| Plan Review Stops For Permit 21080700 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
5 |
Status |
P |
Date |
2023-02-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-02-17 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-02-17 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-22 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-22 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2022-11-22 11:36:25 | 4TH ASBESTOS REVIEW- PLEASE COMPLY. | | | | | | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRCTOR?S LETTERHEAD, STATING THAT | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-18 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-18 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2022-10-18 08:10:53 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRCTOR?S LETTERHEAD, STATING THAT | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-05-24 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-05-24 08:17:19 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRCTOR?S LETTERHEAD, STATING THAT | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-09-08 |
Time |
07:51 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-09-08 07:52:36 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected] THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-05-24 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-09-08 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-09-08 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2021-09-08 08:30:39 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21080700 | | | ADD: 6108 S. DIXIE HWY. # 1 | | | CONT: NEITA & ASSOCIATES | | | TEL: 561-602-0009 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. SEPT. 08/2021 | | | ACTION: DENIED | | | | | | 1) THE PERMIT VALUE OF $5,000.00 DOLLARS IS LOW FOR THE | | | DESCRIPTION OF WORK. 109.3 BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | 2) SHEET A101 THE FLOOR PLAN SHOWS NEW LOW WALLS AT THE | | | TAKEOUT AREA. THERE ARE LOW WALLS AT 34 INCHES AND A | | | 42-INCH-HIGH WALL IT APPEARS AT THE POINT OF SALES. | | | 2020 FBC-ACCESSIBILITY CODE SHOW COMPLIANCE WITH THE | | | ACCESS. CODE 305.5 POSITION. UNLESS OTHERWISE | | | SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE | | | POSITIONED FOR EITHER A FORWARD OR PARALLEL APPROACH TO | | | AN ELEMENT. | | | 904.4 SALES AND SERVICE COUNTERS. SALES COUNTERS AND | | | SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2. | | | THE ACCESSIBLE PORTION OF THE COUNTERTOP SHALL EXTEND | | | THE SAME DEPTH AS THE SALES OR SERVICE COUNTERTOP. | | | | | | 3) SHEET A101 THE FLOOR PLAN SHOWS NEW WALL IN CORRIDOR | | | 4 FEET WIDE. THERE IS NO ROOM FOR TURNING SPACES SEE | | | 2020 FBC-ACCESSIBILITY CODE 304.3. | | | | | | 4) SHEET A101 THE FLOOR PLAN SHOWS AN EXISTING DOOR D-2 | | | TO THE RESTROOM ONLY 2 FEET WIDE. FLORIDA ACCESSIBILITY | | | CODE SECTION: DISPROPORTIONATE COST 202.4.1. PLEASE | | | REVIEW HOW YOU ARE TO MEET DISPROPORTIONATE COST. | | | EITHER THE CONTRACTOR OR THE DESIGNER OF RECORD ON | | | THEIR LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO | | | SPEND UP TO THE 20% ($1,000.00 DOLLARS) | | | DISPROPORTIONATE FUNDS LISTED FOR EACH ELEMENT WHERE | | | THE FUNDS ARE BEING SPENT AND IN THE ORDER LISTED IN | | | SECTION 202.4.1 DISPROPORTIONATE COST OF THE 2020 | | | ACCESSIBILITY CODE. THE INSTALLATION OF A NEW DOOR TO | | | THE RESTROOM CAN BE ACCOMPLISHED FOR LESS THAN | | | $1,000.00. FLORIDA ACCESSIBILITY CODE SECTION: | | | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU | | | ARE TO MEET DISPROPORTIONATE COST. EITHER THE | | | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR | | | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP | | | TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH | | | ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE | | | ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST | | | OF THE 2020 ACCESSIBILITY CODE. | | | | | | 5) THE FLOOR PLAN DOES NOT INDICATE IF AT THE FRONT | | | ENTRY DOOR FLOOR IS THE SAME LEVEL AS THE EXTERIOR SLAB | | | OR A DIFFERENCE IN ELEVATIONS. 202 FBC-ACCESS. CODE | | | CHANGES IN LEVEL 303.2 AND 303.3. WHERE CHANGES IN | | | LEVEL ARE PERMITTED IN THE FLOOR OR GROUND SURFACES, | | | THEY SHALL COMPLY WITH SECTION 303. SEE 303.1 & 303.2. | | | | | | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE | | | WORKING FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-09-13 |
Time |
22:51 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-09-13 |
Time |
21:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-05-23 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-08-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-08-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-08-17 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2021-08-17 11:10:45 | FIRE PROVISO: | | | | | | THE HOOD & SUPPRESSION SYSTEMS SHALL BE INSTALLED | | | UNDER SEPARATE PERMITS & SHOP DRAWINGS | | | | | | THE LOCK SETS FOR DE - 1 & 2 SHALL COMPLY WITH NFPA | | | 101, CH 7 MEANS OF EGRESS. | | | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, | | | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE | | | EGRESS SIDE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-25 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-25 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2022-05-25 15:36:47 | PER THE ARCHTITECT'S NOTE ON SHEET P101 THE GAS PLANS | | | FOR THE RESTAURANT SHALL BE UNDER A SEPARATE PERMIT | | | SUBMITTAL. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-09 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-09 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2021-09-09 10:24:03 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21080700 | | | 9/9/21 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SECTIONS 107.2.1 & 107.3.5.1.5 WPB & FBC FG: PROVIDE | | | GAS PLANS AND SPECIFICATIONS INCLUDING: | | | A) GAS PIPING LAYOUT PLANS AND RISER DRAWING. | | | B) GAS APPLIANCE AND EQUIPMENT SCHEDULES. | | | C) COMBUSTION AIR PLANS AND CALCULATIONS. | | | D) VENTING PLANS, DIAGRAMS, AND SPECIFICATIONS. | | | E) APPLIANCE AND EQUIPMENT SUBMITTALS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-17 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-17 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-11-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-11-18 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-19 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-06 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-25 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-21 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-09-13 |
Time |
22:51 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-08-16 |
Time |
06:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-17 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-17 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-17 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-17 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-25 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-25 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2022-05-25 17:18:21 | THE ENERGY CALCULATIONS SUBMITTED SHOW AHU-1 AND AHU-2; | | | THE MECHANICAL EQUIPMEN SIZING CALCULATIONS SHOW ONLY | | | AHU-1 PLEASE CORRECT THIS AS BOTH CALCULATIONS SHOULD | | | BE CONSISTENT AS TO THE NUMBER OF UNITS AND THE AREAS | | | THEY SERVE. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-25 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-25 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2021-08-25 15:46:58 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21080700 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE ADD TENANT SPACE TO PERMIT APPLICATION AND ON | | | THE DRAWINGS. FBC 107.2.1 | | | | | | 2) PLEASE ADD A NOTE ON THE DRAWING STATING THAT THE | | | HOODS WILL REQUIRE A SEPARATE PERMIT APPLICATION, | | | DRAWINGS AND REVIEW. THE HOOD WILL NOT BE REVIEWED | | | UNDER THIS PERMIT. | | | | | | 3) THIS IS A CHANGE OF USE FOR THIS TENANT SPACE. | | | PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH | | | USE OF SPACE IN THIS TENANT SPACE. FBC M 403.3.1.1 AND | | | TABLE 403.3.1.1 | | | | | | 4) PROVIDE A MECHANICAL DRAWING SHOWING THE MECHANICAL | | | SYSTEM LAYOUT FOR THIS NEW RESTAURANT. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-27 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-27 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-22 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-22 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2022-11-22 11:21:48 | 4TH REVIEW FBC-2020 PLUMBING | | | PERMIT- 21080700 | | | 11/22/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P101: AS PREVIOUSLY NOTED, THE GREASE | | | INTERCEPTOR PERMIT IS REQUIRED TO BE SUBMITTED PRIOR TO | | | ISSUANCE OF THE PRIMARY PERMIT. YOU CAN SUBMIT AN | | | APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT HAVE | | | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected]. YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER | | | YOU HAVE THE PERMIT GENERATED, NOTIFY ME VIA EMAIL AND | | | I WILL CHANGE THE REVIEW STATUS TO PASS. | | | | | | 2) P101: PER MANUFACTURER'S SPECIFICATIONS THE ASSE | | | 1070 LEONARD MIXING IS NOT DESIGNED TO BE A MASTER | | | THERMOSTATIC MIXING VALVE BUT RATHER FOR USE AS THE | | | FINAL TEMPERATURE REGULATION DEVICE AT SINGLE OR A BANK | | | OF FIXTURES REQUIRING TEMPERED WATER DELIVERY SUCH AS | | | THE LAVATORY IN THE BATHROOM OR THE HANDWASH SINK. AN | | | ASSE 1017 APPROVED MIXING VALVE SHALL BE INSTALLED AT | | | THE WATER HEATER- SECS. 607.1.1 & 607.2.1 FBC P. PLEASE | | | CORRECT THE PLAN. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-07 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-07 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2022-10-07 11:55:18 | 2ND PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC 1003.3.8 - THE GREASE INTERCEPTOR MUST | | | CONNECT DIRECTLY TO THE SANITARY. | | | | | | 2. 2020 FPC - 607.1.1 - ALL HOT WATER MUST GO THROUGH A | | | MIXING DEVICE. THE THERMOSTAT FOR THE WATER HEATER | | | SHALL NEVER SERVE AS THE TEMPERATURE LIMITING MEANS FOR | | | THE PURPOSES OF COMPLYING WITH THE REQUIREMENTS FOR | | | ALLOWABLE HOT OR TEMPERED WATER. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-25 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-25 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2022-05-25 15:33:14 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21080700 | | | 5/25/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P101: SHEET A000 CLASSIFIES THE SPACE AS A B | | | OCCUPANCY HOWEVER THE FIXTURE CALCULATIONS ARE | | | INDICATING AN M OCCUPANCY. PLEASE CHOOSE ONE OR THE | | | OTHER- SEC. 107.2.1 WPB. | | | | | | 2) P101: THE MOP SINK DRAINAGE SHALL BE DISCHARGED INTO | | | THE GREASE INTERCEPTOR- SEC. 1003.3.1 FBC P. | | | | | | 3) P101: EACH WELL OF THE 3-COMPARTMENT SINK SHALL | | | DISCHARGE INDIRECTLY INTO A WASTE RECEPTOR- SEC. | | | 802.1.1 FBC P. | | | | | | 4) P101: TEMPERED WATER SHALL BE DELIVERED FROM | | | LAVATORIES HAVING BOTH HOT AND COLD WATER SUPPLIED TO | | | THE FIXTURE- SEC. 419.5 FBC P. PLEASE PROVIDE AN ASSE | | | 1070 MIXING VALVE FOR THE SUPPLY PIPING- SEC. 607.1.2. | | | | | | 5) P101: A MEANS OF LIMITING THE HOT WATER DELIVERY | | | TEMPERATURE TO THE MOP SINK AND HAND SINK SHALL BE | | | PROVIDED AND CANNOT BE THE THERMOSTAT ON THE WATER | | | HEATER- SEC. 607.1.1 FBC P. PROVIDE EITHER A MASTER | | | THERMOSTATIC MIXING VALVE AT THE WATER HEATER OR A | | | POINT OF USE MIXING VALVE AT THE FIXTURES. | | | | | | 6) P101: THE 1/2-INCH HW LAVATORY FIXTURE SUPPLY PIPE | | | IS EXCEEDING THE MAXIMUM 2 FT. ALLOWABLE LENGTH FROM | | | THE SOURCE OF THE HW- SEC AND TABLE C404.1 FBC EC. | | | PROVIDE EITHER A RECIRCULATION PUMP FOR THE SYSTEM OR A | | | POINT OF USE WATER HEATER AT THE LAVATORY. | | | | | | 7) P101: DUE TO A CHANGE IN PROCESS, THE GREASE | | | INTERCEPTOR PERMIT IS REQUIRED TO BE SUBMITTED PRIOR TO | | | ISSUANCE OF THE PRIMARY PERMIT. YOU CAN SUBMIT AN | | | APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT HAVE | | | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT | | | APPLICATION TO [email protected] . YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER | | | YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL | | | AND I WILL CHANGE THE REVIEW STATUS TO PASS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-09 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-09 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2021-09-09 10:18:24 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21080700 | | | 9/8/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SECTIONS 107.21 & 107.3.5.1.3 WPB & FBC P: PROVIDE | | | PLUMBING PLANS AND SPECIFICATIONS INCLUDING- | | | | | | A) PLUMBING FIXTURE CALCULATIONS FOR THE CHANGE OF USE- | | | TABLE 403.1 FBC P. | | | B) PLUMBING PIPING PLANS AND ISOMETRIC DRAWINGS. | | | C) PLUMBING EQUIPMENT SCHEDULE. | | | D) FOOD EQUIPMENT PLAN AND SCHEDULE | | | E) GREASE WASTE DISPOSAL AND INTERCEPTOR PLANS AND | | | SPECIFICATIONS. PLEASE NOTE A SEPARATE PERMIT IS | | | REQUIRED FOR NEW GREASE INTERCEPTOR INSTALLATIONS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-17 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-17 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-22 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-22 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-07 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-07 11:58:41 | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | | 61G1-16 AND 61G15, F.A.C | | | | | | PAGE E101 IS NOT DIGITALLY SIGNED AND SEALED. | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-25 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-25 |
Time |
17:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-08-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-17 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-17 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2021-08-17 07:30:03 | SIGNATURE PLANS SENT TO STORAGE JLEAHY |
|
|