| Plan Review Stops For Permit 21080720 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-21 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-19 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-13 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-13 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2021-10-13 16:18:05 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 2ND REVIEW COMMENTS | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1. FBC R 301, IT APPEARS THE PROPOSED IMPROVEMENT IS | | | OUTDOORS. HOW WILL THIS RESIST WIND LOADS? | | | | | | "FOUNDATION NOTES" STATE THIS IS EXPOSURE B, HAVE | | | ENGINEER EXPLAIN RATIONALE FOR EXPOSURE B. | | | | | | 2. FBC R 301, PLAN INCLUDES WIND DESIGN CRITERIA BUT | | | LACKS STRUCTURAL DETAILS TO SHOW HOW THIS WILL RESIST | | | WIND LOADS. | | | | | | 3. SHEET 2 OF 3 MAKES REFERENCE TO A "GRILL CENTER", | | | PROVIDE STRUCTURAL DETAILS. SPECS FOR THE GRILL AND | | | PIZZA OVEN WERE PROVIDED BUT SHOW THEM INSTALLED INTO A | | | FREESTANDING STRUCTURE, NO DETAILS PROVIDED FOR THE | | | CABINETRY, NOT CLEAR HOW THE CABINETRY WILL RESIST WIND | | | LOADS AS IT APPEARS THAT THE PROPOSED INSTALLATION IS | | | NOT WITHIN THE BUILDING FOOTPRINT. | | | | | | 4. SHEET 1 STILL HAS STEPHEN GAYDOSH'S TITLE BLOCK, SEE | | | PREVIOUS LIST, HIS LICENSED IS REVOKED. FS471. | | | (CORRECTED) | | | | | | NEW COMMENTS: | | | | | | 5. THIS SITE APPEARS TO BE LOCATED IN EXPOSURE "C" PER | | | FBC R301.2.1.4.2. DESIGNER SHALL PROVIDE RATIONAL | | | ANALYSIS FOR USING EXPOSURE "B" FOR THE STRUCTURAL | | | DESIGN. | | | | | | 6. PROVIDE STRUCTURAL DETAILS. INCLUDE FOUNDATION TO | | | WALL CONNECTION AND WALL VERTICAL RE-INFORCING. SPECIFY | | | GROUT TO BE USED IN WALL CELLS. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-09-24 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-09-24 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2021-09-24 16:01:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1. FBC R 301, IT APPEARS THE PROPOSED IMPROVEMENT IS | | | OUTDOORS. HOW WILL THIS RESIST WIND LOADS? | | | | | | "FOUNDATION NOTES" STATE THIS IS EXPOSURE B, HAVE | | | ENGINEER EXPLAIN RATIONALE FOR EXPOSURE B. | | | | | | 2. FBC R 301, PLAN INCLUDES WIND DESIGN CRITERIA BUT | | | LACKS STRUCTURAL DETAILS TO SHOW HOW THIS WILL RESIST | | | WIND LOADS. | | | | | | 3. SHEET 2 OF 3 REFERS MAKES REFERENCE TO A "GRILL | | | CENTER", PROVIDE STRUCTURAL DETAILS. SPECS FOR THE | | | GRILL AND PIZZA OVEN WERE PROVIDED BUT SHOW THEM | | | INSTALLED INTO A FREESTANDING STRUCTURE, NO DETAILS | | | PROVIDED FOR THE CABINETRY, NOT CLEAR HOW THE CABINETRY | | | WILL RESIST WIND LOADS AS IT APPEARS THAT THE PROPOSED | | | INSTALLATION IS NOT WITHIN THE BUILDING FOOTPRINT. | | | | | | 4. SHEET 1 STILL HAS STEPHEN GAYDOSH'S TITLE BLOCK, SEE | | | PREVIOUS LIST, HIS LICENSED IS REVOKED. FS471. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-21 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-21 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2021-08-21 12:45:37 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, IT APPEARS THE PROPOSED IMPROVEMENT IS | | | OUTDOORS. HOW WILL THIS RESIST WIND LOADS? | | | | | | 2. FS471, THE TITLE BLOCK OF SAGE ENGINEERING IS ON THE | | | PLANS (GAS PLAN, LAYOUT PHOTO PAGES, CHECK ALL). MR. | | | GAYDOSH'S LICENSE WAS REVOKED IN 2019 PER DBPR WEBSITE. | | | THE TITLE "ENGINEER" CAN ONLY BE USED BY INDIVIDUALS | | | LICENSED BY FBPE. SINCE HE IS NOT SIGNING AND SEALING | | | THIS PLAN, IT IS NOT CLEAR WHY HIS TITLE BLOCK WOULD BE | | | ON THE PLAN. REMOVE OR PROVIDE CLARIFICATION. | | | | | | 3. PAGE 2 OF 4 (SLAB CERTIFICATION) LACKS A TITLE BLOCK | | | AS REQUIRED BY FS481. CHECK ALL PAGES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-21 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-21 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-09-13 |
Time |
21:48 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-09-13 |
Time |
20:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-28 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-28 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2021-09-28 13:53:28 | GAS CONNECTION FROM AN EXISTING SOURCE, NEW GRILL MAY | | | REQUIRE A HOOD AND GAS AFFIDAVIT, INSPECTOR TO VERIFY | | | COMPLIANCE IN THE FIELD. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-08-28 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-08-28 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-08-28 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2021-08-28 10:48:52 | 1ST REVIEW FBC-2020 GAS | | | PERMIT-21080720 | | | 8/28/2021 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH | | | EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. AT | | | THIS TIME. WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6695 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-15 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-15 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-13 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-08 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-28 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-28 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-09-13 |
Time |
21:48 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-08-18 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-28 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-09-28 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-08-28 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-08-28 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-08-28 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-15 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-15 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2021-10-15 09:52:44 | SIGNATURE PASSED REVEIW WITH SEAL AND WET SIGNATURE ON | | | 3 DRAWINGS. WALL DETAIL,FOUNDATION NOTES AND WIND | | | DESIGN DATA |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-10-12 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-10-08 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2021-10-12 14:31:52 | ENGINEERING PREPARED BY MICHAEL BABER OF, PROPOSED | | | OUTDOOR BBQ GRILL LABELED 2A OF 3, ROUTED TO STORAGE. | | | ALL OTHER DRAWINGS PASSED SIGNATURE BY PREVIOUS | | | SIGNATURE VERIFICATION PERSONNEL. M.P. 10/12/2021 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-09-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-09-17 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-09-17 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2021-09-17 16:27:29 | | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | SIGNATURE REVIEW APPROVED BY PAPER SIGNED/SEALED | | | SUBMITTALS. THE PAPER SUBMITTALS HAVE BEEN ROUTED TO | | | STORAGE. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-19 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-19 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2021-08-19 07:50:02 | SIGNATURES ARE COPIES, NEED ORIGINAL SIGNATURES FOR | | | APPROVAL. JLEAHY | | | | | | PLANS SENT TO LIBRAIAN OFFICE DENIED BOX. JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-09-07 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-09-07 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-09-07 |
Time |
|
Sent To |
I |
|
| Notes |
|
|