPACES.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2021-10-22 Cont ID  
Sent By pleduc Date 2021-10-22 Time   Rev Time 0.00
Received By pleduc Date 2021-10-22 Time 16:39 Sent To  
Notes
2021-10-22 16:42:47THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE REMAINS NO INDICATION OF HOW OR WHERE THE
 EXHAUST THE EXHAUST IS LOCATED.
  
 PLEASE PROVIDE SPECIFIC DETAILS FOR THE EXHAUST SYSTEM
 AND WHERE IT WILL BE LOCATED TO THE EXTERIOR.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-09-03 Cont ID  
Sent By pleduc Date 2021-09-03 Time   Rev Time 0.00
Received By pleduc Date 2021-09-03 Time 13:13 Sent To  
Notes
2021-09-03 13:24:39THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE NO INDICATIONS OF THE LOCATION OF THE
 GENERATOR WITHIN THE SITE/BUILDING COMFIMR PREVIOS
 REVIEWS.
  
 FOR THE OFFICIAL RECORD PLEASE REVIEW AND PROVIDE THE
 LOCATION.
  
  
 1A) THERE ARE NO INDICATIONS OF THE LOCATION OF THE
 GENERATOR EXHAUST SHOWING COMPLIANCE WITH NFPA 110 & 37
  
 PLEASE REVIEW AND PROVIDE THE LOCATION, SIZE, AND
 INSTALLATION DETAILS IN COMPLIANCE OF THE CODE.
  
  
  
 1B) THERE ARE INDICATIONS OF NG FUEL SOURCE; HOWEVER,
 NO DETAILS OF FUEL LINE TYPE, LENGTH, LOCATION, ETC.,
 IN COMPLIANCE WITH NFPA 54 AND OTHER APPLICABLE NFPA
 CODES.
  
  
 PLEASE REVIEW AND PROVIDE DETAILS.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-08-16 Cont ID  
Sent By jleahy Date 2022-08-16 Time 09:35 Rev Time 0.00
Received By jleahy Date 2022-07-29 Time 12:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-07-07 Cont ID  
Sent By jleahy Date 2022-07-07 Time 08:39 Rev Time 0.00
Received By jleahy Date 2022-06-18 Time 07:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-03-18 Cont ID  
Sent By shill Date 2022-03-18 Time 08:42 Rev Time 0.00
Received By shill Date 2022-03-16 Time 09:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-11-29 Cont ID  
Sent By shill Date 2021-11-29 Time 12:35 Rev Time 0.00
Received By shill Date 2021-11-01 Time 08:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-22 Cont ID  
Sent By shill Date 2021-10-22 Time 17:55 Rev Time 0.00
Received By shill Date 2021-10-18 Time 14:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-27 Cont ID  
Sent By shill Date 2021-09-27 Time 10:20 Rev Time 0.00
Received By shill Date 2021-08-31 Time 12:28 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2022-08-16 Cont ID  
Sent By shill Date 2022-08-16 Time 09:35 Rev Time 0.00
Received By jleahy Date 2022-08-16 Time 09:35 Sent To  
Notes
2022-08-16 09:48:49PLANS STILL APPEAR TO BE COPIES OF ORIGINALS.
  
 DIGITAL PLANS NEED TO BE DIGITALLY SIGNED.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2022-06-25 Cont ID  
Sent By pvalenti Date 2022-06-25 Time 15:20 Rev Time 0.00
Received By pvalenti Date 2022-06-25 Time 14:45 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-09-24 Cont ID  
Sent By shill Date 2021-09-24 Time 10:26 Rev Time 0.00
Received By shill Date 2021-09-24 Time 10:26 Sent To  
Notes
2021-09-24 10:31:50****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FS553, THIS PROJECT IS PRIVATE PROVIDER PLAN REVIEW.
 PROVIDE AFFIDAVITS.
  
 2. SEE THE PROJECTDOX INSTRUCTIONS. IF YOU DO NOT HAVE
 THEM, EMAIL [email protected] AND REQUEST. TO
 FACILITATE PLAN REVIEW YOU MUST BREAK YOUR SUBMITTAL
 INTO LOGICAL PDFS. ONE 119 PAGE PDF IS VERY DIFFICULT
 FOR THE PLAN REVIEWERS TO REVIEW AND MAKES IT EXTREMELY
 DIFFICULT TO FIND INFORMATION. GENERATOR PERMIT
 APPLICATIONS TYPICALLY INCLUDE THE FOLLOWING SEPARATE
 PDFS AT A MINIMUM:
  
 DRAWING, SITE PLAN
 DRAWING, ELECTRICAL
 TIE DOWN ENGINEERING IF OUTDOORS
 SPEC SHEETS FOR GENERATOR
 TRANSFER SWITCH SPECS
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-08-19 Cont ID  
Sent By shill Date 2022-08-19 Time 11:55 Rev Time 0.00
Received By shill Date 2022-08-19 Time 11:55 Sent To  
Notes
2022-08-19 11:56:27EMAILED PRIVATE PROVIDER - ALL PLANS ARE TO EITHER BE
 FROM MASTER/REVISIONS AND WE HAVE THE ORIGINAL S&S ON
 FILE ALREADY, OR HE IS TO HAVE SOMEONE SUBMIT AS A
 SUBMITTAL.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-08-16 Cont ID  
Sent By jleahy Date 2022-08-16 Time 09:47 Rev Time 0.00
Received By jleahy Date 2022-08-16 Time 09:47 Sent To  
Notes
2022-08-16 11:46:40FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-07-07 Cont ID  
Sent By jleahy Date 2022-07-07 Time 08:38 Rev Time 0.00
Received By jleahy Date 2022-07-07 Time 08:37 Sent To  
Notes
2022-07-07 08:37:05FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-11-12 Cont ID  
Sent By lcrespo Date 2021-11-12 Time 16:35 Rev Time 0.00
Received By lcrespo Date 2021-11-12 Time 16:35 Sent To  
Notes
2021-11-12 16:38:17SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR -
 IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF THE ORIGINAL SIGNED AND
 SEALED DOCUMENT ALONG WITH A "PLAN REVIEW REQUEST FORM"
 EXPLAINING THE REASON FOR SUBMITTING THE DOCUMENT OR
 DRAWINGS. THE PLAN REVIEW REQUEST FORM CAN BE OBTAINED
 BY EMAILING [email protected] AND ASKING FOR THE FORM.

Review Stop Z ZONING
Rev No 1 Status N Date 2021-09-27 Cont ID  
Sent By aaponte Date 2021-09-27 Time 10:12 Rev Time 0.00
Received By aaponte Date 2021-09-27 Time 10:12 Sent To  
Notes
***NONE***