Plan Review Details - Permit 21080537
Plan Review Stops For Permit 21080537
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-08-02 Cont ID  
Sent By rmcphers Date 2022-08-02 Time 15:48 Rev Time 0.00
Received By rmcphers Date 2022-08-02 Time 15:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-21 Cont ID  
Sent By rmcphers Date 2022-06-21 Time 17:02 Rev Time 0.00
Received By rmcphers Date 2022-06-21 Time 17:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-04-11 Cont ID  
Sent By rmcphers Date 2022-04-11 Time 13:01 Rev Time 0.00
Received By rmcphers Date 2022-04-11 Time 13:01 Sent To  
Notes
2022-04-11 13:01:38REVISION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) ACCESSIBLE RESTROOM = PLEASE SHOW THE MIRROR
 DIMENSION FROM THE FLOOR TO THE BOTTOM OF THE
 "REFLECTIVE SURFACE" TO COMPLY WITH FBC 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-27 Cont ID  
Sent By jleahy Date 2022-06-27 Time 11:04 Rev Time 0.00
Received By jleahy Date 2022-06-27 Time 11:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-04-21 Cont ID  
Sent By jleahy Date 2022-04-21 Time 16:02 Rev Time 0.00
Received By mpeterso Date 2022-04-21 Time 16:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-03-29 Cont ID  
Sent By pleduc Date 2022-03-29 Time   Rev Time 0.00
Received By pleduc Date 2022-03-29 Time 13:39 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2022-04-12 Cont ID  
Sent By fmittner Date 2022-04-12 Time 11:50 Rev Time 0.00
Received By amhamilt Date 2022-04-12 Time 11:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-02 Cont ID  
Sent By rmcphers Date 2022-08-02 Time 15:49 Rev Time 0.00
Received By rmcphers Date 2022-07-19 Time 16:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-27 Cont ID  
Sent By jleahy Date 2022-06-27 Time 11:04 Rev Time 0.00
Received By jleahy Date 2022-05-31 Time 16:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-21 Cont ID  
Sent By mpeterso Date 2022-04-21 Time 16:02 Rev Time 0.00
Received By mpeterso Date 2022-03-28 Time 12:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-13 Cont ID  
Sent By medwards Date 2022-06-13 Time 13:03 Rev Time 0.00
Received By medwards Date 2022-06-13 Time 13:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-04-11 Cont ID  
Sent By medwards Date 2022-04-11 Time 16:36 Rev Time 0.00
Received By medwards Date 2022-04-11 Time 16:36 Sent To  
Notes
2022-04-11 16:37:051ST REVIEW FMC
 PERMIT: 21080537
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THIS APPEARS TO BE A REVISION TO A SHELL PERMIT?
 THERE WAS NO MECHANICAL SUBMITTED FOR THE SHELL PERMIT
 19120512. PROVIDE THE ENERGY CALCULATIONS AND THE
 MECHANICAL EQUIPMENT SIZING CALCULATIONS FOR THIS NEW
 BUILDING. FBC 107.2.1
  
 2) SHEET M801 APPEARS TO INCLUDE MULTIPLE AHU?S AND
 EXHAUST FANS. THE MECHANICAL SHEET M301 ONLY INDICATES
 AHU-1, EF-1 AND EF-2. PLEASE REMOVE ALL OTHER UNITS
 THAT DO NOT BELONG WITH THIS UNIT.
  
 3) THE REVISION FORM DOES NOT INCLUDE THE VALUE OF THIS
 REVISION. THERE CLEARLY IS A VALUE TO THIS MECHANICAL
 SYSTEM THAT WAS NOT INCLUDED IN THE SHELL PERMIT.
 PLEASE SHOW THE ACCURATE VALUE FOR THIS MECHANICAL
 SYSTEM.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-07-21 Cont ID  
Sent By jesmith Date 2022-07-21 Time 13:38 Rev Time 0.00
Received By jesmith Date 2022-07-21 Time 13:35 Sent To  
Notes
2022-07-21 13:38:3621080537 626 7TH ST
 MASTER 19120504 LOT 7A REVISION
  
 PLUMBING COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-06-02 Cont ID  
Sent By jesmith Date 2022-06-02 Time 15:06 Rev Time 0.00
Received By jesmith Date 2022-06-02 Time 15:06 Sent To  
Notes
2022-06-02 15:01:51WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21080537 626 7TH ST
 MASTER 19120504 LOT 7A REVISION
  
 SIGNATURES FOR PLUMBING; ELECTRONIC SIGNATURES APPEAR
 TO BE SCANNED. CORRECTIONS NEEDED. IN LIEU OF VALID
 ELECTRONIC SIGNATURE, A PHYSICAL SET OF APPROVED PLANS
 SIGNED, DATED AND SEALED BY THE DESIGNER AS REQUIRED BY
 FAC 61G15-23.001 SHALL BE PROVIDED TO THE BUILDING
 DEPARTMENT PRIOR TO ISSUANCE OF PERMIT. JS
  
 2ND REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6 PROVIDE PLAN AND ELEVATION DETAILS
 FOR NEW TOILET ROOM INDICATING THE FOLLOWING:
 ***A) COMPLIED
 ***B) SECOND REQUEST: PER FBC 606.5 EXPOSED PIPES AND
 SURFACES. WATER SUPPLY & DRAINPIPES UNDER LAVATORIES
 AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO
 PROTECT AGAINST CONTACT.
 ARCHITECT RESPONSE: NOTES HAVE BEEN REVISED TO REQUIRE
 G.C. TO PROVIDE INSULATION FOR DRAIN PIPE BELOW
 LAVATORY. PLEASE SEE SHEET A2.0B NOTES C8 & ELEVATION
 DETAIL 5 & 2
 NEW COMMENT:
 0001) NOTE C8 IS NOT ON THE PLAN
 0002) DETAIL 5 & 2 DO NOT MENTION INSULATION
  
 ***C) SECOND REQUEST: MIRRORS LOCATED ABOVE LAVATORIES
 OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE
 OF THE "REFLECTING" SURFACE 40 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND PER FBC ACC 603.3.
 ARCHITECT RESPONSE: THIS ADJUSTMENT HAS BEEN PROVIDED
 WITHIN REVISION 6. THE MIRRORS DIMENSION FROM THE FLOOR
 TO THE REFLECTIVE SURFACE IS 40 INCHES. PLEASE SEE
 SHEET A2.0B DETAIL ELEVATION 5
 DIMENSION SHOWN IS CLEARLY TO BOTTOM OF APPARENT FRAME.
 PLEASE ADD THE WORDS "REFLECTING SURFACE" TO CLARIFY.
  
 2. SECOND REQUEST:
 BREAK ROOM SINK: NEW COMMENT: FBC ACC 804.3.1, REQUIRES
 THE CLEAR FLOOR SPACE TO BE CENTERED ON THE KITCHEN
 WORK SURFACE, WHILE THIS IS DIRECTED AT KITCHENS AND
 KITCHENETTES REQUIRING A FORWARD APPROACH, IT APPEARS
 THAT A PERSON OPERATING A WHEELCHAIR WOULD BE HARD
 PRESSED TO COMFORTABLY ACCESS THE CONTROLS OF THE HAND
 SINK WITH A SIDE APPROACH THAT DOES NOT CENTER ON THE
 FIXTURE. PLEASE REVIEW FBC ACC 308 AND 309. CONSIDER
 PROVIDING A FORWARD APPROACH WITH KNEE AND TOE
 CLEARANCE.
 NO RESPONSE FROM ARCHITECT. PLEASE ACKNOWLEGE AND
 PROVIDE A RESPONSE.
  
 3. COMPLIED
  
 4. COMPLIED
  
 5. N/A
  
 6. P801: REGARDING THE PLUMBING FIXTURE SCHEDULE
 COMMENT REFERRING TO ARCHITECT, OWNERSHIP OR INTERIOR
 DESIGN FOR SELECTION OF ALL FIXTURES AND ACCESSORIES,
 PER WPB FBC 107.2.1, SUBMIT MANUFACTURER?S
 SPECIFICATION/INSTALLATION MANUALS FOR ALL SCHEDULED
 PLUMBING FIXTURES AND ACCESSORIES.
 ARCHITECT RESPONSE: PLEASE SEE ATTACHED FOR
 MANUFACTURER'S SPECIFICATIONS FOR PLUMBING FIXTURES
 NEW COMMENT: WATER CLOSET, LAVATORY, FAUCET AND BOTTLE
 TRAP ARE SHOWN ON A2.0B. HOWEVER, THE LAVATORY IS NOT
 INCLUDED IN THE ATTACHMENTS (SUPPORTING DOCUMENTS)
 NEW COMMENT: BOTTLE TRAP- SEE FBC PL 1002.3(4) AND FBC
 PL 412.1.2. PROVIDE IN MANUFACTURER?S
 SPECIFICATION/DOCUMENTATION, THE MANUFACTURING
 STANDARD(S) THE PRODUCT COMPLIES WITH
 EXAMPLE: KOHLER K-9033 BOTTLE TRAP SPEC SHEET SHOWS
 COMPLIANCE WITH ASME A112.18.2/CSA B125.2
  
 4. COMPLIED
  
 5. COMPLIED
  
 6. COMPLIED
  
 7. COMPLIED
  
 8. NOT IN THIS PERMIT
  
 9. NOT IN THIS PERMIT
  
 10. NOT IN THIS PERMIT
  
 11. COMPLIED
  
 12. NEW COMMENT: REGARDING THE SUBMITTED GREASE TRAP
 PLAN UPLOADED TO SUPPORTING DOCUMENTS, PLEASE NOTE THAT
 THE DOCUMENT MUST BE DATED, SIGNED AND SEALED BY THE
 DESIGNER AS REQUIRED BY CHAPTER 471 FS & 61G15 FAC OR
 481 FS & 61G1 FAC
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-04-12 Cont ID  
Sent By jesmith Date 2022-04-12 Time 15:32 Rev Time 0.00
Received By jesmith Date 2022-04-12 Time 15:29 Sent To  
Notes
2022-04-12 15:30:10CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21080537 626 7TH ST
 MASTER 19120504 LOT 7A REVISION
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 GENERAL COMMENT: DUE TO A CHANGE IN PROCESS, THE
 BACKFLOW PERMIT AND GREASE INTERCEPTOR PERMITS ARE
 REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE
 PRIMARY PERMIT (AS APPLICABLE). YOU CAN SUBMIT AN
 APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT HAVE
 A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT
 APPLICATION TO [email protected] . YOU WILL
 RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU
 MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE
 APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT
 YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER
 YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL
 AND I WILL CHANGE THE REVIEW STATUS TO PASS.
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6 PROVIDE PLAN AND ELEVATION DETAILS
 FOR NEW TOILET ROOM INDICATING THE FOLLOWING:
 ***A) PROVIDE DIMENSIONS OF CLEARANCE AROUND A WATER
 CLOSET; SHALL BE 60 INCHES MINIMUM MEASURED
 PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES DEEP
 MINIMUM FOR WALL HUNG WATER CLOSETS AND 59 INCHES DEEP
 MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED
 PERPENDICULAR TO THE REAR WALL PER FBC ACC 604.3.1 AND
 604.8.1.1.
 ***B) PER FBC 606.5 EXPOSED PIPES AND SURFACES. WATER
 SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE
 INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
 CONTACT.
 ***C) MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 ?REFLECTING? SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND PER FBC ACC 603.3.
 ***D) PER FBC ACC 211.1, WHERE DRINKING FOUNTAINS ARE
 PROVIDED ON AN EXTERIOR SITE, ON A FLOOR, OR WITHIN A
 SECURED AREA THEY SHALL BE PROVIDED IN ACCORDANCE WITH
 211. PER 211.1, NO FEWER THAN TWO DRINKING FOUNTAINS
 SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY
 WITH 602.1 THROUGH 602.6 AND ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
 TO BE CLEAR, THE SUBMITTED SINGLE DRINKING FOUNTAIN
 WITH A BOTTLE FILLER DOES NOT COMPLY WITH FBC PL 602.4
 (MAXIMUM SPOUT HEIGHT 36 INCHES ABOVE THE FLOOR FOR
 WHEELCHAIR ACCESSIBILITY) AND 602.7 (MINIMUM SPOUT
 HEIGHT 38 INCHES ABOVE THE FLOOR FOR STANDING PERSONS);
 A2.0C/DETAIL 3 SHOWS SPOUT HEIGHT AT 37-1/2 INCHES
 ABOVE THE FLOOR. PER WPB FBC 107.2.1, SCHEDULE AND
 SPECIFY FOR DRINKING FOUNTAIN(S) SHOWING FULL
 COMPLIANCE WITH FBC ACC 602.1 THROUGH 602.7. PLEASE
 CONTACT ROBERT BROWN, BUILDING OFFICIAL AT 561-805-6652
 WITH ANY QUESTION OR CONCERNS.
  
 2. BREAK ROOM SINK: NEW COMMENT: FBC ACC 804.3.1,
 REQUIRES THE CLEAR FLOOR SPACE TO BE CENTERED ON THE
 KITCHEN WORK SURFACE, WHILE THIS IS DIRECTED AT
 KITCHENS AND KITCHENETTES REQUIRING A FORWARD APPROACH,
 IT APPEARS THAT A PERSON OPERATING A WHEELCHAIR WOULD
 BE HARD PRESSED TO COMFORTABLY ACCESS THE CONTROLS OF
 THE HAND SINK WITH A SIDE APPROACH THAT DOES NOT CENTER
 ON THE FIXTURE. PLEASE REVIEW FBC ACC 308 AND 309.
 CONSIDER PROVIDING A FORWARD APPROACH WITH KNEE AND TOE
 CLEARANCE.
  
 3. A1.1A: PLUMBING FIXTURE SCHEDULE DOES NOT SHOW
 DRINKING FOUNTAIN AS A REQUIRED FIXTURE. PER WPB FBC
 107.2.1 AND, PROVIDE A NOTE STATING "IN ACCORDANCE WITH
 FBC PL 410.4, THIS RESTAURANT WILL PROVIDE DRINKING
 WATER IN A FLAT BOTTOM CONTAINER FREE OF CHARGE."
  
 4. P701/SANITARY RISER: PER FBC PL 1002.1, PROVIDE A
 WATER SEAL TRAP FOR THE MOP SINK.
  
 6. P801: REGARDING THE PLUMBING FIXTURE SCHEDULE
 COMMENT REFERRING TO ARCHITECT, OWNERSHIP OR INTERIOR
 DESIGN FOR SELECTION OF ALL FIXTURES AND ACCESSORIES,
 PER WPB FBC 107.2.1, SUBMIT MANUFACTURER?S
 SPECIFICATION/INSTALLATION MANUALS FOR ALL SCHEDULED
 PLUMBING FIXTURES AND ACCESSORIES.
  
 4. RE: P701/DETAIL 5; WATER HEATER DETAIL. DETAIL
 INDICATES CONCRETE ANCHORS FOR WALL MOUNTED WATER
 HEATER SUPPORT. A2.0B ENLARGED FLOOR PLANS INDICATE
 METAL FRAMED PARTITIONS, NOT CONCRETE WALLS. PER WPB
 FBC 107.2.1, CLARIFY AND CORRECT AS NECESSARY.
  
 5. P701/DETAIL 5 NOTES PAN DRAIN TO THE MOP SINK;
 P801/WATER HEATER SCHEDULE NOTE 3 CALLS FOR PAN DRAIN
 TO NEAREST FLOOR DRAIN. PER WPB FBC 107.2.1, PLEASE
 CLARIFY AND RECONCILE; IT IS NOTED THAT THERE IS NO
 FLOOR DRAIN ON THE PLANS.
  
 6. P701/DETAIL 5 SHOWS T&P RELIEF VALVE DISCHARGE
 INDIRECTLY TO THE MOP SINK BUT SHOWS IT DISCHARGING TO
 THE PAN DRAIN THROUGH AN AIR GAP. PER WPB FBC 107.2.1,
 PLEASE CLARIFY AND RECONCILE; IT IS NOTED THAT THERE IS
 NO FLOOR DRAIN ON THE PLANS. PLEASE NOTE THAT ANY
 DISCHARGE TO A RECEPTACLE WILL REQUIRE AN AIR GAP PER
 FBC PL 504.2.
  
 7. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL BE
 LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND 605.2.1.
 PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS STATING THE
 SAME.
  
 8. GREASE INTERCEPTOR: PLEASE NOTE THAT PER FBC PL
 301.7 AND 303.2, THE INSTALLATION OF THE SCHIER GB-75
 GREASE INTERCEPTOR SHALL CONFORM TO A MINIMUM OF THE
 MANUFACTURER'S RECOMMENDATIONS. IN ACCORDANCE WITH THE
 GB-75 INSTALLATION GUIDE PAGE 8, 9 AND 10 OF 10, A
 TWO-WAY CLEANOUT IS REQUIRED ON BOTH THE INLET AND
 OUTLET SIDE OF THE GREASE INTERCEPTOR.
  
 9. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR TIEDOWN OF
 GREASE INTERCEPTOR. PROVIDE DETAIL OF BURIED TANK.
 PROVIDE INFORMATION SHOWING THAT BOTTOM EDGE OF
 EXCAVATION WILL NOT ADVERSELY AFFECT OR UNDERMINE THE
 FOOTERS. SEE FBC PL 307.5 AND FBC 1803.5.7. SEE THE
 FOLLOWING:
 ***A) PLEASE NOTE THAT PER FBC PL 301.7 AND 303.2, THE
 INSTALLATION OF THE SCHIER GB-75 GREASE INTERCEPTOR
 SHALL CONFORM TO A MINIMUM OF THE MANUFACTURER'S
 RECOMMENDATIONS.
 ***B) TO BE CLEAR, PROVIDE A DETAIL FOR THE UNDERGROUND
 INSTALLATION OF THE SCHIER GB-75 GREASE INTERCEPTOR.
 PLEASE REFER TO THE SCHIER GB-75 INSTALLATION GUIDE
 PAGE 3, 8, 9 AND 10 OF 10 FOR DETAILS. PLEASE NOTE THE
 REFERENCE TO TIE DOWNS AND MAKE A FINAL DETERMINATION
 AS TO THE APPLICABILITY TO THIS PROJECT.
 ***C) PROVIDE INFORMATION SHOWING THAT BOTTOM EDGE OF
 EXCAVATION WILL NOT ADVERSELY AFFECT OR UNDERMINE THE
 FOOTERS. SEE FBC PL 307.5 AND FBC 1803.5.7.
  
 10. REGARDING THE SAMPLING POINT INSTALLED UPSTREAM OF
 THE GB-75:
 ***A) IN ACCORDANCE WITH THE SCHIER SV-10 INSTALLATION
 GUIDE (SEE FBC PL 301.7 AND 303.2), THE SAMPLING POINT
 SHALL BE DOWNSTREAM OF THE INTERCEPTOR.
 ***B) PER WPB FBC 107.2.1, PLEASE SPECIFY THE SAMPLING
 POINT DEVICE TO BE INSTALLED (SCHIER PRODUCT IS SV-10)
 ***C) PLEASE NOTE THAT THE JURISDICTION ACCEPTS A
 TWO-WAY CLEANOUT FOR USE AS A SAMPLING POINT
  
 11. PER FBC PL 606.2(2), PROVIDE A SHUT-OFF VALVE ON
 THE WATER SUPPLY PIPE TO EACH SILLCOCK/HOSE BIB.
  
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-08-02 Cont ID  
Sent By rmcphers Date 2022-08-02 Time 15:49 Rev Time 0.00
Received By rmcphers Date 2022-08-02 Time 15:49 Sent To  
Notes
2022-07-21 13:47:59SIGNATURES FOR PLUMBING ARE VALID. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-21 Cont ID  
Sent By rmcphers Date 2022-06-21 Time 17:09 Rev Time 0.00
Received By rmcphers Date 2022-06-21 Time 17:09 Sent To  
Notes
2022-06-13 13:04:59MECHANICAL DIGITAL SIGNATURES APPROVED ME
2022-06-02 13:44:44SIGNATURES FOR PLUMBING; ELECTRONIC SIGNATURES APPEAR
 TO BE SCANNED. CORRECTIONS NEEDED. IN LIEU OF VALID
 ELECTRONIC SIGNATURE, A PHYSICAL SET OF APPROVED PLANS
 SIGNED, DATED AND SEALED BY THE DESIGNER AS REQUIRED BY
 FAC 61G15-23.001 SHALL BE PROVIDED TO THE BUILDING
 DEPARTMENT PRIOR TO ISSUANCE OF PERMIT. JS
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-04-11 Cont ID  
Sent By rmcphers Date 2022-04-11 Time 13:07 Rev Time 0.00
Received By rmcphers Date 2022-04-11 Time 13:07 Sent To  
Notes
2022-04-12 15:33:43SIGNATURES FOR PLUMBING: SELECTED CERTIFICATE PATH HAS
 ERRORS; NOT TIME VALID. CORRECTIONS NEEDED. JS

Review Stop Z ZONING
Rev No 2 Status P Date 2022-06-09 Cont ID  
Sent By ckimmerl Date 2022-06-09 Time 11:35 Rev Time 0.00
Received By ckimmerl Date 2022-06-09 Time 11:32 Sent To  
Notes
2022-06-09 11:32:411. PROVISO: PLEASE UPDATE COVER SHEET WITH MINOR
 CORRECTIONS:
 A. COMMISSIONERS: DISTRICT 1: CATHLEEN WARD
 B. RICK GREEN IS THE DEVELOPMENT SERVICES DIRECTOR
 C. CHRIS ROOG IS THE CRA EXECUTIVE DIRECTOR
  
  
 2. PROVISO: ANY GROUND-MOUNTED MECHANICAL EQUIPMENT
 INCLUDING BUT NOT LIMITED TO AC UNITS, WATER METERS,
 BACKFLOW PREVENTERS, TRANSFORMERS, ETC. SHALL BE
 SCREENED FROM VIEW WITH LANDSCAPE HEDGES.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-04-07 Cont ID  
Sent By aabdalla Date 2022-04-07 Time 12:06 Rev Time 0.00
Received By ckimmerl Date 2022-04-07 Time 12:06 Sent To  
Notes
2022-04-07 12:06:491. PROVISO: PLEASE UPDATE COVER SHEET WITH MINOR
 CORRECTIONS:
 A. COMMISSIONERS: DISTRICT 1: CATHLEEN WARD
 B. RICK GREEN IS THE DEVELOPMENT SERVICES DIRECTOR
 C. CHRIS ROOG IS THE CRA EXECUTIVE DIRECTOR
  
  
 2. PROVISO: ANY GROUND-MOUNTED MECHANICAL EQUIPMENT
 INCLUDING BUT NOT LIMITED TO AC UNITS, WATER METERS,
 BACKFLOW PREVENTERS, TRANSFORMERS, ETC. SHALL BE
 SCREENED FROM VIEW WITH LANDSCAPE HEDGES.
  