Plan Review Details - Permit 21080615
Plan Review Stops For Permit 21080615
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-10-15 Cont ID  
Sent By pvalenti Date 2021-10-15 Time 17:38 Rev Time 0.00
Received By pvalenti Date 2021-10-15 Time 17:33 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-09-15 Cont ID  
Sent By jwitmer Date 2021-09-15 Time 15:01 Rev Time 0.00
Received By jwitmer Date 2021-08-16 Time 11:24 Sent To  
Notes
2021-09-15 15:01:43COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-10-26 Cont ID  
Sent By jwitmer Date 2021-10-26 Time 14:14 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2021-10-26 14:14:01WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21080615
 ADD: 1855 PALM BEACH LAKES BLVD. SUITE: B05
 CONT: J. RAYMOND CONSTRUCTION CORP.
 TEL: 407-862-6966
 JOBSITE: 407-595-6413 ANTHONY MASADO
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: TUES. OCT. 26TH/ 2021
 ACTION: BUILDING PROVISOS
  
 1) WELDED OR BOLTED CONNECTIONS. THIS BUILDING CONTAINS
 EITHER BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR
 IS REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
  
 2) 2020 FBC-BUILDING CODE 107.2. AT TIME OF FRAMING
 INSPECTION PROVIDE THE MANUFACTURER?S ROOF TOP
 EQUIPMENT TO CURBS AND CURBS TO ROOF FRAMING CONNECTION
 PER ENGINEER SIGNED/ SEALED DETAILS. THESE DETAILS MUST
 BE IN ACCORDANCE WITH THE WIND LOAD DESIGN SHOWN ON
 SHEET S001.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-10-18 Cont ID  
Sent By pvalenti Date 2021-10-18 Time 14:07 Rev Time 0.00
Received By pvalenti Date 2021-10-15 Time 17:33 Sent To  
Notes
2021-10-18 14:45:28PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 9.) FBC B 904.1 - FBC A 904.4.2, PROVIDE ON PLANS THE
 REQUIRED ACCESSIBLE DETAILS FOR CHECK OUT COUNTERS PER
 THE FBC ACCESSIBILITY CODE. THE CONTRACTOR WILL BE
 REQUIRED TO COMPLY WITH THOSE REQUIREMENTS.
  
  
 PROVISOS:
  
 2.) FBC M 306.5, THE ROOF DECK MUST NOT REQUIRE
 CLIMBING OVER OBSTRUCTIONS GREATER THAN 30" IN HEIGHT
 AND PORTABLE LADDERS SHALL NOT BE REQUIRED BETWEEN THE
 ROOF ACCESS HATCH AND AND ROOF/ROOF TOP UNITS.
  
 5B.) AWS D1.1 CLAUSE 5.2 & 6.7: AT TIME OF INSPECTION
 PLEASE PROVIDE A WELD PROCEDURE SPECIFICATION; THE
 W.P.S. SPECIFIES THE REQUIRED ESSENTIAL VARIABLES
 INCLUDING: BASE MATERIALS, JOINTS, PROCESS, AND FILLER
 METALS TO BE USED.
 AWS D1.1 CLAUSE 6.16: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
 NOTE: A THIRD PARTY WILL BE REQUIRED TO CERTIFY
 WELD/BOLT CONNECTIONS.
  
 6.) FBC B 107.2, AT TIME OF INSPECTION PROVIDE
 MANUFACTURER'S ROOF TOP EQUIPMENT TO CURBS AND CURBS TO
 ROOF FRAMING CONNECTION (ENGINEER SIGNED/SEALED)
 DETAILS. THESE DETAILS MUST BE IN ACCORDANCE WITH THE
 WIND LOAD REQUIREMENTS SHOWN ON SHEET S 001.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-09-15 Cont ID  
Sent By jwitmer Date 2021-09-15 Time 16:06 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2021-09-15 16:05:56WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21080615
 ADD: 1855 PALM BEACH LAKES BLVD. SUITE: B05
 CONT: J. RAYMOND CONSTRUCTION CORP.
 TEL: 407-862-6966
 JOBSITE: 407-595-6413 ANTHONY MASADO
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 15TH/2021
 ACTION: DENIED
 1) SHEET C2.1 ELEVATIONS PLEASE NOTE THE NOTATION
 MARKERS FOR THE ELEVATIONS IDENTIFYING THE WALL TYPE
 FINISHES ARE TOTALLY BLACK NOT LEGIBLE. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2) THE FRONT AND REAR ELEVATIONS ARE SHOWN WITH THE
 FINISH ROOF ELEVATION OVER 20 FEET IN HEIGHT. THE ROOF
 PLAN IS ALSO ON THE SAME SHEET BUT THERE IS NO ACCESS
 TO THE ROOF TOP RTU UNITS. NO SHIPS LADDER OR ROOF
 HATCH IS SHOWN.
 2020 FBC-M 306.5 EQUIPMENT AND APPLIANCES ON ROOFS OR
 ELEVATED STRUCTURES. WHERE EQUIPMENT REQUIRING ACCESS
 OR APPLIANCES ARE LOCATED ON AN ELEVATED STRUCTURE OR
 THE ROOF OF A BUILDING SUCH THAT PERSONNEL WILL HAVE TO
 CLIMB HIGHER THAN 16 FEET (4877 MM) ABOVE GRADE TO
 ACCESS SUCH EQUIPMENT OR APPLIANCES, AN INTERIOR OR
 EXTERIOR MEANS OF ACCESS SHALL BE PROVIDED. SUCH ACCESS
 SHALL NOT REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER
 THAN 30 INCHES (762 MM) IN HEIGHT OR WALKING ON ROOFS
 HAVING A SLOPE GREATER THAN 4 UNITS VERTICAL IN 12
 UNITS HORIZONTAL (33-PERCENT SLOPE). SUCH ACCESS SHALL
 NOT REQUIRE THE USE OF PORTABLE LADDERS. WHERE ACCESS
 INVOLVES CLIMBING OVER PARAPET WALLS, THE HEIGHT SHALL
 BE MEASURED TO THE TOP OF THE PARAPET WALL.
  
 3) BUILDING PROVISO/ DEFERRED SUBMITTALS. SHEET C1
 INDICATES THE PRODUCT APPROVALS FOR COMPONENTS AND
 CLADDING ARE TO BE DEFERRED SUBMITTALS. DOCUMENTS FOR
 DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING
 OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE
 IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING.
 THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED
 UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN
 APPROVED BY THE BUILDING OFFICIAL.
  
 4) NOTE ONLY NO ACTION NEEDED. SHEET S200 COMPONENTS &
 CLADDING PRESSURES SERVICE LOADS (VASD) ARE GOOD.
  
 5A) SHEET S100 SHOWS A NEW VESTIBULE AT THE FRONT
 ENTRY, BUT THE STRUCTURAL PLANS DO NOT GIVE THE
 DIMENSIONS OF THE VESTIBULE IN WIDTH, LENGTH NOR THE
 BOTTOM OF THE STEEL FRAMING. SHEET C2 DID NOT HAVE
 DIMENSIONS FOR THIS AREA. THE STRUCTURAL PLAN DOES NOT
 INDICATE THE SIZE OR TYPE OF WELDS FOR THE STRUCTURAL
 MEMBERS. THE PLAN IS DEFICIENT AS IF THERE WILL BE
 REQUIRED NEW FOUNDATION WORK IN THIS AREA AND HOW THE
 STEEL COLUMNS ARE TO BE ANCHORED TO THE FOUNDATION. THE
 STEEL FRAMEWORK NO SHOP DRAWINGS WERE SUBMITTED, NOR
 REVIEWED BY THE DESIGNER OF RECORD. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 5B) WELDED OR BOLTED CONNECTIONS. THIS BUILDING
 CONTAINS EITHER BOLTED AND OR WELDED CONNECTIONS. THE
 CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON
 THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL
 BE REQUIRED. THE OWNER MAY JUST HIRE A 3RD PARTY
 ENGINEERING FIRM TO COMPLETE AND APPROVE THE FORMER
 INSPECTIONS. REPORTS SUBMITTED TO BUILDING INSPECTOR AT
 TIME OF FRAMING INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
  
 6A) THE S-110 ROOF PLAN SHOWS 9 ROOF TOP RTU UNITS BUT
 THERE IS NO INFORMATION AS IF ANY UNITS ARE BEING
 REPLACED. SHEET M001 HAS A GENERIC DETAIL FOR A ROOF
 TOP FAN MOUNTING TO THE ROOF DECK DOES NOT INDICATE HOW
 STEEL ANGLES ARE TO BE ATTACHED TO THE BAR JOIST
 SYSTEM, REFERS TO S-001 FOR TIE DOWN, S001 GIVE THE
 WIND DESIGN ONLY.
  
 6B) M001 HAS A GENERIC DETAIL FOR A ROOF TOP RTU?S
 (DETAIL 7 &8) THERE IS NO INFORMATION FOR ROOF TOP
 CURBS OR THE TIE DOWN OF THE RTU UNIT. 2020 FBC-M-
 301.15 WIND RESISTANCE.
 MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE
 EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO
 RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH
 THE FLORIDA BUILDING CODE, BUILDING.
 FBC-B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND
 PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT IS TO
 BE DESIGNED FOR WIND PRESSURES COMPONENTS AND
 ATTACHMENTS.
 LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP
 EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS,
 DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL
 AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE.
 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL
 MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY
 METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT
 EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY
 AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES.
 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS.
  
 7) THE PLANS DO NOT PROVIDE ANY ELEVATIONS OF THE
 RESTROOMS AND COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY CODE CHAPTER 6.
  
 8) THE PLANS DO NOT PROVIDE ANY DETAILS FOR THE
 ACCESSIBLE DRESSING ROOMS AND COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY SECTIONS 803.1-803.5.
  
 9) THE PLANS DO NOT PROVIDE ANY DETAILS FOR THE CHECK
 OUT COUNTERS AND THE 2020 FBC-ACCESSIBILITY CODE
 904.1-904.4.2.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-09-30 Cont ID  
Sent By jleahy Date 2021-09-30 Time 09:05 Rev Time 0.00
Received By jleahy Date 2021-09-30 Time 08:32 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-04-12 Cont ID  
Sent By jleahy Date 2022-04-12 Time 14:20 Rev Time 0.00
Received By jleahy Date 2022-04-12 Time 14:20 Sent To  
Notes
2022-04-12 14:22:44ANTI THEFT SYSTEM FRONT DOOR. JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-09-08 Cont ID  
Sent By   Date 2021-09-08 Time   Rev Time 0.00
Received By bdolan Date 2021-08-16 Time 11:25 Sent To  
Notes
2021-09-08 11:15:36ALL WORK ON THE FIRE SPRINKLER SYSTEM IS REQUIRED TO BE
 COMPLETED BY A CERTIFIED FIRE SPRINKLER CONTRACTOR AND
 SHALL COMPLY WITH NFPA 13. SEPARATE SHOP DRAWINGS, ARE
 REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY THE
 FIRE PREVENTION BUREAU PRIOR TO ANY WORK ON THE SYSTEM.
  
 THE LIFE SAFETY SYSTEMS, SPRINKLER AND/OR FIRE ALARM,
 SHALL REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-26 Cont ID  
Sent By lmarchan Date 2021-10-26 Time 15:43 Rev Time 0.00
Received By lmarchan Date 2021-10-20 Time 09:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-18 Cont ID  
Sent By pvalenti Date 2021-10-18 Time 14:45 Rev Time 0.00
Received By pvalenti Date 2021-10-08 Time 09:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-09-30 Cont ID  
Sent By jleahy Date 2021-09-30 Time 09:05 Rev Time 0.00
Received By jleahy Date 2021-08-12 Time 13:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-10-13 Cont ID  
Sent By medwards Date 2021-10-13 Time 14:58 Rev Time 0.00
Received By medwards Date 2021-10-13 Time 14:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-08-31 Cont ID  
Sent By medwards Date 2021-08-31 Time 07:07 Rev Time 0.00
Received By medwards Date 2021-08-31 Time 07:07 Sent To  
Notes
2021-08-31 07:08:47PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH
 USE OF SPACE BASED ON FBC M 403.3.1.1 AND TABLE
 403.3.1.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-10-18 Cont ID  
Sent By lcrespo Date 2021-10-18 Time 08:27 Rev Time 0.00
Received By lcrespo Date 2021-10-18 Time 07:29 Sent To  
Notes
2021-10-18 08:27:3910/18/21 REVIEWED FOR CODE COMPLIANCE
 (PLUMBING/BACKFLOW)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-09-24 Cont ID  
Sent By lcrespo Date 2021-09-24 Time 12:25 Rev Time 0.00
Received By lcrespo Date 2021-09-21 Time 13:23 Sent To  
Notes
2021-09-24 12:26:0309/24/21 1ST POOL REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET C1, ON #1, THERE IS A DETAIL FOR TOILET AND
 ACCESSORY DETAIL BUT NO DETAIL THAT PROVIDES THE 2020
 FBC ACCESSIBILITY CODE. WOULD YOU PLEASE PROVIDE A PAGE
 AND SHOW THE FLOWING PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS;
  
 A. PLEASE SHOW CLEAR FLOOR SPACE AND GIVE DIMENSIONS
 FOR FIXTURE CLEARANCES PER FLORIDA BUILDING CODE FOR
 THE FLORIDA ACCESSIBILITY CODE, ONE OF THE ELECTRIC
 WATER COOLERS, EYEWASH, SINK IN THE LOUNGE, WATER
 CLOSET AND LAV IN THE STALLS, ONE LAV OUTSIDE THE
 STALL, AND URINAL PER THE WPB AMENDMENTS TO THE FBC
 SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 B. THE TOILET SEATS NEED TO BE 17 INCHES TO 19 INCHES
 MAXIMUM MEASURED TO THE TOP OF THE SEAT PER THE 2020
 FBC ACC SEC. 604.4 SEATS.
  
 C. WOULD YOU PLEASE SHOW THE HARDWARE, WHICH SHALL BE
 34 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND, AND HARDWARE SHALL BE EXPOSED
 AND USABLE FROM BOTH SIDES PER THE 2020 FBC ACC. SEC.
 404.2.7.
  
 D. WOULD YOU SHOW THE GRAB BARS PER THE 2020 FBC ACC
 SEC. 604.5.1 SIDE WALL AND 604.5.2 REAR WALL. THE GRAB
 BARS SHALL BE MEASURED TO THE TOP OF THE GRIPPING
 SURFACE PER THE 2020 FBC ACC SEC. 609.4.
  
 E. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION PER THE 2020 FBC ACC SEC. 609.4.
  
 F. SHOW THE TOILET IS 16 INCHES TO 18 INCHES TO THE
 CENTER PER THE 2020 FBC ACC SEC. 604.2 LOCATION. THE
 CLEAR FLOOR SPACE SHALL BE 60 INCHES MINIMUM MEASURED
 PERPENDICULAR FROM THE SIDEWALL, AND 56 INCHES MINIMUM
 MEASURED PERPENDICULAR FROM THE REAR WALL PER THE 2020
 FBC ACC. SEC. 604.3.1.
  
 G. THE TOILET PAPER DISPENSERS SHALL BE 7 INCHES
 MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER
 CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER PER
 THE 2020 FBC ACC SEC. 604.7.
  
 H. HANDICAP CAP WATER CLOSET FLUSH CONTROL SHALL BE
 HAND OPERATED OR AUTOMATIC AND SHALL BE 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR AND ON THE OPEN SIDE PER
 THE 2020 FBC ACC SEC. 604.9.5.
  
 J. LAVATORY WATER SUPPLY AND DRAINPIPES UNDER THE SIDE
 SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
 AGAINST CONTACT PER THE 2020 FBC ACC SEC. 606.5.
  
 K. THE URINALS SHALL BE 17 INCHES SHALL BE A MAXIMUM
 AND 13 1/2 INCHES PER THE 2020 FBC ACC. SEC. 605.2.
  
 L. THE REFLECTIVE PART OF THE MIRROR NEEDS TO BE 40
 INCHES TO THE REFLECTIVE SIDE PER THE 2020 FBC ACC SEC.
 603.3.
  
 M. SHOW THE HEIGHT FOR ALL PARTITIONS IN BETWEEN THE
 2020 FBC SEC. P 405.3.5. THE WALLS OR PARTITIONS SHALL
 BEGIN AT A HEIGHT NOT GREATER THAN 12 INCHES FROM AND
 EXTEND NOT LESS THAN 60 INCHES ABOVE THE FINISHED FLOOR
 SURFACE.
  
 N. SEATS OF WATER CLOSETS SHALL BE OPEN-FRONT TYPE PER
 2020 FBC P 425.3 WATER CLOSET SEATS.
  
 2. ON SHEET P001;
  
 A. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL
 SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE
 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P
 310.3. WOULD YOU PLEASE MAKE A NOTE ON THIS SHEET?
  
 B. FOR THE EYEWASH STATION, THE TEMPERATURE OF THE
 WATER SUPPLY SHALL ONLY BE CONTROLLED BY A
 TEMPERATURE-ACTUATED MIXING VALVE COMPLYING WITH ASSE
 1071 PER THE 2020 FBC P 411.3 WATER SUPPLY.
  
 C. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS, AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3 PER THE 2020 FBC
 SEC. 416.5 TEMPERED WATER FOR PUBLIC HAND-WASHING
 FACILITIES.
  
 D. IF AN ICEMAKER OR COFFEE MAKER IS PROVIDED, THEY
 SHALL BE EQUIPPED WITH AN IN-LINE VACUUM BREAKER THAT
 COMPLIES WITH ASSE 1024 PER THE 2020 FBC SEC.
 608.13.10.
  
 E. ON THE EWH DETAIL, PLEASE SHOW THE THERMAL EXPANSION
 DEVICE PER THE 2020 FBC SEC P 607.3.
  
  
 3. ON SHEET P101;
  
 A. WOULD YOU PLEASE SHOW THE MAIN SHUT-OFF VALVE FOR
 THE STRUCTURE PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 B. HOT WATER LINES LOOPED FOR THE RECIRCULATING SYSTEM
 IT IS NOT IN A CONTINUOUS LOOP. THERE IS A REQUIREMENT
 IN THE FLORIDA ENERGY CODE SEC. C404.6.1.
  
 C. THERE IS A TABLE THAT LIMITS THE BETWEEN THE SOURCE
 AND THE OUTLET; PLEASE REFER TO TABLE 405.5.1 FOR THE
 MAXIMUM ALLOWABLE PIPE LENGTH METHOD AND SIZE
 ACCORDANTLY.
  
 D. THE WC-2 IN WOMEN'S AND MEN'S ROOMS NEEDS TO BE
 LABELED AS A LAV. WOULD YOU PLEASE CORRECT PER THE WPB
 AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 E. IF POSSIBLE, SHOW RECIRCULATING PUMP AND SHUT-OFF
 VALVES IN THE WATER HEATER LOCATION PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 4. ON SHEET P102;
  
 A. ON THE ISOMETRIC ON THE MEN'S RESTROOM, IT SHOWS A
 WC-2, THEN IT SHOULD BE A LAV THEN URINAL, AND ON THE
 WOMEN'S WC-2 NEEDS TO BE A LAV. WOULD YOU PLEASE
 CORRECT PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 B. WOULD YOU PLEASE LABEL ALL LAVS ON THE ISOMETRIC PER
 THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION
 ON CONSTRUCTION DOCUMENTS.
  
 C. WOULD YOU PLEASE SHOW THE TRAP PRIMERS ON THE FLOOR
 DRAINS PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 D. WOULD YOU, PLEASE SIZE THE EYEWASH ON THE ISOMETRIC
 PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 E. WOULD YOU, PLEASE SHOW THE CLEAN-OUT OUTSIDE THE
 BUILDING DRAIN PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-10-25 Cont ID  
Sent By mpeterso Date 2021-10-25 Time 16:36 Rev Time 0.00
Received By mpeterso Date 2021-10-25 Time 16:35 Sent To  
Notes
2021-10-25 16:36:48REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-15 Cont ID  
Sent By pvalenti Date 2021-10-15 Time 17:42 Rev Time 0.00
Received By pvalenti Date 2021-10-15 Time 17:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-08-31 Cont ID  
Sent By medwards Date 2021-08-31 Time 07:10 Rev Time 0.00
Received By medwards Date 2021-08-31 Time 07:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-10-18 Cont ID  
Sent By eschneid Date 2021-10-18 Time 10:46 Rev Time 0.25
Received By eschneid Date 2021-10-18 Time 10:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-08-20 Cont ID  
Sent By eschneid Date 2021-08-20 Time 15:57 Rev Time 1.00
Received By eschneid Date 2021-08-20 Time 15:57 Sent To  
Notes
2021-08-20 15:58:19FAILED
  
 1) THE DESCRIPTION TAGS ON SHEET C2.1 ARE NOT LEGIBLE.
 THEY SHOW UP AS A SOLID MARK.
  
 2) THE WINDOW DECALS MUST BE SUBMITTED AS A SIGN PERMIT
 WITH THE SIGN SIZE AND THE AMOUNT OF GLAZING. THE
 WINDOW SIGNAGE MAY ONLY OCCUPY 10 PERCENT OF THE GLAZED
 AREA.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  