Plan Review Details - Permit 21081037
| Plan Review Stops For Permit 21081037 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-13 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-13 |
Time |
16:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-09-28 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-28 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2021-09-28 14:40:11 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) 70 AMPERE TAP ON LOAD SIDE OF MAIN SHALL COMPLY WITH | | | 705.12 | | | | | | 705.12 (B) LOAD SIDE. THE OUTPUT OF AN INTERCONNECTED | | | ELECTRIC POWER SOURCE SHALL BE PERMITTED TO BE | | | CONNECTED TO THE LOAD | | | SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER | | | SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE | | | PREMISES. WHERE DISTRIBUTION | | | EQUIPMENT, INCLUDING SWITCHGEAR, SWITCHBOARDS, OR | | | PANELBOARDS, IS FED SIMULTANEOUSLY BY A PRIMARY | | | SOURCE(S) OF | | | ELECTRICITY AND ONE OR MORE OTHER POWER SOURCE(S), AND | | | WHERE THIS DISTRIBUTION EQUIPMENT IS CAPABLE OF | | | SUPPLYING MULTIPLE | | | BRANCH CIRCUITS OR FEEDERS, OR BOTH, THE | | | INTERCONNECTING PROVISIONS FOR OTHER POWER SOURCES | | | SHALL COMPLY WITH 705.12(B)(1) | | | THROUGH (B)(5). | | | | | | 2) BOX BELOW 200A PANEL ON RISER? WHAT IS IT FOR? | | | | | | 3) POLARIS TAPS IN METERMAIN COMBO? TAPPING WHAT? | | | | | | 4) IS VALUE $5K OR $55K ? |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-09-28 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-25 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-13 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-13 |
Time |
16:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-09-20 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-09-20 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |