Plan Review Details - Permit 21080786
Plan Review Stops For Permit 21080786
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-08-17 Cont ID  
Sent By cpuell Date 2021-08-17 Time 16:12 Rev Time 0.00
Received By cpuell Date 2021-08-17 Time 16:12 Sent To  
Notes
2021-08-17 16:15:29SUITE 1510 IS ON CONSTRUCTION LEVEL 13 AND MARKETING
 LEVEL 15

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 10:18 Rev Time 0.00
Received By jwitmer Date 2021-10-19 Time 10:09 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-10-05 Cont ID  
Sent By jwitmer Date 2021-10-05 Time 07:12 Rev Time 0.00
Received By jwitmer Date 2021-09-08 Time 08:33 Sent To  
Notes
2021-10-05 07:12:16TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By jwitmer Date 2021-10-19 Time 10:22 Rev Time 0.00
Received By jwitmer Date 2021-10-19 Time 10:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-08 Cont ID  
Sent By jwitmer Date 2021-09-08 Time 09:48 Rev Time 0.00
Received By jwitmer Date 2021-09-08 Time 08:33 Sent To  
Notes
2021-09-08 09:48:37WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21080786
 ADD: 360 S. ROSEMARY AVE. # 1510
 CONT: HOLT LEE
 TEL: 954-725-4881
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 08/2021
 ACTION: DENIED
  
 1) SHEET AN-2-2 ACCESSIBILITY DIAGRAMS. DETAIL # 5
 TOILET FACILITIES INDICATES THE GRAB BARS AT 33 INCHES
 CENTERLINE ABOVE FINISH FLOOR. 2020 FBC-ACCESSIBILITY
 CODE SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS
 SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES
 MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR
 MEASURED TO THE TOP OF THE GRIPPING SURFACE, NOT
 CENTERLINE.
  
 2) TOILET ROOM DOORS. 2020 FBC-ACCESSIBILITY CODE
 FIGURE 604.8.1.6 SHOWS AN OUTSWING DOOR. PLEASE ALSO
 REVIEW SECTION 603.2.3. DOORS SHALL NOT SWING INTO THE
 CLEAR FLOOR SPACE OR CLEARANCES REQUIRED FOR ANY
 FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE
 REQUIRED TURNING SPACE. PLEASE SEE EXCEPTION 2. WHERE
 TOILET ROOMS ARE FOR INDIVIDUAL USE AND A CLEAR FLOORS
 SPACE COMPLYING WITH 305.3 IS PROVIDED WITHIN THE ROOM
 BEYOND THE ARC OF THE DOOR SWING. WHAT IS MISSING IS
 THE REQUIRED 30X48 INCH CLEAR FLOOR SPACE BEYOND THE
 ARC OF THE DOOR. USUALLY AT A 45% ANGLE TO THE DOOR
 ENTRANCE.
  
 3) SHEET A-1-0 THE BREAK ROOM WITH BREAK ROOM SINK DOES
 NOT INDICATE IF THE SINK IS A FORWARD APPROACH OR SIDE
 APPROACH.
 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING
 WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE
 AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED,
 SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED CLEAR FLOOR
 SPACE ON THE FLOOR PLAN. SHEET A-8-5 DETAIL 7 IT
 APPEARS TO BE A SIDE APPROACH PLEASE SHOW ON THE FLOOR
 PLAN.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-10-04 Cont ID  
Sent By jleahy Date 2021-10-04 Time 12:11 Rev Time 0.00
Received By jleahy Date 2021-10-04 Time 11:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-08-18 Cont ID  
Sent By pleduc Date 2021-08-18 Time   Rev Time 0.00
Received By pleduc Date 2021-08-18 Time 13:58 Sent To  
Notes
2021-08-18 16:01:25FIRE PROVISO:
  
 ALL FIRE SPRINKLER & FIRE ALARM WORK. INCLUDING DEMO,
 SHALL BE
 DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 THE CARD READER/ ACCESS CONTROL SHALL BE INSTALLED
 UNDER
 SEPARATE PERMIT & SHOP DRAWINGS
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-10-19 Time   Rev Time 0.00
Received By aoliver Date 2021-10-08 Time 07:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-10-05 Cont ID  
Sent By jwitmer Date 2021-10-05 Time 07:12 Rev Time 0.00
Received By jwitmer Date 2021-08-17 Time 09:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-08-31 Cont ID  
Sent By medwards Date 2021-08-31 Time 10:26 Rev Time 0.00
Received By medwards Date 2021-08-31 Time 10:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By ccole Date 2021-10-19 Time 17:52 Rev Time 0.00
Received By ccole Date 2021-10-19 Time 16:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-09-22 Cont ID  
Sent By ccole Date 2021-09-22 Time 11:19 Rev Time 0.00
Received By ccole Date 2021-09-22 Time 08:37 Sent To  
Notes
2021-09-22 11:19:331ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21080786
 9/22/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET AN-2-1 & A-7-1: PLEASE PROVIDE SITE SPECIFIC
 ACCESSIBILITY DETAILS PER THE FBC ACC. MISSING FROM THE
 DRAWINGS ON A-7-1:
 A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS-
 SECTION 604.3.
 B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES-
 SECTION 606.2.
 C) TURNING SPACE DIAMETERS- SECTION 304.3.
 D) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4,
 FIGURES 604.5.1 & 604.5.2.
 E) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 606.2 & FIGURES 306.2 & 306.3.
 F) HEIGHT OF THE ACCESSIBLE URINAL RIM FROM THE
 FINISHED FLOOR- SECTION 605.2.
 G) CLEAR FLOOR SPACE DIMENSIONS FOR THE ACCESSIBLE
 URINAL- SECTION 605.2.
  
 2) SHEET A-7-2 DETAIL 3: THE RIM OF THE NEW SINK
 APPEARS TO BE ABOVE THE MAXIMUM 34-INCH HEIGHT FORM THE
 FINISH FLOOR- SECTION 606.3 FBC ACC.
  
 3) A-7-2 & A-7-4: : SHOW THE HEIGHTS OF THE EQUIPMENT
 CONTROLS FROM THE FINISH FLOORS AND REACH RANGES AS
 DETAILED IN SECTIONS 308.1- 308.3 FBC ACC.
  
 4) P-0.0: PROVIDE PLUMBING FIXTURE CALCULATIONS FOR THE
 NEW TENANT BUILD-OUT IN ACCORDANCE WITH TABLE 403.1 FBC
 P. PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED NUMBER OF FIXTURES.
  
 5) P0.0: THE DUAL-OUTLET STOP VALVE DOES NOT MEET
 COMPLIANCE AS THE REQUIRED FULL-OPEN TYPE SHUTOFF VALVE
 REQUIRED FOR THE WATER HEATERS AT THE LAVATORIES-
 SECTION 503.1 & 606.1(8) FBC P.
  
 6) P0.0 & P1.0: COLD OR TEMPERED WATER SHALL BE
 DELIVERED FROM THE LAVATORIES- SECTION 419.5 FBC P. THE
 PLAN IS NOT IN COMPLIANCE.
  
 7) P1-0: IT APPEARS A FLOOR DRAIN IS MISSING AT THE ICE
 MAKER LOCATION- SECTION 107.2.1 WPB.
  
 8) P1-0: THE URINAL DRAINS SHALL CONNECT TO THE 3-INCH
 SANITARY AT A POINT DOWNSTREAM OF THE HORIZONTAL WET
 VENT FOR THE MEN'S BATHROOM GROUP- SECTION 912.1 FBC P.
 A COMMON VENT WILL BE REQUIRED FOR THE URINALS- SECTION
 911.1.
  
 9) P1-0: SHOW LOCATIONS OF WATER HAMMER ARRESTORS WHERE
 REQUIRED- SECTION 604.9 FBC P.
  
 10) P1-0: CLARIFY THE LOCATIONS OF REQUIRED BACKFLOW
 PREVENTERS FOR SUPPLY LINES TO THE DISHWASHER, ICE
 MAKER, COFFEE MAKER, WATER DISPENSERS ETC.- SECTION
 608.3 FBC P.
  
 11) P0.0 & P2.0: INDICATE THE MAKES AND MODELS OF THE
 PLUMBING FIXTURES IN THE SCHEDULE AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS FOR THE WALL HUNG FLUSH
 TANK TOILET- SECTION 303.4 FBC P.
  
 12) P1.0 & P2.0: SHOW THE LOCATION OF THE REQUIRED
 ACCESS PANEL FOR THE FLUSH TANK IN THE WALL- SECTION
 425.3.4 FBC P.
  
 13) P0.0: PROVIDE EQUIPMENT SCHEDULES FOR EQ-2, 5, 6, &
 7 AND SUBMIT MANUFACTURER'S SPECIFICATIONS- SECTION
 303.4.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-19 Cont ID  
Sent By ccole Date 2021-10-19 Time 17:52 Rev Time 0.00
Received By ccole Date 2021-10-19 Time 17:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-31 Cont ID  
Sent By medwards Date 2021-08-31 Time 10:31 Rev Time 0.00
Received By medwards Date 2021-08-31 Time 10:31 Sent To  
Notes
***NONE***