| Plan Review Stops For Permit 21080730 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-17 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-17 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-01-11 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-01-11 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2022-01-11 11:08:29 | RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21080730 | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | | ISSUANCE. | | | | | | ****ALL DRAWINGS NEED TO BE PROPERLY SIGNED AND SEALED | | | BEFORE PROVISO. | | | | | | | | | ORIGINAL COMMENT: | | | 1- DRAWINGS WERE NOT SIGNED AND SEALED BY THE ARCHITECT | | | AND ENGINEER OF RECORD. ALL DRAWINGS NEED TO BE SIGNED | | | AND SEALED AS REQUIRED BY CHAPTER 481 F.S. AND CHAPTER | | | 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC | | | RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH | | | ARCHITECT'S/ENGINEER'S DIGITAL SIGNATURE OR PROVIDE | | | HARD COPY PLANS WITH ARCHITECT'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | RESPONSE: | | | THE FOLLOWING DRAWINGS WERE NOT SIGNED & SEALED: C-01, | | | SP-01, A-00, A-02, A-03, A-04, S1, S3, S4, S5. | | | | | | 2- OK. | | | 3- OK. | | | 4- OK. | | | | | | 5-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)OK. | | | | | | ORIGINAL COMMENT: | | | B)HIP & RIDGE METAL SUPPORT TO BE USED. AND, CLEARLY | | | MARK SPECIFIC METAL CHANNEL TO BE INSTALLED. SEE | | | PERFORMANCE LIMITATIONS TABLES ON PRODUCT APPROVAL | | | SUBMITTED. | | | | | | RESPONSE: | | | NOT SUBMITTED. | | | | | | ORIGINAL COMMENT: | | | C)ROOF UNDERLAYMENT FL14317-R12 SUBMITTED: CLEARLY MARK | | | WHICH TESTED ASSEMBLY IS GOING TO BE INSTALLED. SEE | | | SEC. 5.8.2 AND SEC. 5.8.3 OF PRODUCT APPROVAL | | | SUBMITTED. | | | THERE ARE 6 ASSEMBLIES. SPECIFY WHICH ASSEMBLY FROM | | | SEC. 5.8.3.1 IS GOING TO BE INSTALLED. | | | | | | RESPONSE: | | | STILL NOT CLEAR WHICH ASSEMBLY TO BE USED. TABLE 2 ON | | | PAGE 4 OF 6 OF PRODUCT APPROVAL WAS MARKED, BUT IT | | | DOESN'T CLARIFY IF USING ASTM D226 TYPE II FELT OR | | | CITADEL PLUS AS THE SUBSTRATE. I F USING ASTM D226 FELT | | | , THEN PROVIDE FRSA/TRI PRESCRIPTIVE METHOD USED. IF | | | USING CITADEL PLUS , THEN CIRCLE WHICH ASSEMBLY IS | | | GOING TO BE USED. SEE SEC. 5.8.2 OF PRODUCT APPROVAL | | | SUBMITTED. | | | | | | 6- OK. | | | 7- OK. | | | 8- OK. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-14 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-13 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2021-10-14 13:53:43 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21080730 | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | | ISSUANCE. | | | | | | NOTE: | | | SEC. 606 FBC-EXISTING BUILDING. SEC. 801.3 FBC-EXISTING | | | BUILDING. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE. | | | | | | 1- DRAWINGS WERE NOT SIGNED AND SEALED BY THE ARCHITECT | | | AND ENGINEER OF RECORD. ALL DRAWINGS NEED TO BE SIGNED | | | AND SEALED AS REQUIRED BY CHAPTER 481 F.S. AND CHAPTER | | | 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC | | | RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH | | | ARCHITECT'S/ENGINEER'S DIGITAL SIGNATURE OR PROVIDE | | | HARD COPY PLANS WITH ARCHITECT'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | 2-LOT DRAINAGE | | | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | | | | 3- SPECIFY ATTIC ACCESS SIZE AND LOCATION. SEC. R807 | | | FBC-RESIDENTIAL. | | | | | | 4- SPECIFY ROOF SHEATHING NAIL TYPE, SIZE AND SPACING | | | AS REQUIRED BY SEC. R803.2 FBC-RESIDENTIAL. | | | NOTE: ROOF SHEATHING ATTACHMENT DETAIL 1/S2 DOESN'T | | | PROVIDE THIS INFORMATION. | | | | | | 5-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)FRENCH DOOR AS SHOWN ON PLANS. | | | NOTE: NOA FRENCH DOOR FL34006.4 UPLOADED TO PROJECTDOX | | | SHOWS WINDOW MULLION PRODUCT APPROVAL NOT FRENCH DOOR. | | | | | | B)HIP & RIDGE METAL SUPPORT TO BE USED. AND, CLEARLY | | | MARK SPECIFIC METAL CHANNEL TO BE INSTALLED. SEE | | | PERFORMANCE LIMITATIONS TABLES ON PRODUCT APPROVAL | | | SUBMITTED. | | | | | | C)ROOF UNDERLAYMENT FL14317-R12 SUBMITTED: CLEARLY MARK | | | WHICH TESTED ASSEMBLY IS GOING TO BE INSTALLED. SEE | | | SEC. 5.8.2 AND SEC. 5.8.3 OF PRODUCT APPROVAL | | | SUBMITTED. | | | THERE ARE 6 ASSEMBLIES. SPECIFY WHICH ASSEMBLY FROM | | | SEC. 5.8.3.1 IS GOING TO BE INSTALLED. | | | | | | 6- ADDITION IS DESIGNED WITH UNVENTED ATTIC. ARCHITECT | | | IS SPECIFYING R-20 ICYNENE SPRAY INSULATION. PROVIDE | | | ICC EVALUATION REPORT FOR THE ICYNENE R-20 INSULATION | | | TO VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. | | | NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN | | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 7- DETAIL 4/A-05 AND DETAIL 5 ON SHEET A-05: REVISE THE | | | SIZE OF THE STRUCTURAL BUCK SPECIFIED. STRUCTURAL BUCK | | | NEEDS TO PROVIDE FULL SUPPORT TO THE DOOR FRAME AND | | | NEED TO EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW | | | OR DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | | FBC-RESIDENTIAL. 2X4 BUCK IS SMALLER THAN THE DOOR | | | FRAME. REVISE AS REQUIRED. | | | | | | 8-PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR NEW | | | AFIREWATER FIREPLACE. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-12 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-12 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-09-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-09-27 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-27 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-09-27 13:38:41 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | 220.16 LOADS FOR ADDITIONS TO EXISTING INSTALLATIONS. | | | | | | (A) DWELLING UNITS. LOADS ADDED TO AN EXISTING DWELLING | | | UNIT(S) SHALL COMPLY WITH THE FOLLOWING AS APPLICABLE: | | | | | | (1) LOADS FOR STRUCTURAL ADDITIONS TO AN EXISTING | | | DWELLING UNIT | | | OR FOR A PREVIOUSLY UNWIRED PORTION OF AN EXISTING | | | DWELLING | | | UNIT, EITHER OF WHICH EXCEEDS 46.5 M2 (500 FT2), SHALL | | | BE CALCULATED IN ACCORDANCE WITH 220.12 AND 220.14. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-02-25 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-02-25 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-02-18 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-02-18 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-12 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-13 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-14 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-08-20 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-02-28 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-02-23 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2022-02-27 07:40:45 | RECEIPT MU-2022-008441 - $22.46 PAID | | 2022-02-23 15:35:34 | 2/23/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-14 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-14 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2021-10-14 14:48:00 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-30 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-30 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-12-17 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-12-17 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-10 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-10 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2021-09-10 10:50:24 | 09/10/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-17 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-17 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2022-02-17 16:33:20 | SEE SUPPORTING DOCUMENTS FOR APPROVED ROOFING PRODUCTS. | | | JG. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-01-11 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-01-11 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2022-01-11 11:14:12 | SECOND ROOFING REVIEW: | | | | | | 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)HIP & RIDGE METAL SUPPORT TO BE USED. AND, CLEARLY | | | MARK SPECIFIC METAL CHANNEL TO BE INSTALLED. SEE | | | PERFORMANCE LIMITATIONS TABLES ON PRODUCT APPROVAL | | | SUBMITTED. | | | | | | RESPONSE: | | | NOT SUBMITTED. | | | | | | B) ROOF UNDERLAYMENT FL14317-R12 SUBMITTED: CLEARLY | | | MARK WHICH TESTED ASSEMBLY IS GOING TO BE INSTALLED. | | | SEC. 5.8.2 AND SEC. 5.8.3 OF PRODUCT APPROVAL | | | SUBMITTED. | | | THERE ARE 6 ASSEMBLIES. SPECIFY WHICH ASSEMBLY FROM | | | SEC. 5.8.3.1 IS GOING TO BE INSTALLED. | | | | | | RESPONSE: | | | STILL NOT CLEAR WHICH ASSEMBLY TO BE USED. TABLE 2 ON | | | PAGE 4 OF 6 OF PRODUCT APPROVAL WAS MARKED, BUT IT | | | DOESN'T CLARIFY IF USING ASTM D226 TYPE II FELT OR | | | CITADEL PLUS AS THE SUBSTRATE. I F USING ASTM D226 FELT | | | , THEN PROVIDE FRSA/TRI PRESCRIPTIVE METHOD USED. IF | | | USING CITADEL PLUS , THEN CIRCLE WHICH ASSEMBLY IS | | | GOING TO BE USED. SEE SEC. 5.8.2 OF PRODUCT APPROVAL | | | SUBMITTED. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-14 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-14 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2021-10-14 14:51:36 | ROOFING REVIEW: | | | | | | 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)HIP & RIDGE METAL SUPPORT TO BE USED. AND, CLEARLY | | | MARK SPECIFIC METAL CHANNEL TO BE INSTALLED. SEE | | | PERFORMANCE LIMITATIONS TABLES ON PRODUCT APPROVAL | | | SUBMITTED. | | | | | | B) ROOF UNDERLAYMENT FL14317-R12 SUBMITTED: CLEARLY | | | MARK WHICH TESTED ASSEMBLY IS GOING TO BE INSTALLED. | | | SEC. 5.8.2 AND SEC. 5.8.3 OF PRODUCT APPROVAL | | | SUBMITTED. | | | THERE ARE 6 ASSEMBLIES. SPECIFY WHICH ASSEMBLY FROM | | | SEC. 5.8.3.1 IS GOING TO BE INSTALLED. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-23 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-23 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-17 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-17 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2022-02-17 16:56:12 | SIGNATURE REVIEW: | | | | | | 1- DRAWING C-01 STILL NOT SIGNED AND SEALED. | | | CHAPTER 481 F.S. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-01-11 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-01-11 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2022-01-11 11:16:45 | SIGNATURE REVIEW: | | | | | | 1- DRAWINGS WERE NOT SIGNED AND SEALED BY THE ARCHITECT | | | AND ENGINEER OF RECORD. ALL DRAWINGS NEED TO BE SIGNED | | | AND SEALED AS REQUIRED BY CHAPTER 481 F.S. AND CHAPTER | | | 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC | | | RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH | | | ARCHITECT'S/ENGINEER'S DIGITAL SIGNATURE OR PROVIDE | | | HARD COPY PLANS WITH ARCHITECT'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | RESPONSE: | | | THE FOLLOWING DRAWINGS WERE NOT SIGNED & SEALED: C-01, | | | SP-01, A-00, A-02, A-03, A-04, S1, S3, S4, S5. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-10-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-10-14 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-10-14 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2021-10-14 14:52:32 | SIGNATURE REVIEW: | | | | | | 1- DRAWINGS WERE NOT SIGNED AND SEALED BY THE ARCHITECT | | | AND ENGINEER OF RECORD. ALL DRAWINGS NEED TO BE SIGNED | | | AND SEALED AS REQUIRED BY CHAPTER 481 F.S. AND CHAPTER | | | 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC | | | RECORDS. | | | SUBMIT DRAWINGS ELECTRONICALLY WITH | | | ARCHITECT'S/ENGINEER'S DIGITAL SIGNATURE OR PROVIDE | | | HARD COPY PLANS WITH ARCHITECT'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-02-25 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-02-25 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-02-18 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-02-18 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2022-02-18 10:00:16 | 2/18/2022 FAILED- | | | | | | PLEASE APPLY FOR LANDSCAPE PERMIT THAT OBTAINS A PERMIT | | | NUMBER. PLEASE APPLY FOR A TREE ALTERATION PERMIT | | | | | | PERMITS MUST BE APPLIED FOR TO ALLOW STAFF TO MOVE | | | FOWARD. | | | | | | IF YOU HAVE ANY QUESTIONS REGARDING LANDSCAPE PLEASE | | | CONTACT RAY CARANCI AT [email protected] | | | | | | VALENTINA BROGLIA | | | ASSOICATA PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-01-03 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-01-03 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2022-01-03 13:38:47 | 1/3/22- FAILED. SINCE VALUE OF THE PERMIT EXCEED 50% OF | | | THE VALUE OF THE EXISTING HOME (PBCPA), THAN THE SITE | | | MUST MEET THE APPROVED LANDSCAPE PLAN (18050615). IN | | | ADDITION, IT APPEARS THAT LANDSAPING WILL BE REMOVED TO | | | CONSTRUCT THE ADDITION. IF THIS IS THE CASE THAN A TREE | | | ALTERATION PERMIT IS REQUIRED. | | | | | | ANGELLA VANN | | | 561-822-1441 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-03 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-09-03 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2021-09-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-09-03 16:29:08 | ******************ZONING | | | REVIEW************************* | | | | | | PROJECT VALUE TRIGGERS THE LANDSCAPE CODE. | | | | | | SHOW THE FOLLOWING ON A SEPARATE LANDSCAPE PLAN. | | | | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|