| Plan Review Stops For Permit 21080610 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
5 |
Status |
P |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-01-11 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-01-11 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2022-01-11 15:28:07 | UNITS UPDATED AS WELL AS PLANS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
F |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-14 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-14 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2021-12-14 16:42:08 | MARKETING LEVELS 19 AND 20 HAVE BEEN ASSIGNED SUITE | | | NUMBERS OF 1900 AND 2000, THESE SUITE NUMBERS SHOULD BE | | | REFLECTED IN THE PERMIT DOCUMENTATION. PLEASE EMAIL | | | [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-16 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-16 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2021-11-16 12:57:38 | MARKETING LEVELS 19 AND 20 HAVE BEEN ASSIGNED SUITE | | | NUMBERS OF 1900 AND 2000, THESE SUITE NUMBERS SHOULD BE | | | REFLECTED IN THE PERMIT DOCUMENTATION. PLEASE EMAIL | | | [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-11-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-08 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-08 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2021-11-08 09:55:39 | MARKETING LEVELS 19 AND 20 HAVE BEEN ASSIGNED SUITE | | | NUMBERS OF 1900 AND 2000, THESE SUITE NUMBERS SHOULD BE | | | REFLECTED IN THE PERMIT DOCUMENTATION. PLEASE EMAIL | | | [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-08-30 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-08-30 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2021-08-30 10:46:40 | MARKETING LEVELS 19 AND 20 HAVE BEEN ASSIGNED SUITE | | | NUMBERS OF 1900 AND 2000, THESE SUITE NUMBERS SHOULD BE | | | REFLECTED IN THE PERMIT DOCUMENTATION. PLEASE EMAIL | | | [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
N |
Date |
2021-12-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-20 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-20 |
Time |
06:18 |
Sent To |
|
|
| Notes |
| 2021-12-20 06:18:44 | TECHNICALLY THIS IS NOT AN INTERIOR RENOVATION, THIS IS | | | NEW CONSTRUCTION AS FIRST OCCUPANCY HAS NOT OCCURRED | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-23 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-23 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2021-11-23 13:55:16 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-09 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-09 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2021-11-09 15:09:04 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-08-25 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-25 |
Time |
07:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2022-01-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-19 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-19 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-12 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-12 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2022-01-12 13:02:38 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING (A 110) DEMOUNTABLE WALL DESCRIPTION ADDED - | | | FOR DEMOUNTABLE WALLS (WALLS 2, 6 AND 8) WITH MATERIAL | | | - PLEASE INCLUDE A NOTE THAT THE WALL PANELS ARE NON | | | COMBUSTIBLE PER FBC 603.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-22 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-22 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-23 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-23 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2021-11-23 13:55:57 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) REST ROOMS (1927) AND (2040) FBC 603.2.3 DOOR SWING. | | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE | | | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. | | | EXCEPTIONS: (2.) WHERE THE TOILET ROOM OR BATHING ROOM | | | IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING | | | WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC | | | OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING | | | INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR | | | ANY FIXTURE. (PLEASE SHOW THE CLEAR FLOOR SPACE) | | | | | | 2) PLEASE SHOW THE TYPE OF FIRE PROTECTION AND THE | | | HOURLY FIRE RATING REQUIRED FOR THE STRUCTURAL STEEL | | | BEAMS FBC TABLE 601 | | | | | | 3) BUILDING CONSTRUCTION TYPE SHOULD BE SHOWN PER FBC | | | 602.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-09 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-09 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2021-11-09 14:11:18 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) REST ROOMS (1927) AND (2040) FBC 603.2.3 DOOR SWING. | | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE | | | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. | | | EXCEPTIONS: (2.) WHERE THE TOILET ROOM OR BATHING ROOM | | | IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING | | | WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC | | | OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING | | | INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR | | | ANY FIXTURE. (PLEASE SHOW THE CLEAR FLOOR SPACE) | | | | | | 2) PLEASE SHOW THE TYPE OF FIRE PROTECTION AND THE | | | HOURLY FIRE RATING REQUIRED FOR THE STRUCTURAL STEEL | | | BEAMS FBC TABLE 601 | | | | | | 3) BUILDING CONSTRUCTION TYPE SHOULD BE SHOWN PER FBC | | | 602.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-25 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-25 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2021-08-25 11:59:45 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) DRAWING G002 AND G003 SHOW THE DESIGN PER 2018 IBC - | | | SHOULD BE 2020 FBC - PLEASE CORRECT. | | | 2) PLEASE SHOW THE STAIR LANDING DIMENSIONS TO COMPLY | | | WITH FBC 1011.6 | | | 3) PLEASE SHOW STAIR RISERS TO COMPLY WITH FBC | | | 1011.5.5.3 SOLID RISERS. RISERS SHALL BE SOLID. | | | EXCEPTIONS:(1).SOLID RISERS ARE NOT REQUIRED FOR | | | STAIRWAYS THAT ARE NOT REQUIRED TO COMPLY WITH SECTION | | | 1009, PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT | | | PERMIT THE PASSAGE OF A SPHERE WITH A DIAMETER OF 4 | | | INCHES (102 MM). | | | 4) PLEASE SHOW GLAZED GUARD RAIL AND HANDRAILS TO | | | COMPLY WITH FBC 2407.1MATERIALS. GLASS USED IN A | | | HANDRAIL, GUARDRAIL OR GUARD SECTION SHALL BE LAMINATED | | | GLASS CONSTRUCTED OF FULLY TEMPERED OR | | | HEAT-STRENGTHENED GLASS AND SHALL COMPLY WITH CATEGORY | | | II OR CPSC 16 CFR PART 1201 OR CLASS A OF ANSI Z97.1. | | | GLAZING IN RAILING IN-FILL PANELS SHALL BE OF AN | | | APPROVED SAFETY GLAZING MATERIAL THAT CONFORMS TO THE | | | PROVISIONS OF SECTION 2406.1.1. FOR ALL GLAZING TYPES, | | | THE MINIMUM NOMINAL THICKNESS SHALL BE 1/4 INCH (6.4 | | | MM). | | | 5) PLEASE SHOW THE GLAZING IN HAZARDOUS LOCATIONS TO BE | | | SAFETY GLAZING PER FBC 2406.1. SAFETY GLAZING IS | | | REQUIRED FOR THE GLAZED LIGHTED WALL AT THE BOTTOM OF | | | THE STAIR LANDING FBC 2406.4.7 | | | 6) PLEASE SHOW THE DOOR MANEUVERING CLEARANCE (18" | | | BESIDE THE LATCH SIDE) FOR THE DOOR AT CORRIDOR 2033 - | | | FBC A 404.2.4 | | | 7) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR | | | DIMENSIONS FROM THE FLOOR TO THE BOTTOM OF THE | | | "REFLECTIVE SURFACE" FBC A 603.3 MIRRORS. | | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. | | | 8) DRAWING A403 SHOWS THE MAXIMUM HEIGHT DIMENSION FOR | | | THE GRAB BAR TO THE CENTER - 36" SHOULD BE THE MAXIMUM | | | DIMENSION TO THE TOP OF THE GRAB BAR PER FBC A 609.4 | | | POSITION OF GRAB BARS. | | | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, | | | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE, | | | 9) RESTROOMS IN THE OFFICES NEED TO COMPLY WITH FBC | | | ACCESSIBILITY FBC 213.2 TOILET ROOMS AND BATHING ROOMS. | | | WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL | | | COMPLY WITH 603. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-01-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-19 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-19 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-12 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-12 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-11-16 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-11-09 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-25 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-25 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2021-08-25 16:47:21 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-102 | | | | | | CONFERENCE ROOM #2012 WALLS OUTLETS MISSING PER | | | 210.71(B)(1) | | | | | | 210.71(B)(1) RECEPTACLE OUTLETS IN FIXED WALLS. | | | RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE | | | WITH 210.52(A)(1) THROUGH (A)(4). | | | | | | PAGE E-101 | | | | | | CONFERENCE ROOM #1927 WALLS OUTLETS MISSING PER | | | 210.71(B)(1) | | | | | | 210.71(B)(1) RECEPTACLE OUTLETS IN FIXED WALLS. | | | RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE | | | WITH 210.52(A)(1) THROUGH (A)(4). | | | | | | PAGES E-1-1, AND E102 | | | | | | TAMPER RESISTANT OUTLETS REQUIRED BY 406.12(5) MISSING. | | | | | | 406.12 TAMPER-RESISTANT RECEPTACLES. ALL 15- AND | | | 20-AMPERE, | | | 125- AND 250-VOLT NONLOCKING-TYPE RECEPTACLES IN THE | | | AREAS SPECIFIED IN 406.12(1) THROUGH (7) SHALL BE | | | LISTED TAMPERRESISTANT RECEPTACLES. | | | (1) DWELLING UNITS IN ALL AREAS SPECIFIED IN 210.52 AND | | | 550.13 | | | (2) GUEST ROOMS AND GUEST SUITES OF HOTELS AND MOTELS | | | (3) CHILD CARE FACILITIES | | | (4) PRESCHOOLS AND ELEMENTARY EDUCATION FACILITIES | | | (5) BUSINESS OFFICES, CORRIDORS, WAITING ROOMS AND THE | | | LIKE IN | | | CLINICS, MEDICAL AND DENTAL OFFICES AND OUTPATIENT | | | FACILITIES | | | (6) SUBSET OF ASSEMBLY OCCUPANCIES DESCRIBED IN 518.2 | | | TO | | | INCLUDE PLACES OF WAITING TRANSPORTATION, GYMNASIUMS, | | | SKATING RINKS, AND AUDITORIUMS | | | (7) DORMITORIES |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-01-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-12-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-11-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-11-10 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-08-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-08-25 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2022-01-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-19 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-18 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-12 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-11 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-12-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-28 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-14 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-12-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-11-15 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-11-10 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-11-08 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2021-11-10 10:19:59 | PLANS ARE NOT VERSIONED PROPERLY, SEE MECHANICAL PAGES | | | FOR EXAMPLES. SEE ALSO PROJECTDOX INSTRUCTIONS AND | | | QUICK START GUIDE. PLEASE EMAIL [email protected] | | | TO COORDINATE FOR THEM TO DELETE THE PAGES WHICH YOU | | | UPLOADED THAT DID NOT VERSION. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-09-02 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-09-02 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-09-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-09-02 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-08-23 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2022-01-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-19 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-19 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-12 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-12 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2022-01-12 16:07:54 | THE FLORIDA BUILDING CODE MECHANICAL SECTION 403.3.1.1 | | | AND TABLE 403.3.1.1 DICTATES THAT WE USE THE | | | VENTILATION TABLE TO CALCULATE THE OUTDOOR AIR REQUIRED | | | FOR THE USE OF SPACE IN ALL BUILDINGS. THE TABLE HAS A | | | PARTICULAR MINIMUM OCCUPANT DENSITY THAT WE USE TO | | | CALCULATE THE OCCUPANTS FOR EACH SPACE. WE DO NOT USE | | | THE ARCHITECTURAL OCCUPANT COUNT TO SIZE THE MECHANICAL | | | SYSTEMS UNLESS THE ARCHITECT?S OCCUPANT COUNT IS HIGHER | | | THAN THE MINIMUM REQUIRED BY TABLE 403.3.1.1 IN THE | | | MECHANICAL CODE BOOK. UPON REVIEWING THE OUTDOOR AIR | | | CALCULATIONS FOR THIS PROJECT I SEE THAT THE CONFERENCE | | | ROOMS AND THE LOBBY IN THE 1900 AND IN 2000 HAVE NOT | | | BEEN SIZED USING THE TABLE 403.3.1.1 FOR THE OUTDOOR | | | AIR CALCULATIONS. THE OUTDOOR AIR NUMBERS ARE LOW | | | COMPARED TO WHAT WOULD BE REQUIRED. ONE EXAMPLE IS | | | ROOMS ?1901/1931/1934 TRAINING? IT IS LISTED AS | | | CONFERENCE/MEETING WITH A TOTAL SQUARE FOOTAGE AS 2,351 | | | WITH TOTAL OUTDOOR AIR REQUIRED AS 401.06 CFM?S. THE | | | CALCULATION IS ? 2351/1000 = 2.351; 2.351 X 50 = 117.55 | | | OR 118 OCCUPANTS; 118 X 5CFM = 590CFM; 2351 X .06 = | | | 141.06CFM; 590 + 141.06 = 731.06 OR 731 CFM?S OF | | | OUTDOOR AIR REQUIRED FOR THIS SPACE. PLEASE CORRECT THE | | | AREAS THAT WERE NOT CALCULATED USING THE TABLE | | | 403.3.1.1 AND RESUBMIT THE OUTDOOR AIR CALCULATIONS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-17 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-17 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2021-12-17 15:06:18 | PLEASE RESPOND TO 1ST CYCLE REVIEW COMMENTS BELOW. | | | | | | | | | PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH | | | USE OF SPACE FOR EACH FLOOR. FBC M 403.3.1.1 AND TABLE | | | 403.3.1.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-19 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-19 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2021-11-19 13:44:28 | PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH | | | USE OF SPACE FOR EACH FLOOR. FBC M 403.3.1.1 AND TABLE | | | 403.3.1.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-25 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-25 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2021-08-25 10:11:32 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21080610 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS MD101 AND MD102 INDICATE 2 NEW EXHAUST DUCTS | | | A 10 X 10 AND AN 8 X 8 BUT SHEETS M101 AND M102 SHOW | | | ONLY 1 NEW 18 X 8 EXHAUST DUCT CONNECTION TO THE | | | EXHAUST DUCT IN THE MECHANICAL ROOM. PLEASE BE | | | CONSISTENT. FBC 107.2.1 | | | | | | 2) SHEET M101: PLEASE PROVIDE A DETAIL OF THE RETURN | | | AIR PATH FROM TENANT SPACE TO THE MECHANICAL ROOM. DO | | | THE WALLS BUILT AT THE COFFEE/COPY AREAS GO TO THE | | | FLOOR ABOVE? WE MUST MAINTAIN THE RETURN AIR FLOW BACK | | | TO THE MECHANICAL ROOM FROM THE TENANT SPACE. FBC | | | 107.2.1 | | | | | | 3) SHEET M102: PLEASE PROVIDE A DETAIL OF THE RETURN | | | AIR PATH FROM TENANT SPACE TO THE MECHANICAL ROOM. DO | | | THE WALLS BUILT AT THE UNISEX BATHROOM AND OFFICE 2041 | | | AND THE FILES ROOM AREAS GO TO THE FLOOR ABOVE? WE MUST | | | MAINTAIN THE RETURN AIR FLOW BACK TO THE MECHANICAL | | | ROOM FROM THE TENANT SPACE. FBC 107.2.1 | | | | | | 4) SHEET M102: TOILET ROOM 2050 APPEARS TO HAVE AN | | | EXHAUST RATE OF 30 CFM?S? PLEASE SHOW THE CONNECTION | | | POINT OF ALL EXHAUST DUCT TO THE EXHAUST PLENUM. FBC | | | 107.2.1 | | | | | | 5) SHEETS M101 AND M102: PLEASE SHOW THE EXHAUST DUCT | | | SIZES AND CFM?S FOR EACH BATHROOM. FBC M TABLE | | | 403.3.1.1 | | | | | | 6) SHEET M401: LEVEL 20 RESTROOMS DIAGRAM, PLEASE SHOW | | | THE WOMEN?S EXHAUST CFM?S ON THE DRAWING. FBC M TABLE | | | 403.3.1.1 | | | | | | 7) SHEET M701: PLEASE PROVIDE THE BATHROOM EXHAUST FAN | | | INFORMATION TO SHOW THE MAX. CFM?S FOR THE FAN. FBC | | | 107.2.1 | | | | | | 8) SHEET M701: PLEASE PROVIDE THE OUTDOOR AIR | | | CALCULATIONS FOR EACH USE OF SPACE FOR BOTH FLOORS. FBC | | | M 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-12 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-12 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2021-12-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-23 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-23 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2021-12-23 15:45:06 | 4TH REVIEW FBC-2020 PLUMBING | | | PERMIT- 21080610 | | | 12/23/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) FAILED COMMENT #7 FROM PREVIOUS REVIEWS- SHEET A401: | | | THE HALSEY TAYLOR BARRIER FREE DRINKING FOUNTAINS | | | LOCATED IN THE CORRIDOR ARE NOT IN COMPLIANCE WITH SEC. | | | 307.2 PROTRUSION LIMITS FBC ACC. TYPICALLY THESE TYPES | | | OF FOUNTAINS ARE LOCATED INSIDE NICHES OR HAVE WING | | | WALLS INSTALLED AS GUARDS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2021-12-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-02 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-02 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2021-12-02 14:17:01 | 3RD REVIEW FBC-2020 PLUMBING | | | PERMIT- 21080610 | | | 12/2/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST AND 2ND REVIEWS ARE LISTED BELOW WITH ADDITONAL | | | NOTES IN CAP LETTERS FOR FURTHER CLARIFICATIONS. PLEASE | | | NOTE THAT THE REQUESTED RESPONSE NARRATIVE TO THE 2ND | | | REVIEW COMMENTS WAS NOT PROVIDED, AND THE ARCHITECTURAL | | | PLAN SHEETS SHOWING ACCESSIBILITY COMPLIANCES WERE NOT | | | CORRECTED. | | | | | | 1) FAILED. SHEET A101: SHOW THE CLEAR FLOOR SPACE | | | DIAGRAMS AND DIMENSIONS FOR THE ACCESSIBLE SINKS IN | | | ROOMS 1905, 1929, & 1935- SECTION 606.2 FBC ACC. NOT | | | PROVIDED. | | | | | | 2) FAILED. A108, A401: THE REQUIRED CLEAR FLOOR SPACE | | | FOR THE WATER CLOSET IN PRIVATE OFFICE BATHROOM 2025 | | | HAS NOT BEEN PROVIDED, AND WILL OVERLAP THE LAVATORY- | | | SECTIONS 604.3.1 & 604.3.2 FBC ACC. NOT PROVIDED. | | | | | | 4) FAILED ITEMS A, B, D, E, F, G, H, I, J. A401 & A402: | | | FBC ACCESSIBILITY CORRECTIONS AND MISSING DETAILS FOR | | | MEN'S AND WOMEN'S BATHROOMS. | | | A) TURNING SPACE DIAGRAMS AND DIMENSIONS IN THE | | | WHEELCHAIR ACCESSIBLE COMPARTMENTS- 304.3. | | | B) LENGTH AND SPACING MEASUREMENTS FOR THE REAR AND | | | SIDE WALL WATER CLOSET GRAB BARS IN THE WHEELCHAIR | | | ACCESSIBLE COMPARTMENTS AND THE AMBULATORY | | | COMPARTMENTS- 604.5 | | | D) REMOVE VERTICAL GRAB BARS. THEY ARE NOT REQUIRED PER | | | FBC ACC AND ARE IN CONFLICT WITH 609.4 WHICH REQUIRES | | | GRAB BARS TO BE INSTALLED IN A HORIZONTAL POSITION. | | | E) INDICATE MIRROR MEASUREMENTS TO THE REFLECTIVE | | | SURFACES AND NOT THE BOTTOM OF THE MIRRORS- 603.3. | | | F) HEIGHTS OF THE LAVATORIES IN THE ACCESSIBLE | | | COMPARTMENTS- 606.3. | | | G) KNEE AND TOE CLEARANCES FOR THE ACCESSIBLE | | | LAVATORIES- 306.2, 306.3, & 606.2. | | | H) RELOCATE WATER CLOSET FLUSH CONTROLS TO THE OPEN | | | SIDES OF THE FIXTURES- 604.6. | | | I) URINAL RIM HEIGHT FOR THE FLOOR- 605.2. | | | J) HEIGHT OF THE PAPER TOWEL DISPENSER- 308. | | | | | | 3) FAILED ITEMS A, B, C, D. A401 & A403: FBC ACC | | | CORRECTIONS AND MISSING DETAILS FOR PRIVATE OFFICE | | | BATHROOM 2025. | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSET- 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORY- SECTION 606.2. (NOTE- ITEM 1 EXEMPTS THE KNEE | | | AND TOE CLEARANCES.) | | | C) TURNING SPACE DIAGRAM AND DIAMETER- 304.3. | | | D) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | REFLECTIVE SURFACE- 603.3. | | | E) WATER CLOSET GRAB BAR REINFORCEMENT LOCATIONS BASED | | | ON SECTIONS 604.5 & 609.4. | | | | | | 4) FAILED ITEM A. A401 & A403: FBC ACC CORRECTIONS AND | | | MISSING DETAILS FOR PRIVATE OFFICE BATHROOM 2050. | | | A) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | REFLECTIVE SURFACE- SECTION 603.3. | | | | | | 5) FAILED ITEMS A, B, C, E, F. A401 & A403: FBC ACC | | | CORRECTIONS AND MISSING DETAILS FOR UNISEX BATHROOMS | | | 1928 & 2040. | | | A) THE DOORS SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACES FOR THE LAVATORIES- 603.2.3. | | | B) REMOVE VERTICAL GRAB BARS. THEY ARE NOT REQUIRED PER | | | FBC ACC AND ARE IN CONFLICT WITH 609.4 WHICH REQUIRES | | | GRAB BARS TO BE INSTALLED IN A HORIZONTAL POSITION. | | | C) INDICATE MIRROR MEASUREMENTS TO THE REFLECTIVE | | | SURFACES AND NOT THE BOTTOM OF THE MIRRORS- 603.3. | | | E) HEIGHTS OF THE ACCESSIBLE LAVATORIES- 606.3. | | | F) KNEE AND TOE CLEARANCES FOR THE ACCESSIBLE | | | LAVATORIES- 306.2, 306.3, & 606.2. | | | | | | 6) FAILED ITEMS A, B. A405: FBC ACC CORRECTIONS AND | | | MISSING DETAILS FOR ROOMS 1905, 1917, 1929, & 1935. | | | A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR SINKS, | | | DISHWASHERS, REFRIGERATORS- 686.2 & 804.6. | | | B) CLEAR FLOOR SPACES, REACH HEIGHTS, AND OPERABLE PART | | | COMPLIANCE FOR APPLIANCES INCLUDING THE COFFEE | | | DISPENSER AND MICROWAVES- 309 & 804.6.2. | | | | | | 7) FAILED. A401: REFER TO SECTIONS 306, 307, AND 602 | | | FBC ACC AND PROVIDE DRINKING FOUNTAIN INSTALLATION | | | DETAILS AND ELEVATION VIEWS SHOWING KNEE AND TOE | | | CLEARANCES. INDICATE HOW COMPLIANCE WITH SECTION 307.2 | | | PROTRUSION LIMITS IS BEING MET. | | | | | | 8) FAILED. A403: PREVIOUS REVIEW REQUEST TO PROVIDE | | | NON-ABSORBENT WALL FINISH MATERIALS FOR THE MOP SINK | | | SURROUNDS WAS NOT PROVIDED- SECTION 1210.2.2 FBC B. | | | | | | 9) FAILED. P202 & P203: PLEASE ADD THE NOTES FOR THE | | | BACKFLOW PREVENTER AND WATER HAMMER ARRESTOR FOR THE | | | SUPPLY LINE TO THE COFFEE MAKER- SEE NOTES ON P202. | | | PLEASE SEE TABLE 608.3 & SECTION 608.17.1.2 FBC P- THE | | | ASSE 1024 STANDARD IS APPLICABLE TO | | | DUAL-CHECK-VALVE-TYPE BACKFLOW PREVENTERS NOT INLINE | | | VACUUM BREAKERS. | | | | | | 10) FAILED. P402: HWR & HW LINE SYMBOLS ARE NOT SHOWN | | | CORRECTLY ON THE 19TH FLOOR DOMESTIC WATER PLAN- | | | SECTION 107.2.1 WPB. SOLID LINES INSTEAD OF BROKEN | | | LINES ARE MISREPRESENTING HWR & HW LINES. | | | | | | 12) FAILED. P601 DETAIL 1: THE HWR LINE SHALL BE ROUTED | | | TO THE COLD WATER INLET PIPE OF THE WATER HEATER AND | | | THE COLD WATER INLET PIPE CONNECTION TO THE MASTER | | | THERMOSTATIC MIXING VALVE- SECTION 607.2.2 FBC P. NO | | | CHANGES WERE MADE TO THE DETAIL TO SHOW COMPLIANCE. | | | | | | 13) FAILED. P503 & P601: PLEASE INDICATE HOW TEMPERED | | | WATER WILL BE DELIVERED FROM THE LAVATORY FAUCETS- | | | SECTION 419.5 FBC P. A MASTER MIXING VALVE PROVIDED. | | | PLEASE INDICATE THE TEMPERATUURE OF THE WATER BEING | | | SUPPLIED TO THE PLUMBING FIXTURES. PLEASE NOTE THE | | | REQUIRED TEMPERED WATER AT THE LAVATORIES SHALL BE AT A | | | TEMPERATURE RANGE BETWEEN 85 AND 110 DEGREES. HOT WATER | | | HAS A TEMPERATURE OF 110 DEGREES OR GREATER- SECTION | | | 202. | | | | | | 14) FAILED. P602: THE REQUESTED UL FIRESTOPPING | | | ASSEMBLIES FOR INSULATED AND NON-INSULATED PIPE | | | PENETRATIONS WAS NOT PROVIDED. THE NARRATIVE REFERENCES | | | SHEETS A603 & A604 HOWEVER THE DETAILS ARE NOT SHOWN ON | | | THOSE SHEETS- SECTION 315.1 FBC P AND SECTION 714.4.1.2 | | | FBC B. NOT PROVIDED. | | | | | | 15) FAILED. P701: PLEASE PROVIDE SCHEDULES FOR THE | | | WATER HAMMER ARRESTORS, MIXING VALVE, BACKFLOW | | | PREVENTERS, AND TRAP PRIMERS- SECTIONS 604.9, 607.2.1, | | | 608.3, AND 1002.4.1.1 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-10 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-09 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2021-11-10 11:39:59 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 21080610 | | | 11/9/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENTS BELOW ARE | | | FOLLOW-UP TO 1ST REVIEW COMMENTS AND REVIEW OF THE | | | REVISED PLANS AND RESPONSE NARRATIVE. | | | | | | 1) SHEET A101: SHOW THE CLEAR FLOOR SPACE DIAGRAMS AND | | | DIMENSIONS FOR THE ACCESSIBLE SINKS IN ROOMS 1905, | | | 1929, & 1935- SECTION 606.2 FBC ACC. | | | | | | 2) A108, A401: THE REQUIRED CLEAR FLOOR SPACE FOR THE | | | WATER CLOSET IN PRIVATE OFFICE BATHROOM 2025 HAS NOT | | | BEEN PROVIDED, AND WILL OVERLAP THE LAVATORY- SECTIONS | | | 604.3.1 & 604.3.2 FBC ACC. | | | | | | 4) A401 & A402: FBC ACCESSIBILITY CORRECTIONS AND | | | MISSING DETAILS FOR MEN'S AND WOMEN'S BATHROOMS. | | | A) TURNING SPACE DIAGRAMS AND DIMENSIONS IN THE | | | WHEELCHAIR ACCESSIBLE COMPARTMENTS- 304.3. | | | B) LENGTH AND SPACING MEASUREMENTS FOR THE REAR AND | | | SIDE WALL WATER CLOSET GRAB BARS IN THE WHEELCHAIR | | | ACCESSIBLE COMPARTMENTS AND THE AMBULATORY | | | COMPARTMENTS- 604.5 | | | C) SHOW GRAB BAR HEIGHTS TO THE TOPS OF THE GRIPPING | | | SURFACES- 609.4. | | | D) REMOVE VERTICAL GRAB BARS. THEY ARE NOT REQUIRED PER | | | FBC ACC AND ARE IN CONFLICT WITH 609.4 WHICH REQUIRES | | | GRAB BARS TO BE INSTALLED IN A HORIZONTAL POSITION. | | | E) INDICATE MIRROR MEASUREMENTS TO THE REFLECTIVE | | | SURFACES AND NOT THE BOTTOM OF THE MIRRORS- 603.3. | | | F) HEIGHTS OF THE LAVATORIES IN THE ACCESSIBLE | | | COMPARTMENTS- 606.3. | | | G) KNEE AND TOE CLEARANCES FOR THE ACCESSIBLE | | | LAVATORIES- 306.2, 306.3, & 606.2. | | | H) RELOCATE WATER CLOSET FLUSH CONTROLS TO THE OPEN | | | SIDES OF THE FIXTURES- 604.6. | | | I) URINAL RIM HEIGHT FOR THE FLOOR- 605.2. | | | J) HEIGHT OF THE PAPER TOWEL DISPENSER- 308. | | | | | | 3) A401 & A403: FBC ACC CORRECTIONS AND MISSING DETAILS | | | FOR PRIVATE OFFICE BATHROOM 2025. | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSET- 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORY- SECTION 606.2. (NOTE- ITEM 1 EXEMPTS THE KNEE | | | AND TOE CLEARANCES.) | | | C) TURNING SPACE DIAGRAM AND DIAMETER- 304.3. | | | D) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | REFLECTIVE SURFACE- 603.3 | | | E) WATER CLOSET GRAB BAR REINFORCEMENT LOCATIONS BASED | | | ON SECTIONS 604.5 & 609.4. | | | | | | 4) A401 & A403: FBC ACC CORRECTIONS AND MISSING DETAILS | | | FOR PRIVATE OFFICE BATHROOM 2050. | | | A) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | REFLECTIVE SURFACE- SECTION 603.3 | | | B) WATER CLOSET GRAB BAR REINFORCEMENT LOCATIONS BASED | | | ON SECTIONS 604.5 & 609.4. | | | | | | 5) A401 & A403: FBC ACC CORRECTIONS AND MISSING DETAILS | | | FOR UNISEX BATHROOMS 1928 & 2040. | | | A) THE DOORS SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACES FOR THE LAVATORIES- 603.2.3. | | | B) REMOVE VERTICAL GRAB BARS. THEY ARE NOT REQUIRED PER | | | FBC ACC AND ARE IN CONFLICT WITH 609.4 WHICH REQUIRES | | | GRAB BARS TO BE INSTALLED IN A HORIZONTAL POSITION. | | | C) INDICATE MIRROR MEASUREMENTS TO THE REFLECTIVE | | | SURFACES AND NOT THE BOTTOM OF THE MIRRORS- 603.3. | | | E) HEIGHTS OF THE ACCESSIBLE LAVATORIES- 606.3. | | | F) KNEE AND TOE CLEARANCES FOR THE ACCESSIBLE | | | LAVATORIES- 306.2, 306.3, & 606.2. | | | | | | 6) A405: FBC ACC CORRECTIONS AND MISSING DETAILS FOR | | | ROOMS 1905, 1917, 1929, & 1935. | | | A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR SINKS, | | | DISHWASHERS, REFRIGERATORS- 686.2 & 804.6. | | | B) CLEAR FLOOR SPACES, REACH HEIGHTS, AND OPERABLE PART | | | COMPLIANCE FOR APPLIANCES INCLUDING THE COFFEE | | | DISPENSER AND MICROWAVES- 309 & 804.6.2. | | | | | | 7) A401: REFER TO SECTIONS 306, 307, AND 602 FBC ACC | | | AND PROVIDE DRINKING FOUNTAIN INSTALLATION DETAILS AND | | | ELEVATION VIEWS SHOWING KNEE AND TOE CLEARANCES, SPOUT | | | HEIGHTS, AND SPOUT LOCATIONS. INDICATE HOW COMPLIANCE | | | WITH SECTION 307.2 PROTRUSION LIMITS IS BEING MET. | | | | | | 8) A403: PREVIOUS REVIEW REQUEST TO PROVIDE | | | NON-ABSORBENT WALL FINISH MATERIALS FOR THE MOP SINK | | | SURROUNDS WAS NOT PROVIDED- SECTION 1210.2.2 FBC B. | | | | | | 9) P203: PLEASE ADD THE NOTES FOR THE BACKFLOW | | | PREVENTER AND WATER HAMMER ARRESTOR FOR THE SUPPLY LINE | | | TO THE COFFEE MAKER- SEE NOTES ON P202. | | | | | | 10) P402: HWR & HW LINE SYMBOLS ARE NOT SHOWN CORRECTLY | | | ON THE 19TH FLOOR DOMESTIC WATER PLAN- SECTION 107.2.1 | | | WPB. | | | | | | 11) P502: LABEL THE SIZES OF THE 20TH FLOOR P3 DRAINS | | | AND DRAIN STACK SIZES- SECTION 710.1 FBC P. | | | | | | 12) P601 DETAIL 1: THE HWR LINE SHALL BE ROUTED TO THE | | | COLD WATER INLET PIPE OF THE WATER HEATER AND THE COLD | | | WATER INLET PIPE CONNECTION TO THE MASTER THERMOSTATIC | | | MIXING VALVE- SECTION 607.2.2 FBC P. | | | | | | 13) P503 & P601: PLEASE INDICATE HOW TEMPERED WATER | | | WILL BE DELIVERED FROM THE LAVATORY FAUCETS- SECTION | | | 419.5 FBC P. | | | | | | 14) P602: THE REQUESTED UL FIRESTOPPING ASSEMBLIES FOR | | | INSULATED AND NON-INSULATED PIPE PENETRATIONS WAS NOT | | | PROVIDED. THE NARRATIVE REFERENCES SHEETS A603 & A604 | | | HOWEVER THE DETAILS ARE NOT SHOWN ON THOSE SHEETS- | | | SECTION 315.1 FBC P AND SECTION 714.4.1.2 FBC B. | | | | | | 15) P701: PLEASE PROVIDE SCHEDULES FOR THE WATER HAMMER | | | ARRESTORS, MIXING VALVE, THERMAL EXPANSION TANK, | | | BACKFLOW PREVENTERS, AND TRAP PRIMERS- SECTIONS 604.9, | | | 607.2.1, 607.3, 608.3, AND 1002.4.1.1 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | 2021-11-10 09:16:45 | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-09-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-09-02 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-08-31 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2021-09-02 13:25:56 | 09/02/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET G002 AND G003, THE UNDER APPLICABLE CODES | | | REFER TO THE 2018 AMENDMENT WE USE THE AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, 6TH EDITION (2017), CHAPTER | | | 1, ADMINISTRATION. WE CAN PROVIDE A COPY IF YOU WOULD | | | NEED ONE. WOULD YOU PLEASE REMOVE THE PALM BEACH COUNTY | | | LOCAL AMENDMENTS EFFECTIVE DECEMBER 31, 2020, IS NOT A | | | SUPPORTED REFERENCE? IT DOES NOT APPLY TO THESE PLANS | | | PER THE WPB AMENDMENTS TO FBC 102.3 APPLICATION OF | | | REFERENCES? | | | | | | 2. ON SHEET A101; | | | A. THERE ARE TWO BREAK ROOMS IN 1917, 1935, AND A | | | COFFEE IN 1904 AND 1929 WITH SINKS. WOULD YOU PLEASE | | | PROVIDE A DETAIL SHOWING THE CLEAR FLOOR SPACE FOR THE | | | SINK WHERE APPLICABLE PER THE 2020 FBC SEC? ACC 305.3. | | | | | | B. IN WOMEN'S AND MEN'S RESTROOMS, THE ACCESSIBLE | | | TOILET IN NEW CONSTRUCTION, THE WHEELCHAIR-ACCESSIBLE | | | TOILET COMPARTMENT SHALL CONTAIN AN ACCESSIBLE LAVATORY | | | WITHIN IT PER THE 2020 FBC ACC SEC. 604.8.1.6 LAVATORY. | | | | | | 3. ON SHEET A 108, THERE ARE TWO OFFICES WITH RESTROOMS | | | TO PRIVATE OFFICES. WOULD YOU PLEASE PROVIDE THE | | | ACCESSIBILITY TO COMPLY WITH 2020 FBC ACC SECS. 603 AND | | | 213.2. | | | | | | 4. ON SHEET A 401; | | | | | | A. WOULD YOU PLEASE PROVIDE PLUMBING FIXTURE | | | CALCULATIONS AND A SCHEDULE SHOWING THE REQUIRED AND | | | PROVIDED FIXTURES IN COMPLIANCE WITH THE 2020 FBC TABLE | | | 403.3 FBC P. | | | | | | B. THE DETAILS 1A AND 1C, WOULD YOU PLEASE PROVIDE THE | | | CLEAR FLOOR SPACE FOR THE LAV AND THE TOILET WITH THE | | | DIMENSIONS THE APPLIES PER THE 2020 FBC ACC SEC. 606.2. | | | 2 CLEAR FLOOR SPACE. | | | | | | C. ON DETAIL 4A, THE UNISEX RESTROOM ON THE CLEAR FLOOR | | | SPACE FOR THE WATER CLOSET IS OVERLAPPING WITH A LAV. | | | NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED | | | WITHIN THE REQUIRED WATER CLOSET CLEARANCE PER THE 2020 | | | FBC AC SEC. 604.3.2 OVERLAP. | | | | | | D. ON THAT SAME DETAIL, WOULD YOU PLEASE PROVIDE THE | | | CLEAR FLOOR SPACE DIMENSIONS FOR THE TRUING RADIUS, | | | LAVS, AND WATER CLOSET PER THE 2020 FBC ACC SEC. 606.2. | | | 2 CLEAR FLOOR SPACE. | | | | | | E. ON DETAIL 4A WOMEN'S AND MEN'S RESTROOMS, THERE IS | | | AN ACCESSIBLE STALL THAT HAS A WATER CLOSET SHALL | | | CONTAIN AN ACCESSIBLE LAVATORY WITHIN IT PER THE 2020 | | | FBC ACC SEC. 604.8.1.6 604.8.1.6 LAVATORY. | | | | | | F. ON THOSE RESTROOMS, SOME STALLS SEEM TO BE | | | AMBULATORY, AND IF SO, THE DOOR WILL REQUIRE TO SWING | | | TO THE OUTSIDE PER THE 604.8.2 AMBULATORY ACCESSIBLE | | | COMPARTMENTS. | | | | | | G. ON DETAIL 4A WOMEN'S AND MEN'S REST, WOULD YOU | | | PLEASE PROVIDE THE CLEAR FLOOR SPACE DIMENSIONS FOR THE | | | TRUING RADIUS, WATER FOUNTAIN, LAVS, AND WATER CLOSET | | | PER THE 2020 FBC ACC SEC. 606.2. 2 CLEAR FLOOR SPACE. | | | | | | H. AS REQUESTED IN PREVIOUS COMMENTS, THERE ARE TWO | | | BRAKE ROOMS AND TWO COFFEE ROOMS THAT ARE NOT SHOWN | | | WITH SINKS AND NO CLEAR SPACE FOR ACCESSIBILITY. WOULD | | | YOU PLEASE PROVIDE DETAIL FOR THE ONES THAT APPLY PER | | | THE 2020 FBC ACC SEC. 606.2. 2 CLEAR FLOOR SPACE. | | | | | | I. THERE SEEMS TO BE A SECOND WATER DRINKING FOUNTAIN | | | NEXT TO THE UNISEX RESTROOM, AND THERE IS NO DETAIL | | | THAT WILL REQUIRE A CLEAR FLOOR SPACE WITH DIMENSION. | | | IF SO, WOULD YOU PLEASE PROVIDE PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | J. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL | | | SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE | | | 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P | | | 310.3. PLEASE MAKE A NOTE ON THIS SHEET. | | | | | | | | | 5. ON SHEET A 402; | | | | | | A. THERE IS A VERTICAL GRAB BAR, BUT THEY SHALL BE | | | INSTALLED IN A HORIZONTAL POSITION PER THE 2020 FBC ACC | | | SEC. 609.4. | | | | | | B. DOOR HARDWARE SHALL BE 34 INCHES MINIMUM AND 48 | | | INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE | | | SLIDING DOORS ARE FULLY OPEN, OPERATING HARDWARE SHALL | | | BE EXPOSED AND USABLE FROM BOTH SIDES PER THE 2020 FBC | | | ACC. SEC. 404.2.7. | | | | | | C. ON DETAIL E4, THE URINAL IS MISSING; THE HEIGHT | | | SHALL BE 17 INCHES SHALL BE A MAXIMUM, AND 13 1/2 | | | INCHES PER THE 2020 FBC ACC. SEC. 605.2. WOULD YOU | | | PLEASE SHOW THE HEIGHT OF THE PARTITION NOT GREATER | | | THAN 12 INCHES FROM AND EXTEND NOT LESS THAN 60 INCHES | | | PER THE 2020 FBC SEC. P 405.3.5 URINAL PARTITIONS. | | | | | | D. ON DETAIL E4, THE REFLECTIVE PART OF THE MIRROR | | | NEEDS TO BE THE 40 INCHES TO THE REFLECTIVE SIDE FOR | | | ONLY THE ACCESSIBLE LAV PER THE 2020 FBC ACC SEC. | | | 603.3. | | | | | | E. WOULD YOU, PLEASE SHOW THE GRAB BARS THAT SHALL BE | | | MEASURED TO THE TOP OF THE GRIPPING SURFACE PER THE | | | 2020 FBC ACC SEC. 609.4. | | | | | | F. THE WATER CLOSET IN THE ACCESSIBLE RESTROOM IS | | | MEASURED FROM THE UNFINISHED WALL AND SHALL BE TO THE | | | CENTERLINE OF THE WATER CLOSET 16 INCHES MINIMUM TO 18 | | | INCHES MAXIMUM FROM THE SIDE WALL PER THE 2020 FBC ACC. | | | SEC. 604.2 LOCATION. | | | | | | 6. 5. ON SHEET A 403; | | | | | | A. THERE IS A VERTICAL GRAB BAR, BUT THEY SHALL BE | | | INSTALLED IN A HORIZONTAL POSITION PER THE 2020 FBC ACC | | | SEC. 609.4. | | | | | | B. THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | | GRIPPING SURFACE PER THE 2020 FBC ACC SEC. 609.4. | | | | | | C. ON DETAIL, C2 AND C7 SHOW A POWDER RESTROOM THAT MAY | | | REQUIRE THE LAV, TOILET, AND GRAB BARS TO BE ACCESSIBLE | | | PER THE 2020 FBC ACCESSIBILITY CODE. | | | | | | D. ON DETAIL A1, THE TOILET DISPENSER SHALL BE 7 INCHES | | | MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER | | | CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER PER | | | THE 2020 FBC ACC SEC. 604.7. | | | | | | E. ON DETAIL A5, THE REFLECTIVE PART OF THE MIRROR | | | NEEDS TO BE 4 INCHES TO THE REFLECTIVE SIDE PER THE | | | 2020 FBC ACC SEC. 603.3. | | | | | | 7. ON SHEETS P202, P203, AND P402, THE ICE MAKER AND | | | COFFEE MAKER SHALL BE EQUIPPED WITH AN IN-LINE VACUUM | | | BREAKER THAT COMPLIES WITH ASSE 1024 PER THE 2020 FBC | | | SEC. 608.13.10. | | | | | | 8. ON SHEET P 401, THERE ARE FLOOR DRAINS IN EACH | | | RESTROOM AND JANITOR'S ROOM, BUT IT LOOKS LIKE TWO. FOR | | | EXAMPLE, THE LADIES ROOMS HAVE TWO FDR LABELED. WOULD | | | YOU PLEASE CLARIFY PER THE WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS? | | | | | | 9. ON SHEET 402 SHOWS THE HOT WATER LINES LOOPED FOR | | | THE RECIRCULATING SYSTEM AND ARE NOT IN A CONTINUOUS | | | LOOP. THERE ARE REQUIREMENTS IN THE FLORIDA ENERGY CODE | | | SEC. C404.6.1. THERE IS A TABLE THAT LIMITS THE | | | DISTANCE BETWEEN THE SOURCE AND THE OUTLET. PLEASE | | | REFER TO TABLE 405.5.1 FOR THE MAXIMUM ALLOWABLE PIPE | | | LENGTH METHOD AND SIZE ACCORDANTLY. | | | | | | 10. ON SHEET P 503; | | | | | | A. WOULD YOU PLEASE PROVIDE A HAMMER ARRESTOR, WHICH | | | SHALL BE INSTALLED WHERE QUICK-CLOSING VALVES ARE | | | UTILIZED PER THE 2020 FBC SEC. P 604.9. | | | | | | B. WOULD YOU PLEASE PROVIDE THERMAL EXPANSION CONTROL | | | IN THE STORAGE WATER HEATER PER THE 2020 FBC SEC. P | | | 607.3. | | | | | | C. IT SHOWS AN OVERFLOW BALANCING VALVE. IS THE DRAIN | | | TO A SPECIFIC LOCATION? WOULD YOU PLEASE CLARIFY PER | | | THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS? | | | | | | D. THE RECALCULATING PER THE MANUFACTURES SPECIFICATION | | | AND MAINTENANCE PURPOSES MAY REQUIRE SHUT-OFF VALVES ON | | | EACH SIDE OF THE RECALCULATING PUMP PER THE 2020 FBC | | | SEC. 606.2 LOCATION OF SHUTOFF VALVES. | | | | | | 11. ON SHEET P601; | | | | | | A. DETAIL 1 SHOWS THE PUMP WITH ONE VALVE. WOULD YOU | | | PLEASE CORRECT IT PER COMMENT D IN THE PREVIOUS | | | COMMENT? | | | | | | B. THE PRESSURE RELIEF VALVE IS THROUGH A WALL; PLEASE | | | CHANGE IT TO DRAIN INTO THE MOP SINK AS SHOWN IN DETAIL | | | 2 PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | C. WOULD YOU PLEASE SHOW THE THERMAL EXPANSION CONTROL | | | IN THE STORAGE WATER HEATER PER THE 2020 FBC SEC. P | | | 607.3. | | | | | | 12. ON SHEET P602; | | | | | | A. WOULD YOU PLEASE SUBMIT LISTED FIRE-STOPPING DETAILS | | | FOR THE PIPPING THROUGH RATED WALLS OR THE FLOORS. | | | PLEASE SUBMIT THE COMPLETE ASSEMBLY DETAILS FOR THE | | | SYSTEMS PER THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | 6. WOULD YOU PLEASE PROVIDE THE UL ASSEMBLY FOR NEW | | | WALL PENETRATIONS TO COMPLY WITH THE 2020 FBC CHAPTER | | | 7. | | | | | | B. WOULD YOU PLEASE PROVIDE DETAIL FOR THE RIGID | | | SUPPORT SWAY BRACING, WHICH SHALL BE PROVIDED AT | | | CHANGES IN A DIRECTION MORE SIGNIFICANT THAN 45 DEGREES | | | FOR PIPE SIZES 4 INCHES AND LARGER PER FBC-PLUMBING | | | SEC. 308.6. SUBMIT DETAILS FOR THE BRACING. | | | | | | PLEASE FEEL FREE TO SET UP A MEETING OR CONTACT ME ON | | | ANY OF THE COMMENTS BY PHONE OR ZOOM MEETING IF YOU | | | LIKE TO PREVENT FURTHER REVIEWS. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, DESCRIBING THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2022-01-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-19 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-19 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-12 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-12 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-22 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-22 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2021-12-22 09:44:18 | SIGNATURE REVIEW | | | | | | THE THRESHOLD/SPECIAL INSPECTOR FORM THAT IS SIGNED AND | | | SEALED - DOES NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | | READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-23 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-23 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2021-11-23 13:49:45 | SIGNATURE REVIEW | | | | | | DRAWINGS G002, G003, FP001, FP101, FP102, FA001, FA101, | | | FA102 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-09 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-09 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2021-11-09 15:04:53 | SIGNATURE REVIEW | | | | | | DRAWINGS G002, G003, FP001, FP101, FP102, FA101 DO NOT | | | SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-25 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-25 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2021-08-25 13:45:01 | SIGNATURE REVIEW | | | DRAWINGS G002, G003, ALL FP DRAWINGS AND ALL FA | | | DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN ADOBE | | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | | TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER | | | OR ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR | | | - IF YOUR ARCHITECT OR ENGINEER DOES NOT HAVE AN | | | ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DIVISION AT THE CITY HALL. | | | | | 2021-08-25 10:12:25 | MECHANICAL SHEETS SIGNATURES ARE APPROVED ME |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
4 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-22 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-22 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-23 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-23 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2021-11-23 13:54:31 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | THRESHOLD BUILDING | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | NOTE: THIS STRUCTURE IS CONSIDERED A THRESHOLD BUILDING | | | PER FS 553.71 12) "THRESHOLD BUILDING" MEANS ANY | | | BUILDING WHICH IS GREATER THAN THREE STORIES OR 50 FEET | | | IN HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DEFINED IN THE FLORIDA BUILDING CODE | | | WHICH EXCEEDS 5,000 SQUARE FEET IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER THE | | | "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS". | | | YOU CAN E MAIL ME AND ASK FOR A COPY. | | | | | | A) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | | | | B) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2021-11-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-09 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-09 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2021-11-09 15:07:56 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | THRESHOLD BUILDING | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | NOTE: THIS STRUCTURE IS CONSIDERED A THRESHOLD BUILDING | | | PER FS 553.71 12) "THRESHOLD BUILDING" MEANS ANY | | | BUILDING WHICH IS GREATER THAN THREE STORIES OR 50 FEET | | | IN HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DEFINED IN THE FLORIDA BUILDING CODE | | | WHICH EXCEEDS 5,000 SQUARE FEET IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER THE | | | "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS". | | | YOU CAN E MAIL ME AND ASK FOR A COPY. | | | | | | A) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | | | | B) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-25 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-25 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2021-08-25 13:15:34 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | THRESHOLD BUILDING | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | NOTE: THIS STRUCTURE IS CONSIDERED A THRESHOLD BUILDING | | | PER FS 553.71 12) "THRESHOLD BUILDING" MEANS ANY | | | BUILDING WHICH IS GREATER THAN THREE STORIES OR 50 FEET | | | IN HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DEFINED IN THE FLORIDA BUILDING CODE | | | WHICH EXCEEDS 5,000 SQUARE FEET IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER THE | | | "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS". | | | YOU CAN E MAIL ME AND ASK FOR A COPY. | | | | | | 1) ANY REPAIRS TO THRESHOLD BUILDINGS ARE REQUIRED TO | | | COMPLY WITH FS 553.79 (5)(A). THRESHOLD BLDG. REQUIRED | | | STATEMENT: W.P.B. AMENDMENT 110.8.4.4 ALL PLANS FOR THE | | | BUILDING WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY | | | THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE | | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS SECTION AND CHAPTER | | | 633 FLORIDA STATUTES. | | | | | | A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION | | | PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | | | | C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT | | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD SHALL CONTAIN A STATEMENT THAT, TO THE BEST OF | | | THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. | | | | | | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | | | | | | | |
|
|