Plan Review Details - Permit 21080967
Plan Review Stops For Permit 21080967
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-09-28 Cont ID  
Sent By cthroop Date 2021-09-28 Time 12:49 Rev Time 0.00
Received By cthroop Date 2021-09-28 Time 12:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-08 Cont ID  
Sent By cthroop Date 2021-09-08 Time 11:25 Rev Time 0.00
Received By cthroop Date 2021-09-08 Time 09:30 Sent To  
Notes
2021-09-08 11:32:14PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: PLAN PAGE S-1 INDICATES A ROOF COVERING OVER
 PROPOSED DECK. SEE COMMENTS UNDER ROOFING REVIEW.
  
 1. PROVIDE A COPY OF THE BOUNDRYLINE SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE DETAIL FOR MASS FOOTINGS AT PROPOSED DECK
 CLOUMN LOCATIONS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. PROVIDE DETAIL FOR WINDOW IN-FILL AND EXT. DOOR
 FRAMING.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 4. PROVIDE PRODUCT APPROVALS FOR PROPOSED EXT. DOORS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5. PROVIDE PRODUCT APPROVALS FOR PROPOSED TREK DECK.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2021-08-26 Cont ID  
Sent By fgiaquin Date 2021-08-26 Time 23:29 Rev Time 0.00
Received By fgiaquin Date 2021-08-26 Time 22:17 Sent To  
Notes
2021-08-26 22:29:45NO ELECTRICAL REVIEWED OR SUBMITTED.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-09-20 Cont ID  
Sent By fmittner Date 2021-09-20 Time 13:16 Rev Time 0.00
Received By fmittner Date 2021-09-20 Time 13:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-09 Cont ID  
Sent By lmarchan Date 2021-10-09 Time 17:23 Rev Time 0.00
Received By lmarchan Date 2021-10-08 Time 09:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-28 Cont ID  
Sent By cthroop Date 2021-09-28 Time 12:49 Rev Time 0.00
Received By cthroop Date 2021-09-24 Time 09:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-21 Cont ID  
Sent By lmarchan Date 2021-09-21 Time 10:56 Rev Time 0.00
Received By lmarchan Date 2021-08-19 Time 06:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-09-27 Cont ID  
Sent By medwards Date 2021-09-27 Time 09:28 Rev Time 0.00
Received By medwards Date 2021-09-27 Time 09:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-08-21 Cont ID  
Sent By medwards Date 2021-08-21 Time 06:18 Rev Time 0.00
Received By medwards Date 2021-08-21 Time 06:18 Sent To  
Notes
2021-08-21 06:21:491) IS THIS A LIKE FOR LIKE CHANGE OUT? IF SO PLEASE
 PROVIDE THE COMPLETED LIKE FOR LIKE CHANGE OUT FORM. IF
 THIS IS NOT A LIKE FOR LIKE CHANGE OUT PLEASE PROVIDE
 THE MECHANICAL EQUIPMENT SIZING CALCULATIONS.
  
 2) PLEASE SHOW THE OUTDOOR APPLIANCE TIE DOWN DETAILS.
 FBC RES M1307.2
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-09-27 Cont ID  
Sent By lcrespo Date 2021-09-27 Time 15:48 Rev Time 0.00
Received By lcrespo Date 2021-09-27 Time 15:48 Sent To  
Notes
2021-09-27 15:48:4809/27/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-08-25 Cont ID  
Sent By lcrespo Date 2021-08-25 Time 10:52 Rev Time 0.00
Received By lcrespo Date 2021-08-25 Time 10:52 Sent To  
Notes
2021-08-25 11:00:5708/25/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET S-1 WOULD YOU PLEASE PROVIDE SLAB REPAIR
 DETAIL FOR REVIEW. SHOW THE WIDTH OF THE REPAIR, THE
 MINIMUM THICKNESS OF THE CONCRETE TO BE REPLACED, AND
 THE PSI OF THE CONCRETE. SHOW THE SIZE AND LENGTH OF
 THE DOWELS, THE MINIMUM EMBEDMENT DEPTH INTO THE
 EXISTING SLAB, AND THE SPACING OF THE DOWELS IN THE
 CENTER. THE REPAIR SHALL ALSO INCLUDE TERMITE TREATMENT
 OF THE SOIL AND THE REQUIRED VAPOR BARRIER OVER THE
 SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE
 FOR A FINAL INSPECTION.
  
 2. ON SHEET P-1;
 A. THE WASHING MACHINE SHUT OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING OF THE UNITS AND WITHIN REACH
 PER THE 2020 FBC SEC. R 2903.9.3.
  
 B. HOT WATER LINES UNDERGROUND NOT IN CONDITION SPACE
 NEED TO BE INSULATED WITH A MINIMUM R-3 PER THE 2020
 FBC SEC. RE 403.5.3.
  
 C. THE WASHING MACHINE SHUT OFF VALVES SHALL BE
 ACCESSIBLE WITHOUT MOVING OF THE UNITS AND WITHIN REACH
 PER THE 2020 FBC SEC. R 2903.9.3.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2021-09-28 Cont ID  
Sent By cthroop Date 2021-09-28 Time 12:48 Rev Time 0.00
Received By cthroop Date 2021-09-28 Time 12:32 Sent To  
Notes
2021-09-28 12:49:11NO ROOFING UNDER THIS SOW. CT

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-09-08 Cont ID  
Sent By cthroop Date 2021-09-08 Time 11:20 Rev Time 0.00
Received By cthroop Date 2021-09-08 Time 10:56 Sent To  
Notes
2021-09-08 11:25:40PLAN REVIEW ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 NOTICE: PLAN PAGE S-1 INDICATES A ROOF WILL BE
 INSTALLED OVER PROPOSED DECK.
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 3. PROVIDE UNDERLAYMENT FOR PROPOSED ROOFING.
 R905.1.1
  
 OPTION:
 YOU MAY SUBMIT A STAND-ALONE ROOFING PERMIT. PLEASE
 ADVISE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2021-10-08 Time   Rev Time 0.00
Received By mpeterso Date 2021-10-08 Time 14:13 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-09-24 Cont ID  
Sent By ccole Date 2021-09-24 Time 17:16 Rev Time 0.00
Received By ccole Date 2021-09-24 Time 17:13 Sent To  
Notes
2021-09-24 17:18:032ND SIGNATURE REVIEW
 9/24/21
  
 1) SHEET S1 IS NOT SIGNED AND SEALED BY THE ENGINEER OF
 RECORD- FL. STATUTE 471.025, AND SECTION 61G15-23.002
 FAC. PLEASE SEE SIGNATURE FOR ADDITIONAL INFORMATION.
 SHEETS P1 & P2 ARE GOOD.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-09-08 Cont ID  
Sent By jleahy Date 2021-09-08 Time 09:55 Rev Time 0.00
Received By jleahy Date 2021-09-08 Time 09:55 Sent To  
Notes
2021-09-08 09:56:14PLANS SENT TO STORAGE JLEAHY

Review Stop Z ZONING
Rev No 1 Status P Date 2021-09-20 Cont ID  
Sent By fmittner Date 2021-09-20 Time 13:16 Rev Time 0.00
Received By fmittner Date 2021-09-20 Time 13:16 Sent To  
Notes
***NONE***