| Plan Review Stops For Permit 21080731 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-08-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-08-31 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-08-31 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2021-12-02 16:10:52 | 553.791, F.S. PRIVATE PROVIDER PLAN REVIEW COMPLIANCE | | | AFFIDAVIT. | | | PLEASE LIST ALL DOCUMENTS REVIEWED ON THE PLAN REVIEW | | | COMPLIANCE AFFIDAVIT. | | | ONLY DRAWING SHEETS ARE LISTED, BUT PRODUCT APPROVALS, | | | ENERGY CALS AND OTHER DOCUMENTS IN THE SUPPORTING | | | DOCUMENTS FOLDER SHOULD BE REVIEWED BY PRIVATE PROVIDER | | | SO THE CITY CAN DO AUDIT ONLY. | | | | | | ALSO, THIS PROPERTY IS IN A FLOOD ZONE. | | | THE CITY WILL DO THE NFIP REVIEW, BUT WE WILL NEED AN | | | ELEVATION CERTIFICATE. | | | | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | 2021-08-31 14:46:00 | ORIGINAL ADDRESS LEFT THE LOCATION OF THE MAIN ENTRANCE | | | DIDN'T CHANGE. A CABANA IS ON THE PROPERTY BUT ATTACHED | | | TO THE MAIN HOUSE AND UNDER THE SAME ROOM AND | | | ACCESSIBLE FROM THE MAIN HOUSE. NO ADDITIONAL ADDRESS | | | REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-15 |
Time |
06:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-14 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-06 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-06 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2022-07-06 11:24:45 | FINAL BUILDING REVIEW APPROVAL PENDING APPROVAL OF | | | CONSTRUCTION DRAWING ELEVATION CERTIFICATE. SEE | | | COMMENTS UNDER 4TH NFIP REVIEW DATED 7/6/2022. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-29 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2022-06-29 13:26:35 | FINAL BUILDING REVIEW APPROVAL PENDING APPROVAL OF | | | CONSTRUCTION DRAWING ELEVATION CERTIFICATE. SEE | | | COMMENTS UNDER 3RD NFIP REVIEW DATED 6/27/22. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-06 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-31 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2022-04-06 11:46:58 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS | | | SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6'0" | | | NAVD. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE | | | NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF | | | FREEBOARD. THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT | | | OR ABOVE 8'0" NAVD. | | | | | | 1. CORRECTED (FINISHED FLOOR ELEVATIONS PLACED ON FLOOR | | | PLAN, PAGE A100, ELEVATION PLANS A200 AND A201. FIRST | | | FLOOR SLAB IS 8.0' NAVD AND GARAGE FLOOR IS 6.6' NAVD). | | | | | | 2.THE GARAGE FLOOR IS BELOW THE DFE OF 8'0" NAVD. | | | (ADDITIONAL INFORMATION REQUIRED) | | | FLOOD OPENINGS ARE REQUIRED. | | | | | | ENGINEERED FLOOD VENTS | | | | | | 2A) ATTACH A COPY OF THE EVALUATION SERVICE REPORT | | | ISSUED BY THE INTERNATIONAL CODE COUNCIL EVALUATION | | | SERVICE (ICC ES). (DESIGNER SHALL IDENTIFY SMART VENT | | | MODEL TO BE INSTALLED) | | | 2B) PROVIDE FLORIDA PRODUCT APPROVALS FOR PROPOSED | | | SMART VENTS. (DESIGNER SHALL IDENTIFY SMART VENT MODEL | | | TO BE INSTALLED) | | | | | | 2C) FLOOD OPENINGS SHALL BE INSTALLED PER | | | R322.2.2.1INSTALLATION OF OPENINGS: (FOUNDATION PLAN S1 | | | SHOWS FLOOD VENTS INSTALLED ON SAME WALL) SEE BELOW FOR | | | LOCATION. | | | 2D) SHOW NUMBER AND LOCATION OF FLOOD OPENINGS ON FLOOR | | | PLAN. INCLUDE THE FLORIDA PRODUCT APPROVAL NUMBER AND | | | IDENTIFY THE VENT MODEL TO BE INSTALLED. (INCLUDED THE | | | SQUARE INCH/SQUARE FOOT DATA) | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN | | | 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN | | | DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. | | | | | | | | | 3.CORRECTED. CONSTRUCTION DRAWING ELEVATION CERTIFICATE | | | SUBMITTED FOR REVIEW. | | | | | | | | | 4. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 (NOT | | | SUBMITTED FOR REVIEW) | | | | | | | | | 5. PROVIDE A SOILS REPORT. (NOT SUBMITTED FOR REVIEW) | | | | | | | | | 6. REF. WINDOW SCHEDULE: CORRECTED | | | | | | | | | 7. PROVIDE PRODUCT APPROVALS FOR EXT. DOORS: (NOT | | | SUBMITTED FOR REVIEW) | | | | | | | | | 8. DESIGNER SPECIFIES CEILING INSULATION SHALL BE | | | ICYNENE SPRAY FOAM INSULATION WITH A VALUE OF R-30. | | | (PLAN PAGE A302). ENERGY SUBMITTAL USES A CEILING | | | R-VALUE OF R-20. PLEASE CLARIFY? | | | (NOT ADDRESSED) | | | | | | 9. DESIGNER SPECIFIES CMU WALL INSULATION SHALL HAVE A | | | R-VALUE OF R-11. (PLAN PAGE A303). ENERGY SUBMITTAL | | | USES A CMU WALL R-VALUE OF R-20. PLEASE CLARIFY? | | | (NOT ADDRESSED) | | | | | | 10. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY | | | FOAM INSULATION. (NOT SUBMITTED FOR REVIEW) | | | | | | NEW COMMENTS: | | | | | | RE: CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC) | | | COMMENTS PER FB107. | | | | | | 1. SECTION AA) GARAGE SQUARE FOOTAGE STATES 575SF. PLAN | | | PAGE A100. STATES GARAGE IS 667SF. | | | 2. SECTION A9B) NUMBER OF FLOOD OPENINGS STATES N/A. | | | PLAN PAGE AOOO SHOWS 2 FLOOD OPENINGS. | | | 3. A9C) TOTAL NET AREA STATES N/A. THIS DATA WILL BE | | | FROM THE TYPE OF FLOOD VENTS INSTALLED. ENGINEERED OR | | | NON-ENGINEERED. | | | 4. SECTION A9D) ENGINEERED FLOOD OPENINGS STATES NO. IF | | | NON-ENGINEERED FLOOD OPENINGS ARE INSTALLED, PROVIDE A | | | DETAIL BY A QUALIFIED DESIGN PROFESSIONAL, SIGNED AND | | | SEALED. | | | 5. SECTION C2D) TOP OF GARAGE FLOOR STATES 7.7FT. PLAN | | | PAGE A100 STATES 6.6FT. | | | 6. C2E) LOWEST ELEVATION OF MACHINERY STATES N/A. | | | MACHINERY SERVICING THE BUILDING SHALL BE AT OR ABOVE | | | THE DFE OF 8.0FT NAVD. | | | 7. C2F) LOWEST ADJACENT GRADE. REQUIRED DATA NOT | | | AVAILABLE. SITE DRAINAGE PLAN HAS NOT BEEN SUBMITTED | | | FOR REVIEW. | | | 8. C2G) HIGHEST ADJACENT GRADE. REQUIRED DATA NOT | | | AVAILABLE. SITE DRAINAGE PLAN HAS NOT BEEN SUBMITTED | | | FOR REVIEW. | | | 9. SECTION D COMMENTS: TYPE OF EQUIPMENT AND LOCATION | | | REQUIRED. (SEE DIRECTIONS IN COMMENTS NARRATIVE BLOCK) | | | 10. ELEVATION CERTIFICATE IS MISSING PAGES 5 AND 6. | | | (PHOTOS). FEMA REQUIRES A COMPLETE EC. NOTE: NO PHOTOS | | | ARE REQUIRED FOR THE CONSTRUCTION DRAWING EC. | | | | | | | | | PROVISO: PLAN PAGE S1. SUBMIT AN UNDER CONSTRUCTION EC | | | AT PLACEMENT OF FIRST FLOOR. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-27 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2021-12-27 17:10:15 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE | | | IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6'0" NAVD. | | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 8'0" NAVD. | | | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | | SHALL READ AS FOLLOWS: | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE, RESIDENTIAL. | | | R322.2.1 ELEVATION REQUIREMENTS. | | | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | | IS HIGHER. | | | | | | 2.PLACE THE FINISHED FLOOR ELEVATION (FFE) OF THE MAIN | | | DWELLING UNIT AND THE ATTACHED GARAGE ON THE SITE PLAN, | | | THE FLOOR PLAN AND THE FOUNDATION PLAN. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3.THE GARAGE FLOOR IS BELOW THE DFE OF 8'0" NAVD. | | | FLOOD OPENINGS ARE REQUIRED. | | | R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | | ENCLOSED AREAS, INCLUDING CRAWL SPACES, THAT ARE BELOW | | | THE DESIGN FLOOD ELEVATION SHALL: | | | 1.BE USED SOLELY FOR PARKING OF VEHICLES, BUILDING | | | ACCESS OR STORAGE. | | | 2.BE PROVIDED WITH FLOOD OPENINGS THAT MEET THE | | | FOLLOWING CRITERIA AND ARE INSTALLED IN ACCORDANCE WITH | | | SECTION R322.2.2.1: | | | 3.THE TOTAL NET AREA OF NON-ENGINEERED OPENINGS SHALL | | | BE NOT LESS THAN 1 SQUARE INCH (645 MM2) FOR EACH | | | SQUARE FOOT (0.093 M2) OF ENCLOSED AREA WHERE THE | | | ENCLOSED AREA IS MEASURED ON THE EXTERIOR OF THE | | | ENCLOSURE WALLS, OR THE OPENINGS SHALL BE DESIGNED AS | | | ENGINEERED OPENINGS AND THE CONSTRUCTION DOCUMENTS | | | SHALL INCLUDE A STATEMENT BY A REGISTERED DESIGN | | | PROFESSIONAL THAT THE DESIGN OF THE OPENINGS WILL | | | PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD FORCES ON | | | EXTERIOR WALLS BY ALLOWING FOR THE AUTOMATIC ENTRY AND | | | EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.7.2.2 OF | | | ASCE 24. | | | 4.OPENINGS SHALL BE NOT LESS THAN 3 INCHES (76 MM) IN | | | ANY DIRECTION IN THE PLANE OF THE WALL. | | | 5.THE PRESENCE OF LOUVERS, BLADES, SCREENS AND | | | FACEPLATES OR OTHER COVERS AND DEVICES SHALL ALLOW THE | | | AUTOMATIC FLOW OF FLOODWATER INTO AND OUT OF THE | | | ENCLOSED AREAS AND SHALL BE ACCOUNTED FOR IN THE | | | DETERMINATION OF THE NET OPEN AREA. | | | | | | OPTION: | | | ENGINEERED FLOOD VENTS | | | 1) PROVIDE ENGINEERED FLOOD VENTS. (SMART VENTS) | | | 2) ATTACH A COPY OF THE INDIVIDUAL ENGINEERED FLOOD | | | VENT CERTIFICATION OR EVALUATION SERVICE REPORT ISSUED | | | BY THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE | | | (ICC ES). | | | 3) PROVIDE FLORIDA PRODUCT APPROVALS FOR PROPOSED SMART | | | VENTS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE | | | 9N-3 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. | | | 4) FLOOD OPENINGS SHALL BE INSTALLED PER | | | R322.2.2.1INSTALLATION OF OPENINGS: | | | 5) SHOW NUMBER AND LOCATION OF FLOOD OPENINGS ON | | | FOUNDATION PLAN. INCLUDE THE FLORIDA PRODUCT APPROVAL | | | NUMBER AND IDENTIFY THE VENT MODEL TO BE INSTALLED. | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN | | | 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN | | | DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. | | | | | | FEMA TECHNICAL BULLETIN #1 | | | LOCATION OF FLOOD OPENINGS | | | THE IRC AND IBC (BY REFERENCE TO ASCE 24) REQUIRE FLOOD | | | OPENINGS ON DIFFERENT SIDES OF EACH ENCLOSED AREA (IRC | | | R322.2.2.1) AND ?IN AT LEAST TWO WALLS OF EACH ENCLOSED | | | AREA? (ASCE 24, SECTION 2.7.3). | | | | | | 4.SUBMIT THE FOLLOWING THREE (3) ELEVATION CERTIFICATES | | | AS REQUIRED: | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | 5. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 6. PROVIDE A SOILS REPORT. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | | | | 7. REF. WINDOW SCHEDULE ON PLAN PAGE A550 FOR THE | | | FOLLOWING COMMENT: | | | PROVIDE WINDOW TYPE TO LEGEND. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 8. PROVIDE PRODUCT APPROVALS FOR EXT. DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 9. DESIGNER SPECIFIES CEILING INSULATION SHALL BE | | | ICYNENE SPRAY FOAM INSULATION WITH A VALUE OF R-30. | | | (PLAN PAGE A302). ENERGY SUBMITTAL USES A CEILING | | | R-VALUE OF R-20. PLEASE CLARIFY? | | | R402.1.2INSULATION AND FENESTRATION CRITERIA. | | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | | REQUIREMENTS OF TABLE R402.1.2, BASED ON THE CLIMATE | | | ZONE SPECIFIED IN CHAPTER 3. | | | | | | 10. DESIGNER SPECIFIES CMU WALL INSULATION SHALL HAVE A | | | R-VALUE OF R-11. (PLAN PAGE A303). ENERGY SUBMITTAL | | | USES A CMU WALL R-VALUE OF R-20. PLEASE CLARIFY? | | | R402.1.2INSULATION AND FENESTRATION CRITERIA. | | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | | REQUIREMENTS OF TABLE R402.1.2, BASED ON THE CLIMATE | | | ZONE SPECIFIED IN CHAPTER 3. | | | | | | 11. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY | | | FOAM INSULATION. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-29 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-06 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-31 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-29 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2021-12-29 09:24:52 | ELECTRICAL PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.AN ELECTRICAL SU-PERMIT IS REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2.THE LOAD CALCULATIONS ON PAGE E100 SHOW A TOTAL LOAD | | | OF 165 AMPS. THE TOTAL LOAD OF PANELBOARDS A & B ON | | | PAGE E102 IS 245 AMPS. PLEASE CLARIFY? | | | PROVIDE ACCURATE LOAD CALCULATIONS INCLUDING ALL LOADS | | | FOR THE SERVICE AS WELL AS THE LOAD CALCULATIONS FOR | | | THE INDIVIDUAL PANELS. NEC 220; FBC RE 3602.2. | | | | | | 3.LUMINAIRES | | | R404.1LIGHTING EQUIPMENT (MANDATORY). | | | NOT LESS THAN 75 PERCENT OF THE LAMPS IN PERMANENTLY | | | INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY | | | LAMPS OR NOT LESS THAN 75 PERCENT OF THE PERMANENTLY | | | INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY | | | HIGH-EFFICACY LAMPS. | | | EXCEPTION: LOW-VOLTAGE LIGHTING. | | | A NOTE ON THE PLAN WILL SUFFICE. FBC EC R404.1 | | | | | | 4. PROVIDE OUTLET AT FRONT OF UNIT. | | | E3901.7 OUTDOOR OUTLETS. | | | NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY | | | ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6 | | | FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE | | | INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH | | | DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL. | | | | | | 5. PROVIDE SMOKE ALARM AND C/O DETECTOR AT 1ST FLOOR | | | STAIRS. | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | | R315.1 CARBON MONOXIDE PROTECTION. | | | | | | 6. KITCHEN OUTLETS SHALL BE GFCI PROTECTED. | | | E3902.6 KITCHEN RECEPTACLES. | | | 125-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE RECEPTACLES | | | THAT SERVE COUNTERTOP SURFACES SHALL HAVE GROUND-FAULT | | | CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. | | | [210.8(A)(6)] | | | | | | 7. DISHWASHER OUTLET SHALL BE GFCI PROTECTED. | | | E3902.10 KITCHEN DISHWASHER BRANCH CIRCUIT. | | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION SHALL BE | | | PROVIDED FOR OUTLETS THAT SUPPLY DISHWASHERS IN | | | DWELLING UNIT LOCATIONS. [210.8(D)] | | | | | | 8. PROVIDE OUTLETS FOR OHD OPENERS IN GARAGE. | | | E3902.2 GARAGE AND ACCESSORY BUILDING RECEPTACLES. | | | 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE RECEPTACLES | | | INSTALLED IN GARAGES AND GRADE-LEVEL PORTIONS OF | | | UNFINISHED ACCESSORY BUILDINGS USED FOR STORAGE OR WORK | | | AREAS SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER | | | PROTECTION FOR PERSONNEL. [210.8(A)(2)] | | | | | | 9. R322.1.6PROTECTION OF MECHANICAL, PLUMBING AND | | | ELECTRICAL SYSTEMS. | | | ELECTRICAL SYSTEMS, EQUIPMENT AND COMPONENTS; HEATING, | | | VENTILATING, AIR CONDITIONING; PLUMBING APPLIANCES AND | | | PLUMBING FIXTURES; DUCT SYSTEMS; AND OTHER SERVICE | | | EQUIPMENT SHALL BE LOCATED AT OR ABOVE THE ELEVATION | | | REQUIRED IN SECTION R322.2 OR R322.3. IF REPLACED AS | | | PART OF A SUBSTANTIAL IMPROVEMENT, ELECTRICAL SYSTEMS, | | | EQUIPMENT AND COMPONENTS; HEATING, VENTILATING, AIR | | | CONDITIONING AND PLUMBING APPLIANCES AND PLUMBING | | | FIXTURES; DUCT SYSTEMS; AND OTHER SERVICE EQUIPMENT | | | SHALL MEET THE REQUIREMENTS OF THIS SECTION. SYSTEMS, | | | FIXTURES, AND EQUIPMENT AND COMPONENTS SHALL NOT BE | | | MOUNTED ON OR PENETRATE THROUGH WALLS INTENDED TO BREAK | | | AWAY UNDER FLOOD LOADS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-07 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-31 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-29 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2021-12-29 14:14:00 | PLAN REVIEW FUEL GAS | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: A GAS SUB-PERMIT IS REQUIRED. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2020 FBC FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2020 FBC FUEL GAS RES | | | SECS. G2413.4.1, G2413.4.2. | | | | | | 2. SUBMIT APPLICABLE GAS TABLES. | | | | | | 3. SUBMIT MANUFACTURERS SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH 2020 FBC FUEL GAS SEC.305.1 OR | | | 2020 FBC FUEL GAS RES. SEC. G2408.1. | | | | | | 4. SUBMIT GAS REGULATOR SPECIFICATIONS. 2020 FBC FUEL | | | GAS SEC.305.1 OR 2020 FBC FUEL GAS RES. SEC. G2408.1. | | | | | | 5. REGULATORS SHALL HAVE A UNION INSTALLED WITHIN 1 | | | FOOT OF EITHER SIDE OF THE REGULATOR FBC FG 410.2 | | | | | | 6. SUBMIT A COPY OF A HOUSE PLAN SHOWING THE LOCATION | | | OF ALL PROPOSED GAS APPLIANCES. WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 7. SUBMIT COMBUSTION AIR CALCULATIONS FOR THE PROPOSED | | | GAS APPLIANCES. WHERE IS COMBUSTION AIR PROVIDED BY THE | | | BUILDINGS MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. 2020 FGC | | | SEC.304.9.3 OR 2020 FBC R G2407.9.3. COMBINED | | | COMBUSTION AIR AND VENTILATION AIR SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-07-15 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-07-13 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-29 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-28 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-27 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-23 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-06-23 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-06-21 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2022-06-22 15:58:55 | NEW SITE PLAN, CIVILS | | | B, E, P, R, M, NFIP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-07 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-28 |
Time |
06:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-24 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-18 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-28 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-24 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-02-24 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-02-03 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2022-02-07 12:22:16 | ZONING PASSED ON 12/1/21. ON 2/3, MULTIPLE NEW SHEETS | | | WERE UPLOADED INCLUDING MECHANICAL, ELEVATIONS. ROUTED | | | BACK TO ZONING SH | | | SOME EXAMPLES - CVR, A000, A100,A101 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-29 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-06 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-02 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-12-02 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-11-09 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-09-03 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-26 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-07-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-04-08 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2022-07-29 13:23:14 | RECEIPT MU-2022-016012 - $2404.37 PAID | | 2022-04-08 10:02:30 | 4/8/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-16 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-16 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2021-08-16 13:01:49 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION WILL OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE EMAIL THE RECEIPT | | | TO [email protected]. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-29 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-06 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-31 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2022-04-06 14:37:07 | PLAN REVIEW MECHANICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. NOTICE ONLY: A MECHANICAL SUB-PERMIT IS REQUIRED. | | | | | | | | | 2. CORRECTED | | | | | | | | | 3. CORRECTED | | | | | | | | | 4. PROVIDE THE KITCHEN EXHAUST HOOD SPECIFICATIONS. | | | (NOT SUBMITTED FOR REVIEW) | | | | | | | | | 5. NOTICE ONLY: MECH. EQUIPMENT IN FLOOD ZONES. (SEE | | | ELEVATION CERTIFICATE SECTION C2E) | | | | | | | | | 6. CORRECTED | | | | | | | | | 7. THE BUILDING DESIGNER SPECIFIES CEILING INSULATION | | | VALUE TO BE R-30 AND THE EXT. CMU WALL INSULATION VALUE | | | TO BE R-11. THE ENERGY SUBMITTAL USES A CEILING R-VALUE | | | OF R-20 AND A CMU WALL R-VALUE OF R-4.1. PLEASE | | | CLARIFY? | | | (NOT CORRECTED) | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-29 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2021-12-29 08:49:55 | PLAN REVIEW MECHANICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. A MECHANICAL SUB-PERMIT IS REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN | | | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE | | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE | | | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. | | | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A | | | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING | | | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, | | | OR | | | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL | | | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE | | | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER | | | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 3. M1411.8 LOCKING ACCESS PORT CAPS. | | | REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL | | | BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS OR | | | SHALL BE OTHERWISE SECURED TO PREVENT UNAUTHORIZED | | | ACCESS. | | | | | | 4. PROVIDE THE KITCHEN EXHAUST HOOD SPECIFICATIONS. | | | M1503.3 KITCHEN EXHAUST RATES. | | | WHERE DOMESTIC KITCHEN COOKING APPLIANCES ARE EQUIPPED | | | WITH DUCTED RANGE HOODS OR DOWN-DRAFT EXHAUST SYSTEMS, | | | THE FANS SHALL BE SIZED IN ACCORDANCE WITH SECTION | | | M1507.4. | | | M1503.4 MAKEUP AIR REQUIRED. | | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | | 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE | | | MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A | | | RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. | | | | | | 5. MECH. EQUIPMENT IN FLOOD ZONES | | | CONDENSER SHALL BE INSTALLED AT OR ABOVE THE DESIGN | | | FLOOD ELEVATION (DFE). | | | FBC R M1401.5 AND FBC R 322.1.6 | | | M1401.5 FLOOD HAZARD. | | | IN FLOOD HAZARD AREAS AS ESTABLISHED BY TABLE | | | R301.2(1), HEATING AND COOLING EQUIPMENT AND APPLIANCES | | | SHALL BE LOCATED OR INSTALLED IN ACCORDANCE WITH | | | SECTION R322.1.6. | | | | | | 6. THE BUILDERS SIGNATURE IS REQUIRED ON THE ENERGY | | | PERFORMANCE LEVEL (EPL) DISPLAY CARD. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 7. THE BUILDING DESIGNER SPECIFIES CEILING INSULATION | | | VALUE TO BE R-30 AND THE EXT. CMU WALL INSULATION VALUE | | | TO BE R-11. THE ENERGY SUBMITTAL USES A CEILING R-VALUE | | | OF R-20 AND A CMU WALL R-VALUE OF R-4.1. PLEASE | | | CLARIFY? | | | ENERGY CALC?S - ALL PHYSICAL BUILDING DATA LISTED ON | | | THE FLORIDA ENERGY EFFICIENCY FORM R405-2020 NEEDS TO | | | BE CONFIRMED ON NEW BUILDING PLANS- SECTION 107.2.1 | | | WPB. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-15 |
Time |
06:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-14 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-06 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-06 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2022-07-06 11:34:49 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC) | | | COMMENTS PER FB107. | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 8. C2G) HIGHEST ADJACENT GRADE (HAG). REQUIRED. (DATA | | | ENTERED APPEARS TO BE INCORRECT. PLEASE REFERENCE SITE | | | DRAINAGE PLAN PAGE C-1 FOR DATA) | | | (HAG APPEARS TO BE 6.00'). | | | | | | | | | 11. C2B) DATA MISSING. | | | (THIS IS A 2 STORY STRUCTURE. 1ST FLOOR FF EL. IS 8'0" | | | NAVD. 2ND FLOOR EL. IS +12'0". C2(B) SHOULD BE 20'0" | | | NAVD). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-27 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-25 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2022-06-27 16:05:06 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC) | | | COMMENTS PER FB107. | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1. SECTION AA) GARAGE SQUARE FOOTAGE STATES 575SF. PLAN | | | PAGE A100. STATES GARAGE IS 667SF. | | | (PLAN REVIEW COMMENTS BY CARLOS CORDEO-LUZA STATES THE | | | GARAGE IS 647. ENTER CORRECT DATA ON LINE A9A) OF EC) | | | | | | 2. SECTION A9B) NUMBER OF FLOOD OPENINGS STATES N/A. | | | PLAN PAGE AOOO SHOWS 2 FLOOD OPENINGS. (NOT CORRECTED) | | | | | | 3. A9C) TOTAL NET AREA STATES N/A. THIS DATA WILL BE | | | FROM THE TYPE OF FLOOD VENTS INSTALLED. ENGINEERED OR | | | NON-ENGINEERED. (NOT CORRECTED) | | | | | | 4. SECTION A9D) ENGINEERED FLOOD OPENINGS STATES NO. IF | | | NON-ENGINEERED FLOOD OPENINGS ARE INSTALLED, PROVIDE A | | | DETAIL BY A QUALIFIED DESIGN PROFESSIONAL, SIGNED AND | | | SEALED. (INCORRECT DATA STILL ENETERD) | | | | | | 5. SECTION C2D) TOP OF GARAGE FLOOR STATES 7.7FT. PLAN | | | PAGE A100 STATES 6.6FT. (INCORRECT DATA STILL ENETERD) | | | | | | 6. C2E) LOWEST ELEVATION OF MACHINERY STATES N/A. | | | MACHINERY SERVICING THE BUILDING SHALL BE AT OR ABOVE | | | THE DFE OF 8.0FT NAVD. (ENTER CORRECT DATA) | | | | | | 7. C2F) LOWEST ADJACENT GRADE. REQUIRED. (DATA ENTERED | | | APPEARS TO BE INCORRECT. PLEASE REFERENCE SITE DRAINAGE | | | PLAN PAGE C-1 FOR DATA) | | | | | | 8. C2G) HIGHEST ADJACENT GRADE. REQUIRED. (DATA ENTERED | | | APPEARS TO BE INCORRECT. PLEASE REFERENCE SITE DRAINAGE | | | PLAN PAGE C-1 FOR DATA) | | | | | | 9. SECTION D COMMENTS: TYPE OF EQUIPMENT AND LOCATION | | | REQUIRED. (SEE DIRECTIONS IN COMMENTS NARRATIVE BLOCK) | | | (NOT ADDRESSED) | | | | | | 10. | | | | | | PROVISO: PLAN PAGE S1 - UNDER CONSTRUCTION EC REQUIRED | | | AT PLACEMENT OF 1ST FLOOR. | | | | | | C/O HOLD: FINISHED CONSTRUCTION EC REQUIRED PRIOR TO | | | C/O. | | | | | | NEW COMMENT: | | | | | | 11. C2B) DATA MISSING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-06 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-31 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2022-04-06 13:56:09 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC) | | | COMMENTS PER FB107. | | | | | | 1. SECTION AA) GARAGE SQUARE FOOTAGE STATES 575SF. PLAN | | | PAGE A100. STATES GARAGE IS 667SF. | | | 2. SECTION A9B) NUMBER OF FLOOD OPENINGS STATES N/A. | | | PLAN PAGE AOOO SHOWS 2 FLOOD OPENINGS. | | | 3. A9C) TOTAL NET AREA STATES N/A. THIS DATA WILL BE | | | FROM THE TYPE OF FLOOD VENTS INSTALLED. ENGINEERED OR | | | NON-ENGINEERED. | | | 4. SECTION A9D) ENGINEERED FLOOD OPENINGS STATES NO. IF | | | NON-ENGINEERED FLOOD OPENINGS ARE INSTALLED, PROVIDE A | | | DETAIL BY A QUALIFIED DESIGN PROFESSIONAL, SIGNED AND | | | SEALED. | | | 5. SECTION C2D) TOP OF GARAGE FLOOR STATES 7.7FT. PLAN | | | PAGE A100 STATES 6.6FT. | | | 6. C2E) LOWEST ELEVATION OF MACHINERY STATES N/A. | | | MACHINERY SERVICING THE BUILDING SHALL BE AT OR ABOVE | | | THE DFE OF 8.0FT NAVD. | | | 7. C2F) LOWEST ADJACENT GRADE. REQUIRED DATA NOT | | | AVAILABLE. SITE DRAINAGE PLAN HAS NOT BEEN SUBMITTED | | | FOR REVIEW. | | | 8. C2G) HIGHEST ADJACENT GRADE. REQUIRED DATA NOT | | | AVAILABLE. SITE DRAINAGE PLAN HAS NOT BEEN SUBMITTED | | | FOR REVIEW. | | | 9. SECTION D COMMENTS: TYPE OF EQUIPMENT AND LOCATION | | | REQUIRED. (SEE DIRECTIONS IN COMMENTS NARRATIVE BLOCK) | | | 10. ELEVATION CERTIFICATE IS MISSING PAGES 5 AND 6. | | | (PHOTOS). FEMA REQUIRES A COMPLETE EC. NOTE: NO PHOTOS | | | ARE REQUIRED FOR THE CONSTRUCTION DRAWING EC. | | | | | | PROVISO: PLAN PAGE S1 - UNDER CONSTRUCTION EC REQUIRED | | | AT PLACEMENT OF 1ST FLOOR. | | | | | | C/O HOLD: FINISHED CONSTRUCTION EC REQUIRED PRIOR TO | | | C/O. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2021-12-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-28 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2021-12-28 09:25:16 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE | | | IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6?0? NAVD. | | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 8?0? NAVD. | | | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | | SHALL READ AS FOLLOWS: | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE, RESIDENTIAL. | | | R322.2.1 ELEVATION REQUIREMENTS. | | | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | | IS HIGHER. | | | | | | 2.SUBMIT THE FOLLOWING THREE (3) ELEVATION CERTIFICATES | | | AS REQUIRED. | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-29 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-07 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-31 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-29 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2021-12-29 14:13:09 | PLAN REVIEW PLUMBING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: A PLUMBING SUB-PERMIT IS REQUIRED. | | | | | | 1. CORRECT BUILDING CODE REFERENCE ON PLAN PAGE P102 | | | FROM FBC 2017 TO FBC 2020. | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2. PROVIDE SHOWER PAN DETAIL. | | | P2709.1 SHOWER PAN CONSTRUCTION. FBC 107.2.1 | | | P2709.3 SHOWER PAN LINING INSTALLATION. | | | | | | 3. MASTER BATH GROUP IS ON A CLOSED VENT SYSTEM. | | | P3101.2.1VENTING REQUIRED. | | | EVERY TRAP AND TRAPPED FIXTURE SHALL BE VENTED IN | | | ACCORDANCE WITH ONE OF THE VENTING METHODS SPECIFIED IN | | | THIS CHAPTER. | | | P3108.2.2VERTICAL WET VENT. | | | THE DRY-VENT CONNECTION FOR A VERTICAL WET-VENT SYSTEM | | | SHALL BE AN INDIVIDUAL VENT OR COMMON VENT FOR THE MOST | | | UPSTREAM FIXTURE DRAIN. | | | P3102.2INSTALLATION. | | | THE REQUIRED VENT SHALL BE A DRY VENT THAT CONNECTS TO | | | THE BUILDING DRAIN OR AN EXTENSION OF A DRAIN THAT | | | CONNECTS TO THE BUILDING DRAIN. SUCH VENT SHALL NOT BE | | | AN ISLAND FIXTURE VENT AS PERMITTED BY SECTION P3112. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
9 |
Status |
P |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-07-20 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-07-20 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2022-07-21 16:49:54 | REVISED AFFIDAVIT RECEIVED, ADDED AND APPROVED. | | 2022-07-21 08:35:15 | PLAN COMPLIANCE AFFIDAVIT | | | WHERE IT SAYSFINAL ELEVATION CERTIFICATE COULD YOU | | | PLEASE HAVE THAT SAY CONSTRUCTION DRAWINGS ELEVATION | | | CERTIFICATE. | | 2022-07-20 16:22:57 | ADDED AFFIDAVIT WITH EC |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
8 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-15 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-14 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2022-07-15 09:45:50 | PRIVATE PROVIDER SHALL SUBMIT A CORRECTED AFFIDAVIT | | | UPON APPROVAL OF THE CONSTRUCTION DRAWING ELEVATION | | | CERTIFICATE, PER BUILDING OFFICIAL (RB). CT |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
7 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-29 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
6 |
Status |
F |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-25 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-24 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2022-06-27 15:16:15 | PROVITE PROVIDER AFFIDAVIT REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 6TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: AFFIDAVIT SUBMITTED ON 6/21/22 HAS ONLY THOSE | | | DOC'S THAT ADDRESS THE BLDG., MECH., AND NFIP REVIEW | | | COMMENTS. | | | | | | CORRECTION: | | | | | | 1. AFFIDAVITS MAY BE MULTIPLE DOC'S PER STATUTE. SEE | | | 7TH REVIEW. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
5 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-03-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2022-03-29 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
4 |
Status |
F |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-24 |
Time |
06:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-24 |
Time |
06:05 |
Sent To |
|
|
| Notes |
| 2022-03-24 07:00:47 | PRIVATE PROVIDER AFFIDAVIT AUDIT- | | | THE AFFIDAVIT HAS THE FOLLOWING MISTAKES- M-2 IS DATED | | | 07/09/2021 AND HAS NOT HAD A REVISION 1 AS SHOWN ON THE | | | AFFIDAVIT; THERE IS NO SHEET A1000 2ND REVISION DATED | | | 1/12/2022, THERE IS A SHEET A100 WITH THIS DATE. | | | PLEASE SUBMIT THE CORRECTED AFFIDAVIT PER F.S. 553.791 |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-28 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-28 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2022-02-28 15:06:12 | THE PRIVATE PROVIDER AFFIDAVIT SHOULD INCLUDE | | | EVERYTHING THAT IS SUBMITTED. THE PRIVATE PROVIDER | | | AFFIDAVIT IS A SWORN TESTIMONY THAT THEY HAVE REVIEWED | | | THE ENTIRE PROJECT. EACH TIME THERE IS A CHANGE IN THE | | | SUBMITTALS AND A NEW AFFIDAVIT IS REQUIRED IT WILL TAKE | | | THE PLACE OF THE PREVIOUS VERSION OF THE AFFIDAVIT AND | | | SHOULD LIST EVERYTHING THAT HAS BEEN REVIEWED FOR THE | | | PROJECT INCLUDING PIECES OF THE SUBMITTALS THAT HAVE | | | NOT CHANGED AND THE REVISED DOCUMENTS. THE DATES OF | | | EACH DOCUMENT AND THE REVISION NUMBERS SHOULD ALWAYS BE | | | INCLUDED. THE FINAL AFFIDAVIT SHOULD BE A STAND ALONE | | | DOCUMENT THAT SHOWS THE HISTORY OF THE SUBMITTAL. | | | PLEASE INCLUDE THE FOLLOWING DOCUMENTS WITH DATES AND | | | REVISIONS TO YOUR AFFIDAVIT: | | | | | | ENERGY CALCULATIONS | | | | | | MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | | | | ELEVATION CERTIFICATE | | | | | | ARCHITECTURAL SHEETS: A102, A300, A301, A304, A305, | | | A500, A501, A550, A551, | | | | | | STRUCTURAL SHEETS; S1, S2, S3, S4, S5, S6, S7, S8 | | | | | | PLUMBING SHEETS: P101, P103, P104, P105, P106 | | | | | | ELECTRICAL: E102 | | | | | | SURVEY SHEET | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-12-06 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-12-06 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2021-12-02 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-12-02 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-12-02 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2021-12-03 16:48:23 | 553.791, F.S. PRIVATE PROVIDER PLAN REVIEW COMPLIANCE | | | AFFIDAVIT. | | | PLEASE PROVIDE UPDATED PLAN REVIEW COMPLIANCE AFFIDAVIT | | | TO INCLUDE ALL DOCUMENTS REVIEWED INCLUDING PRODUCT | | | APPROVALS, ENERGY CALCS AND ANY REVIEWED DOCUMENTS. | | | THE CITY OF WPB WILL BE PERFORMING AUDIT ONLY SO WE | | | NEED TO SEE THAT PRIVATE PROVIDER DID THE REVIEWS. | | | | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-06 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-31 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2022-04-06 11:49:36 | ROOFING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1ST REVIEW COMMENTS HAVE NOT BEEN ADDRESSED. SEE BELOW. | | | | | | 1. ROOFING SUB-PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE INSTALLATION INSTRUCTIONS FOR FL14317-R12, | | | ROOFING UNDERLAYMENTS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 3. ONLY THE COVER SHEETS WERE SUBMITTED FOR FL7849-R14, | | | ROOFING TILES. | | | DESIGNER SHALL SELECT THE MODEL, NAME OR NUMBER OF TILE | | | TO BE INSTALLEED. PROVIDE INSTALLATION INSTRUCTIONS FOR | | | TILE SELECTED. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-12-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-27 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2021-12-27 15:37:01 | ROOFING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING SUB-PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE INSTALLATION INSTRUCTIONS FOR FL14317-R12, | | | ROOFING UNDERLAYMENTS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 3. ONLY THE COVER SHEETS WERE SUBMITTED FOR FL7849-R14, | | | ROOFING TILES. | | | DESIGNER SHALL SELECT THE MODEL, NAME OR NUMBER OF TILE | | | TO BE INSTALLEED. PROVIDE INSTALLATION INSTRUCTIONS FOR | | | TILE SELECTED. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
7 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-15 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-14 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2022-07-15 09:43:13 | DIGITAL SIGNATURE AND SEAL BY SURVEYOR IS NOT REQUUIRED | | | ON A CONSTRUCTION DRAWING EC. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-06 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-06 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2022-07-06 11:22:51 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ELEVATION CERTIFICATE SHALL HAVE A VALID DIGITAL | | | SIGNATURE OF THE SURVEYOR. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-27 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-25 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2022-06-27 09:23:39 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW: | | | | | | (3) SETS OF PAPER PLAN SHEETS: A-000, A-100, A-201, | | | A-300, A-302, A-303, A-304, A-305, P-100, P-103, E-100, | | | & S-1 HAVE BEEN SUBMITTED WITH ORIGINAL HAND SIGNATURES | | | BY REGISTERED ARCHITECT ANGELO DAVILA. THESE PAPER PLAN | | | SHEETS HAVE BEEN ROUTED TO RECORDS RETENTION SPECIALIST | | | (C.D.) FOR STORAGE. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-07 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-07 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-11-22 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-11-22 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-22 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2021-11-22 16:46:19 | REVIEW OF SIGNATURE AND SEAL ON PAPER PLANS APPROVED, | | | ROUTED TO STORAGE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-11-12 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-11-12 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-11-12 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2021-11-12 16:20:26 | PLANS WHERE SUBMITED WITH A WET SEAL FRO VERSION TWO | | | AND ONLY A000, A200, A201 AND A202 HAS BEEN APPROVED | | | ALL OTHER PAGES NEED A SIGNATURE OR SEAL IN ACCORDANCE | | | WITH FLORIDA ADMINISTRATIVE CODE PER 61G15-23.001, | | | FLORIDA STATUTE 471. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-11-12 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-11-12 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-11-12 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2021-11-12 16:17:45 | ALL PAGES WITH NO ELECTRONIC SIGNATURE, A COPY OF THE | | | SIGNATURE OR SEAL IS NOT IN ACCORDANCE WITH FLORIDA | | | ADMINISTRATIVE CODE PER 61G15-23.001, |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-06-23 |
Time |
17:05 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2022-06-23 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2022-06-23 17:05:52 | ADDITIONAL SEPARATE PERMITS ARE REQUIRED FOR THE | | | FOLLOWING ITEMS: | | | | | | A. POOL, INCLUDING POOL EQUIPMENT. | | | B. DRIVEWAY, INCLUDING APPROACH. | | | C. LANDSCAPE AND IRRIGATION. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-02-24 |
Time |
16:55 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-02-24 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2022-02-24 16:58:29 | ADDITIONAL SEPARATE PERMITS ARE REQUIRED FOR THE | | | FOLLOWING ITEMS: | | | | | | A. POOL, INCLUDING POOL EQUIPMENT. | | | B. DRIVEWAY, INCLUDING APPROACH. | | | C. LANDSCAPE AND IRRIGATION. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-12-01 |
Time |
12:52 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2021-11-19 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2021-11-19 12:07:24 | ADDITIONAL SEPARATE PERMITS ARE REQUIRED FOR THE | | | FOLLOWING ITEMS: | | | | | | A. POOL, INCLUDING POOL EQUIPMENT. PLEASE NOTE THAT THE | | | POOL EQUIPMENT "BOX" AS SHOWN IS ENCROACHING INTO THE | | | CORNER SIDE SETBACK. THE FURTHEST PROJECTION OF THE | | | EQUIPMENT AND/OR PAD MAY BE NO CLOSER THAN 8.5 FEET | | | FROM THE CORNER SIDE PROPERTY LINE. | | | B. DRIVEWAY, INCLUDING APPROACH. | | | C. LANDSCAPE AND IRRIGATION. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
eshneide |
Date |
2021-09-03 |
Time |
13:15 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2021-09-03 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2021-09-03 13:15:42 | FAILED | | | | | | PROVIDE WRITTEN RESPONSE TO COMMENTS. | | | | | | 1) PRIOR TO THE ZONING APPROVAL OF THIS PERMIT A | | | SEPARATE LANDSCAPE PERMIT AND AN IRRIGATION PERMIT MUST | | | BE SUBMITTED TO THE BUILDING DIVISION. | | | | | | 2) SUBMIT A CURRENT SURVEY, LESS THAT A YEAR OLD, OF | | | THE PROPERTY. THE SITE PLAN DIMENSIONS SHALL MATCH THE | | | SURVEY DIMENSIONS. | | | | | | 3) THE LOT IS SHOWN WITH A CURVE AT THE CORNER OF | | | GREGORY AND ARLINGTON. THE FRONT SETBACK FOLLOWS THE | | | CURVE AS THE IT IS MEASURED FROM THE PROPERTY LINE TO | | | THE CLOSEST POINT TO THE HOUSE. THE NORTHWEST CORNER OF | | | THE HOUSE IS CLOSER THAN 25 FEET TO THE CURVED PORTION | | | OF THE FRONT PROPERTY LINE, WHICH IS NOT PERMITTED. | | | | | | 4) PLEASE PROVIDE THE BUILDING HEIGHT AS DEFINED BY THE | | | CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS - BUILDING, HEIGHT OF, MEANS THE VERTICAL | | | DISTANCE FROM THE MEAN GRADE OF A LOT AT THE FRONTAGE | | | OF THE BUILDING TO THE HIGHEST POINT OF THE TOP OF THE | | | STRUCTURE OF A FLAT ROOF, OR TO THE DECK LINE OF A | | | MANSARD ROOF, OR TO THE MID-HEIGHT LEVEL BETWEEN EAVES | | | AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. YOU HAVE | | | ONLY PROVIDED THE HEIGHT FROM THE FINISHED FLOOR. | | | | | | 5) ADDITIONAL SEPARATE PERMITS ARE REQUIRED FOR THE | | | FOLLOWING ITEMS: | | | | | | A. POOL, INCLUDING POOL EQUIPMENT. | | | B. DRIVEWAY, INCLUDING APPROACH. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|