Plan Review Details - Permit 21080788
Plan Review Stops For Permit 21080788
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status N Date 2021-09-21 Cont ID  
Sent By pvalenti Date 2021-09-21 Time 15:37 Rev Time 0.00
Received By pvalenti Date 2021-09-21 Time 15:11 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-09-07 Cont ID  
Sent By pvalenti Date 2021-09-07 Time 09:19 Rev Time 0.00
Received By pvalenti Date 2021-09-07 Time 08:17 Sent To  
Notes
2021-09-07 09:30:43****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-09-29 Cont ID  
Sent By pvalenti Date 2021-09-29 Time 09:29 Rev Time 0.00
Received By pvalenti Date 2021-09-29 Time 09:29 Sent To  
Notes
2021-09-29 09:32:21PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW APPROVED W/PROVISO:
  
 NO EXTERIOR OR BEARING WALLS, COLUMNS,OR ROOF FRAMING
 MEMBERS WILL BE REMOVED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-09-21 Cont ID  
Sent By pvalenti Date 2021-09-21 Time 15:35 Rev Time 0.00
Received By pvalenti Date 2021-09-21 Time 15:11 Sent To  
Notes
2021-09-21 15:37:32****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561?805?6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
  
 FBC R 502.8 & 502.11.3, PLEASE CLARIFY, TRUSS/RAFTER
 NOTCHING AND/OR
 REPAIRS WILL NEED AN ENGINEER?S SIGNED/SEALED DETAIL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-07 Cont ID  
Sent By pvalenti Date 2021-09-07 Time 08:48 Rev Time 0.00
Received By pvalenti Date 2021-09-07 Time 08:17 Sent To  
Notes
2021-09-07 09:18:57****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, IT APPEARS THAT THIS IS NOT A COMPLETE
 DEMO BUT AN INTERIOR DEMO. PLEASE CLARIFY.
 FBC R 502.8 & 502.11.3, TRUSS/RAFTER NOTCHING AND/OR
 REPAIRS WILL NEED AN ENGINEER'S SIGNED/SEALED DETAIL.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2021-08-31 Cont ID  
Sent By rrossano Date 2021-08-31 Time   Rev Time  
Received By rrossano Date 2021-08-31 Time   Sent To  
Notes
2021-08-31 12:43:27 
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-09-07 Cont ID  
Sent By fmittner Date 2021-09-07 Time 15:32 Rev Time 0.00
Received By fmittner Date 2021-09-07 Time 15:32 Sent To  
Notes
2021-09-07 15:33:22INTERIOR DEMO ONLY PER DESCRIPTION AND
 CONFIRMATION/SITE VISIT WITH OWNER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-09-21 Cont ID  
Sent By pvalenti Date 2021-09-21 Time 15:37 Rev Time 0.00
Received By pvalenti Date 2021-09-21 Time 12:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-08 Cont ID  
Sent By lmarchan Date 2021-09-08 Time 08:56 Rev Time 0.00
Received By lmarchan Date 2021-08-17 Time 06:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-09-07 Cont ID  
Sent By pvalenti Date 2021-09-07 Time 09:19 Rev Time 0.00
Received By pvalenti Date 2021-09-07 Time 08:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-09-07 Cont ID  
Sent By fmittner Date 2021-09-07 Time 15:32 Rev Time 0.00
Received By fmittner Date 2021-09-07 Time 15:32 Sent To  
Notes
***NONE***