Plan Review Details - Permit 21081096
Plan Review Stops For Permit 21081096
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-11-02 Cont ID  
Sent By rbrown Date 2021-11-02 Time 20:44 Rev Time 0.00
Received By rbrown Date 2021-11-02 Time 20:44 Sent To  
Notes
2021-11-02 20:44:33PERMIT APPLICATION REVOKED. RECEIVED A LETTER FROM THE
 CONTRACTOR REQUESTING TO CANCEL THE PERMIT BECAUSE THE
 OWNER HAS ELECTED NOT TO MOVE FORWARD WITH THE WORK DUE
 TO THE REQUIREMENTS FOR COMPLIANCE WITH THE FAIR
 HOUSING ACT. RB

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-03 Cont ID  
Sent By pvalenti Date 2021-09-03 Time 10:54 Rev Time 0.00
Received By pvalenti Date 2021-09-03 Time 06:22 Sent To  
Notes
2021-09-03 11:33:12****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE PROVIDE MORE DETAILS FOR THE
 PROPOSED SHOWER AS PER THE FAIR HOUSING ACT INCLUDING:
 SEAT HEIGHT, WIDTH OF SHOWER DOOR OPENING, LOCATION OF
 SHOWER DOOR IN RELATION TO LOCATION OF SHOWER SEAT, &
 INDICATE ON PLAN THE 1/2" MAX. THRESHOLD INTO SHOWER.
  
 FBC B 2403.2, PLEASE PROVIDE THE DETAILS FOR NEW SHOWER
 GLASS PANEL CONNECTIONS TO SUPPORTS. TOP CONNECTION OF
 GLASS PANEL MAY BE REQUIRED.
  
 FBC B 107.2.1, SHEET A-1.0 NOTE # 7 STATES THERE WILL
 BE NEW TILE WITH UNDERLAYMENT. IF THE FLOOR TILE IS TO
 BE REPLACED, PLEASE PROVIDE DETAILED INFORMATION
 INCLUDING THE AREA THAT FLOORING IS TO BE REPLACED AND
 THE TESTING REPORTS FOR FLAME SPREAD AND SOUND AS PER
 FBC B 603.1, FBC B 1207.2, & FBC B 1207.3.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-10-25 Cont ID  
Sent By jleahy Date 2021-10-25 Time 14:14 Rev Time 0.00
Received By jleahy Date 2021-10-25 Time 14:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-09-29 Cont ID  
Sent By jleahy Date 2021-09-29 Time 10:14 Rev Time 0.00
Received By jleahy Date 2021-09-29 Time 10:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-05 Cont ID  
Sent By pleduc Date 2021-10-05 Time   Rev Time 0.00
Received By pleduc Date 2021-10-05 Time 11:01 Sent To  
Notes
2021-10-05 11:02:01FIRE COMMENTS
  
 PROTECT AND DO NOT PAINT OVER ANY
 EXISTING FIRE SPRINKLER HEADS.
  
 ALL SPRINKLER WORK SHALL BE DONE UNDER
 SEPARATE PERMIT & SHOP DRAWINGS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-09-08 Cont ID  
Sent By pleduc Date 2021-09-08 Time   Rev Time 0.00
Received By pleduc Date 2021-09-08 Time 15:21 Sent To  
Notes
2021-09-08 15:25:12FIRE COMMENTS
  
 PROTECT AND DO NOT PAINT OVER ANY
 EXISTING FIRE SPRINKLER HEADS.
  
 ALL SPRINKLER WORK SHALL BE DONE UNDER
 SEPARATE PERMIT & SHOP DRAWINGS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-03 Cont ID  
Sent By lmarchan Date 2021-11-03 Time 07:53 Rev Time 0.00
Received By lmarchan Date 2021-09-29 Time 14:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-29 Cont ID  
Sent By jleahy Date 2021-09-29 Time 10:14 Rev Time 0.00
Received By jleahy Date 2021-09-03 Time 07:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-10-13 Cont ID  
Sent By ccole Date 2021-10-13 Time 17:26 Rev Time 0.00
Received By ccole Date 2021-10-13 Time 16:47 Sent To  
Notes
2021-10-13 17:30:052ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21081096
 10/13/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 IST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN
 PARANTHESES.
  
 1) FAILED. SHEET A.1: FAIR HOUSING ACCESSIBILITY
 GUIDELINES: BECAUSE THE BUILDING WAS CONSTRUCTED IN
 ACCORDANCE WITH THE ACCESSIBILITY REQUIREMENTS OF THE
 FAIR HOUSING ACT AND THE DESIGN GUIDELINES FOR USABLE
 BATHROOMS IN DWELLING UNITS, THE ALTERATIONS THAT ARE
 PROPOSED IN THE BATHROOM SHALL ALSO BE IN COMPLIANCE
 WITH THE FAIR HOUSING ACT. THE FAIR HOUSING
 ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA
 ACCESSIBILITY CODE- 2017 SIXTH EDITION. REFER TO
 REQUIRMENT 7 USUABLE KITCHENS AND BATHROOMS AND PAGE
 7.33 IN THE FAIR HOUSING ACT DESIGN MANUAL.
 THE ARCHITECT SHALL SPECIFY WHICH USABLE BATHROOM
 SPECIFICATION TYPE A OR B WAS CHOSEN AS THE ORIGINAL
 DESIGN. PLEASE REFER TO PAGES 7.34- 7.39 OF THE FAIR
 HOUSING DESIGN ACT MANUAL FOR EXPLANATORY INFORMATION
 ON SPECIFICATION A & B. AN ENLARGED DIMENSIONED
 BATHROOM DRAWING WITH ELEVATION DETAILS WILL BE
 REQUIRED IN ORDER TO VERIFY COMPLIANCE FOR THE NEW
 FIXTURE INSTALLATIONS- SECTION 107.2.1 WPB. (PLEASE
 PROVIDE THE SPECIFICATION TYPE A OR B ON THE PLAN.)
  
 4) FAILED. BASED ON EITHER SPECIFICATION A OR B PLEASE
 REFER TO PAGES 6.12- 6.13 AND PROVIDE AND ELEVATION
 DETAIL SHOWING THE SHOWER CONTROLS LOCATION, AND THE
 GRAB BAR AND SEAT REINFORCEMENT DETAILS. SHOW THE
 LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF
 REINFORCEMENT MATERIAL TO BE USED. SEE SECTION 603.1
 FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS.
 (SHOWER CONTROLS LOCATION AND GRAB BAR REINFORCEMENT
 DETAILS NOT PROVIDED.)
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-09-24 Cont ID  
Sent By ccole Date 2021-09-24 Time 13:12 Rev Time 0.00
Received By ccole Date 2021-09-24 Time 12:19 Sent To  
Notes
2021-09-24 13:13:131ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21081096
 9/24/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A.1: FAIR HOUSING ACCESSIBILITY GUIDELINES:
 BECAUSE THE BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH
 THE ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT
 AND THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN
 DWELLING UNITS, THE ALTERATIONS THAT ARE PROPOSED IN
 THE BATHROOM SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017
 SIXTH EDITION. REFER TO REQUIRMENT 7 USUABLE KITCHENS
 AND BATHROOMS AND PAGE 7.33 IN THE FAIR HOUSING ACT
 DESIGN MANUAL.
  
 THE ARCHITECT SHALL SPECIFY WHICH USABLE BATHROOM
 SPECIFICATION TYPE A OR B WAS CHOSEN AS THE ORIGINAL
 DESIGN. PLEASE REFER TO PAGES 7.34- 7.39 OF THE FAIR
 HOUSING DESIGN ACT MANUAL FOR EXPLANATORY INFORMATION
 ON SPECIFICATION A & B. AN ENLARGED DIMENSIONED
 BATHROOM DRAWING WITH ELEVATION DETAILS WILL BE
 REQUIRED IN ORDER TO VERIFY COMPLIANCE FOR THE NEW
 FIXTURE INSTALLATIONS- SECTION 107.2.1 WPB.
  
 2) A-1: PLEASE REFER TO PAGES 7.47- 7.52 AND SHOW THE
 LAVATORY CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS AND
 KNEE AND TOE CLEARANCES. REFER TO PAGES 7.40- 7.46 AND
 PROVIDE THE WATER CLOSET CLEAR FLOOR SPACE DIAGRAM AND
 DIMENSION.
  
 3) A.1: PLEASE REFER TO PAGES 7.56- 7.59 OF THE MANUAL
 AND PROVIDE THE SHOWER CLEAR FLOOR SPACE DIAGRAM WITH
 DIMENSIONS.
  
 4) BASED ON EITHER SPECIFICATION A OR B PLEASE REFER TO
 PAGES 6.12- 6.13 AND PROVIDE AND ELEVATION DETAIL
 SHOWING THE SHOWER CONTROLS LOCATION, AND THE GRAB BAR
 AND SEAT REINFORCEMENT DETAILS. SHOW THE LENGTHS,
 WIDTHS AND HEIGHTS AND THE TYPE OF REINFORCEMENT
 MATERIAL TO BE USED. SEE SECTION 603.1 FOR ALLOWABLE
 MATERIALS IN NON-COMBUSTIBLE BUILDINGS.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-11-02 Cont ID  
Sent By rbrown Date 2021-11-02 Time 20:44 Rev Time 0.00
Received By rbrown Date 2021-11-02 Time 20:44 Sent To  
Notes
2021-11-02 20:45:12PERMIT APPLICATION REVOKED. RECEIVED A LETTER FROM THE
 CONTRACTOR REQUESTING TO CANCEL THE PERMIT BECAUSE THE
 OWNER HAS ELECTED NOT TO MOVE FORWARD WITH THE WORK DUE
 TO THE REQUIREMENTS FOR COMPLIANCE WITH THE FAIR
 HOUSING ACT. RB

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-09-03 Cont ID  
Sent By pvalenti Date 2021-09-03 Time 10:35 Rev Time 0.00
Received By pvalenti Date 2021-09-03 Time 10:35 Sent To  
Notes
2021-09-03 10:36:39****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 SIGNATURE REVIEW DENIED:
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  